| Plan Review Stops For Permit 08050670 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-06-02 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-05-29 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2008-06-02 08:07:13 | ***PASSED*** | | | | | | THIS PERMIT IS ATTACHED TO A NEW SITE ADDRESS , THE NEW | | | SECOND SPACE MUST HAVE POSTED ON THE MAIN ENTRANCE THE | | | NEW SITE ADDRESS OF 1604 N FLORIDA MANGO RD, WEST PALM | | | BEACH , FL 33409. AN ADDRESS NOTIFICATION LETTER WILL | | | BE SENT OUT TO THE PROPERTY OWNER FOR THE NEW ADDRESS | | | . | | | | | | QUESTIONS/COMMENTS: | | | | | | LACRAMIOARA URSU, MA ,GISP | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-19 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-19 |
Time |
11:52 |
Sent To |
Z |
|
| Notes |
| 2008-12-19 11:53:59 | REVISION, ADD EXTERIOR WALL AND ROOF PANEL DEMO TO | | | SCOPE OF WORK | | | SHEETS S.00D, S.01D, S.02D, S.03D, S.04D | | | THRESHOLD INSPECTOR AGREEMENT AND INSPECTION PLAN | | | INCLUDED | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-17 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-17 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2008-12-17 17:49:23 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. PLANS SUBMITTED ARE NOT COMPLETE. SCOPE OF WORK IS | | | NOT SHOWN. THE COVER SHEET REFERS TO SHEETS S.00D | | | THROUGH S.04D, BUT ONLY S.00D WAS SUBMITTED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2008-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-03 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-03 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2008-12-03 14:26:21 | ****CORRECTIONS**** | | | ***REVISION, EXTERIOR DEMO*** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | FROM PREVIOUS LIST: | | | | | | 8. DUE TO OCCUPANT LOAD, THIS IS A THRESHOLD BUILDING | | | FS553.71. THRESHOLD INSPECTOR REQUIRED. PEASE ARRANGE | | | WITH KEN CONRAD (CHIEF BUILDING INSPECTOR, 561 805 | | | 6666), A MEETING INVOLVING THE OWNER, SPECIAL | | | INSPECTOR, JOB INSPECTOR, CONTRACTOR AND ENGINEER. THIS | | | MUST BE DONE PRIOR TO PERMIT ISSUANCE. THREE ORIGINAL | | | SETS OF ALL DOCUMENTS ARE REQUIRED FOR PERMITTING AND | | | FOR ALL SUBSEQUENT SUBMITTALS. SEE FBC*109.3.6. THIS | | | MUST BE DONE IMMEDIATELY OR A STOP WORK ORDER WILL BE | | | ISSUED. | | | | | | PLEASE CONTACT KEN CONRAD AS REQUESTED. UNTIL THE | | | THRESHOLD INSPECTOR HAS BEEN APPROVED, AND AN AGREEMENT | | | SIGNED BY ALL PARTIES AND INSPECTION PLAN APPROVED BY | | | K. CONRAD SUBMITTED, NO WORK IS TO BE PERFORMED ON THE | | | JOB AND NO REVISIONS/PERMITS WILL BE ISSUED. | | | | | | 9. PROVIDE A STRUCTURAL INSPECTION PLAN, FBC*109.3.6 | | | FOR THIS THRESHOLD BUILDING. | | | | | | THIS HAS BEEN ADDRESSED BUT THIS MUST BE APPROVED BY | | | KEN CONRAD. SEE OTHER COMMENTS. | | | | | | 10. SEE FBC*109.3.6.4.4 AND FS553.71 AND INCLUDE THE | | | STATEMENT ATTESTING TO COMPLIANCE. | | | | | | THIS WAS NOT DONE. THIS IS TYPICALLY PRINTED ON EACH | | | PLAN PAGE. | | | | | | NEW COMMENT: | | | | | | 11. NO REVISIONS OR PERMITS WILL BE ISSUED UNTIL ALL | | | ZONING ISSUES ARE RESOLVED, PER LUIS MARTINEZ. PLEASE | | | ADDRESS OTHER COMMENTS SO THAT THIS REVISION CAN BE | | | ISSUED WHEN OTHER ISSUES ARE RESOLVED. | | | | | | 12. AS YOU ARE PROPOSING TO REMOVE THE BUILDING | | | EXTERIOR BUT HAVE NOT PROVIDED ANY INFORMATION | | | REGARDING HOW THIS WILL BE REPAIRED, PLEASE PROVIDE | | | INFORMATION ON HOW THE BUILDING EXTERIOR WILL BE | | | REPAIRED OR EXPLAIN HOW THIS BUILDING WILL BE SECURED | | | FROM WEATHER, WATER INTRUSION, ETC. HOW LONG WILL THE | | | BUILDING SIT OPEN? | | | | | | 13. INFORMATIONAL ONLY - VALUE WILL BE ADJUSTED $22,000 | | | PER CONTRACTOR FOR ADDITIONAL VALUE. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2008-10-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-27 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-27 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2008-10-27 13:22:25 | ****CORRECTIONS**** | | | ***REVISION*** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | FROM PREVIOUS REVIEWS: | | | | | | 1. DECLARE GOVERNING CODE, INCLUDING 2007 | | | REVISIONS/SUPPLEMENTS. | | | | | | 2. DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 3. INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6, BUILDING | | | HEIGHT AND AREA FBC5, SPRINKLER INFORMATION, OCCUPANCY | | | CLASSIFICATION FBC 3 AND AREA PER OCCUPANCY. INCLUDE | | | EXISTING OCCUPANCY CLASSIFICATION AS WELL AS PROPOSED | | | OCCUPANCY CLASSIFICATION. | | | | | | 4. THE PLAN SHOWS REMOVAL OF WALL AND ROOF PANELS. A | | | DEMO PERMIT CANNOT BE ISSUED AS THIS AFFECTS THE | | | STRUCTURAL INTEGRITY OF THE BUILDING, FBC EB 501.2. | | | | | | 5. THIS PERMIT WAS FOR INTERIOR DEMO. OTHER PERMITS ARE | | | OPEN AND PENDING ON THIS BUILDING. PROVIDE A SITE PLAN | | | SHOWING THE LOCATION OF THE BUILDING, AS WELL AS | | | LOCATION OF THE TWO SPACES AND SCOPE OF WORK UNDER THE | | | DIFFERENT PERMITS. IT APPEARS THAT THIS WORK SHOULD BE | | | UNDER PERMIT 08090571, EXTERIOR REPAIRS. | | | | | | 6. PROVIDE A VALUE FOR THE ADDITIONAL WORK. | | | | | | 7. COMPLIANCE WITH REQUIREMENTS FOR EXITING FBC CHAPTER | | | 10, ENERGY FBC CHAPTER 13, ACCESSIBILITY FBC CHAPTER | | | 11, AND THRESHOLD BUILDING REQUIREMENTS CANNOT BE | | | DETERMINED. PROVIDE COMPLETE PLANS FOR ALL | | | IMPROVEMENTS, FBC*106. | | | | | | NEW COMMENTS: | | | | | | 8. DUE TO OCCUPANT LOAD, THIS IS A THRESHOLD BUILDING | | | FS553.71. THRESHOLD INSPECTOR REQUIRED. PEASE ARRANGE | | | WITH KEN CONRAD (CHIEF BUILDING INSPECTOR, 561 805 | | | 6666), A MEETING INVOLVING THE OWNER, SPECIAL | | | INSPECTOR, JOB INSPECTOR, CONTRACTOR AND ENGINEER. THIS | | | MUST BE DONE PRIOR TO PERMIT ISSUANCE. THREE ORIGINAL | | | SETS OF ALL DOCUMENTS ARE REQUIRED FOR PERMITTING AND | | | FOR ALL SUBSEQUENT SUBMITTALS. SEE FBC*109.3.6. THIS | | | MUST BE DONE IMMEDIATELY OR A STOP WORK ORDER WILL BE | | | ISSUED. | | | | | | 9. PROVIDE A STRUCTURAL INSPECTION PLAN, FBC*109.3.6 | | | FOR THIS THRESHOLD BUILDING. | | | | | | 10. SEE FBC*109.3.6.4.4 AND FS553.71 AND INCLUDE THE | | | STATEMENT ATTESTING TO COMPLIANCE. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-10-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-10-08 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-10-08 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2008-10-08 15:04:13 | ****CORRECTIONS**** | | | ***REVISION*** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | FROM FIRST REVIEW: | | | | | | 1. DECLARE GOVERNING CODE, INCLUDING 2007 | | | REVISIONS/SUPPLEMENTS. | | | | | | 2. DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 3. INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6, BUILDING | | | HEIGHT AND AREA FBC5, SPRINKLER INFORMATION, OCCUPANCY | | | CLASSIFICATION FBC 3 AND AREA PER OCCUPANCY. INCLUDE | | | EXISTING OCCUPANCY CLASSIFICATION AS WELL AS PROPOSED | | | OCCUPANCY CLASSIFICATION. | | | | | | 4. THE PLAN SHOWS REMOVAL OF WALL AND ROOF PANELS. A | | | DEMO PERMIT CANNOT BE ISSUED AS THIS AFFECTS THE | | | STRUCTURAL INTEGRITY OF THE BUILDING, FBC EB 501.2. | | | | | | 5. THIS PERMIT WAS FOR INTERIOR DEMO. OTHER PERMITS ARE | | | OPEN AND PENDING ON THIS BUILDING. PROVIDE A SITE PLAN | | | SHOWING THE LOCATION OF THE BUILDING, AS WELL AS | | | LOCATION OF THE TWO SPACES AND SCOPE OF WORK UNDER THE | | | DIFFERENT PERMITS. IT APPEARS THAT THIS WORK SHOULD BE | | | UNDER PERMIT 08090571, EXTERIOR REPAIRS. | | | | | | 6. PROVIDE A VALUE FOR THE ADDITIONAL WORK. | | | | | | 7. COMPLIANCE WITH REQUIREMENTS FOR EXITING FBC CHAPTER | | | 10, ENERGY FBC CHAPTER 13, ACCESSIBILITY FBC CHAPTER | | | 11, AND THRESHOLD BUILDING REQUIREMENTS CANNOT BE | | | DETERMINED. PROVIDE COMPLETE PLANS FOR ALL | | | IMPROVEMENTS, FBC*106. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-27 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-27 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-02 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-02 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2008-06-02 09:44:15 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.ALL INFORMATION REQUIRED BY FAC61G1-15.23.002,003 | | | IS TO BE ON EACH SHEET (CERTIFICATE OF AUTHORIZATION). | | | | | | 2.DECLARE GOVERNING CODE, INCLUDING 2007 | | | REVISIONS/SUPPLEMENTS. | | | | | | 3.DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 4.INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6, | | | BUILDING HEIGHT AND AREA FBC5, SPRINKLER INFORMATION, | | | OCCUPANCY CLASSIFICATION FBC 3 AND AREA PER OCCUPANCY. | | | INCLUDE EXISTING OCCUPANCY CLASSIFICATION AS WELL AS | | | PROPOSED OCCUPANCY CLASSIFICATION. | | | | | | 5.AN ICE PIT IS SHOWN, BUT NO DETAILS PROVIDED.WILL | | | THIS BE APPLIED FOR UNDER A SEPARATE PERMIT? | | | | | | 6.THE PLAN SHOWS REMOVAL OF WALL AND ROOF PANELS. | | | WILL THESE ITEMS BE REPLACED UNDER SEPARATE PERMIT? | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2009-05-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-05-05 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-05-05 |
Time |
11:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-19 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2008-12-19 11:54:31 | REVISION TO SMH DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-12-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-15 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-15 |
Time |
10:55 |
Sent To |
B |
|
| Notes |
| 2008-12-15 10:55:31 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-11-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-26 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-26 |
Time |
08:35 |
Sent To |
B |
|
| Notes |
| 2008-11-26 08:35:29 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-22 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-22 |
Time |
14:06 |
Sent To |
B |
|
| Notes |
| 2008-10-22 14:07:05 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-09-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-26 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-26 |
Time |
10:29 |
Sent To |
B |
|
| Notes |
| 2008-09-26 10:30:12 | TO "SHILL' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-19 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-19 |
Time |
11:48 |
Sent To |
B |
|
| Notes |
| 2008-06-19 11:49:06 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-02 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-23 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2008-05-23 15:43:18 | TO "MISC" BOX#1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-12-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2008-12-23 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2008-12-23 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2008-12-23 11:41:19 | ZONING PLAN REVIEW | | | | | | PERMIT NO.: 08050670 | | | ADDRESS: 1590 FLORIDA MANGO | | | CONTRACTOR/CONTACT: NAT HEALY | | | TELEPHONE NO.: (561) 635-6935 | | | | | | REVIEW STATUS: PASSED WITH PROVISO | | | | | | 1) THIS PERMIT IF FOR DEMOLITION ONLY! | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. | | | |
|
|