Plan Review Details - Permit 08060153
Plan Review Stops For Permit 08060153
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-11 Cont ID  
Sent By shill Date 2008-06-11 Time 15:56 Rev Time 0.00
Received By shill Date 2008-06-11 Time 15:56 Sent To  
Notes
2008-06-11 15:58:09****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.SHOW THE DISTANCE BETWEEN THE PROPOSED SHED AND THE
 EXISTING BUILDING. FBC TABLE 601.
  
 2.DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR
 PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS
 FAC61G15-23.002, FS471. (ANCHORING DETAIL)
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-11 Cont ID  
Sent By shill Date 2008-06-11 Time 15:58 Rev Time 0.00
Received By shill Date 2008-06-05 Time 16:55 Sent To  
Notes
2008-06-05 16:56:04TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status F Date 2008-06-10 Cont ID  
Sent By choops Date 2008-06-10 Time 09:47 Rev Time 0.00
Received By choops Date 2008-06-10 Time 09:47 Sent To B
Notes
2008-06-10 09:51:52***FAILED***
  
  
 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 2)PLANS SHALL INDICATE THE SETBACK DIMENSIONS FROM
 THE PROPOSED SHED TO ALL ADJACENT PROPERTY LINES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "B" - MISC. 2