Plan Review Details - Permit 08060046
Plan Review Stops For Permit 08060046
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-12-03 Cont ID  
Sent By mjacobs Date 2008-12-03 Time 12:06 Rev Time 0.00
Received By mjacobs Date 2008-12-03 Time 12:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-09-11 Cont ID  
Sent By mjacobs Date 2008-09-11 Time 08:15 Rev Time 0.00
Received By mjacobs Date 2008-09-11 Time 07:19 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-08-13 Cont ID  
Sent By mjacobs Date 2008-08-13 Time 07:49 Rev Time 0.00
Received By mjacobs Date 2008-08-13 Time 06:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-11 Cont ID  
Sent By mjacobs Date 2008-06-11 Time 14:51 Rev Time 0.00
Received By mjacobs Date 2008-06-11 Time 12:21 Sent To  
Notes
2008-06-11 14:51:41BUILDING PLAN REVIEW
 PERMIT: 08060046
 ADD: 105 S. NARCISSUS AVE. #130
 CONT: POINTE SITE DEV. CONST.
 TEL: (561)792-4313
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2)FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 4) 2004 FBC EXISTING 301.5.A DESIGN PROFESSIONAL OR
 AN OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF
 THIS CODE.
  
 5)A FIRE SPRINKLER PLAN IS REQUIRED TO SHOW HOW THE
 RENOVATION HAS AFFECTED THE LAYOUT OF THE EXISTING
 HEADS. YOU MAY SHOW THIS INFORMATION ON THE REFLECTED
 CEILING PLANS. 106.3.5.1.1(5)
  
 6)INDICATE THE ACCESSIBILITY SEATING ON THE PLANS
 WHICH SHALL MEET THE REQUIREMENTS OF SECTION 11-5,
 11-4.32 AND 11-4.33
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-12-08 Cont ID  
Sent By btrobaug Date 2008-12-08 Time 08:27 Rev Time 0.00
Received By btrobaug Date 2008-12-05 Time 16:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-09-03 Cont ID  
Sent By btrobaug Date 2008-09-03 Time 15:53 Rev Time 0.00
Received By btrobaug Date 2008-09-03 Time 15:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-08-14 Cont ID  
Sent By btrobaug Date 2008-08-14 Time 15:19 Rev Time 0.00
Received By btrobaug Date 2008-08-14 Time 14:06 Sent To PC
Notes
2008-08-14 15:14:17 
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC CHAPTER 1 AS
 AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: ALL
 COMMENTS RELATE TO SHEET E-1 UNLESS OTHERWISE NOTED.
  
 THESE ARE REPEAT COMMENTS FROM THE PREVIOUS REVIEW,
 ***INDICATES FURTHER EXPLANATION OF COMMENT, SHEET
 E-1.
  
 2} THIS PROJECT MUST COMPLY WITH CHAPTER 13 FBC. SEE
 13-415.1ABC.1.1FOR TIME CLOCK REQUIREMENTS AND.FOR
 LIGHTING DENSITIES ALL THAT IS REQUIRED FOR THE
 ELECTRICAL REVIEW IS THE BASIC PRESCRIPTIVE
 REQUIREMENTS. SEE 13-415.2.ABC.1 PERFORMANCE
 CALCULATION PROCEDURES, GENERAL.
 THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR
 A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING
 SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD
 DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE
 METHOD DESCRIBED IN SECTION 415.2.B.1.THE INSTALLED
 INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH
 SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR
 LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH
 SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE
 DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF
 THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE
 DENSITY REQUIREMENTS.INDICATE WATTAGES ON THE FIXTURE
 SCHEDULE.***THE WATTAGES PER SQUARE FOOT EXCEED THE
 MAXIMUM ALLOWED, NO TIME CLOCK IS SHOWN ON THE PLAN
  
 3} INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBCSPACE
 CONTROLS FOR LIGHTING.***13-415.1.ABC.1.2 SPACE
 CONTROL.
 EACH SPACE ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL
 HAVE AT LEAST ONE CONTROL DEVICE TO INDEPENDENTLY
 CONTROL THE GENERAL LIGHTING WITHIN THE SPACE. EACH
 MANUAL DEVICE SHALL BE READILY ACCESSIBLE AND LOCATED
 SO THE OCCUPANTS CAN SEE THE CONTROLLED LIGHTING.
  
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-06-10 Cont ID  
Sent By btrobaug Date 2008-06-10 Time 14:40 Rev Time 0.00
Received By btrobaug Date 2008-06-10 Time 13:43 Sent To  
Notes
2008-06-10 14:27:32 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC CHAPTER 1 AS
 AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: ALL
 COMMENTS RELATE TO SHEET E-1 UNLESS OTHERWISE NOTED.
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471
 FS, RESPECTIVELY.
 THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL
 IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES,
 IF EXEMPTIONS APPLY.
  
 2} THIS PROJECT MUST COMPLY WITH CHAPTER 13 FBC. SEE
 13-415.1ABC.1.1FOR TIME CLOCK REQUIREMENTS AND.FOR
 LIGHTING DENSITIES ALL THAT IS REQUIRED FOR THE
 ELECTRICAL REVIEW IS THE BASIC PRESCRIPTIVE
 REQUIREMENTS. SEE 13-415.2.ABC.1 PERFORMANCE
 CALCULATION PROCEDURES, GENERAL.
 THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR
 A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING
 SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD
 DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE
 METHOD DESCRIBED IN SECTION 415.2.B.1.THE INSTALLED
 INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH
 SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR
 LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH
 SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE
 DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF
 THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE
 DENSITY REQUIREMENTS.INDICATE WATTAGES ON THE FIXTURE
 SCHEDULE.
  
 3} INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBCSPACE
 CONTROLS FOR LIGHTING.
  
 4} SHOW COMPLIANCE WITH210.63 HEATING,
 AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT OUTLET A
 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED
 RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
 LOCATION FOR THE SERVICING OF HEATING,
 AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE
 RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND
 WITHIN 7.5 M (25 FT) OF THE HEATING, AIR-CONDITIONING,
 AND REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET
 SHALL NOT BE CONNECTED TO THE LOAD SIDE OF THE
 EQUIPMENT DISCONNECTING MEANS. THIS COMMENT IS IN
 REGARD TO THE ROOF CONDENSING UNITS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2008-12-08 Cont ID  
Sent By mawillia Date 2008-12-08 Time 13:50 Rev Time 0.00
Received By mawillia Date 2008-12-08 Time 12:43 Sent To  
Notes
2008-12-08 13:49:57*****REVISION APPROVED*****
  
 REVISED PLAN SHEET A-1 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-09-09 Cont ID  
Sent By mawillia Date 2008-09-09 Time 11:09 Rev Time 0.00
Received By mawillia Date 2008-09-09 Time 10:46 Sent To  
Notes
2008-09-09 10:52:38*****APPROVED*****
  
 PLAN SHEETS A-1 AND E-1 (THAT WERE PREVIOUSLY STAMPED
 ON 8/14/2008) WERE RE-STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-08-14 Cont ID  
Sent By mawillia Date 2008-08-14 Time 10:47 Rev Time 0.00
Received By mawillia Date 2008-08-14 Time 10:19 Sent To  
Notes
2008-08-14 10:47:33*****APPROVED*****
  
 ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED; PLAN SHEETS A-1 AND E-1 WERE STAMPED,
 INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-06-12 Cont ID  
Sent By mwennerg Date 2008-06-12 Time 14:55 Rev Time 0.00
Received By mwennerg Date 2008-06-12 Time 14:55 Sent To  
Notes
2008-06-12 15:05:04***DENIED***
  
 1) PROVIDE LAYOUT OF FIRE SPRINKLER SYSTEM. IN
 ADDITION, SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED
 FOR FIRE SPRINKLER SYSTEM PRIOR TO INSTALLATION OF
 EQUIPMENT.
  
 2) DOES THE DISTANCE BETWEEN THE TWO EXITS IN THE
 DINING ROOM MEET THE REQUIREMENTS OF NFPA 101, SEC.
 7.5.1.3.3?
  
