Plan Review Details - Permit 08050594
Plan Review Stops For Permit 08050594
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-07-14 Cont ID  
Sent By jwitmer Date 2008-07-14 Time 12:09 Rev Time 0.77
Received By jwitmer Date 2008-07-14 Time 12:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-18 Cont ID  
Sent By jwitmer Date 2008-06-18 Time 14:51 Rev Time 1.33
Received By jwitmer Date 2008-06-18 Time 14:51 Sent To  
Notes
2008-06-18 14:51:55BUILDING PLAN REVIEW
 PERMIT: 08050594
 ADD: 2455 METROCENTRE BLVD
 CONT: OLLIMPIC POOLS
 TEL: (772)215-1680
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
  
 1A )INFORMATIONAL FL S S 713.13NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT.
 NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1B)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST
 TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO
 THE 2004 FBC BUILDING WITH THE2007 SUPPLEMENTS.
  
 2)PLEASE PROVIDE INFORMATION ON CODE COMPLIANCE WITH
 13-412.1ABC2.6.2 POOL COVERS. HEATED POOLS SHALL BE
 EQUIPPED WITH A VAPOR RETARDANT POOL COVER ON OR AT THE
 WATER SURFACE. POOLS HEATED TO MORE THAN 90 DEGREES (F)
 SHALL HAVE A POOL COVER WITH A MINIMUM INSULATION VALUE
 OF R-12.
  
 3) PLANS INDICATE A PORTABLE HANDICAPPED LIFT W/ DECK
 SLEEVE PLEASE PROVIDE MANUFACTURERS SPEC FOR THIS
 PRODUCT, 424.1.2.5.6.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-07-14 Cont ID  
Sent By btrobaug Date 2008-07-14 Time 15:30 Rev Time 0.00
Received By btrobaug Date 2008-07-14 Time 14:45 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-06-18 Cont ID  
Sent By btrobaug Date 2008-06-18 Time 16:07 Rev Time 0.00
Received By btrobaug Date 2008-06-18 Time 16:07 Sent To I
Notes
2008-06-18 16:07:16 
  
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC CHAPTER 1 AS
 AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE HEAT
 PUMPS INTENDED TO BE INSTALLED, BE SURE ELECTRICAL
 SPEC'S ARE INCLUDED.
  
 2} THE HEAT PUMP LOADS ARE NOT INCLUDED IN THE
 ELECTRICAL LOAD CALCULATIONS. INCLUDE SAME FOR FEEDER
 AND PANEL OCP SIZING. ARTICLES 220 AND 215..
  
 3} INDICATE THE PANEL DESIGNATION, OVERCURRENT
 PROTECTION AND CONDUCTOR SIZES FOR THE POOL PANEL
 FEEDERS.
  
 4} THE RECIRCULATING PUMPS LISTED IN THE LOAD
 CALCULATIONS ARE NOT ON THE ELECTRICAL DIAGRAM, 2 OF
 3.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2008-07-10 Cont ID  
Sent By mperson Date 2008-07-10 Time 08:27 Rev Time 0.00
Received By mperson Date 2008-07-10 Time 08:27 Sent To  
Notes
2008-07-10 08:28:17NOTE: POOL HEATERS ARE ELECTRIC HEAT PUMPS.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2008-06-09 Cont ID  
Sent By kstevens Date 2008-06-09 Time 08:43 Rev Time 0.00
Received By kstevens Date 2008-06-09 Time 08:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-27 Cont ID  
Sent By adarroug Date 2008-06-27 Time 09:43 Rev Time 0.00
Received By adarroug Date 2008-06-27 Time 09:43 Sent To  
Notes
2008-06-30 10:12:32TO "COMM" BD#15
2008-06-27 09:43:31WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-18 Cont ID  
Sent By btrobaug Date 2008-06-18 Time 16:07 Rev Time 0.00
Received By btrobaug Date 2008-05-21 Time 14:45 Sent To PC
Notes
2008-05-27 16:20:41TO "COMM" BD#45
2008-05-21 14:46:08WAITING FOR "COMM" BD

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-07-10 Cont ID  
Sent By mperson Date 2008-07-10 Time 08:25 Rev Time 0.00
Received By mperson Date 2008-07-10 Time 08:25 Sent To  
Notes
2008-07-10 08:26:44NOTE: PREVIOUS PLBG. COMMENTS WERE ADDRESSED.

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-06-09 Cont ID  
Sent By kstevens Date 2008-06-09 Time 08:43 Rev Time 0.00
Received By kstevens Date 2008-06-06 Time 16:57 Sent To  
Notes
2008-06-09 09:33:31DENIED
 REFERENCE: FB2004 PLUMBING
 FBC-2004 CHAPTER 1
 CITY WPB MINICIPAL CODE
  
 1. SHT 1 OF 4 INDICATES 3" WASTE LINE TO STORM SEWER.
 WASTE FROM THE FILTER SYSTEM SHALL CONNECT TO THE
 SANITARY SYSTEM. ARTICLE III SECTION 90-203.
  
 2. SHT 3 OF 4 INDICATES 2 HEAT PUMPS. SUBMIT MANUF.
 SPECIFICATION SHEETS FOR THE HEAT PUMPS. SPECIFICATION
 SHEETS SHALL SHOW LISTING FOR PRODUCT. SECTION 303.4.
  
 3. SHT 4 OF 4 LEGEND "D" INDICATES 3" WASTE LINE TO
 STORM SEWER.WASTE FROM THE FILTER SYSTEM SHALL
 CONNECT TO THE SANITARY SYSTEM. ARTICLE III SECTION
 90-203.
  
 4. SHT 4 OF 4 LEGEND "J" INDICATES OVERFLOW TO
 DISCHARGE TO GROUND.PER SECTION 1101.2 THE OVERFLOW
 FROM THE STORM WATER SHALL CONNECT TO THE STORM
 SYSTEM.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-07-08 Cont ID  
Sent By lfranco Date 2008-07-08 Time 18:14 Rev Time 0.00
Received By lfranco Date 2008-07-08 Time 18:14 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2008-06-02 Cont ID  
Sent By lfranco Date 2008-06-02 Time 17:16 Rev Time 0.00
Received By lfranco Date 2008-06-02 Time 17:16 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved