Plan Review Details - Permit 08050540
Plan Review Stops For Permit 08050540
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-21 Cont ID  
Sent By jwitmer Date 2008-10-21 Time 15:01 Rev Time 1.22
Received By jwitmer Date 2008-10-21 Time 15:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-09-11 Cont ID  
Sent By jwitmer Date 2008-09-11 Time 08:17 Rev Time 2.22
Received By jwitmer Date 2008-09-11 Time 08:17 Sent To  
Notes
2008-09-11 08:36:57BUILDING PLAN REVIEW
 PERMIT: 08050540
 ADD: 6650 45TH ST.
 CONT: SBA NETWORK SERVICES
 TEL: (352)629-1774
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS,
 PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR
 SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL
 REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A
 THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN
 (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED
 FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS
 WEST PALM BEACH ADMINISTRATIVE CODE.
  
 1C) COMPLIED.
  
 1D ) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 1E)COMPLIED.
  
 1F) 2ND REQUEST, PLEASE FILL OUT ALL PAPERWORK WITH THE
 CORRECTED ADDRESS ON THE PERMIT APPLICATION AND ALL
 OTHER DOCUMENTS. THE CITY'S ADDRESSING DEPARTMENT HAS
 DETERMINED THAT THE CURRENT ADDRESS IS OUT OF THE
 CITIES RANGE, THE NEW ADDRESS FOR THIS PCN WILL BE 6650
 45TH STREET AND SHOULD BE USED ON ALL PLANS, PERMIT
 APPLICATION AND CORRESPONDANCE.
  
 2) COMPLIED.
  
 3-7) COMPLIED.
  
 8) SHEET S-2:
 8A) INDICATES SOILS INVESTIGATION HAS BEEN COMPLETED.
 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING
 POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING
 VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS
 CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE
 NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION
 SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4
 THROUGH 1802.6 .
  
 NEW COMMENT:
  
 9) IN BOTH SETS OF PLANS SUBMITTED FOR REVIEW ONLY THE
 FRONT SHEET HAS BEEN SIGNED AND SEALED. PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY
 THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN
 PROFESSIONAL AFFIXED TO THE DOCUMENT. FL ADMIN CODE
 61G16.003 ARCHITECTS
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-06-16 Cont ID  
Sent By jwitmer Date 2008-06-16 Time 16:57 Rev Time 1.55
Received By jwitmer Date 2008-06-17 Time 07:36 Sent To  
Notes
2008-06-17 08:43:09BUILDING PLAN REVIEW
 PERMIT: 08050540
 ADD: 6650 45TH ST.
 CONT: SBA NETWORK SERVICES
 TEL: (352)629-1774
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS,
 PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR
 SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL
 REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A
 THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN
 (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED
 FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS
 WEST PALM BEACH ADMINISTRATIVE CODE.
  
 1C) INFORMATIONAL 106.1.1* W.P.B. ADMINISTRATIVE
 CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO
 THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION
 SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) INFORMATIONAL FL S S 713.13 NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT.
 NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.PLEASE UPDATE THE
 STRUCTURAL ANALYSIS REPORT & THE STRUCTURAL SHEET S-1 &
 T-1.
  
 1F) THE CITY'S ADDRESSING DEPARTMENT HAS DETERMINED
 THAT THE CURRENT ADDRESS IS OUT OF THE CITIES RANGE,
 THE NEW ADDRESS FOR THIS PCN WILL BE 6650 45TH STREET
 AND SHOULD BE USED ON ALL PLANS, PERMIT APPLICATION AND
 CORRESPONDANCE.
  
 2) AMERICAN TOWER ENGINEERING SERVICES -STRUCTURAL
 ANALYSIS REPORT DOES NOT INDICATE THERE CERTIFICATE OF
 AUTHORIZATION NUMBER. 481.219 F.S. CERTIFICATE OF
 AUTHORIZATION. THE TITLE BLOCK FOR ANY SHEET BEARING
 THE NAME OF AN ARCHITECT PRACTICING UNDER A FICTITIOUS
 NAME, A CORPORATION, OR A PARTNERSHIP, OFFERING
 ARCHITECTURAL SERVICES, SHALL INCLUDE THE CERTIFICATE
 OF AUTHORIZATION NUMBER. ADD THE NUMBER TO EACH SHEET.
 WE COULD NOT FIND YOUR COA NUMBER ON THE DEPARTMENT OF
 BUSSINESS & PROFESSIONAL REGULATION WEBSSITE, PLEASE
 PROVIDE. THIS MAY BE ADDED BY HAND.
  
