Plan Review Details - Permit 08050546
Plan Review Stops For Permit 08050546
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2008-06-16 Cont ID  
Sent By lursu Date 2008-06-16 Time 14:56 Rev Time 0.00
Received By lursu Date 2008-06-16 Time 14:56 Sent To  
Notes
2008-06-16 14:59:18BUILDING # 3 WITH THE MAIN ENTRANCE FROM WASHINGTON RD
 CAN MAINTAIN THE SAME ADDRESS AS 3703 WASHINGTON RD
 ,WEST PALM BEACH, FL 33405
  
 QUESTIONS/COMMENTS:
 LACRAMIOARA URSU, MA ,GISP
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 12 Status P Date 2009-08-05 Cont ID  
Sent By rmcdouga Date 2009-08-05 Time 10:42 Rev Time 0.00
Received By rmcdouga Date 2009-08-05 Time 10:42 Sent To  
Notes
2009-08-05 10:46:27CONTRACTOR SUBMITTED DARKER COPIES OF REVISED SHEETS
 A3, A10 AND A13.

Review Stop B BUILDING (STRUCTURAL)
Rev No 11 Status F Date 2009-07-02 Cont ID  
Sent By rmcdouga Date 2009-07-02 Time 11:28 Rev Time 0.00
Received By rmcdouga Date 2009-07-02 Time 11:28 Sent To M
Notes
2009-07-02 11:35:40REVISED SHEETS A3, A10 AND A13 ARE DENIED.
  
 THE DOOR, WINDOW, LINTEL, DETAIL AND SECTION
 IDENTIFICATION MARKS ON THE PLANS ARE TOO FAINT TO BE
 LEGIBLE. THIS APPEARS TO BE A PROBLEM WITH THE PRINTING
 OF THE COPIES. PLEASE SUBMIT LEGIBLE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status N Date 2009-05-13 Cont ID  
Sent By rmcdouga Date 2009-05-13 Time 13:17 Rev Time 0.00
Received By rmcdouga Date 2009-05-13 Time 13:17 Sent To  
Notes
2009-05-13 13:18:27SITE PLAN OK FOR BLDG/ ALSO SUBMITTED NEW LANDSCAPE
 PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status F Date 2009-04-01 Cont ID  
Sent By rmcdouga Date 2009-04-01 Time 09:39 Rev Time 0.00
Received By rmcdouga Date 2009-03-31 Time 16:41 Sent To Z
Notes
2009-04-01 09:55:062004 FBC
 REVISED PLAN SHEETS
  
 DENIED BY BUILDING
  
 1) THE REVISED PLANS THAT WERE SUBMITTED HAVE NOT BEEN
 SIGNED AND SEALED BY THE ENGINEER AS REQUIRED BY FS 471
 AND FAC 61G15-23.002.
  
 2) SHEET A3 SPECIFIES A 10' CEILING HEIGHT FOR THE
 THIRD FLOOR AND THE ELEVATIONS ON A4, A5, AND A6 SHOW
 9'-1" BEAM HEIGHTS. PLEASE CLARIFY.
  
 3) SHEET A13 SHOWS VAULTED CEILINGS AND THE TRUSS
 DRAWINGS THAT WERE SUBMITTED ARE FOR FLAT CEILINGS.
 PLEASE CORRECT.
  
 4) ON SHEET A10 THE LOCATION OF THE COLUMNS AND ROOF
 OVERHANG FOR THE EAST SIDE OF THE FRONT PORCH DOES NOT
 MATCH THE OTHER REVISED SHEETS. PLEASE CORRECT.
  
 5) THE EAST SIDE OF THE PORCH ON THE REVISED SHEETS
 APPEARS TO ENCROACH INTO THE REQUIRED 25' SETBACKS.
 THIS REQUIRES ZONING APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2009-03-11 Cont ID  
Sent By rmcdouga Date 2009-03-11 Time 08:28 Rev Time 0.00
Received By rmcdouga Date 2009-03-11 Time 08:28 Sent To  
Notes
2009-03-11 08:28:56TRUSS DRAWINGS REVIEWED

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2009-02-09 Cont ID  
Sent By rmcdouga Date 2009-02-09 Time 14:41 Rev Time 0.00
Received By rmcdouga Date 2009-02-09 Time 14:41 Sent To  
Notes
2009-02-09 14:49:52TRUSS LAYOUT AND DRAWINGS SUBMITTAL
  
 DENIED BY BUILDING
  
 1) THE SECOND FLOOR TRUSS LAYOUT DOES NOT MATCH THE
 APPROVED PLANS. THE LOWER ROOF ON THE EAST ELEVATION IS
 SHOWN THE LENGTH OF THE STRUCTURE ON THE TRUSS LAYOUT
 AND THE APPROVED PLANS HAVE IT SLIGHTLY LONGER THAN THE
 GARAGE DOOR OPENING. PLEASE CORRECT.
  
 2) THE UPPER ROOF TRUSS DRAWINGS HAVE A BOTTOM CORD
 LIVE LOAD OF 0 PSF AND THE TRUSS LAYOUT SPECIFIES A
 BOTTOM CORD LIVE LOAD OF 10 PSF. FBC R305.1 REQUIRES A
 LIVE LOAD OF 10 PSF FOR ATTICS WITHOUT STORAGE. PLEASE
 CORRECT.
  
 3) THE MEAN HEIGHT OF THE STRUCTURE IS SPECIFIED AS 15
 FT ON THE UPPER ROOF TRUSS DRAWING FOR TRUSS UJ3 AND
 THE THREE STORY STRUCTURE SHOWN ON THE PLANS HAS A MEAN
 ROOF HEIGHT OF 35 FT. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2009-01-13 Cont ID  
Sent By rmcdouga Date 2009-01-13 Time 11:59 Rev Time 0.00
Received By rmcdouga Date 2009-01-13 Time 11:59 Sent To  
Notes
2009-01-13 10:50:15TRUSS LAYOUT AND DRAWINGS SUBMITTAL
  
 DENIED BY BUILDING
  
 1) TRUSS LAYOUT IS REQUIRED TO BE REVIEWED AND APPROVED
 IN WRITING BY THE DESIGNER OF RECORD FOR THE STRUCTURE.
  
 2) THE SECOND FLOOR TRUSS LAYOUT DOES NOT MATCH THE
 APPROVED PLANS. THE LOWER ROOF ON THE EAST ELEVATION IS
 SHOWN THE LENGTH OF THE STRUCTURE ON THE TRUSS LAYOUT
 AND THE APPROVED PLANS HAVE IT SLIGHTLY LONGER THAN THE
 GARAGE DOOR OPENING. PLEASE REVISE.
  
 3) THE FG2 FLOOR GIRDER IS SHOWN ON THE THIRD FLOOR
 TRUSS LAYOUT EXTENDING FROM EXTERIOR WALL TO EXTERIOR
 WALL. THE THIRD FLOOR FRAMING ON THE APPROVED PLANS
 SHOW THIS GIRDER STOPPING AT THE BEARING WALL OF THE
 STAIR OPENING. PLEASE COORDINATE DRAWINGS.
  
 4) THE ROOF TRUSS DRAWINGS HAVE A BOTTOM CORD LIVE LOAD
 OF 0 PSF AND THE TRUSS LAYOUT SPECIFIES A BOTTOM CORD
 LIVE LOAD OF 10 PSF. FBC R305.1 REQUIRES A LIVE LOAD OF
 10 PSF FOR ATTICS WITHOUT STORAGE. PLEASE CORRECT.
  
 5) THE MEAN HEIGHT OF THE STRUCTURE IS SPECIFIED AS 15
 FT ON THE TRUSS DRAWINGS AND THE THREE STORY STRUCTURE
 SHOWN ON THE PLANS HAS A MEAN ROOF HEIGHT OF 35 FT.
 PLEASE CORRECT.
  
