Plan Review Details - Permit 08060201
Plan Review Stops For Permit 08060201
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-08-08 Cont ID  
Sent By mjacobs Date 2008-08-08 Time 14:17 Rev Time 0.00
Received By mjacobs Date 2008-08-08 Time 13:32 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-07-08 Cont ID  
Sent By mjacobs Date 2008-07-08 Time 12:45 Rev Time 0.00
Received By mjacobs Date 2008-07-08 Time 06:01 Sent To PC
Notes
2008-07-08 12:45:512ND REVIEW
 7-8-08
 BUILDING PLAN REVIEW
 PERMIT: 08060201
 ADD: 3700 GEORGIA AVE #10
 CONT: PRINCIPLE CONSTRUCTION LLC
 TEL: (561) 533-5252
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: DENIED
  
 1)OK
 2)OK
  
 3)ADDITIONAL INFORMATION REQUIRED 106.1.2* SUBMIT AN
 EXISTING FLOOR PLAN AND A PROPOSED FLOOR PLAN SHOWING
 ALL CHANGES TO THE EXISTING LAYOUT. THE ADDRESS ON THE
 PLANS SHALL INCLUDE THE UNIT/SUITE NUMBER FOR
 INSPECTION PURPOSES. THE DRAWINGS SUBMITTED DO NOT
 CLEARLY SHOW THE EXISTING PLAN FROM THE PROPOSED PLAN.
 THE EXISTING FLOOR PLAN SHALL ONLY SHOW THE WALLS AND
 SYSTEMS WHICH ARE PRESANTLY AT THIS LOACTION. THE
 EXISTING PLAN NEEDS TO SHOW THE PRESENT LAY-OUT OF THE
 SPACE. THE PROPOSE PLAN NEEDS TO SHOW THE FUTURE
 LAY-OUT OF THE SPACE. IF BOTH PLANS ARE ON THE SAME
 DRAWING THE WALLS TO BE DEMOLISH SHALL BE CLEARLY
 IDENTIFY WITH DOTED LINESOR SOME OTHER MEANS TO SHOW
 WHAT IS NEW AND WHAT IS EXISTING. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED
 AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THE CODE. 106.1.1*
  
 4)OK
 5)OK
  
 PARTIALLY ADDRESSED
 6)INDICATE ON THE PLANS THE OCCUPANT LOAD OF THE
 SPACE PER SECTION 1004 AND TABLE 1004.1.2. STATE THE
 USE OF THE OPEN AREA. PROVIDE A WALL LEGEND SHOWING THE
 EXISTING WALLS AND THE NEW CONSTRUCTED WALLS. DEPENDING
 ON THE USE OF OPEN SPACE ADDITIONAL COMMENTS MAY APPEAR
 ON THE NEXT REVIEW.
  
 7)OK
  
 NEEDS TO BE ADDRSSED
 8)108.3* THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING PURPOSES VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 STRUCTURAL, ELECTRIC INTERIOR FINISHES, ARCHITECTURAL
 DESIGN FEES, MARKETING COSTS OVERHEAD AND PROFIT
 EXCLUDING LAND.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-19 Cont ID  
Sent By mjacobs Date 2008-06-19 Time 11:30 Rev Time 0.00
Received By mjacobs Date 2008-06-19 Time 08:10 Sent To PC
Notes
2008-06-19 11:30:116-19-08
 BUILDING PLAN REVIEW
 PERMIT: 08060201
 ADD: 3700 GEORGIA AVE #10
 CONT: PRINCIPLE CONSTRUCTION LLC
 TEL: (561) 533-5252
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 3)ADDITIONAL INFORMATION REQUIRED 106.1.2* SUBMIT AN
 EXISTING FLOOR PLAN AND A PROPOSED FLOOR PLAN SHOWING
 ALL CHANGES TO THE EXISTING LAYOUT. THE ADDRESS ON THE
 PLANS SHALL INCLUDE THE UNIT/SUITE NUMBER FOR
 INSPECTION PURPOSES.
  
 4)TABLE 803.5 MINIMUM INTERIOR FINISH CLASSIFICATION;
 PROVIDE INFORMATION BASED ON INTERIOR FINISH
 REQUIREMENTS BASED ON OCCUPANCY.
  
