| Plan Review Stops For Permit 08060195 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-08-08 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-08-08 |
Time |
16:47 |
Sent To |
PC |
|
| Notes |
| 2008-08-08 16:50:28 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- AS PER CONVERSATION WITH OWNER (RICK CRUZ) HOUSE | | | WILL HAVE FENCE AROUNDHOUSE AND EXIT ALARMS WILL BE | | | INSTALLED IN THE HOUSE.ACCESS GATES TO COMPLY WITH | | | SEC. R4101.17.1.8 AND EXIT ALARMS TO COMPLY WITH SEC. | | | R4101.17.1.9 OF 2004 FLORIDA RESIDENTIAL CODE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-30 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-30 |
Time |
11:34 |
Sent To |
PC |
|
| Notes |
| 2008-06-30 13:34:03 | RESIDENTIAL (R3)POOL, BUILDING REVIEW CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- CLEARLY SPECIFY HOW COMPLYING WITH THE RESIDENTIAL | | | SWIMMING BARRIER REQUIREMENTS OF SEC. R4101.17 OF 2004 | | | FLORIDA RESIDENTIAL CODE.NEED TO SPECIFY HOW | | | COMPLYING WITH THIS CODE SECTION WHEN HAVING ACCESSS TO | | | THE POOL FROM THE HOUSE OR HAVING ACCES TO THE POOL | | | FROMTHE OUTSIDE.SHEET 1 OF 3 SHOWS EXISTING FENCE, | | | BUT IT DOESN' SHOW LOCATION OF GATES AND IF THEY COMPLY | | | WITH SEC. R4101.17.1.8 OF 2004 FLORIDA RESIDENTIAL | | | CODE. | | | | | | 2- DRAWINGS NEED TO SHOW COMPLIANCE WITH SEC. R4101.18 | | | OF 2004 FLORIDA RESIDENTIAL CODE.LADDERS OR STEPS ARE | | | REQUIRED ON BOTH ENDS.NEED TO PROVIDE A WAY OF | | | GETTING OUT OF THE POOL ON BOTH ENDS OF POOL. | | | | | | 3- UPDATE ALL NOTES ON SHEET 1 OF 3.. THEY ALL REFER TO | | | SEC. 424 OF FBC.THIS IS A RESIDENTIAL SWIMMING POOL | | | AND CORRECT CODE TO BE REFERRED TO IS THE 2004 FLORIDA | | | RESIDENTIAL CODE CHAPTER 41. SEE CHAPTER AND REVISE ALL | | | NOTES AS REQUIRED WITH CORRESPONDING CODE SECTION.. | | | | | | 4-POOL VALUE WAS UPDATED TO $23,150 AS REQUIRED BY | | | SEC. 108.3 CITY AMENDMENTS TO FBC 2004. OWES $57.77 FOR | | | UPDATED VALUATION. | | | | | | 5- CLARIFY IF THERE IS GOING TO BE A POOL DECK OR NOT. | | | IF YES, THEN INCLUDE DECK INFORMATION AND VALUATION. | | | SEC. 108.3 CITY AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER. | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-08 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-08 |
Time |
09:21 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-16 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-16 |
Time |
07:07 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-08 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-08 |
Time |
10:20 |
Sent To |
B |
|
| Notes |
| 2008-08-08 10:21:55 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING | | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL | | | GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL | | | INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2008-06-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-18 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-18 |
Time |
15:09 |
Sent To |
B |
|
| Notes |
| 2008-06-18 15:10:31 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING | | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL | | | GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL | | | INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2008-06-06 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2008-06-06 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2008-06-06 14:46:36 | HISTORIC APPROVED BY JPAPA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-04 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-04 |
Time |
09:46 |
Sent To |
Z |
|
| Notes |
| 2008-08-04 09:46:41 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-30 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-09 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2008-06-09 10:08:42 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-08 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-08 |
Time |
10:20 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2008-06-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-18 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-18 |
Time |
15:09 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-08-08 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-08-08 |
Time |
16:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-08-06 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-08-06 |
Time |
11:10 |
Sent To |
E |
|
| Notes |
| 2008-08-06 11:11:59 | ***ZONING FAILED*** | | | | | | 1.INDICATE ON PLAN THAT THE FENCE COMPLETELY ENCLOSES | | | THE POOL.DOES NOT APPEAR SO ON SURVEY. PLEASE | | | CLARIFY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR | | | [email protected] | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-06-10 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-10 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-10 |
Time |
13:22 |
Sent To |
E |
|
| Notes |
| 2008-06-10 13:26:36 | ***FAILED*** | | | | | | | | | 1)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | | THE MINIMUM STANDARDS PROVIDED BELOW. | | | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS), SECTION, | | | 94-304(D)(2)(B)+(C): | | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED POOL | | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | | | | NOTE:IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT | | | TO OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN | | | AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|