 6) THE TRUSS DRAWINGS SPECIFY AN UPLIFT OF 667# FOR THE
 UG1 GIRDER TRUSS AND THE U3 COMMON TRUSS HAS AN UPLIFT
 OF 1114#. PLEASE CHECK THESE CALCULATIONS AND EXPLAIN
 HOW THIS IS POSSIBLE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2008-11-26 Cont ID  
Sent By rmcdouga Date 2008-11-26 Time 13:53 Rev Time 0.00
Received By rmcdouga Date 2008-11-26 Time 13:53 Sent To E
Notes
2008-11-26 13:17:202004 FBC W/2007 REVISIONS
 NSFD
  
 REVISED PLAN SHEETS A1, A2 AND A3 ARE DENIED.
  
 1) THE PLANS ARE MISSING INFORMATION. PORTIONS OF THE
 SCHEDULES AND TABLES ARE MISSING FROM THESE PAGES.
  
 2) THE NEW DOUBLE FRENCH DOOR (1A) SHOWN ON SHEET 1A IS
 NOT LISTED IN THE DOOR SCHEDULE. PLEASE REVISE.
 R301.2.1
  
 3) THE DOOR FOR THE GARAGE TO THE RESIDENCE IS REQUIRED
 TO COMPLY WITH R309.1 OPENING PROTECTION. OPENINGS FROM
 A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING
 PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN
 THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID
 WOOD DOORS NOT LESS THAN 13/8 INCHES (35 MM) IN
 THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS
 THAN 13/8 INCHES (35 MM) THICK, OR 20-MINUTE FIRE-RATED
 DOORS.
  
 4) A SECOND FLOOR WINDOW AND FIRST FLOOR DOORS HAVE
 BEEN MOVED OR CHANGED. REVISED ELEVATIONS REFLECTING
 THE CHANGES ARE REQUIRED. FBC 106.1.1* CITY AMENDMENTS
  
 5) A WASHER AND DRYER HAS BEEN ADDED TO THE FIRST FLOOR
 AND HAS NOT BEEN CLOUDED TO INDICATE THE REVISION. FBC
 106.1.3* CITY AMENDMENTS.
  
 6) ON SHEET A3, IT APPEARS THAT THE SHOWER HAS BEEN
 ELIMINATED FROM BATH ROOM #2. PLEASE CLARIFY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-09-26 Cont ID  
Sent By rmcdouga Date 2008-09-26 Time 15:36 Rev Time 0.00
Received By rmcdouga Date 2008-09-26 Time 15:36 Sent To  
Notes
2008-09-26 15:37:05STAMP PLANS AND PRINT PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-09-23 Cont ID  
Sent By rmcdouga Date 2008-09-23 Time 10:31 Rev Time 0.00
Received By rmcdouga Date 2008-09-23 Time 10:31 Sent To  
Notes
2008-09-23 10:33:24NEW PRODUCT APPROVALS WITH ADEQUATE DESIGN PRESSURES
 FOR THE GARAGE DOOR WERE SUBMITTED. THIS SATISFACTORILY
 ADDRESSES THE SECOND PROVISO ITEM.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-09-04 Cont ID  
Sent By rmcdouga Date 2008-09-04 Time 13:28 Rev Time 0.00
Received By rmcdouga Date 2008-09-04 Time 13:28 Sent To Z
Notes
2008-09-04 13:28:45PLAN REVIEW STATUS WILL BE CHANGED TO P WHEN IMPACT
 FEES ARE PAID AND STAMPED PLANS AND PAID RECEIPT ARE
 SUBMITTED.
  
 BUILDING PROVISO
  
 PROVIDE CARBON MONOXIDE ALARMS. PER FS 553.885 CARBON
 MONOXIDE ALARM REQUIRED.-- EVERY BUILDING FOR WHICH A
 BUILDING PERMIT IS ISSUED FOR NEW CONSTRUCTION ON OR
 AFTER JULY 1, 2008, AND HAVING A FOSSIL-FUEL-BURNING
 HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE
 SHALL HAVE AN APPROVED OPERATIONAL CARBON MONOXIDE
 ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR
 SLEEPING PURPOSES. PLEASE COMPLY.
  
 SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR 16' X 7'
 GARAGE DOOR WITH ADEQUATE DESIGN PRESSURES. ( + 43.0,
 -52.2 ).

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-16 Cont ID  
Sent By rmcdouga Date 2008-06-16 Time 07:38 Rev Time 0.00
Received By rmcdouga Date 2008-06-16 Time 07:38 Sent To  
Notes
2008-06-13 16:57:462004 FBC W/2007 REVISIONS
 NEW SINGLE FAMILY RESIDENCE
  
 DENIED BY BUILDING
 NOTE: THE PLANS HAVE BEEN REVIEWED AS A SINGLE FAMILY
 R3 OCCUPANCY USING THE 2004 FBC RESIDENTIAL CODE. IF
 THE BUILDINGS ARE TO BE CONDOMINIUMS OR ANYTHING OTHER
 THAN ONE OR TWO FAMILY RESIDENCES ADDITIONAL
 REQUIREMENTS WILL RESULT.
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE LOT IS LOCATED IN AN A5 FLOOD ZONE WITH A
 REQUIRED ELEVATION 7.5' WHICH INCLUDES THE ADDITIONAL
 6" REQUIRED BY CITY ORDINANCE, AN ELEVATION CERTIFICATE
 WILL BE REQUIRED.
  
 4) THE SURVEY AND DRAINAGE PLANS SPECIFY TWO STORY
 STRUCTURES AND THE ARCHITECTURAL PLANS SPECIFY THREE
 STORY STRUCTURES. PLEASE CORRECT.
  
 5) THE NORTH SIDE OF THE STRUCTURE IS 5.5' FROM THE
 PROPERTY LINE. SPECIFY THE DISTANCE TO ANY STRUCTURES
 LOCATED ON THE ADJACENT LOT. R302.1 EXTERIOR WALLS.
 EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM)
 SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE
 RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL
 NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM
 AN ADJACENT PROJECTION OR WALL.
  
 6)TWO COPIES OF ALL SUBMITTALS ARE REQUIRED PER FBC
 106.1* CITY AMENDMENTS. ONLY ONE COPY OF THE SURVEY WAS
 SUBMITTED. TWO COPIES OF ALL SUBMITTALS ARE REQUIRED.
  
 7) PLEASE IDENTIFY THE STRUCTURES ON THE SITE PLANS BY
 THE UNIT NUMBERS AS SPECIFIED IN THE PLANS. FBC
 106.1.1* CITY AMENDMENTS
  
 8)FBC R401.4AREA OF QUESTIONABLE
 SOIL.SUBMIT TWO COPIES OF A SIGNED AND SEALED
 GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 9) THE ENERGY CALC. FORM LISTS THE EXTERIOR INSULATION
 AS R-5 AND THE PLAN SPECIFY R-4.2. PLEASE CORRECT. THE
 FORM IS ALSO REQUIRED TO BE SIGNED AND DATED BY THE
 PREPARER AND THE OWNER/AGENT. FBC 13-600.
  
 10) ON SHEET SP-1 REVISE IMPACT PROTECTION NOTE TO 2004
 FBC R301.2.1.2 AND CODE REFERENCE TO 2004 FBC W/2007
 REVISIONS.
  
 11) THE INDIVIDUAL UNITS WILL BE REQUIRED TO HAVE
 SEPARATE ADDRESSES. PLEASE CONTACT LILI URSU AT
 561-822-1239.
  
 12) THE BATHROOM WINDOWS SHALL COMPLY WITH R308.1 AND
 R301.4 FOR GLAZING IN HAZARDOUS LOCATIONS.
  
 13) ON SHEET A3 DOOR #18 ( 16' GARAGE DOOR) IS
 SPECIFIED FOR THE SHOWER DOOR AT BATHROOM #2. PLEASE
 CORRECT.
  
 14)ON SHEET A8 THE REQUIRED SOIL COMPACTION IS
 SPECIFIED AS 25,000 PSF. PLEASE CORRECT.
  
 15) WALL SECTION 1 ON A14 SPECIFIES THE FOOTING AS A
 MINIMUM 18"BELOW GRADE TO THE BOTTOM AN A MINIMUM OF
 6" ABOVE GRADE, WHICH REQUIRES A 24" DEEP FOOTER. F1 ON
 A8 IS FOR AN 18" DEEP FOOTER. FBC R403.1.4 REQUIRES A
 MINIMUM OF 12" BELOW GRADE AND R404.1.6 REQUIRES A
 MINIMUM OF 4" ABOVE GRADE FOR MASONRY. PLEASE CORRECT.
  
 16) SPECIFY THE ATTACHMENT OF THE 2X12 BEAM AT THE
 COVERED PORCH TO THE MASONRY STRUCTURE. FBC 106.1.1*
 CITY AMENDMENTS
  
 17) PROVIDE A DETAIL OF THE COVERED PORCH SHOWING THE
 ATTACHMENT OF THE LEDGER AND TRUSSES TO THE MASONRY
 STRUCTURE.
  
 18) ON SHEET A15 THE WRONG CODE AND SECTION IS
 SPECIFIED FOR THE EMERGENCY EGRESS WINDOWS. PLEASE
 REVISE TO 2004 FBC SECTION R310.
  
 19) DETAIL 7 ON A15 AND SECTION 1 ON A14 SHOULD SPECIFY
 RING SHANK NAILS FOR ROOF SHEATHING FASTENING AS
 REQUIRED BY R803.2.3.1 OF THE 2006 REVISIONS TO THE
 2004 FBC RESIDENTIAL CODE.
  
 20) ON SHEET A15 THE SECOND ROW OF THE SHEATHING NAIL
 SCHEDULE LISTS ROOF AND SPECIFIES 8D PLANE SHANK NAILS
 AND TYP. NON-SHEARWALL. IS THIS MEANT TO BE THE
 FASTENING FOR WALL SHEATHING?PLEASE CORRECT. SEE
 PREVIOUS COMMENT.
  
 21) SPECIFY THE DESIGN WINDLOAD PRESSURES FOR THE DOOR
 AND WINDOW OPENINGS ON THE PLANS. SEE TABLES R301.2(2)
 AND R301.2(4).
  
 22) ON SHEET SP-1 THE DOOR FROM THE GARAGE TO THE
 LIVING SPACE IS SPECIFIED AS A "B" LABEL DOOR, THIS
 DESIGNATION IS NO LONGER USED. R309.1 REQUIRES A 20
 MINUTE FIRE RATED DOOR. PLEASE REVISE.
  
 23) SUBMIT (2) COPIES OF SPECIFICATIONS FOR THE ICYNENE
 INSULATION. FBC 106.1.2* CITY AMENDMENTS
  
 24) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE
 OVERHEAD GARAGE DOOR HAS A MAXIMUM WIDTH OF 9'. SUBMIT
 PRODUCT APPROVALS FOR A 16' WIDE DOOR. RULE 9B-72
  
 25) IN ADDITION TO THE FLORIDA COVERSHEET, PLEASE
 SUBMIT THE NOA/EVALUATION REPORT FOR THE MONIER ROOF
 TILE. SPECIFY WHICH ATTACHMENT METHOD WILL BE USED BY
 CIRCLING THE APPLICABLE ONE ON THE PRODUCT APPROVAL.
 RULE 9B-72
  
 26) THE ONLY PRODUCT APPROVAL THAT WAS SUBMITTED FOR
 EXTERIOR DOORS IS FOR GLAZED FRENCH DOORS. IS THIS THE
 TYPE OF SWING DOOR THAT WILL BE INSTALLED AT THE
 GARAGE? IF NOT PLEASE SUBMIT THE APPROPRIATE PRODUCT
 APPROVALS. NOTE: DESIGNER OF RECORD APPROVAL IS
 REQUIRED.
  
 IN ORDER TO EXPEDITE PLAN REVIEW, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW THE COMMENTS WERE
 ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2009-03-03 Cont ID  
Sent By btrobaug Date 2009-03-03 Time 15:43 Rev Time 0.00
Received By btrobaug Date 2009-03-03 Time 15:09 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2008-11-26 Cont ID  
Sent By btrobaug Date 2008-11-26 Time 16:37 Rev Time 0.00
Received By btrobaug Date 2008-11-26 Time 16:11 Sent To P
Notes
2008-11-26 16:37:53 
  
  
 REVISION DENIED
  
 1} SUBMIT PLANS FOR ELECTRICAL REVISIONS AFFECTED BY
 THIS REVISION.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-08-29 Cont ID  
Sent By btrobaug Date 2008-08-29 Time 12:09 Rev Time 0.00
Received By btrobaug Date 2008-08-29 Time 10:47 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-05-23 Cont ID  
Sent By btrobaug Date 2008-05-23 Time 13:43 Rev Time 0.00
Received By btrobaug Date 2008-05-23 Time 11:15 Sent To M
Notes
2008-05-23 13:42:51 
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER
 1AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
  
 1} THE EQUIPMENT GROUND BETWEEN THE METER AND
 DISCONNECT ON THE RISER DIAGRAM CREATES A PARALLEL PATH
 TO GROUND WITH THE NEUTRAL AND MUST BE REMOVED. AN
 ISOLATED NEUTRAL AND EQUIPMENT GROUND ARE TO BE RAN
 FROM THE FIRST MEANS OF DISCONNECT. 250.6.
  
 2} THERE IS ONLY ONE A/C SYSTEM ON THE PANEL SCHEDULE ,
 SHEET E1. SHEET M1 HAS SPECIFICATIONS FOR TWO UNITS,
 NEITHER OF WHICH DOES THE WATTAGES FOR THE HEAT STRIP
 CORRELATE. RECALCULATE THE LOAD AND CHANGE THE PANEL
 SCHEDULE TO INDICATE THE INTENDED INSTALLATION.
  
 3} CIRCUIT #10 HAS NO OCP LISTED.
  
 4} THERE IS POOL EQUIPMENT LISTED ON THE PANEL
 SCHEDULE. IS THIS A GENERIC SCHEDULE INTENDED FOR ALL
 THREE UNITS OR A SCHEDULE FOR UNIT #3 THAT IS THE
 PROJECT ON THE APPLICATION DESCRIPTION? SEE 210.25 FOR
 BRANCH CIRCUIT RESTRICTIONS APPLYING TO COMMON AREAS.
  
 5} CIRCUIT 2,4 HAS AN OCP OF 40 AMPS FOR THE 8000 WATT
 WATER HEATER. SEE ARTICLE 422.13 CONTINUOUS LOAD.
 (8000/240= 33.33 X 125%= 41.6AMPS).
  
 6} SHEET E2 NEEDS TWO RECEPTACLES TO COMPLY WITH
 210.52(C)(1).
  
 7} THE MASTER BEDROOM AND BEDROOM #2 ON SHEET E3 NEED
 ADDED RECEPTACLES TO COMPLY WITH 210.52(A)(1) & (2).
 SEE REVIEWED SET FOR APPROXIMATE LOCATION.
  
 8} A RECEPTACLE PER 210.63, LIGHT PER 210.70(A) (3) ARE
 REQUIRED IN THE ATTIC WHERE THE AHU IS TO BE INSTALLED,
 (SHOWN ON SHEET M3).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2008-09-23 Cont ID  
Sent By rchokshi Date 2008-09-23 Time 15:46 Rev Time 0.00
Received By rchokshi Date 2008-09-23 Time 15:44 Sent To  
Notes
2008-09-23 15:46:20ENGINEERING REVIEW NOT REQUIRED PER ROBERT BROWN.
 THEREFORE, I PUT "N" IN REVIEW COMMENT.
  
 RASIK CHOKSHI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2008-09-17 Cont ID  
Sent By rchokshi Date 2008-09-17 Time 13:27 Rev Time 0.00
Received By rchokshi Date 2008-09-17 Time 13:15 Sent To  
Notes
2008-09-17 13:27:06FAILED FOR FOLLOWING REASONS:
  
 1. PLEASE SHOW ON DRAWINGS THE TURBIDITY BARRIER
 DETAILS OF POLLUTION PREVENTION . PLEASE SHOW ON
 DRAWINGS THE TURBIDITY BARRIER AROUND CATCH BASINS, ANY
 OUT FALLS OR LAKES ETC DURING CONSTRUCTION AND ALL
 DEMOLITION PHASE. HEIGHT OF BARRIER SHOULD BE HIGH
 ENOUGH PER FDEP TO STOP DUST PARTICLES.
  
 2. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO.
 4060-07:
  
 ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH
 EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY
 APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE
 FOLLOWING:
  
 1. EROSION CONTROL, AND
 2. LAND STABILIZATION
  
 THE AMOUNT OF THE EROSION CONTROL AND LAND
 STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER
 OF RECORD USING THE CURRENT CITY COST SCHEDULE AND
 VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT.
 PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION
 SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION.
  
 UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN
 FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL
 TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE
 MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS.
  
 A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM
 THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR.
  
 3. PLEASE SHOW ON DRAWINGS DUMPSTER & ITS ENCLOSURE
 DETAILS PER CITY OF WPB, & LOCATION ON DWG, LOCATION
 MUST BE ACCESSIBLE FOR PICKUP TRUCK.
  
 4. PLEASE SHOW ON STORM WATER QUALITY CALCULATION THAT
 YOU HAVE CONSIDERED FLOOD ZONE AREA, & 5,10, 25, 50,
 100 YEAR FLOOD CRITERIA AND CROWN OF THE ROAD WHEN YOU
 DETERMINE THE FIRST FLOOR ELEVATION. FIRST FLOOR
 ELEVATION SHOULD BE ATLEAST 1 FOOT HIGHER THAN HIGHEST
 CROWN OF THE ROAD.
  
 5. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE
 SO, WE CAN SEE THE LAYOUT OF STORM WATER PIPES FROM ALL
 OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE
 CONTROL STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING
 ELEVATION, ETC ON DRAWINGS, CALCULATION FOR
 EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET
 DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL
 THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL
 ENVRONMENTAL REPORT.
  
 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST, AROUND
 YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET
 FLOODED AND HAVE ENOUGH DRAINS.
  
 7. PLEASE PROVIDE A COPY OF GEO-TECH REPORT & STORM
 WATER QUALITY CALCULATIONS TO 1000 45TH STREET FOR
 THEIR APPROVAL BEFORE WE ISSUE A PERMIT.
  
 8. WATER & SEWER PLANS MUST BE APPROVED FROM MANNY G.
 OF 1000 45TH STREET BEFORE WE ISSUE A PERMIT.
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI 805-6723
  
  
  
  
  
  

Review Stop ENG-F ENGINEERING FINAL DRAWING REV
Rev No 1 Status N Date 2009-09-17 Cont ID  
Sent By efabian Date 2009-09-17 Time 12:23 Rev Time 0.50
Received By efabian Date 2009-09-17 Time 12:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2009-11-12 Cont ID  
Sent By shill Date 2009-11-12 Time 15:47 Rev Time 0.00
Received By shill Date 2009-11-12 Time 15:47 Sent To  
Notes
2009-11-12 15:47:52TO ZONING
  

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2009-10-19 Cont ID  
Sent By dpalmer Date 2009-10-19 Time 14:08 Rev Time 0.00
Received By dpalmer Date 2009-10-19 Time 14:08 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2009-09-01 Cont ID  
Sent By kstevens Date 2009-09-01 Time 13:33 Rev Time 0.00
Received By kstevens Date 2009-09-01 Time 13:33 Sent To  
Notes
2009-09-01 13:35:45SENT TO LANDSCAPE ( ZONING).

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2009-07-01 Cont ID  
Sent By kstevens Date 2009-07-01 Time 09:39 Rev Time 0.00
Received By kstevens Date 2009-07-01 Time 09:39 Sent To  
Notes
2009-07-01 09:41:16TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2009-06-08 Cont ID  
Sent By mcruz Date 2009-06-08 Time 15:49 Rev Time 0.00
Received By mcruz Date 2009-06-03 Time 14:51 Sent To  
Notes
2009-06-04 14:50:53LANDSCAPE REVISION TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2009-05-06 Cont ID  
Sent By shill Date 2009-05-06 Time 11:01 Rev Time 0.00
Received By shill Date 2009-05-06 Time 11:01 Sent To  
Notes
2009-05-06 11:01:29TO RESIDENTIAL BOARD #1
  

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2009-03-05 Cont ID  
Sent By adarroug Date 2009-03-05 Time 09:11 Rev Time 0.00
Received By adarroug Date 2009-03-05 Time 09:11 Sent To B
Notes
2009-03-05 09:11:46TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2009-02-20 Cont ID  
Sent By adarroug Date 2009-02-20 Time 10:21 Rev Time 0.00
Received By adarroug Date 2009-02-20 Time 10:21 Sent To E
Notes
2009-02-20 10:22:01TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2009-02-06 Cont ID  
Sent By adarroug Date 2009-02-06 Time 16:42 Rev Time 0.00
Received By adarroug Date 2009-02-06 Time 16:42 Sent To B
Notes
2009-02-06 16:42:43TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2009-01-30 Cont ID  
Sent By adarroug Date 2009-01-30 Time 10:59 Rev Time 0.00
Received By adarroug Date 2009-01-30 Time 10:59 Sent To Z
Notes
2009-01-30 10:59:24TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-01-06 Cont ID  
Sent By adarroug Date 2009-01-06 Time 13:27 Rev Time 0.00
Received By adarroug Date 2009-01-06 Time 13:27 Sent To B
Notes
2009-01-06 13:28:14TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-10-27 Cont ID  
Sent By shill Date 2008-10-27 Time 13:57 Rev Time 0.00
Received By shill Date 2008-10-27 Time 13:57 Sent To M
Notes
2008-10-27 13:58:05TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-09-25 Cont ID  
Sent By adarroug Date 2008-09-25 Time 09:32 Rev Time 0.00
Received By adarroug Date 2008-09-25 Time 09:32 Sent To Z
Notes
2008-09-25 09:32:21TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-09-12 Cont ID  
Sent By adarroug Date 2008-09-12 Time 09:33 Rev Time 0.00
Received By adarroug Date 2008-09-12 Time 09:33 Sent To Z
Notes
2008-09-12 09:33:38TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-08-13 Cont ID  
Sent By adarroug Date 2008-08-13 Time 11:44 Rev Time 0.00
Received By adarroug Date 2008-08-13 Time 11:44 Sent To Z
Notes
2008-08-13 11:44:37TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-16 Cont ID  
Sent By rmcdouga Date 2008-06-16 Time 07:38 Rev Time 0.00
Received By rmcdouga Date 2008-05-20 Time 16:42 Sent To  
Notes
2008-05-20 16:43:39TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 7 Status P Date 2009-10-21 Cont ID  
Sent By rkussner Date 2009-10-21 Time 15:01 Rev Time 0.00
Received By rkussner Date 2009-10-21 Time 15:01 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 6 Status F Date 2009-09-08 Cont ID  
Sent By rkussner Date 2009-09-08 Time 16:09 Rev Time 0.00
Received By rkussner Date 2009-09-08 Time 16:09 Sent To Z
Notes
2009-09-08 16:55:20***LANDSCAPE REVIEW FAILED***
  
 1. ENGINEERING MUST APPROVE CHANGES TO DRIVEWAY AND
 OTHER HARDSCAPE PRIOR TO LANDSCAPE APPROVAL.
  
 2. THERE ARE DIFFERENCES BETWEEN THE SITE AND LANDSCAPE
 PLANS REGARDING THE HARDSCAPE. THE WALKWAYS ON THREE
 SIDES OF BUILDING, AS WELL AS THE AIR CONDITIONING AND
 OTHER CONCRETE PADS ALONG THE WEST SIDE OF THE HOME ARE
 NOT THE SAME ON BOTH PLANS. ALL PLANS SHALL BE
 CONSISTENT.
  
 3. PURSUANT TO SECTION 94-482 (A), REQUIRED PARKING MAY
 BE LOCATED IN A FRONT YARD; HOWEVER, THE LESSER OF 1000
 SQUARE FEET OR 75 PERCENT OF THE FRONT YARD AREA MUST
 BE LANDSCAPED. PLEASE PROVIDE DATA THAT DEMONSTRATES
 COMPLIANCE WITH THIS SECTION.
  
 4. PURSUANT TO SECTION 18-209 (L), EVERY OWNER OF A
 VACANT BUILDING, STRUCTURE OR LOT, SHALL PROVIDE AND
 MAINTAIN ALL UNPAVED AREAS OF THE SITE WITH GRASS,
 GROUND COVER, SHRUBBERY OR OTHER SUITABLE PLANT
 MATERIAL. THIS APPLIES TO THE BALANCE OF THE
 UNDEVELOPED SITE.
  
 5. THE PERIMETER LANDSCAPING FOR THE ENTIRE SITE SHALL
 BE INSTALLED AND INSPECTED WITH UNIT #3. THIS WAS
 AGREED UPON DURING THE INITIAL REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  

Review Stop L LANDSCAPING
Rev No 5 Status P Date 2009-06-05 Cont ID  
Sent By rkussner Date 2009-06-05 Time 13:30 Rev Time 0.00
Received By rkussner Date 2009-06-05 Time 13:30 Sent To  
Notes
2009-06-05 13:36:37***LANDSCAPE REVIEW PASSES WITH PROVISO***
  
 INSTALL HEDGE ALONG WASHINGTON ROAD 5 FEET IN FROM
 PROPERTY LINE AND PLANT GROUND COVER OR SOD BETWEEN
 HEDGE AND SIDEWALK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 4 Status F Date 2009-05-19 Cont ID  
Sent By rkussner Date 2009-05-19 Time 17:23 Rev Time 0.00
Received By rkussner Date 2009-05-19 Time 17:23 Sent To  
Notes
2009-05-19 17:40:50***LANDSCAPE REVIEW FAILED***
  
 1. FIVE POINTS WERE TAKEN FOR UTILIZATION OF
 MOISTURE-SENSING CONTROLLER OTHER THAN RAIN SWITCH. IF
 THIS OPTION IS TAKEN, THE TYPE OF EQUIPMENT TO BE USED
 SHALL BE IDENTIFIED.
  
 2. NO MORE THAN A ONE INCH LAYER OF MULCH SHALL BE
 APPLIED OVER THE ROOT BALL OF ANY TREE OR SHRUB. THE
 REQUIRED THREE INCH LAYER IS PLACED OUTSIDE OF THE
 ROOTBALL. THE TRUNK FLAIR AND/OR THE FIRST HORIZONTAL
 ROOT SHALL ALWAYS BE VISIBLE FOR EACH PLANTED TREE. THE
 TREES AND SHRUBS SHALL BE PLANTED AT OR SLIGHTLY ABOVE
 GRADE.
  
 3. ALL BRAZILIAN PEPPER AND OTHER INVASIVE TREES SHALL
 BE REMOVED FROM THE DEVELOPMENT SITE. IF THEY ARE
 GROWING OUTSIDE OF THE PROPERTY, ALL BRANCHES SHALL BE
 CUT BACK TO THE PROPERTY LINE.
  
 4. THE GROUND LEVEL AIR CONDITIONING UNITS AND POOL
 EQUIPMENT SHALL BE SCREENED ON THREE SIDES. SHOW THE
 LOCATION OF THE GARBAGE CONTAINERS AND THE MANNER IN
 WHICH THEY WILL BE SCREENED.
  
 5. PURSJUANT TO SECTION 94-442 (C), PALM TREES MAY BE
 SUBSTITUTED FOR NOT MORE THAN 35 PERCENT OF THE SHADE
 OR FLOWERING TREES REQUIRED BY THIS ARTILCE. OF THE
 PROPOSED PALMS, ONLY ROYAL PALMS MAY BE SUBSTITUTED ON
 A ONE FOR ONE BASIS FOR SHADE TREES. ALL OTHER PALMS
 ARE REQUIRED TO BE 2:1.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 3 Status F Date 2009-02-12 Cont ID  
Sent By rkussner Date 2009-02-12 Time 14:30 Rev Time 0.00
Received By rkussner Date 2009-02-12 Time 13:12 Sent To  
Notes
2009-02-12 14:53:32***LANDSCAPE REVIEW FAILED***
  
 1. REPEAT COMMENT---LANDSCAPE PLANS SHALL BE SIGNED AND
 SEALED BY A REGISTERED LANDSCAPE ARCHITECT.
  
 2. REPEAT COMMENT---PROVIDE ALL REQUIRED LANDSCAPE
 CALCULATIONS FOR MULTIFAMILY DEVELOPMENT BASED UPON
 ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 3. REPEAT COMMENT---SHOW ALL UTIITIES, EASEMENTS,
 TRASH/GARBAGE AREAS WITH SCREENING, ANY PROPOSED
 MECHANICAL EQUIPMENT WITH SCREENING, CANOPY SPREAD OF
 TREES ON NEIGHBORING PROPERTY THAT MAY IMPEDE THE
 GROWTH OF THE PROPOSED TREES, AND ANYTHING ELSE THAT
 MAY IMPACT THE PROPOSED LANDSCAPING.
  
 4. REPEAT COMMENT---PROVIDE SOD AND IRRIGATION IN THE
 RIGHTS-OF-WAY.
  
 5 PURSUANT TO SECTION 94-443 (D) (1) (A), THE BUFFER
 STRIP SHALL NOT BE INTERUPTED AT MORE THAN 20 PERCENT
 OF IT REQUIRED LENGTH TO PROVIDE VEHICULAR INGRESS AND
 EGRESS. THOUGH TWO CONCRETE RIBBONS SEPARATED BY A 3
 FOOT SOD AREA WAS USED FOR ACCESS ACROSS THE PROPERTY
 LINE, THE VEHICULAR ACCESS IS 9 FEET EACH ALONG LYTTON
 COURT AND ONLY 13 FEET IS PERMITTED.
  
 6. OTHER LANDSCAPE COMMENTS WILL BE FORTHCOMING ONCE A
 SIGNED AND SEALED LANDSCAPE PLAN WITH ALL REQUIRED
 CALCULATIONS HAS BEEN SUBMITTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  
  

Review Stop L LANDSCAPING
Rev No 2 Status N Date 2008-09-24 Cont ID  
Sent By rkussner Date 2008-09-24 Time 14:21 Rev Time 0.00
Received By rkussner Date 2008-09-24 Time 14:20 Sent To  
Notes
2008-09-24 14:34:04MR. NICK RAICH CAME INTO THE PLANNING AND ZONING
 DEPARTMENT ON SEPTERMBER 24, 2008 WITH A NOTORIZED
 LETTER CONCERNING PERMIT #08 050546. THE LETTER DATED
 SEPTEMBER 24TH CONFIRMS THAT MR RAICH WILL SUBMIT A
 LANDSCAPE PLAN FOR A SINGLE FAMILY HOME OR MULTI-FAMILY
 DEVELOPMENT, DEPENDING UPON WHICH WILL APPLY. HE AGREED
 THAT THE PLAN WILL BE SUBMITTED, REVIEWED AND APPROVED
 PRIOR TO CALLING IN FOR C/O INSPECTION FOR THIS PERMIT.
 THE PERMIT FOR CONSTRUCTION OF THE FIRST HOME CAN GO
 FORWARD AT THIS TIME.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2008-09-22 Cont ID  
Sent By rkussner Date 2008-09-22 Time 13:39 Rev Time 0.00
Received By rkussner Date 2008-09-22 Time 13:39 Sent To  
Notes
2008-09-22 13:51:19***LANDSCAPE REVIEW FAILED***
  
 1. LANDSCAPE PLANS MUST BE SIGNED AND SEALED BY A
 REGISTERED LANDSCAPE ARCHITECT.
  
 2. PROVIDE ALL REQUIRED LANDSCAPE CALCULATIONS FOR
 MULITFAMILY DEVELPMENT BASED UPON ARTICLE XIV OF THE
 ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 3. THE PLANT LIST SHALL SHOW THE SIZE AND SPACING FOR
 ALL TREES, SHRUBS AND GROUND COVER.
  
 4. THE ENTIRE PERIMETER LANDSCAPE BUFFER SHALL BE
 INSTALLED WITH PHASE I. THE BALANCE OF THE SITE SHALL
 BE SODDED AND IRRIGATED UPON COMPLETION OF THE FIRST
 PHASE.
  
 5. PROVIDE SOD AND IRRIGATION IN THE RIGHTS-OF-WAY.
  
 6. IDENTIFY THE STREETS AND RIGHT-OF-WAY AREAS ON THE
 LANDSCAPE PLAN.
  
 7. SHOW ALL UTILITIES, EASEMENTS, TRASH/GARBAGE AREAS
 WITH SCREENING, GROUND LEVEL AIR CONDITIONING UNITS AND
 OTHER MECHANICAL EQUIPMENT WITH SCREENING, CANOPY
 SPREAD OF TREES ON NEIGHBORING PROPERTY THAT MAY IMPEDE
 THE GROWTH OF THE PROPOSED TREES, AND ANYTHING ELSE
 THAT MAY IMPACT THE PROPOSED LANDSCAPING.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2009-08-05 Cont ID  
Sent By rmcdouga Date 2009-08-05 Time 10:47 Rev Time 0.00
Received By rmcdouga Date 2009-08-05 Time 10:47 Sent To  
Notes
2009-08-05 10:54:32CONTRACTOR SUBMITED DARKER COPIES OF REVISED PLANS M1,
 M2 AND M3.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2009-07-02 Cont ID  
Sent By hmoser Date 2009-07-02 Time 15:19 Rev Time 0.00
Received By hmoser Date 2009-07-02 Time 15:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2009-03-30 Cont ID  
Sent By hmoser Date 2009-03-30 Time 10:43 Rev Time 0.00
Received By hmoser Date 2009-03-30 Time 10:08 Sent To B
Notes
2009-03-30 10:53:37PLAN DENIED
 PLEASE PROVIDE DUCT SIZE FOR FLEX DUCT ON PAGE M-1
 ELEVATOR ROOM , PAGE M-2 SUPPLY DUCT 10X14 DUCT SIZE TO
 10X10 DOWN , PAGE M-3 RETURN AIR .
 PLANS MUST BE SEALED BY GORDON BUCK .
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2008-10-29 Cont ID  
Sent By kstevens Date 2008-10-29 Time 14:55 Rev Time 0.25
Received By hmoser Date 2008-10-29 Time 15:32 Sent To P
Notes
2008-10-29 15:34:11REVISION TO PLANS A1, A2, A3, AND M4 (PLUMBING) NO
 MECHANICAL REVISIONS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-09-02 Cont ID  
Sent By tgordon Date 2008-09-02 Time 08:41 Rev Time 0.45
Received By tgordon Date 2008-09-02 Time 08:41 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-05-23 Cont ID  
Sent By tgordon Date 2008-05-23 Time 16:14 Rev Time 1.15
Received By tgordon Date 2008-05-23 Time 16:14 Sent To P
Notes
2008-05-23 16:40:09PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS LINE 11B IS SHOWING FOR THIRD
 FLOOR SYSTEM THE SUPPLY AND RETURN AIR DUCTS IN A
 CONDITIONED SPACE AND THE AIR HANDLER INTERIOR, THE
 PLANS PAGE M3 SHOWS IT ALL TO BE IN THE ATTIC. PLEASE
 CORRECT, PER 2004 FBC 13-600.3.A.
  
 2) PLEASE SUBMIT TWO COPIES OF THE ENERGY AND COOLING
 LOAD CALCULATIONS, AS ONLY ONE COPY WAS SUBMITTED. PER
 2004 W.P.B. AMEND. 106.1.
  
 3) WHEN RESUBMITTING THE REVISED ENERGY CALCULATIONS
 THEY WILL NEED TO BE SIGNED BY THE PREPARER AND THE
 OWNER/AGENT, PER 2004 FBC 13-600.3.ABC.2 AND
 13-600.3.A.
  
 4) PLEASE LABEL ALL A/C SYSTEMS AND EQUIPMENT AS #1 OR
 #2, SEE RED LINE ON PLANS M1, M2, AND M3. PER 2004 FBC
 106.1.1.
  
 5)A/C SYSTEM #2 MODEL NUMBERS UAND-018JAZ WITH
 UHLA-HM3617JA LISTED ON THE A/C EQUIPMENT SCHEDULE
 COULD NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE. I
 BELIEVE THE AIR HANDLER MODEL NUMBER YOU NEED IS
 UHLA-HM2417 (SEE ATTACHED ARI CERTIFICATE). PLEASE
 CORRECT OR SUBMIT AN ARI CERTIFICATE, SEE 2004 FBC
 13-407.1.ABC.3.1.1 OR 13-607.1.ABC.3.1.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2009-03-16 Cont ID  
Sent By kstevens Date 2009-03-16 Time 14:55 Rev Time 0.00
Received By kstevens Date 2009-03-16 Time 14:54 Sent To M
Notes
2009-03-16 14:56:04REVISION OK -- SHT M4 SANITARY RISER DIAGRAM

Review Stop P PLUMBING
Rev No 4 Status F Date 2008-12-01 Cont ID  
Sent By kstevens Date 2008-12-01 Time 14:58 Rev Time 0.00
Received By kstevens Date 2008-12-01 Time 14:58 Sent To  
Notes
2008-12-01 15:14:37DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. SHT M4 SANITARY RISER DIAGRAM REVISION FOR PLUMBING
 RISER DOES NOT SHOW A NEW REVISION NUMBER NOR DOES IT
 SHOW THE CLOUDING REQUIRED. TURN OFF ALL PREVIOUS
 CLOUDS FROM REVISION NUMBER ONE AND SHOW THE CLOUD FOR
 REVISION 2. ALSO SHOW A REVISION NUMBER TWO FOR THE
 SECOND REVISION WITH ASSOCIATED DATE OF REVISION IN
 REVISION INDEX. SECTION 106.1.3.
  
 2. SHT M4 SANITARY RISER DIAGRAM REVISION DOES NOT
 REFLECT THE FLOOR PLAN. AS INDICATED THE NEW POWDER
 ROOM IS SHOWN ON THE FIRST FLOOR AND THE FIXTURES DO
 NOT REFLECT THE LOCATION INDICATED ON THE FLOOR PLAN. A
 CLEANOUT IS REQUIRED AT THE BASE OF THE STACK TO THE
 SECOND FLOOR. SECTIONS 106.1.1 & 708.3.4.
  
 3. SHT M4 SANITARY RISER DIAGRAM REVISION FOR THE WASH
 MACHINE DOES NOT REFLECT THE FLOOR PLAN. AS SHOWN THE
 WASH MACHINE STACK IS NOT IN THE WALL AND THE STANDPIPE
 IS NOT SHOWN, (MINIMUM 18" REQUIRED), AND A CLEANOUT IS
 REQUIRED MINIMUM 4 FEET ABOVE THE FLOOR. SECTIONS
 106.1.1, 708.9, 802.4 & 1002.1.
  
 4. INFORMATIONAL: TO DETERMINE IF THE SANITARY RISER
 DIAGRAM REFLECTS THE FLOOR PLAN, DRAW A PLAIN VIEW
 FLOOR PLAN WITH THE SANITARY PIPING SHOWN ON THE FLAT
 AND COMPAIR THE RISER TO THE FLOOR PLAN.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-09-03 Cont ID  
Sent By mperson Date 2008-09-03 Time 14:52 Rev Time 0.00
Received By mperson Date 2008-09-03 Time 14:52 Sent To B
Notes
2008-09-03 14:54:51NOTE: CONTRACTOR BROUGHT IN MISSING M4 PLUMBING RISERS.
 PER LUIS MARTINEZ "OK" TO REVIEW IF NO OTHER TRADES ARE
 ON SHEET. PER PERMIT APPLICATION ONLY UNIT THREE TO BE
 REVIEWED. *MRPERSON.

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-08-29 Cont ID  
Sent By mperson Date 2008-08-29 Time 14:37 Rev Time 0.00
Received By mperson Date 2008-08-29 Time 14:37 Sent To M
Notes
2008-08-29 14:41:48PLUMBING PLAN REVIEW:
 DENIED **2ND TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 **THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND
 WITH THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS
 THE DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. SHEET M4 UNIT THREE FIRST AND SECOND FLOOR SANATRY
 PLUMBING RISERS: PLEASE CORRECT THE FOLLOWING PER
 FBC-2004 PLUMBING THE FOLLOWING SECTIONS.
  
 A} KITCHEN SINK REQUIRES A VENT. PLEASE CLEARLY
 INDICATE A VENT ON THE RESUBMITTAL. PER SECTION 901.2.1
 VENTING REQUIRED.
  
 B} KITCHEN SINK DOES NOT REFLECT THE FLOOR PLAN. SHEET
 A2 UNIT THREE FLOOR PLAN INDICATES A DOUBLE BOWL
 KITCHEN SINK WITH A DISHWASHER, HOWEVER THE SANITARY
 RISER ON SHEET M4 IS ONLY INDICATING A SINGLE BOWL
 SINK. AT A MINIMUM THE RISER DIAGRAM SHALL REFLECT THE
 FLOOR PLAN. PER SECTION 701.1 SCOPE.
  
 C} THE SOIL STACK FOR THE FIRST, SECOND AND THIRD FLOOR
 REQUIRES A CLEANOUT AT THE BASE OF THE STACK. PER
 708.3.4 BASE OF STACK.
  
 D} CLEARLY INDICATE THAT A TWO-WAY CLEANOUT SHALL BE
 INSTALLED AT THE JUNCTION OF THE BUILDING DRAIN AND
 BUILDING SEWER. PER SECTION 708.3.5 BUILDING DRAIN AND
 BUILDING SEWER JUCTION.
  
 **RESPONSE NOTED, HOWEVER THE RESUBMITTED PLANS DO NOT
 HAVE SHEET M-4 PLUMBING RISERS IN THEM TO REVIEW.
 PLEASE KNOW THAT TWO COPIES OF SHEET M-4 PLUMBING
 RISERS ARE REQUIRED FOR PLUMBING PLAN REVIEW. PER
 (W.P.B. AS AMENDED) SECTION 106.1 SUBMITTAL DOCUMENTS.
  
 2."OK" COMMENT ADDRESSED.
  
 3. "OK" COMMENT ADDRESSED.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-06-02 Cont ID  
Sent By mperson Date 2008-06-02 Time 15:38 Rev Time 0.00
Received By mperson Date 2008-06-02 Time 15:37 Sent To B
Notes
2008-06-02 16:03:59PLUMBING PLAN REVIEW UNIT THREE:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 1. SHEET M4 UNIT THREE FIRST AND SECOND FLOOR SANATRY
 PLUMBING RISERS: PLEASE CORRECT THE FOLLOWING PER
 FBC-2004 PLUMBING THE FOLLOWING SECTIONS.
  
 A} KITCHEN SINK REQUIRES A VENT. PLEASE CLEARLY
 INDICATE A VENT ON THE RESUBMITTAL. PER SECTION 901.2.1
 VENTING REQUIRED.
  
 B} KITCHEN SINK DOES NOT REFLECT THE FLOOR PLAN. SHEET
 A2 UNIT THREE FLOOR PLAN INDICATES A DOUBLE BOWL
 KITCHEN SINK WITH A DISHWASHER, HOWEVER THE SANITARY
 RISER ON SHEET M4 IS ONLY INDICATING A SINGLE BOWL
 SINK. AT A MINIMUM THE RISER DIAGRAM SHALL REFLECT THE
 FLOOR PLAN. PER SECTION 701.1 SCOPE.
  
 C} THE SOIL STACK FOR THE FIRST, SECOND AND THIRD FLOOR
 REQUIRES A CLEANOUT AT THE BASE OF THE STACK. PER
 708.3.4 BASE OF STACK.
  
 D} CLEARLY INDICATE THAT A TWO-WAY CLEANOUT SHALL BE
 INSTALLED AT THE JUNCTION OF THE BUILDING DRAIN AND
 BUILDING SEWER. PER SECTION 708.3.5 BUILDING DRAIN AND
 BUILDING SEWER JUCTION.
  
 2. PER (W.P.B. AS AMENDED) SECTION 106.1 SUBMITTAL
 DOCUMENTS. CONSTRUCTION DOCUMENTS, SPECIAL INSPECTION
 AND STRUCTURAL OBSERVATION PROGRAMS, AND OTHER DATA
 SHALL BE SUBMITTED IN TWO OR MORE SETS WITH EACH
 APPLICATION FOR A PERMIT.
 NOTE: ONLY ONE SET OF ENERGY AND COOLING CALCULATIONS
 WAS SUBMITTED.
  
 3. RESUBMITTED ENERGY CALCULATIONS NEED TO BE SIGNED BY
 THE PREPARER AND THE OWNER/AGENT. PER FBC-2004
 13-600.3.ABC.2 AND 13-600.3.A.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 7 Status P Date 2009-10-22 Cont ID  
Sent By eschneid Date 2009-10-22 Time 14:55 Rev Time 0.25
Received By eschneid Date 2009-10-22 Time 14:55 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 6 Status F Date 2009-09-14 Cont ID  
Sent By eschneid Date 2009-09-14 Time 17:10 Rev Time 0.25
Received By eschneid Date 2009-09-14 Time 17:10 Sent To ENG
Notes
2009-09-14 17:11:44FAILED
  
 1) ALL PLANS SHALL BE CONSISTENT.
  
 2) ADDRESS ALL LANDSCAPE REVIEWER COMMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.

Review Stop Z ZONING
Rev No 5 Status P Date 2009-05-27 Cont ID  
Sent By mcruz Date 2009-05-27 Time 13:28 Rev Time 0.00
Received By mcruz Date 2009-05-27 Time 13:28 Sent To  
Notes
2009-05-27 13:28:46PASSED W/PROVISO: LANDSCAPE AND IRRIGATION PLAN(S)
 SHALL BE APPROVED PRIOR TO FINAL C.O.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 4 Status F Date 2009-04-06 Cont ID  
Sent By mcruz Date 2009-04-06 Time 12:11 Rev Time 0.00
Received By mcruz Date 2009-04-06 Time 12:07 Sent To I
Notes
2009-04-06 12:11:27PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. IT APPEARS THAT THE 1ST FLOOR LAYOUT OF UNIT # 3 ON
 SHEET A-1 HAS BEEN RECONFIGURED THEN WHAT WAS
 PREVIOUSLY APPROVED. AS A RESULT, IT APPEARS THAT A
 COLUMN OF THE ATTACHED FRONT PORCH AREA MAY BE
 ENCROACHING INTO THE FRONT SETBACK. PLEASE PROVIDE A
 SITE PLAN/SURVEY SHOWING WHERE THE FRONT PORCH IS NOW
 GOING TO BE LOCATED.
  
 PURSUANT TO THE ZLDR, SECTION 94-72(A)(2):
 SINGLE-FAMILY LOW DENSITY (SF7) RESIDENTIAL DISTRICT -
 MINIMUM SETBACKS FOR PRINCIPAL BUILDING ARE AS FOLLOWS:
  
 A. FRONT: 25 FEET;
  
 B. CORNER: 12.5 FEET;
  
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
  
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2008-09-17 Cont ID  
Sent By mcruz Date 2008-09-17 Time 12:58 Rev Time 0.00
Received By mcruz Date 2008-09-17 Time 12:55 Sent To B
Notes
2008-09-17 12:50:52APPROVED FOR UNIT #3 ONLY. PER CONTRACTOR - UNIT #'S 1
 AND 2 WILL BE SUBMITTED AT A LATER DATE.

Review Stop Z ZONING
Rev No 2 Status F Date 2008-08-28 Cont ID  
Sent By mcruz Date 2008-08-28 Time 09:25 Rev Time 0.00
Received By mcruz Date 2008-08-28 Time 09:17 Sent To E
Notes
2008-08-28 09:25:08***ZONING FAILED 1ST RESUB***
  
 1.PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. AS DISCUSSED, SCOPE OF WORK SHALL BE CLEARLY MARKED
 ON SITE PLAN.IF SUBMITTING FOR ONE UNIT, THIS MUST BE
 ILLUSTRATED ON PLAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL:(561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
2008-08-27 17:00:53ROUTED TO ELECTRICAL 8/27/08

Review Stop Z ZONING
Rev No 1 Status F Date 2008-05-21 Cont ID  
Sent By choops Date 2008-05-21 Time 10:12 Rev Time 0.00
Received By choops Date 2008-05-21 Time 10:12 Sent To E
Notes
2008-05-21 10:47:49***FAILED***
  
  
 1)PROVIDE TWO (2) COPIES OF ALL SUBMITTED PLANS
 (SURVEYS).
  
 2)PURSUANT TO SECTION 94-482 OF THE CITY'S ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDRS): REQUIRED
 OFF-STREET PARKING SPACES FOR LESS THAN FOUR
 RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE
 PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED
 PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE
 LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT
 YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN
 THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH,
 NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION
 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO
 PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE.
  
  
 PLEASE INDICATE SQUARE FOOTAGE AND DIMENSIONS OF ALL
 IMPERMEABLE SURFACES (EXISTING AND PROPOSED) LOCATED
 WITHIN THE FRONT YARD (FROM FRONT PROPERTY LINE TO THE
 FRONT BUILDING FACADE).
  
 3)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION
 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 4)INDICATE THE GARAGE DOOR AREA OVERHANGS, WITH
 DIMENSIONS, ON THE SITE PLAN (SHEET SP-1).PURSUANT TO
 SECTION 94-305 OF THE ZLDRS:STRUCTURAL INTRUSIONS.
 STRUCTURAL OVERHANGS, INCLUDING BUT NOT LIMITED TO
 BALCONIES, CORNICES, GUTTERS, EAVES, AND ROOF OVERHANG
 PROJECTIONS SHALL NOT EXTEND FARTHER THAN THREE FEET
 INTO ANY SETBACK.
  
 5)INDICATE HOW FAR THE COVERED PATIO OVERHANG
 PROJECTS INTO THE REQUIRED FRONT SETBACK OF 25'.
 PURSUANT TO SECTION 94-305 OF THE ZLDRS:STRUCTURAL
 INTRUSIONS.STRUCTURAL OVERHANGS, INCLUDING BUT NOT
 LIMITED TO BALCONIES, CORNICES, GUTTERS, EAVES, AND
 ROOF OVERHANG PROJECTIONS SHALL NOT EXTEND FARTHER THAN
 THREE FEET INTO ANY SETBACK.
  
 6)THE LANDSCAPE PLAN (SHEET LA-1) INDICATES THE
 INCORRECT ADDRESS FOR THE PROPERTY.PLEASE CLARIFY.
  
 7)THE LOT AREA CALCULATIONS ON SHEET SP-1 AND LA-1
 DO NOT CORRELATE.PLEASE CLARIFY WHICH IS ACCURATE AND
 REVISE PLANS ACCORDINGLY.
  
 8)OPEN SPACE CALCULATIONS ON THE LANDSCAPE PLAN
 (SHEET LA-1) ARE NOT ACCURATE.PURSUANT TO SECTION
 94-442(B)(3) OF THE ZLDRS:THE TOTAL OPEN SPACE AREA
 REQUIRED SHALL DETERMINE THE NUMBER OF TREES AND SHRUBS
 TO BE PLANTED. THE TOTAL AMOUNT OF PLANT MATERIAL
 REQUIRED SHALL NOT BE AFFECTED BY THAT PORTION OF THE
 OPEN SPACE AREA DEVOTED TO ACTIVE RECREATION PURPOSES,
 PATIOS, TERRACES, PEDESTRIAN CIRCULATION, AND SIMILAR
 AMENITIES.THEREFORE, ONLY THE BUILDING FOOTPRINT
 SQUARE FOOTAGE SHALL BE SUBTRACTED FROM THE TOTAL LOT
 AREA WHEN CALCULATING THE OPEN SPACE.REVISE PLANS
 ACCORDINGLY.
  
 9)I APOLOGIZE AS THE INCORRECT LANDSCAPE CODE
 SECTION WAS CITED UNDER THE MAJOR WORKING DRAWING
 REVIEW, HOWEVER,PLANS SHALL INDICATE COMPLIANCE WITH
 SECTION 94-443(D) OF THE ZLDRS:
  
 ADDITIONAL LANDSCAPING REQUIREMENTS FOR MULTIFAMILY
 RESIDENTIAL USES.THE OWNER OF PROPERTY USED FOR
 MULTIFAMILY RESIDENTIAL USES SHALL INSTALL AND MAINTAIN
 THE FOLLOWING LANDSCAPING:
  
 (1.)A LANDSCAPE BUFFER SHALL BE REQUIRED FOR
 MULTIFAMILY RESIDENTIAL USES ADJACENT TO A PUBLIC
 THOROUGHFARE. SUCH A LANDSCAPE BUFFER SHALL BE AT LEAST
 FIVE FEET IN WIDTH FOR FOUR OR LESS MULTIFAMILY
 DWELLINGS.A LANDSCAPE BUFFER OF AT LEAST FIVE FEET IN
 WIDTH IS ALSO REQUIRED ALONG THE MULTIFAMILY
 RESIDENTIAL USE AND THE ADJACENT PROPERTIES. THE BUFFER
 STRIP SHALL BE DESIGNED AND LANDSCAPED AS REQUIRED BY
 THE FOLLOWING:
 A.THE BUFFER STRIP SHALL NOT BE INTERRUPTED AT
 MORE THAN 20 PERCENT OF ITS REQUIRED LENGTH TO PROVIDE
 VEHICULAR INGRESS AND EGRESS.
 B.ALL PORTIONS OF THE BUFFER STRIP SHALL BE
 COVERED WITH GRASS, GROUND COVER, SHRUBBERY, MULCH, OR
 OTHER SUITABLE PLANT MATERIAL.
 C.AT LEAST ONE TREE SHALL BE PLANTED IN A
 REQUIRED BUFFER STRIP FOR EACH 30 LINEAR FEET OR
 PORTION THEREOF.
 (2.)SHADE TREES TO BE PLANTED AND LANDSCAPED ON THE
 EXTERIOR OF ALL STRUCTURES AS REQUIRED BY THE
 FOLLOWING:
 A.AT LEAST TWO SHADE OR FLOWERING TREES FOR EACH
 DWELLING UNIT FOR MULTIFAMILY RESIDENTIAL STRUCTURES.
 B.AT LEAST 40 PERCENT OF THE LINEAR FEET AROUND
 THE EXTERIOR OF ALL STRUCTURES SHALL BE PLANTED WITH
 TREES, SHRUBS OR HEDGES.
 C.ALL REMAINING, NONPAVED AREAS SHALL BE COVERED
 WITH GRASS, GROUND COVER, MULCH OR CONTAIN BEDS OF
 PRESERVED NATIVE SHRUBS.
  
 10)LANDSCAPE PLANS SHALL INDICATE COMPLIANCE WITH
 SECTION 94-445 (PLANT MATERIAL STANDARDS AND
 SPECIFICATIONS) AND 94-448(2) (LANDSCAPE PLANS
 REQUIREMENTS) OF THE ZLDRS.
  
  
 NOTE:A SEPARATE RIGHT-OF-WAY PERMIT IS REQUIRED FOR
 ANY/ALL APPROACHES/APRONS PROPOSED OUTSIDE OF THE
 PROPERTY LINES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - SF RACK