 3) PANEL LAYOUT REFERENCES A HOOD SUPPLY FAN. IS THAT
 EQUIPMENT A GREASE HOOD OR AN EXHAUST FAN FOR THE
 INVECTION OVEN? PLEASE CLARIFY
  
 4) 2A-10B,C RATED FIRE EXTINGUISHER(S) REQUIRED.
  
 5) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION.
  
 6) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-11-26 Cont ID  
Sent By adarroug Date 2008-11-26 Time 16:14 Rev Time 0.00
Received By adarroug Date 2008-11-26 Time 16:09 Sent To  
Notes
2008-12-01 16:58:29TO "BOB"#16
2008-11-26 16:16:04WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-09-03 Cont ID  
Sent By adarroug Date 2008-09-03 Time 10:45 Rev Time 0.00
Received By adarroug Date 2008-09-03 Time 10:45 Sent To  
Notes
2008-09-03 10:45:55TO "BOB"#7

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-07-28 Cont ID  
Sent By adarroug Date 2008-07-28 Time 14:20 Rev Time 0.00
Received By adarroug Date 2008-07-28 Time 14:20 Sent To  
Notes
2008-08-08 11:20:35TO "BOB"#15
2008-07-28 14:20:50WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-16 Cont ID  
Sent By mperson Date 2008-06-16 Time 15:18 Rev Time 0.00
Received By mperson Date 2008-06-04 Time 14:40 Sent To PC
Notes
2008-06-04 14:43:08TO "BOB"#10

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-12-14 Cont ID  
Sent By rregueir Date 2008-12-14 Time 10:51 Rev Time 0.00
Received By rregueir Date 2008-12-14 Time 10:50 Sent To PC
Notes
2008-12-14 10:51:12PAGE A1, REVISED SIZED OF WALK-IN COOLER AND FREEZER.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-06-11 Cont ID  
Sent By tgordon Date 2008-06-11 Time 16:03 Rev Time 0.25
Received By tgordon Date 2008-06-11 Time 16:03 Sent To  
Notes
2008-06-11 16:11:12ADDITIONAL MECHANICAL PERMITS REQUIRED FOR
 (1) WALK-IN-FREEZER.
  
 ** SUBMIT DETAILED MANUFACTURER'S SPECIFICATION'S AND
 INSTALLATION INSTRUCTIONS WHEN APPLING FOR PERMIT.
  
 NO MECHANICAL PLANS SUBMITTED, AND NO MECHANICAL
 PERMIT NUMBER APPLIED FOR AT THIS TIME.

Review Stop P PLUMBING
Rev No 4 Status N Date 2008-12-11 Cont ID  
Sent By kstevens Date 2008-12-11 Time 14:35 Rev Time 0.00
Received By kstevens Date 2008-12-11 Time 14:35 Sent To  
Notes
2008-12-11 14:35:35NO PLUMBING REVISIONS INDICATED

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-09-09 Cont ID  
Sent By mperson Date 2008-09-09 Time 15:10 Rev Time 0.00
Received By mperson Date 2008-09-09 Time 15:10 Sent To  
Notes
2008-09-09 15:25:53****************PROVISO****************
 SHEET M-1 NEEDS TO BE REVISED BEFORE FINAL TO REFLECT
 THE FOLLOWING:
  
 A} CHANGE TRAPZILLA MODEL TZ-325 TO TRAPZILLA MODEL
 TZ-400. PER RODNEY COMPO (ENVIRONMENTAL COMPLIANCE) AND
 FBC-2004 PLUMBING SECTION 701.1 SCOPE.
  
 B} CLEARLY INDICATE THAT FIXTURES P-6 (TRIPLE SINK) AND
 P-8 (BAR SINK) SHALL DISCHARGE THROUGH AN INDIRECT
 WASTE PIPE BY MEANS OF AN AIR GAP. PER FBC-2004
 PLUMBING SECTION 802.1.1 FOOD HANDLING.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-08-12 Cont ID  
Sent By mperson Date 2008-08-12 Time 11:03 Rev Time 0.00
Received By mperson Date 2008-08-12 Time 11:03 Sent To  
Notes
2008-08-12 11:59:15PLUMBING PLAN REVIEW:
 DENIED **2ND TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 THE PREVIOUS PLUMBING REVIEW COMMENTS AS WLLAS THE
 DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. NEW
 COMMENTS WILL BE SO NOTED FOLLOWING THE PREVIOUS REVIEW
 COMMENTS.
  
