| Plan Review Stops For Permit 08060091 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-07-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-07-17 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-07-17 |
Time |
08:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-06-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-12 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-12 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2008-06-12 15:45:22 | BUILDING PLAN REVIEW | | | PERMIT: 08060091 | | | ADD: 1701 S. FLAGLER DR. #1802 | | | CONT: PROJECT ONE INTERIORS INC. | | | TEL: (561)541-4555 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODES. FLAGLER DR. | | | #1802 | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3)2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN | | | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | | THIS CODE. | | | | | | 4)PROVIDE A WALL DETAIL FOR THE NEW WALLS. THE DETAIL | | | SHALL INCLUDE THE STUD SPACING, THE TYPE OF STUDS METAL | | | OR WOOD AND THE TYPE OF DRYWALL OR SURFACE FINISH. | | | ADDITIONAL INFORMATION REQUIRED 106.1.2* | | | | | | 5)DUE TO THE FACT THAT THIS IS A HIGH-RISE BUILDING | | | THE DESIGN PRESSURES FOR THE SLIDING GLASS DOOR SHALL | | | BE DESIGN PER ASCE 7 AND CALCULATED BY A REGISTERED | | | PROFESSIONAL FBC 1609.1.1. THE PRODUCT APPROVAL SHALL | | | INDICATE BY CIRCLING OR HI-LIGHT THE TYPE OF GLASS AND | | | THE DESIGN PRESSURES FOR THE NEW DOOR FROM THE TABLES | | | PROVIDED IN THE INSTALLATION REPORT. PLEASE CHECK THE | | | PRODUCT APPROVAL AND MAKE SURE THE DOOR CAN BE USED AT | | | THIS LOCATION. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION AND NATURE | | | AND EXTENT OF THE WORK PROPOSED 106.1.1 | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-21 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-18 |
Time |
14:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-11 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-11 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-07-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-21 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-21 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2008-07-21 16:06:24 | PLANS ROUTED TO L. MARTINEZ FOR PROCESSING |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-06-16 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-06-16 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2008-06-16 11:02:07 | *****UNSAT***** | | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 3.THE SCOPE OF WORK SHALL NOT INTERFERE OR HINDER | | | ACCESS TO / EGRESS FROM THE OTHER UNITS ON THE SAID | | | FLOOR OR THE BUILDING. | | | | | | 4.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 5.SPECIFY THE INTERIOR FINISH MATERIALS FOR THE NEW | | | WALLS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 6.SHOW AND/OR EXPLAIN HOW THE FIRE SPRINKLER HEADS | | | AND SMOKE ALARMS WITHIN THE DWELLING UNIT WILL BE | | | IMPACTED AS A RESULT OF THE REMODEL. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-12 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-12 |
Time |
16:35 |
Sent To |
E |
|
| Notes |
| 2008-08-12 16:35:37 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-03 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-03 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2008-07-09 10:09:11 | TO "BOB"#5 | | 2008-07-03 08:42:31 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-16 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-05 |
Time |
09:18 |
Sent To |
PC |
|
| Notes |
| 2008-06-05 09:21:27 | TO "BOB"#1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-10 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-10 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-16 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-16 |
Time |
16:02 |
Sent To |
I |
|
| Notes |
| 2008-06-16 16:08:35 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. DECLARE THE GOVERNING CODE CYCLE. (FBC-2004 WITH | | | 2007 REVISIONS) PER (W.P.B. AS AMENDED) SECTION 106.5 | | | RETENTION OF CONSTRUCTION DOCUMENTS. | | | | | | 2. DECLARE LEVEL OF ALTERATION. PER FBC-2004 EXISTING | | | BUILDING CHAPTER 3. | | | | | | 3. CLEARLY INDICATE IF THE KITCHEN SINK W/FAUCET WILL | | | BE REPLACED WITH A NEW ONE OR IF THE EXISTING KITCHEN | | | SINK W/FAUCET IS BEING REUSED. PER FBC-2004 PLUMBING | | | SECTION 401.1 SCOPE. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-06 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-06 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2008-06-06 13:38:08 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|