| 2008-05-27 15:19:55 | GAS PLAN REVIEW: |
| | DENIED: |
| | |
| | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| | (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| | |
| | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. |
| | |
| | 1. THE SUBMITTED GAS FLOOR PLAN IS A COPY OF MASTER |
| | PERMIT #07050618 THAT HAS AN ARCHITECTS TITLE BLOCK. |
| | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | FL ADMIN CODE 61G16.003 ARCHITECTS. NOTE: CONTRACTOR |
| | CAN SUBMIT AN ORIGINAL GAS FLOOR OF THEIR DESIGN. |
| | |
| | 2. THE SUBMITTED GAS ISOMETRIC DRAWING DOES NOT HAVE |
| | CORRESPONDING LENGTHS OR PIPING MATERIAL TO ALL CUT |
| | SECTIONS OF PIPE INDICATED. REFERENCE THE RED CIRCLED |
| | YELLOW HIGHLIGHTED CUT SECTIONS WITH NO CORRESPONDING |
| | LENGTHS OR PIPING MATERIAL INDICATED. PER FBC-2004 FUEL |
| | GAS SECTION 401.1 SCOPE. |
| | NOTE: IT APPEARS FROM THE FLOOR PLAN AND THE ISOMETRIC |
| | THAT PE PIPING IS GOING INTO THE BUILDING. PE (PLACTIC |
| | PIPE,TUBING AND FITTINGS) PIPING SHALL BE USED OUTSIDE |
| | UNDERGROUND ONLY. PER FBC-2004 FUEL GAS SECTIONS 403.6 |
| | PLASTIC PIPE, TUBING AND FITTINGS AND 404.14.1 |
| | LIMITATIONS. |
| | |
| | 3. PROVIDE MANUFACTURER'S SPECIFICATION SHEETS FOR THE |
| | MP REGULATORS CLEARLY INDICATING THE MAKE MODEL NUMBER, |
| | BTU LOAD CAPACITY AND A LISTING FROM A NATIONALLY |
| | RECOGNIZED TESTING LABORATORY (EXAMPLES ARE UL,CSA OR |
| | AGA). ALSO CLEARLY INDICATE THE MAKE AND MODEL NUMBER |
| | ON THE RESUBMITTED GAS ISOMETRIC. PER FBC-2004 FUEL GAS |
| | SECTION 401.1 SCOPE AND NFPA 54. |
| | |
| | 4. NOTE: ALL PLANS, SPECIFICATIONS, AND ACCOMPANYING |
| | DATA BEING FILED FOR PUBLIC RECORD SHALL CONTAIN THE |
| | PRINTED NAME OF THE RESPONSIBLE PERSON WITH THE |
| | ORIGINAL SIGNATURE AND DATE ON SUCH INFORMATION. PER |
| | SECTION *106.3.4.3. NOTE: GAS ISOMETRIC REQUIRES |
| | SIGNATURE OF THE PERSON TAKING RESPONSIBLITY. |
| | |
| | ********IMPORTANT INFORMATION******** |
| | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | END OF COMMENTS: |
| | |