 5)THE DOOR IN THE CORRIDOR SHALL A MINIMUM FIRE
 PROTECTION RATING OF 20 MINUTES, SO PLEASE INDICATE THE
 RATING IN MINUTES PER TABLE 715.3 SEE SECTION 715.3.3
 FOR MORE INFORMATION.
  
 6)INDICATE ON THE PLANS THE OCCUPANT LOAD OF THE
 SPACE PER SECTION 1004 AND TABLE 1004.1.2. STATE THE
 USE OF THE OPEN AREA. PROVIDE A WALL LEGEND SHOWING THE
 EXISTING WALLS AND THE NEW CONSTRUCTED WALLS. DEPENDING
 ON THE USE OF OPEN SPACE ADDITIONAL COMMENTS MAY APPEAR
 ON THE NEXT REVIEW.
  
 7)OFFICE #3 HAS NO ACCESS TO THE SPACE EXCEPT GOING
 THROUGH THE CORRIDOR. IF THIS IS A SEPARATE TENANT, THE
 SEVEN FOOT INTERIOR WALLS AROUND THIS SPACE WILL HAVE
 TO BE CHANGED TO PROVIDE TENANT SEPARATION FBC708.1
  
 8)108.3* THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING PURPOSES VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 STRUCTURAL, ELECTRIC INTERIOR FINISHES, ARCHITECTURAL
 DESIGN FEES, MARKETING COSTS OVERHEAD AND PROFIT
 EXCLUDING LAND.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-08-01 Cont ID  
Sent By btrobaug Date 2008-08-01 Time 10:49 Rev Time 0.00
Received By btrobaug Date 2008-08-01 Time 10:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-06-24 Cont ID  
Sent By btrobaug Date 2008-06-24 Time 11:19 Rev Time 0.00
Received By btrobaug Date 2008-06-24 Time 11:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-06-12 Cont ID  
Sent By btrobaug Date 2008-06-12 Time 16:10 Rev Time 0.00
Received By btrobaug Date 2008-06-12 Time 16:04 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-08-04 Cont ID  
Sent By mawillia Date 2008-08-04 Time 16:43 Rev Time 0.00
Received By mawillia Date 2008-08-04 Time 16:34 Sent To  
Notes
2008-08-04 16:43:38*****APPROVED*****
  
 PLANS WERE PREVIOUSLY APPROVED ON 07/01/08;SHEET A-1
 RESTAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-07-01 Cont ID  
Sent By mwennerg Date 2008-07-01 Time 15:31 Rev Time 0.00
Received By mwennerg Date 2008-07-01 Time 15:31 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-06-16 Cont ID  
Sent By mawillia Date 2008-06-16 Time 14:53 Rev Time 0.00
Received By mawillia Date 2008-06-16 Time 14:33 Sent To  
Notes
2008-06-16 14:53:02*****DENIED*****
  
 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DE3MOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OIR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 3.THE SCOPE OF WORK SHALL NOT INTERFERE OR HINDER
 ACCESS TO / EGRESS FROM THE OTHER TENANT OFFICES/SUITES
 IN THE SAID BUILDING.
  
 4.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 5.SPECIFY THE INTERIOR FINISH MATERIAL FOR THE NEW
 WALL PARTITION IN TERMS OF CLASS A, CLASS B, OR CLASS
 C.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-23 Cont ID  
Sent By adarroug Date 2008-07-23 Time 09:22 Rev Time 0.00
Received By adarroug Date 2008-07-23 Time 09:22 Sent To  
Notes
2008-07-28 09:01:59TO "BOB"#12
2008-07-23 09:22:58WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-23 Cont ID  
Sent By adarroug Date 2008-06-23 Time 11:30 Rev Time 0.00
Received By adarroug Date 2008-06-23 Time 11:30 Sent To  
Notes
2008-06-23 11:32:34TO "BOB"#6

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-23 Cont ID  
Sent By adarroug Date 2008-06-19 Time 11:26 Rev Time 0.00
Received By adarroug Date 2008-06-09 Time 10:48 Sent To  
Notes
2008-06-09 10:51:22TO "BOB"#5

Review Stop Z ZONING
Rev No 1 Status N Date 2008-06-10 Cont ID  
Sent By choops Date 2008-06-10 Time 08:39 Rev Time 0.00
Received By choops Date 2008-06-10 Time 08:39 Sent To  
Notes
2008-06-10 08:39:10*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.