 3) ENGINEER JASON SEAVERSON - AMERICAN TOWER STRUCTURAL
 ANALYSIS REPORT HAS SIGNED AND SEALED THIS DOCUMENT BUT
 MISSING HIS PRINTED NAME AND LICENSE NUMBER, PLEASE
 CORRECT.
 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & SEALED
 BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER THE:
 NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER OR,
 THE NAME AND LICENSE NUMBER OF THE ENGINEER AND THE
 NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS THROUGH WHICH THE ENGINEER
 IS PRACTICING (471.025 F.S. AND 471.023 F.S.).
  
 4) ENGINEER JASON SEAVERSON - AMERICAN TOWER STRUCTURAL
 ANALYSIS REPORT DOES NOT INDICATE HOW MANY SHEETS ARE
 WITHIN THE DOCUMENT AND HAS ONLY SIGNED AND SEALED THE
 COVER SHEET, PLEASE CORRECT. 61G15-23.002(2) FL. ADMIN.
 CODE. A COVER SHEET OR INDEX SHEET FOR ENGINEERING
 SPECIFICATIONS MAY BE USED AND THAT SHEET MUST BE
 SIGNED IN RESPONSIBLE CHARGE OF THE PRODUCTION &
 PREPARATION OF EACH SECTION OF THE ENGINEERING
 SPECIFICATION WITH SUFFICIENT INFORMATION ON THE COVER
 SHEET OR INDEX.
  
 5) STRUCTURAL ANALYSIS REPORT PAGE 1 IT APPEARS THERE
 MAY BE CONFLICTS WITH SECTIONS OF THE CODE: DESIGNS ARE
 TO ASCE 7-02,
  
 5A) THE STRUCTURAL CLASSIFICATION OF THE STRUCTURE IS A
 CLASS II, PLEASE SEE ASCE 7-02 TABLE 1-1,
 COMMUNICATIONS TOWERS ARE LISTED AS A TYPE IV STRUCTURE
 , CELL PHONES ARE USED AS PART OF THE RECOVERY EFFORT
 FOR HIGH WIND EVENTS, PLEASE SEE TABLE 6-1 IMPORTANCE
 FACTOR FOR BUILDING CATEGORY IV= 1.15 NOT THE 1.0
 LISTED .
  
 5B) LOAD CASE IS INDICATED AS 1.2D+1.6W PLEASE SEE
 1605.2 BASIC LOAD COMBINATIONS 0.9D+(1.6W) IS THE MORE
 RESTRICTIVE DESIGN WHICH SHOULD HAVE BEEN USED IN THIS
 CASE. 1605.2.1 WHERE STRENGTH DESIGN OR LOAD AND
 RESISTANCE FACTOR DESIGN IS USED, STRUCTURES AND
 PORTIONS THEREOF SHALL RESIST THE MOST CRITICAL EFFECTS
 FROM THE FOLLOWING COMBINATIONS OF FACTORED LOADS.
  
 PLEASE RUN THE LOADING CALCULATIONS WITH THESE
 ADJUSTMENT FACTORS TO MEET THE CURRENT WIND LOADING
 CRITERIA. THE CALCULATIONS MAY EXCEED THE 5% ADDITIONAL
 GRAVITY LOADS ALLOWED UNDER THE 2004 FBC EXISTING
 BUILDING CODE 903.2, EXCEPTION# 1.
  
 6) PLANS INDICATE ON SHEET T-1 130 MPH WIND ZONE PLEASE
 CORRECT TO 140 MPH SEE FIGURE 1609.
  
 7) SHEET A-3 INDICATES THE USE OF A STATE APPROVED AT&T
 EQUIPMENT SHELTER, PLEASE PROVIDE (2) COPIES OF THE
 STATE STATE APPROVED PLANS FOR MODULAR BUILDINGS 428.1,
 RULE 9B-1 FLORIDA ADMINISTRATIVE CODE AND CHAPTER 553
 FL S S .
  
