| Plan Review Stops For Permit 08060046 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-12-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-12-03 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-12-03 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-09-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-09-11 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-09-11 |
Time |
07:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-08-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-08-13 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-08-13 |
Time |
06:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-11 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-11 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2008-06-11 14:51:41 | BUILDING PLAN REVIEW | | | PERMIT: 08060046 | | | ADD: 105 S. NARCISSUS AVE. #130 | | | CONT: POINTE SITE DEV. CONST. | | | TEL: (561)792-4313 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 2)FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 4) 2004 FBC EXISTING 301.5.A DESIGN PROFESSIONAL OR | | | AN OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF | | | THIS CODE. | | | | | | 5)A FIRE SPRINKLER PLAN IS REQUIRED TO SHOW HOW THE | | | RENOVATION HAS AFFECTED THE LAYOUT OF THE EXISTING | | | HEADS. YOU MAY SHOW THIS INFORMATION ON THE REFLECTED | | | CEILING PLANS. 106.3.5.1.1(5) | | | | | | 6)INDICATE THE ACCESSIBILITY SEATING ON THE PLANS | | | WHICH SHALL MEET THE REQUIREMENTS OF SECTION 11-5, | | | 11-4.32 AND 11-4.33 | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-12-08 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-12-05 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-09-03 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-09-03 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-14 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-14 |
Time |
14:06 |
Sent To |
PC |
|
| Notes |
| 2008-08-14 15:14:17 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC CHAPTER 1 AS | | | AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: ALL | | | COMMENTS RELATE TO SHEET E-1 UNLESS OTHERWISE NOTED. | | | | | | THESE ARE REPEAT COMMENTS FROM THE PREVIOUS REVIEW, | | | ***INDICATES FURTHER EXPLANATION OF COMMENT, SHEET | | | E-1. | | | | | | 2} THIS PROJECT MUST COMPLY WITH CHAPTER 13 FBC. SEE | | | 13-415.1ABC.1.1FOR TIME CLOCK REQUIREMENTS AND.FOR | | | LIGHTING DENSITIES ALL THAT IS REQUIRED FOR THE | | | ELECTRICAL REVIEW IS THE BASIC PRESCRIPTIVE | | | REQUIREMENTS. SEE 13-415.2.ABC.1 PERFORMANCE | | | CALCULATION PROCEDURES, GENERAL. | | | THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR | | | A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | | SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD | | | DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE | | | METHOD DESCRIBED IN SECTION 415.2.B.1.THE INSTALLED | | | INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH | | | SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR | | | LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | | SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE | | | DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF | | | THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE | | | DENSITY REQUIREMENTS.INDICATE WATTAGES ON THE FIXTURE | | | SCHEDULE.***THE WATTAGES PER SQUARE FOOT EXCEED THE | | | MAXIMUM ALLOWED, NO TIME CLOCK IS SHOWN ON THE PLAN | | | | | | 3} INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBCSPACE | | | CONTROLS FOR LIGHTING.