Plan Review Details - Permit 08060204
Plan Review Stops For Permit 08060204
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-07-30 Cont ID  
Sent By shill Date 2008-07-30 Time 18:16 Rev Time 0.00
Received By shill Date 2008-07-30 Time 18:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-07-02 Cont ID  
Sent By shill Date 2008-07-02 Time 11:02 Rev Time 0.00
Received By shill Date 2008-07-02 Time 11:02 Sent To  
Notes
2008-07-02 11:07:55****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.SEE OPENING 8.A 2" EDGE DISTANCE REQUIRES A
 FACTOR OF .50, SEE SHEET 5 (9" SPACING TIMES .5 WOULD
 REQUIRE A MAXIMUM OF 4.5" SPACING).
  
 2.IT IS ACCEPTABLE TO EXCEED CODE COMPLIANCE.
 HOWEVER, PLEASE CLARIFY WHY 4", 4 1/2", AND 8" ARE
 SPECIFIED FOR BOTTOM ANCHOR SPACING BUT THE CONDITIONS
 ARE THE SAME AS THE TOP WHICH SPECIFIES 9".THIS IS
 ACCEPTABLE; YOU CAN ALWAYS DECREASE ANCHOR SPACING
 PROVIDED IT MEETS THE MINIMUM SPACING.HOWEVER, PLEASE
 CONFIRM THAT ALL OTHER INFORMATION IS CORRECT AND IF
 POSSIBLE CLARIFY.PLEASE NOTE THAT THE PLAN REVIEW
 WOULD NOT FAIL FOR THIS REASON.
  
 3.I ATTEMPTED TO GET THIS RESOLVED ON THE TELEPHONE;
 PLEASE NOTE THAT YOUR SERVICE WOULD NOT ALLOW A
 LENGTHY.I WAS HOPING TO LEAVE A DETAILED MESSAGE BUT
 WAS CUT OFF.PLEASE ADDRESS COMMENTS (REVISE THE
 INSTALLATION SCHEDULE) AND RESUBMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-11 Cont ID  
Sent By shill Date 2008-06-11 Time 15:37 Rev Time 0.00
Received By shill Date 2008-06-11 Time 15:37 Sent To  
Notes
2008-06-11 15:39:03****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 _XX_1.DOCUMENTS PREPARED BY AN ARCHITECT OR
 ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16.PLEASE
 NOTE THAT ENGINEERING IS NOT REQUIRED FOR BUILDINGS
 UNDER 60FEET.
  
 ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT, FBC*106.TWO SETS REQUIRED.
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____5.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3
 ABOVE.
  
 ____8.REVISE EXPOSURE CATEGORY OR EXPLAIN RATIONALE
 FOR EXPOSURE B.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-24 Cont ID  
Sent By adarroug Date 2008-07-24 Time 09:34 Rev Time 0.00
Received By adarroug Date 2008-07-24 Time 09:33 Sent To B
Notes
2008-07-24 09:34:36TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-25 Cont ID  
Sent By adarroug Date 2008-06-25 Time 10:09 Rev Time 0.00
Received By adarroug Date 2008-06-25 Time 10:09 Sent To B
Notes
2008-06-25 10:09:49TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-11 Cont ID  
Sent By shill Date 2008-06-11 Time 15:39 Rev Time 0.00
Received By shill Date 2008-06-09 Time 10:42 Sent To  
Notes
2008-06-09 10:42:57TO "MISC" BOX#1