 8) SHEET S-1:
 8A) FOUNDATION NOTE# 2 INDICATES SOILS TEST ARE TO BE
 COMPLETED, 1802.2.1 QUESTIONABLE SOIL. WHERE THE
 SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE
 A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS
 CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE
 THAT THE NECESSARY INVESTIGATION BE MADE. SUCH
 INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF
 SECTIONS 1802.4 THROUGH 1802.6 .
  
 8B) FOUNDATION NOTE # 2 INDECATES THE DESIGN TO THE
 2004 FBC WITH 2006 REVISIONS, PLEASE UPDATE TO THE 2007
 FBC REVISIONS, PLANS SUBMITTED AFTER JULY 1,2007 ARE TO
 BE DESIGNED TO THE 2007 WIND PROVISIONS.
  
 8C) FOUNDATION NOTE# 2 PLEASE REVISE WIND INFORMATION
 TO 140MPH, 3 SECOND GUST ,PLEASE SEE FIGURE 1609.
  
 8D) FOUNDATION NOTE# 2 PLEASE REVISE BUILDING CATEGORY
 TO A CATEGORY IV ASCE 7-02 TABLE 6-1.
  
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-10-21 Cont ID  
Sent By dpalmer Date 2008-10-21 Time 11:57 Rev Time 0.00
Received By dpalmer Date 2008-10-21 Time 11:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-09-11 Cont ID  
Sent By dpalmer Date 2008-09-11 Time 11:51 Rev Time 0.00
Received By dpalmer Date 2008-09-11 Time 11:51 Sent To  
Notes
2008-09-11 11:51:40 
  
  
  
 ** DENIED REVIEW **
  
  
  
 1) NOTE: PLANS ARE NOT SEALED WITH RAISED SEAL AS
 REQUIRED PER FS 471.025, FAC 61G15-23.002.
  
 ** THIS IS ALSO REQUIRED FOR ALL OTHER SHEETS AND
 TRADES WHETHER OR NOT COMMENT IS MADE BY OTHER TRADE
 REVIEWERS
  
 2) NOTE: BASED ON RESPONSE COMMENT FOR VALUE FOR
 COMPLETE SCOPE OF WORK. THE VALUE WAS INCREASED ON
 PERMITS 08050540 TO $238,000 AND 08050543 TO $55,000.
 FEES DUE BEFORE PERMITS CAN BE ISSUED.
  
  
  
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-06-18 Cont ID  
Sent By dpalmer Date 2008-06-18 Time 15:37 Rev Time 0.00
Received By dpalmer Date 2008-06-18 Time 15:37 Sent To  
Notes
2008-06-18 15:37:30** DENIEDREVIEW **
  
  
 1) NOTE: PLEASE SEE VALUE FOR THE COMPLETE SCOPE OF
 WORK INCLUDING ALL EQUIPMENT, DESIGN COST ETC SHALL BE
 INCLUDED EVEN IF ANY EQUIPMENT SUCH AS THE BUILDING,
 GENERATOR ETC IS OWNER SUPPLIED.
 FBC 108.3
  
 2) NOTE: PLEASE BE SURE TO SUBMIT THE MANUFACTURES
 SPECS/CUT SHEETS WHICH ACTUALLY STATE THE MINIMUM
 CLEARANCES. AS REQUIREMENTS FOR OTHER TRADES SUCH AS
 ZONING MAY REQUIRE A WALL OF SOME KIND. THE SET BACKS
 NEED TO BE SHOWN.
 NEED TO ALSO SHOW THE ACTUAL SET BACK FROM PROPERTY
 LINE AS THE MINIMUM WILL ALSO BE REQUIRED FROM PROPERTY
 LINE.
 90.7, 110.3. ETC
 FBC 106.1.2 FOR ADDITIONAL INFORMATION AND
 COORDINATION.
  
 3) NOTE: PLEASE SHOW HOW ANY TRANSFER OF POWER FROM THE
 RECEPTACLE SHOWN ON PLANS TO EQUIPMENT MEETS 701.7.
  
 4) NOTE: PLEASE STATE ON PLANS THE MINIMUM RUN TIMES
 PER FEDERAL CODE OF REGULATIONS TITLE 47, PART 12.2
  
 5) NOTE: PLEASE BE SURE TO DATE PLANS WHEN SIGNING AND
 SEALING PER FS 471.025, 481.221
  
 6) NOTE: PLEASE SHOW HOW THE BREAKER ON THE GENERATOR
 MEETS 701.11B5 FOR THE EXCEPTION OF THE REQUIRED
 DISCONNECT PER 225.361-225.39 FOR FEEDERS.
  
 7) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT
 SHEETS FOR THE PROPOSED ATS. 90.7,110.3, 701.7.
 PLEASE SEE COMMENT #3 ABOVE WHICH WILL ALSO NEED
 SPECS/CUT SHEETS.
  
  
  
 ** IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF
 THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT
 HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-10-21 Cont ID  
Sent By mawillia Date 2008-10-21 Time 12:53 Rev Time 0.00
Received By mawillia Date 2008-10-21 Time 12:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2008-09-23 Cont ID  
Sent By mwennerg Date 2008-09-23 Time 11:38 Rev Time 0.00
Received By mwennerg Date 2008-09-23 Time 11:38 Sent To  
Notes
2008-09-23 11:40:41***DENIED***
  
 1) PLANS HAVE BEEN REVISED TO ILLUSTRATE THE CORRECT
 ADDRESS. PLEASE CORRECT PERMIT APPLICATION AND ALL
 SUPPORTING DOCUMENTS TO CORRELATE INFORMATION.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-06-25 Cont ID  
Sent By mawillia Date 2008-06-25 Time 15:57 Rev Time 0.00
Received By mawillia Date 2008-06-25 Time 14:59 Sent To  
Notes
2008-06-25 15:51:42*****PROVISO*****
  
 THE APPROPIATE PLAN SHEETS TO BE FIRE-STAMPED WHEN THE
 FOLLOWING COMMENTS HAVE BEEN ADDRESSED:
  
 1.THE ACTUAL SCOPE OF WORK ADDRESS SHALL BE IN THE
 TITLE BLOCK OF EACH SUBMITTED PLAN SHEET.SEE BLDG
 EXAMINER'S COMMET # 1F
  
 2.THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE
 WITH EMERGENCY RESPONSE TO THE SAID PROPERTY OR THE
 VICINITY THEREOF (INCLUDING STREETS, ALLEYS, FIRE
 LANES, ETC) .ADD COMMENT TO AN APPROPIATE PLAN SHEET
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-10-21 Cont ID  
Sent By adarroug Date 2008-10-21 Time 11:48 Rev Time 0.00
Received By adarroug Date 2008-10-21 Time 11:48 Sent To  
Notes
2008-10-21 11:48:53TO "COMM" BD#24

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-08-26 Cont ID  
Sent By tgordon Date 2008-08-26 Time 15:53 Rev Time 0.00
Received By tgordon Date 2008-08-26 Time 15:53 Sent To  
Notes
2008-08-26 15:54:12TO "COMM" BD. #11.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-30 Cont ID  
Sent By mawillia Date 2008-06-25 Time 15:44 Rev Time 0.00
Received By mawillia Date 2008-05-20 Time 16:23 Sent To  
Notes
2008-05-22 13:35:23TO "COMM" BD#34
2008-05-20 16:23:42WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-10-07 Cont ID  
Sent By tgordon Date 2008-10-07 Time 14:27 Rev Time 0.20
Received By tgordon Date 2008-10-07 Time 14:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-09-03 Cont ID  
Sent By tgordon Date 2008-09-03 Time 08:58 Rev Time 0.30
Received By tgordon Date 2008-09-03 Time 08:58 Sent To  
Notes
2008-09-03 08:58:54PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) SITE PLANS NEED TO BE SEALED BY THE ARCHITECT
 (ROBERT J. LARA), PER FAC 61G1-16.003.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-06-09 Cont ID  
Sent By tgordon Date 2008-06-09 Time 16:26 Rev Time 0.20
Received By tgordon Date 2008-06-09 Time 16:26 Sent To  
Notes
2008-06-09 16:30:55PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
  
 1) PLANS SHOW TWO A/C UNITS ARE BEING INSTALLED IN THE
 EQUIPMENT SHELTER, PLEASE ADD AN A/C EQUIPMENT SCHEDULE
 TO THE PLANS, PER 2004 FBC 106.3.5.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2008-06-06 Cont ID  
Sent By kstevens Date 2008-06-06 Time 10:49 Rev Time 0.00
Received By kstevens Date 2008-06-06 Time 10:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2008-06-02 Cont ID  
Sent By kdfreema Date 2008-06-02 Time 14:16 Rev Time 0.00
Received By kdfreema Date 2008-06-02 Time 14:16 Sent To  
Notes
***NONE***