***13-415.1.ABC.1.2 SPACE | | | CONTROL. | | | EACH SPACE ENCLOSED BY CEILING-HEIGHT PARTITIONS SHALL | | | HAVE AT LEAST ONE CONTROL DEVICE TO INDEPENDENTLY | | | CONTROL THE GENERAL LIGHTING WITHIN THE SPACE. EACH | | | MANUAL DEVICE SHALL BE READILY ACCESSIBLE AND LOCATED | | | SO THE OCCUPANTS CAN SEE THE CONTROLLED LIGHTING. | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-06-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-10 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-10 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2008-06-10 14:27:32 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC CHAPTER 1 AS | | | AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: ALL | | | COMMENTS RELATE TO SHEET E-1 UNLESS OTHERWISE NOTED. | | | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471 | | | FS, RESPECTIVELY. | | | THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL | | | IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES, | | | IF EXEMPTIONS APPLY. | | | | | | 2} THIS PROJECT MUST COMPLY WITH CHAPTER 13 FBC. SEE | | | 13-415.1ABC.1.1FOR TIME CLOCK REQUIREMENTS AND.FOR | | | LIGHTING DENSITIES ALL THAT IS REQUIRED FOR THE | | | ELECTRICAL REVIEW IS THE BASIC PRESCRIPTIVE | | | REQUIREMENTS. SEE 13-415.2.ABC.1 PERFORMANCE | | | CALCULATION PROCEDURES, GENERAL. | | | THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR | | | A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | | SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD | | | DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE | | | METHOD DESCRIBED IN SECTION 415.2.B.1.THE INSTALLED | | | INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH | | | SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR | | | LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | | SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE | | | DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF | | | THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE | | | DENSITY REQUIREMENTS.INDICATE WATTAGES ON THE FIXTURE | | | SCHEDULE. | | | | | | 3} INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBCSPACE | | | CONTROLS FOR LIGHTING. | | | | | | 4} SHOW COMPLIANCE WITH210.63 HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT OUTLET A | | | 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE | | | RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND | | | WITHIN 7.5 M (25 FT) OF THE HEATING, AIR-CONDITIONING, | | | AND REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET | | | SHALL NOT BE CONNECTED TO THE LOAD SIDE OF THE | | | EQUIPMENT DISCONNECTING MEANS. THIS COMMENT IS IN | | | REGARD TO THE ROOF CONDENSING UNITS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-12-08 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-12-08 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2008-12-08 13:49:57 | *****REVISION APPROVED***** | | | | | | REVISED PLAN SHEET A-1 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-09-09 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-09-09 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2008-09-09 10:52:38 | *****APPROVED***** | | | | | | PLAN SHEETS A-1 AND E-1 (THAT WERE PREVIOUSLY STAMPED | | | ON 8/14/2008) WERE RE-STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-14 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-08-14 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2008-08-14 10:47:33 | *****APPROVED***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED; PLAN SHEETS A-1 AND E-1 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-06-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-12 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-12 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2008-06-12 15:05:04 | ***DENIED*** | | | | | | 1) PROVIDE LAYOUT OF FIRE SPRINKLER SYSTEM. IN | | | ADDITION, SEPARATE SHOP DRAWINGS AND PERMIT REQUIRED | | | FOR FIRE SPRINKLER SYSTEM PRIOR TO INSTALLATION OF | | | EQUIPMENT. | | | | | | 2) DOES THE DISTANCE BETWEEN THE TWO EXITS IN THE | | | DINING ROOM MEET THE REQUIREMENTS OF NFPA 101, SEC. | | | 7.5.1.3.3? | | | | | | 3) PANEL LAYOUT REFERENCES A HOOD SUPPLY FAN. IS THAT | | | EQUIPMENT A GREASE HOOD OR AN EXHAUST FAN FOR THE | | | INVECTION OVEN? PLEASE CLARIFY | | | | | | 4) 2A-10B,C RATED FIRE EXTINGUISHER(S) REQUIRED. | | | | | | 5) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION. | | | | | | 6) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH NFPA 241. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-11-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-26 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-26 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2008-12-01 16:58:29 | TO "BOB"#16 | | 2008-11-26 16:16:04 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-03 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-03 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2008-09-03 10:45:55 | TO "BOB"#7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-28 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-28 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2008-08-08 11:20:35 | TO "BOB"#15 | | 2008-07-28 14:20:50 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-16 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-04 |
Time |
14:40 |
Sent To |
PC |
|
| Notes |
| 2008-06-04 14:43:08 | TO "BOB"#10 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-12-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-14 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-14 |
Time |
10:50 |
Sent To |
PC |
|
| Notes |
| 2008-12-14 10:51:12 | PAGE A1, REVISED SIZED OF WALK-IN COOLER AND FREEZER. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-11 |
Time |
16:03 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-06-11 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2008-06-11 16:11:12 | ADDITIONAL MECHANICAL PERMITS REQUIRED FOR | | | (1) WALK-IN-FREEZER. | | | | | | ** SUBMIT DETAILED MANUFACTURER'S SPECIFICATION'S AND | | | INSTALLATION INSTRUCTIONS WHEN APPLING FOR PERMIT. | | | | | | NO MECHANICAL PLANS SUBMITTED, AND NO MECHANICAL | | | PERMIT NUMBER APPLIED FOR AT THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2008-12-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-11 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-11 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2008-12-11 14:35:35 | NO PLUMBING REVISIONS INDICATED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-09-09 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-09-09 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2008-09-09 15:25:53 | ****************PROVISO**************** | | | SHEET M-1 NEEDS TO BE REVISED BEFORE FINAL TO REFLECT | | | THE FOLLOWING: | | | | | | A} CHANGE TRAPZILLA MODEL TZ-325 TO TRAPZILLA MODEL | | | TZ-400. PER RODNEY COMPO (ENVIRONMENTAL COMPLIANCE) AND | | | FBC-2004 PLUMBING SECTION 701.1 SCOPE. | | | | | | B} CLEARLY INDICATE THAT FIXTURES P-6 (TRIPLE SINK) AND | | | P-8 (BAR SINK) SHALL DISCHARGE THROUGH AN INDIRECT | | | WASTE PIPE BY MEANS OF AN AIR GAP. PER FBC-2004 | | | PLUMBING SECTION 802.1.1 FOOD HANDLING. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-12 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-12 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2008-08-12 11:59:15 | PLUMBING PLAN REVIEW: | | | DENIED **2ND TIME: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | THE PREVIOUS PLUMBING REVIEW COMMENTS AS WLLAS THE | | | DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. NEW | | | COMMENTS WILL BE SO NOTED FOLLOWING THE PREVIOUS REVIEW | | | COMMENTS. | | | | | | 1. SHEET A-1 AND M-1 CLEARLY IDENTIFY ALL PLUMBING | | | FIXTURES EXISTING AND PROPOSED WITH A FIXTURE | | | SCHEDULE. | | | NOTE: SOME FIXTURES THAT ARE BEING INDICATED ON SHEET | | | M-1 EXISTING WATER AND SANITARY ISOMETRICS ARE NOT | | | CLEARLY INDENTIFIED ON SHEET A-1 (P3, THREE HAND SINKS, | | | WASHER). IF THESE FIXTURES ARE NOT ON THE NEW FLOOR | | | PLAN THEY SHOULD BE DELETED TO AVOID FUTHER CONFUSION. | | | PER FBC- PLUMBING SCTION 401.1 SCOPE, 601.1 SCOPE AND | | | 701.1 SCOPE. | | | | | | **RESPONSE NOTED, HOWEVER ON RESUBMITTED PLAN SHEET | | | M-1 WATER ISOMETRIC THERE ARE STILL TWO FIXTURES THAT | | | ARE NOT CLEARLY IDENTIFIED. THERE IS ALSO A BAR SINK | | | BEING IDENTIFIED ON THE WATER ISOMETRIC, HOWEVER THIS | | | SINK IS NOT ON THE PLUMBING FIXTURE SCHEDULE. PLEASE | | | KNOW THAT THIS FIXTURE IS BEING IDENTIFIED ON THE | | | SANITARY ISOMETRIC AND THE FIXTURE SCHEDULE AS A P-8 | | | HAND SINK. PLEASE KNOW THAT NOW THE MOP SINK IS BEING | | | CLEARLY IDENTIFIED THAT IT NEEDS TO DRAIN INTO THE | | | GREASE SYSTEM AND THE FLOW RATE TO THE GREASE TRAP SO | | | NOTED ON THE FIXTURE SCHEDULE. PLEASE CORRECT AND | | | CORRELATE THESE ITEMS PER FBC-2004 PLUMBING