Plan Review Details - Permit 08050822
| Plan Review Stops For Permit 08050822 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-06-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-17 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-17 |
Time |
09:06 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-11 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-11 |
Time |
07:31 |
Sent To |
I |
|
| Notes |
| 2008-06-11 07:38:10 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1 | | | AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} PLEASE SUBMIT A FLOOR PLAN AND INDICATING THE | | | LOCATION OF ALL EQUIPMENT AND DEVICES BEING INSTALLED | | | UNDER THE SCOPE OF THIS APPLICATION.106.1.1 FBC. . ALSO | | | SHOW COMPLIANCE WITH THE REQUIRED DISCONNECT PER | | | 440.14,RECEPTACLE PER 210.63, LIGHT PER 210.70(A) | | | (3). | | | | | | 2} PROVIDE LOAD CALCULATIONS PER ARTICLE 220 PART III, | | | STANDARD OR PART IV OPTIONAL,INCLUDE ADDED LOADS | | | INDICATE EXISTING SERVICE SIZE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-16 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-16 |
Time |
15:45 |
Sent To |
E |
|
| Notes |
| 2008-06-16 15:45:57 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-11 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-05 |
Time |
08:48 |
Sent To |
PC |
|
| Notes |
| 2008-06-05 08:48:41 | TO "M" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-17 |
Time |
11:41 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-06-17 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-05 |
Time |
14:06 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-06-05 |
Time |
14:06 |
Sent To |
E |
|
| Notes |
| 2008-06-05 14:21:59 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLEASE SUBMIT A FLOOR PLAN SHOWING WHERE EACH PIECE | | | OF EQUIPMENT IS GOING AND SHOW THE EQUIPMENT SCHEDULE, | | | PER 2004 WPB AMEND. 106.3.5.4 (10). | | | | | | 2) PLEASE SUBMIT DETAILED MANUFACTURER'S | | | SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR THE | | | A/C SYSTEMS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
|