 1. SHEET A-1 AND M-1 CLEARLY IDENTIFY ALL PLUMBING
 FIXTURES EXISTING AND PROPOSED WITH A FIXTURE
 SCHEDULE.
 NOTE: SOME FIXTURES THAT ARE BEING INDICATED ON SHEET
 M-1 EXISTING WATER AND SANITARY ISOMETRICS ARE NOT
 CLEARLY INDENTIFIED ON SHEET A-1 (P3, THREE HAND SINKS,
 WASHER). IF THESE FIXTURES ARE NOT ON THE NEW FLOOR
 PLAN THEY SHOULD BE DELETED TO AVOID FUTHER CONFUSION.
 PER FBC- PLUMBING SCTION 401.1 SCOPE, 601.1 SCOPE AND
 701.1 SCOPE.
  
 **RESPONSE NOTED, HOWEVER ON RESUBMITTED PLAN SHEET
 M-1 WATER ISOMETRIC THERE ARE STILL TWO FIXTURES THAT
 ARE NOT CLEARLY IDENTIFIED. THERE IS ALSO A BAR SINK
 BEING IDENTIFIED ON THE WATER ISOMETRIC, HOWEVER THIS
 SINK IS NOT ON THE PLUMBING FIXTURE SCHEDULE. PLEASE
 KNOW THAT THIS FIXTURE IS BEING IDENTIFIED ON THE
 SANITARY ISOMETRIC AND THE FIXTURE SCHEDULE AS A P-8
 HAND SINK. PLEASE KNOW THAT NOW THE MOP SINK IS BEING
 CLEARLY IDENTIFIED THAT IT NEEDS TO DRAIN INTO THE
 GREASE SYSTEM AND THE FLOW RATE TO THE GREASE TRAP SO
 NOTED ON THE FIXTURE SCHEDULE. PLEASE CORRECT AND
 CORRELATE THESE ITEMS PER FBC-2004 PLUMBING SECTIONS
 401.1 SCOPE, 601.1 SCOPE AND 701.1 SCOPE.
  
 2. "OK" COMMENT ADDRESSED.
  
 3. SHEETS A-1 AND M-1 ARE INDICATING AN EXISTING
 GREASE INTERCEPTOR IN SIDE OF THE RESTAURANT, HOWEVER
 THERE IS NO SIZE BEING INDICATED FOR THE INTERCEPTOR.
 CLEARLY INDICATE THE SIZE OF THE INTERCEPTOR. PER FBC-
 PLUMBING SECTION 701.1 SCOPE AND PLEASE PROVIDE THE
 FOLLOWING
 PER MUNICIPAL CODE ARTICLE III SECTION 90-124, THE
 EXISTING/PROPOSED GREASE INTERCEPTOR SHALL BE SIZED AND
 LOCATED BY ENVIRONMENTAL COMPLIANCE DIVISION OF THE
 UTILITY DEPARTMENT. PLEASE CONTACT RODNEY COMPO, PHONE:
 (561) 822-2272, E-MAIL: [email protected] THE FAX NUMBER
 IS (561) 822-2287. NOTE: WRITTEN APPROVAL IS REQUIRED
 OF THE EXISTING/PROPOSED GREASE INTERCEPTOR FROM
 ENVIRONMENTAL COMPLIANCE BEFORE A PERMIT CAN BE
 ISSUED.
  
 **RESPONSE NOTED, HOWEVER PER E-MAIL BY RODNEY COMPO
 DATED 6/24/08 IT STATES THAT HE INSPECTED THE THE SITE
 AND THAT IT HAS AN OLD IN FLOOR GREASE TRAP. TRAP NEEDS
 TO BE UPDATED AND MOVED TO THE OUTSIDE, NEXT TO THE CAN
 WASH NEXT TO OR UNDER THE STAIRWAY. HE DOES SUGGEST
 THAT A TRAPZILLA SUPERCAPACITY GREASE TRAP WOULD WORK
 IN THIS LOCATION. PLEASE KNOW THAT PER MUNICIPAL CODE
 SECTION 90-124(7)(B) GREASE INTERCEPTORS (GREASE TRAPS)
 ARE TO BE INSTALLED OUTSIDE OF THE FOOD PREPERATION
 AREA. PLEASE KNOW THAT PER RODNEY COMPO'S ON SITE
 INSPECTION REVIEW AND THE MUNICIPAL CODE THE NEW
 TRAPZILLA SHALL BE LOCATED OUTSIDE.
  
 **THE FOLLOWING ARE NEW COMMENTS**
  
 4. SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR
 (4) TIMES THE FEE.
  
 5. SHEET M-1 WATER ISOMETRIC: CLEARLY INDICATE ON THE
 PLANS THAT THE DEVICES INDICATED FOR WATER HAMMER
 PROTECTION FOR THE FIXTURES ARE WATER-HAMMER ARRESTORS
 AND THAT THEY ARE NOT AIR CHAMBERS. PLEASE KNOW THAT
 AIR CHAMBERS ARE NOT APPROVED BY THE FBC-2004 PLUMBING
 SECTION 604.9 WATER HAMMER.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-06-16 Cont ID  
Sent By mperson Date 2008-06-16 Time 14:34 Rev Time 0.00
Received By mperson Date 2008-06-16 Time 14:34 Sent To I
Notes
2008-06-16 15:18:10PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A-1 AND M-1 CLEARLY IDENTIFY ALL PLUMBING
 FIXTURES EXISTING AND PROPOSED WITH A FIXTURE
 SCHEDULE.
 NOTE: SOME FIXTURES THAT ARE BEING INDICATED ON SHEET
 M-1 EXISTING WATER AND SANITARY ISOMETRICS ARE NOT
 CLEARLY INDENTIFIED ON SHEET A-1 (P3, THREE HAND SINKS,
 WASHER). IF THESE FIXTURES ARE NOT ON THE NEW FLOOR
 PLAN THEY SHOULD BE DELETED TO AVOID FUTHER CONFUSION.
 PER FBC- PLUMBING SCTION 401.1 SCOPE, 601.1 SCOPE AND
 701.1 SCOPE.
  
 2. SHEET M-1 EXISTING WATER AND SANITARY ISOMETRICS.
 DELETE THE CLOUDED HAND SINK THAT STATES IT WAS OMITTED
 FROM THE DEMO PLAN.
 NOTE: THERE IS NO DEMO PLAN WITH THIS SET OF DRAWINGS
 AND THIS BEING ON THE PROPOSED PLANS IS CONFUSING. PER
 FBC - PLUMBING SECTION 601.1 SCOPE AND 701.1 SCOPE.
  
 3. SHEETS A-1 AND M-1 ARE INDICATING AN EXISTING
 GREASE INTERCEPTOR IN SIDE OF THE RESTAURANT, HOWEVER
 THERE IS NO SIZE BEING INDICATED FOR THE INTERCEPTOR.
 CLEARLY INDICATE THE SIZE OF THE INTERCEPTOR. PER FBC-
 PLUMBING SECTION 701.1 SCOPE AND PLEASE PROVIDE THE
 FOLLOWING
 PER MUNICIPAL CODE ARTICLE III SECTION 90-124, THE
 EXISTING/PROPOSED GREASE INTERCEPTOR SHALL BE SIZED AND
 LOCATED BY ENVIRONMENTAL COMPLIANCE DIVISION OF THE
 UTILITY DEPARTMENT. PLEASE CONTACT RODNEY COMPO, PHONE:
 (561) 822-2272, E-MAIL: [email protected] THE FAX NUMBER
 IS (561) 822-2287. NOTE: WRITTEN APPROVAL IS REQUIRED
 OF THE EXISTING/PROPOSED GREASE INTERCEPTOR FROM
 ENVIRONMENTAL COMPLIANCE BEFORE A PERMIT CAN BE
 ISSUED.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-06-06 Cont ID  
Sent By choops Date 2008-06-06 Time 13:45 Rev Time 0.00
Received By choops Date 2008-06-06 Time 13:45 Sent To  
Notes
2008-06-06 13:45:25*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved