Plan Review Details - Permit 08050545
Plan Review Stops For Permit 08050545
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-06-20 Cont ID  
Sent By mjacobs Date 2008-06-20 Time 16:24 Rev Time 0.00
Received By mjacobs Date 2008-06-20 Time 16:03 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-29 Cont ID  
Sent By mjacobs Date 2008-05-29 Time 15:46 Rev Time 0.00
Received By mjacobs Date 2008-05-29 Time 14:54 Sent To  
Notes
2008-05-29 15:44:39BUILDING PLAN REVIEW
 PERMIT: 08050545
 ADD: 525 S. FLAGLER DR. #11D
 CONT: GREGORY GIULIANO CONST.
 TEL: (561)301-1519
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 5/29/08
 REVIEW: 1ST
 ACTION: DENIED
  
 1)WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 3)2004 FBC EXISTING 301.5 THE DESIGN PROFESSIONAL
 MUST ELECT ONE OR A COMBINATION OF LEVELS OF ALTERATION
 PURSUANT TO SECTIONS 303, 304 AND 305 OF THIS CODE.
 INDICATE THE LEVEL OF ALTERATION ON THE DRAWINGS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-06-12 Cont ID  
Sent By btrobaug Date 2008-06-12 Time 16:38 Rev Time 0.00
Received By btrobaug Date 2008-06-12 Time 16:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-05-23 Cont ID  
Sent By btrobaug Date 2008-05-23 Time 10:37 Rev Time 0.00
Received By btrobaug Date 2008-05-23 Time 10:31 Sent To  
Notes
2008-05-23 10:37:48 
 PROVISO
  
 PLANS ARE COMPLIANT WITH THE 2005 NEC AS SUBMITTED.
 MECHANICAL COMMENTS AND RESPONCE MAY GENERATE
 ELECTRICAL COMMENTS.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-06-19 Cont ID  
Sent By mawillia Date 2008-06-19 Time 13:41 Rev Time 0.00
Received By mawillia Date 2008-06-19 Time 13:26 Sent To  
Notes
2008-06-19 13:36:16*****APPROVED*****
  
  
 PLAN SHEET A.02 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2008-05-30 Cont ID  
Sent By mwennerg Date 2008-05-30 Time 13:55 Rev Time 0.00
Received By mwennerg Date 2008-05-30 Time 13:55 Sent To  
Notes
2008-05-30 13:57:47***PROVISO***
  
 1) SHOW HARD WIRED SMOKE ALARMS IF IMPACTED BY THIS
 SCOPE OF WORK.
  
 2) SEPARATE SHOP DRAWINGS AND PERMIT MAY BE REQUIRED
 FOR FIRE SPRINKLER REMODEL IF APPLICABLE.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-10 Cont ID  
Sent By adarroug Date 2008-06-10 Time 14:02 Rev Time 0.00
Received By adarroug Date 2008-06-10 Time 14:02 Sent To  
Notes
2008-06-10 14:03:50TO "BOB"#9

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-10 Cont ID  
Sent By adarroug Date 2008-05-30 Time 13:57 Rev Time 0.00
Received By adarroug Date 2008-05-21 Time 09:05 Sent To  
Notes
2008-05-21 09:08:05TO "BOB"#4

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-06-10 Cont ID  
Sent By tgordon Date 2008-06-10 Time 16:43 Rev Time 0.20
Received By tgordon Date 2008-06-10 Time 16:43 Sent To  
Notes
2008-06-10 16:45:08REPLACING EXISTING BATHROOM EXHAUST FANS ONLY.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-05-22 Cont ID  
Sent By tgordon Date 2008-05-22 Time 14:15 Rev Time 0.20
Received By tgordon Date 2008-05-22 Time 14:14 Sent To  
Notes
2008-05-22 14:21:40PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) PERMIT APPLICATION STATES A/C WORK PER PLAN, PLANS
 STATE NEW A/C LAYOUT, BUT NO MECHANICAL PLANS WERE
 SUBMITTED. PLEASE SUBMIT MECHANICAL PLAN SHOWING ALL
 MECHANICAL WORK TO BE DONE, FOR REVIEW, PER 2004 FBC
 106.3.6.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-06-20 Cont ID  
Sent By mperson Date 2008-06-20 Time 14:44 Rev Time 0.00
Received By mperson Date 2008-06-20 Time 14:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-05-29 Cont ID  
Sent By mperson Date 2008-05-29 Time 13:30 Rev Time 0.00
Received By mperson Date 2008-05-29 Time 13:30 Sent To  
Notes
2008-05-29 14:19:46PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET A.01 DETAIL 1, EXISTING/DEMOLITION PLAN:
 INDICATES ONE LAVATORY IN DRESSING AND ONE BIDET IN THE
 MASTER BATH BEING DELETED. PLEASE ADD THE FOLLOWING TO
 NOTES PER FBC-2004 PLUMBING, SECTION 704.5 DEAD ENDS:
 IN THE INSTALLATION OR REMOVAL OF ANY PART OF A
 DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. A
 PLUMBING PERMIT IS REQUIRED AND AN INSPECTION IS
 REQUIRED OF PLUMBING DEMO WORK PRIOR TO COVERING DEMO
 WORK WITH FINNISH WALLS, CIELINGS, OR POURED CONCRETE
 SLABS.
  
 2. PROVIDE A DETAIL ON HOW THE SLEEVE HOLE FOR THE
 BIDET WILL BE SAFEGUARDED AGAINST THE SPREAD OF FIRE
 AND SMOKE WHEN THE DRAINAGE PIPE IS REMOVED. PER
 FBC-2004 BUILDING SECTION 701.1 SCOPE.
  
 3. SHEET A.01 DETAIL 2, NEW FRAMING PLAN: CLEARLY
 INDICATE THE SCOPE OF WORK IN THE POWDER ROOM. DEMO
 PLAN INDICATED PLUMBING FIXTURES BEING REMOVED, HOWEVER
 THERE IS NO INDICATION IF THE OLD PLUMBING FIXTURES ARE
 BEING REINSTALLED OR IF NEW ONES ARE BEING INSTALLED.
 PLEASE CLARIFY THIS ON THE RESUBMITTAL. PER (W.P.B.AS
 AMENDED) SECTION 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 4. SHEET A.01 DETAIL 2, NEW FRAMING PLAN: CLEARLY
 INDICATE ON THE RESUBMITTED PLANS IF A NEW KITCHEN SINK
 OR THE OLD KITCHEN SINK IS BEING INSTALLED IN THE NEW
 KITCHEN COUNTER TOP. PLEASE ALSO INDICATE THE KITCHEN
 SINKS LOCATION. PER (W.P.B. AS AMENDED) SECTION 106.1.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 5. SHEET A.01 DETAIL 2, NEW FRAMING PLAN: CLEARLY
 INDICATE THAT THE GLASS DOOR IN THE NEW IN THE GUEST
 BATH COMPLIES WITH FBC-2004 PLUMBING SECTION 417.6
 GLAZING.WINDOWS AND DOORS WITHIN A SHOWER ENCLOSURE
 SHALL CONFORM TO THE SAFETY GLAZING REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING SECTION 2406 HAZARDOUS
 LOCATIONS.(5)
  
 6. PROVIDE A SANITARY AND POTABLE WATER ISOMETRIC
 RISER DIAGRAM OF THE PROPOSED NEW LAVATORY BEING
 INSTALLED IN THE MASTER BATHROOM. PER (W.P.B.AS
 AMENDED) SECTION 106.3.5.1.3 PLUMBING
 (3)(4)(6)(10)(13).
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-05-27 Cont ID  
Sent By choops Date 2008-05-27 Time 11:03 Rev Time 0.00
Received By choops Date 2008-05-27 Time 11:03 Sent To  
Notes
2008-05-27 11:04:01*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.