Plan Review Details - Permit 08050714
Plan Review Stops For Permit 08050714
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-06-05 Cont ID  
Sent By jgomez Date 2008-06-05 Time 14:16 Rev Time 0.00
Received By jgomez Date 2008-06-05 Time 14:16 Sent To PC
Notes
2008-06-05 14:21:16BUILDING REVIEW APPROVED WITH PROVISO:
 1-NAIL1X4 BATTENSUSING #9 (3-1/2") WOOD SCREWS AT
 7" AT PERIMETER & CORNER AREASPER MEETING WITH LARRY
 HERNSTON (CONTRACTOR) AND ROBERT BROWN.JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-06-03 Cont ID  
Sent By jgomez Date 2008-06-03 Time 13:09 Rev Time 0.00
Received By jgomez Date 2008-06-03 Time 13:09 Sent To  
Notes
2008-06-03 13:32:40RESIDENTIAL (R3) ROOF RECOVERING, BUILDING REVIEW
 CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 ***NOTE: PERMIT IS ON HOLD UNTIL FOLLOWING ISSUES ARE
 CLARIFIED.PLEASE DO NOT DO ANY WORK UNTILL PERMIT IS
 RE-ACTIVATED TO AVOID ANYCONFLICTS.
  
 1- PROVIDEPRODUCT APPROVAL FOR RECOVERING APPLICATION
 AS STATED ON PERMIT APPLICATION AS REQUIRED BY DCA RULE
 9B -72.NOA 07-0604.04 SUBMITTED IS FOR NEW
 CONSTRUCTION OR REROOF APPLICATION.SELECTED ASSEMBLY
 ON PAGE 7 OF NOA SUBMITTED IS FOR A WOOD NON-INSULATED
 DECK.CONTRACTOR IS SUBMITTING INSULATION
 INFORMATION.ANY MODIFICATIONS TO THE NOA VOID THE
 PRODUCT APPROVAL. SEE NOTE #3 ON GENERAL LIMITATIONS
 NOTES ON SHEET 15 OF NOA SUBMITTED.
  
 2- ACCORDING TO SEC. 511.4 OF 2004 FLORIDA EXISTING
 BUILDING CODEROOF RECOVERING OVER WOOD SHAKES
 REQUIRES THE ENTIRE EXISTING SURFACE TO BE COVERED WITH
 GYPSUM BOARD, MINERAL FIBER,GLASS FIBER OR OTHER
 APPROVED MATERIALS SECURELYFASTENED IN PLACE.RBI
 SHIELD IS A REFLECTIVE INSULATION AND NEEDS APPROVAL
 FROM BUILDING OFFICIAL.
  
 3- HOUSE IS LOCATED IN WIND EXPOSURE "C". SEE SEC.
 R301.2.1.4(3) OF 2004 FLORIDA RESIDENTIAL CODE. UPLIFT
 PRESSURES NEED TO BE TAKEN INTO CONSIDERATION FOR
 PROPOSED INSTALLATION.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2008-06-02 Cont ID  
Sent By jgomez Date 2008-06-02 Time 10:19 Rev Time 0.00
Received By jgomez Date 2008-06-02 Time 10:19 Sent To PC
Notes
2008-06-02 10:23:49RESIDENTIAL (R3) ROOF RECOVERING APPROVED WITH
 PROVISO:
 1- "THE ENTIRE EXISTING SURFACE SHALL BE COVERED WITH
 GYPSUM BOARD, MINERAL FIBER, GLASS FIBER OR OTHER
 APPROVED MATERIAL SECURELY FASTENED IN PLACE" AS
 REQUIRED BY SEC. 511.4 OF 2004 FLORIDA EXISTING
 BUILDING CODE.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-02 Cont ID  
Sent By jgomez Date 2008-06-02 Time 10:24 Rev Time 0.00
Received By jgomez Date 2008-06-02 Time 10:19 Sent To  
Notes
***NONE***