SECTIONS | | | 401.1 SCOPE, 601.1 SCOPE AND 701.1 SCOPE. | | | | | | 2. "OK" COMMENT ADDRESSED. | | | | | | 3. SHEETS A-1 AND M-1 ARE INDICATING AN EXISTING | | | GREASE INTERCEPTOR IN SIDE OF THE RESTAURANT, HOWEVER | | | THERE IS NO SIZE BEING INDICATED FOR THE INTERCEPTOR. | | | CLEARLY INDICATE THE SIZE OF THE INTERCEPTOR. PER FBC- | | | PLUMBING SECTION 701.1 SCOPE AND PLEASE PROVIDE THE | | | FOLLOWING | | | PER MUNICIPAL CODE ARTICLE III SECTION 90-124, THE | | | EXISTING/PROPOSED GREASE INTERCEPTOR SHALL BE SIZED AND | | | LOCATED BY ENVIRONMENTAL COMPLIANCE DIVISION OF THE | | | UTILITY DEPARTMENT. PLEASE CONTACT RODNEY COMPO, PHONE: | | | (561) 822-2272, E-MAIL: [email protected] THE FAX NUMBER | | | IS (561) 822-2287. NOTE: WRITTEN APPROVAL IS REQUIRED | | | OF THE EXISTING/PROPOSED GREASE INTERCEPTOR FROM | | | ENVIRONMENTAL COMPLIANCE BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | **RESPONSE NOTED, HOWEVER PER E-MAIL BY RODNEY COMPO | | | DATED 6/24/08 IT STATES THAT HE INSPECTED THE THE SITE | | | AND THAT IT HAS AN OLD IN FLOOR GREASE TRAP. TRAP NEEDS | | | TO BE UPDATED AND MOVED TO THE OUTSIDE, NEXT TO THE CAN | | | WASH NEXT TO OR UNDER THE STAIRWAY. HE DOES SUGGEST | | | THAT A TRAPZILLA SUPERCAPACITY GREASE TRAP WOULD WORK | | | IN THIS LOCATION. PLEASE KNOW THAT PER MUNICIPAL CODE | | | SECTION 90-124(7)(B) GREASE INTERCEPTORS (GREASE TRAPS) | | | ARE TO BE INSTALLED OUTSIDE OF THE FOOD PREPERATION | | | AREA. PLEASE KNOW THAT PER RODNEY COMPO'S ON SITE | | | INSPECTION REVIEW AND THE MUNICIPAL CODE THE NEW | | | TRAPZILLA SHALL BE LOCATED OUTSIDE. | | | | | | **THE FOLLOWING ARE NEW COMMENTS** | | | | | | 4. SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR | | | (4) TIMES THE FEE. | | | | | | 5. SHEET M-1 WATER ISOMETRIC: CLEARLY INDICATE ON THE | | | PLANS THAT THE DEVICES INDICATED FOR WATER HAMMER | | | PROTECTION FOR THE FIXTURES ARE WATER-HAMMER ARRESTORS | | | AND THAT THEY ARE NOT AIR CHAMBERS. PLEASE KNOW THAT | | | AIR CHAMBERS ARE NOT APPROVED BY THE FBC-2004 PLUMBING | | | SECTION 604.9 WATER HAMMER. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-16 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-16 |
Time |
14:34 |
Sent To |
I |
|
| Notes |
| 2008-06-16 15:18:10 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET A-1 AND M-1 CLEARLY IDENTIFY ALL PLUMBING | | | FIXTURES EXISTING AND PROPOSED WITH A FIXTURE | | | SCHEDULE. | | | NOTE: SOME FIXTURES THAT ARE BEING INDICATED ON SHEET | | | M-1 EXISTING WATER AND SANITARY ISOMETRICS ARE NOT | | | CLEARLY INDENTIFIED ON SHEET A-1 (P3, THREE HAND SINKS, | | | WASHER). IF THESE FIXTURES ARE NOT ON THE NEW FLOOR | | | PLAN THEY SHOULD BE DELETED TO AVOID FUTHER CONFUSION. | | | PER FBC- PLUMBING SCTION 401.1 SCOPE, 601.1 SCOPE AND | | | 701.1 SCOPE. | | | | | | 2. SHEET M-1 EXISTING WATER AND SANITARY ISOMETRICS. | | | DELETE THE CLOUDED HAND SINK THAT STATES IT WAS OMITTED | | | FROM THE DEMO PLAN. | | | NOTE: THERE IS NO DEMO PLAN WITH THIS SET OF DRAWINGS | | | AND THIS BEING ON THE PROPOSED PLANS IS CONFUSING. PER | | | FBC - PLUMBING SECTION 601.1 SCOPE AND 701.1 SCOPE. | | | | | | 3. SHEETS A-1 AND M-1 ARE INDICATING AN EXISTING | | | GREASE INTERCEPTOR IN SIDE OF THE RESTAURANT, HOWEVER | | | THERE IS NO SIZE BEING INDICATED FOR THE INTERCEPTOR. | | | CLEARLY INDICATE THE SIZE OF THE INTERCEPTOR. PER FBC- | | | PLUMBING SECTION 701.1 SCOPE AND PLEASE PROVIDE THE | | | FOLLOWING | | | PER MUNICIPAL CODE ARTICLE III SECTION 90-124, THE | | | EXISTING/PROPOSED GREASE INTERCEPTOR SHALL BE SIZED AND | | | LOCATED BY ENVIRONMENTAL COMPLIANCE DIVISION OF THE | | | UTILITY DEPARTMENT. PLEASE CONTACT RODNEY COMPO, PHONE: | | | (561) 822-2272, E-MAIL: [email protected] THE FAX NUMBER | | | IS (561) 822-2287. NOTE: WRITTEN APPROVAL IS REQUIRED | | | OF THE EXISTING/PROPOSED GREASE INTERCEPTOR FROM | | | ENVIRONMENTAL COMPLIANCE BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-06 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-06 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2008-06-06 13:45:25 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|