Plan Review Details - Permit 08050714
| Plan Review Stops For Permit 08050714 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-05 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-05 |
Time |
14:16 |
Sent To |
PC |
|
| Notes |
| 2008-06-05 14:21:16 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-NAIL1X4 BATTENSUSING #9 (3-1/2") WOOD SCREWS AT | | | 7" AT PERIMETER & CORNER AREASPER MEETING WITH LARRY | | | HERNSTON (CONTRACTOR) AND ROBERT BROWN.JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-03 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-03 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2008-06-03 13:32:40 | RESIDENTIAL (R3) ROOF RECOVERING, BUILDING REVIEW | | | CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | ***NOTE: PERMIT IS ON HOLD UNTIL FOLLOWING ISSUES ARE | | | CLARIFIED.PLEASE DO NOT DO ANY WORK UNTILL PERMIT IS | | | RE-ACTIVATED TO AVOID ANYCONFLICTS. | | | | | | 1- PROVIDEPRODUCT APPROVAL FOR RECOVERING APPLICATION | | | AS STATED ON PERMIT APPLICATION AS REQUIRED BY DCA RULE | | | 9B -72.NOA 07-0604.04 SUBMITTED IS FOR NEW | | | CONSTRUCTION OR REROOF APPLICATION.SELECTED ASSEMBLY | | | ON PAGE 7 OF NOA SUBMITTED IS FOR A WOOD NON-INSULATED | | | DECK.CONTRACTOR IS SUBMITTING INSULATION | | | INFORMATION.ANY MODIFICATIONS TO THE NOA VOID THE | | | PRODUCT APPROVAL. SEE NOTE #3 ON GENERAL LIMITATIONS | | | NOTES ON SHEET 15 OF NOA SUBMITTED. | | | | | | 2- ACCORDING TO SEC. 511.4 OF 2004 FLORIDA EXISTING | | | BUILDING CODEROOF RECOVERING OVER WOOD SHAKES | | | REQUIRES THE ENTIRE EXISTING SURFACE TO BE COVERED WITH | | | GYPSUM BOARD, MINERAL FIBER,GLASS FIBER OR OTHER | | | APPROVED MATERIALS SECURELYFASTENED IN PLACE.RBI | | | SHIELD IS A REFLECTIVE INSULATION AND NEEDS APPROVAL | | | FROM BUILDING OFFICIAL. | | | | | | 3- HOUSE IS LOCATED IN WIND EXPOSURE "C". SEE SEC. | | | R301.2.1.4(3) OF 2004 FLORIDA RESIDENTIAL CODE. UPLIFT | | | PRESSURES NEED TO BE TAKEN INTO CONSIDERATION FOR | | | PROPOSED INSTALLATION. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-02 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-02 |
Time |
10:19 |
Sent To |
PC |
|
| Notes |
| 2008-06-02 10:23:49 | RESIDENTIAL (R3) ROOF RECOVERING APPROVED WITH | | | PROVISO: | | | 1- "THE ENTIRE EXISTING SURFACE SHALL BE COVERED WITH | | | GYPSUM BOARD, MINERAL FIBER, GLASS FIBER OR OTHER | | | APPROVED MATERIAL SECURELY FASTENED IN PLACE" AS | | | REQUIRED BY SEC. 511.4 OF 2004 FLORIDA EXISTING | | | BUILDING CODE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-02 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-02 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
|