| Plan Review Stops For Permit 08050394 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-01 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-01 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2008-07-01 13:52:19 | ****CORRECTIONS**** | | | REVISION, NEW ROOF PANEL NOA | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF | | | RECORD, FBC*106.3.3. | | | | | | 2.THE NOA PREVIOUSLY SUBMITTED HAD A DESIGN PRESSURE | | | LIMITATION OF -91.87, -113.1 FOR FIELD, | | | PERIMETER/CORNER.THE NEW NOA HAS A LIMITATION OF | | | -50.5, -106.15.THE ENGINEER DID NOT INCLUDE WIND | | | DESIGN CRITERIA ON HIS PLAN.IF THE ENGINEER IS NOW | | | REDUCING DESIGN PRESSURE REQUIREMENTS, PLEASE INCLUDE | | | ROOF DESIGN PRESSURES EITHER WITH A LETTER OR PLAN | | | SHEET REVISION. | | | | | | 3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED IN | | | ADDITION TO THE NOA SUBMITTED.IF A FLORIDA STATE | | | PRODUCT APPROVAL IS NOT AVAILABLE, PLEASE ADVISE AND A | | | LOCAL PRODUCT APPROVAL WILL BE ISSUED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-09 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-09 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2008-06-09 16:53:14 | PROVISO - SUBMIT TRUSS ENGINEERING (REVIEWED BY DOR) | | | BEFORE FINAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-02 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-02 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2008-06-02 15:05:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.TYPE IV NONCOMBUSTIBLE IS DECLARED AS BUILDING TYPE | | | ON SHEET 1.TYPE IV IS HEAVY TIMBER, PLEASE REVISE | | | BUILDING TYPE, AND ALSO INCLUDE A OR B. | | | | | | 2.NONCOMBUSTIBLE IS DECLARED,BUT SHEET 4 NEW PARTIAL | | | FRONT ELEVATION SPECIFIES PLYWOOD.SEE FBC602. | | | | | | 3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | | FOR THE WINGUARD WINDOW AND ROOF PANELS, FAC9B72. | | | | | | 4.PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER OF | | | RECORD (SHOP DRAWING REVIEW STAMP OR LETTER), | | | FBC*106.3.3. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-09 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-09 |
Time |
16:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-03 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-03 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2008-06-03 17:46:21 | ** DENIED** | | | | | | | | | 1) NOTE:PLEASE SUBMIT THE ACTUAL LIGHTING PERFORMANCE | | | PER 13-415.2.ABC.1.1 AND .1.2. | | | PLANS SHOWS 1.25, HOWEVER BASED ON TABLES AND USE/SPACE | | | AS SHOWN ON PLANS THIS LEVEL IS HIGHER THAN THE | | | ALLOWED. | | | PLEASE KNOW THE FIXTURES AS SPECIFIED ARE TO BE | | | FLUORESCENT. IT IS UNCLEAR WHY REFERENCE TO | | | INCANDESCENT LIGHTS IS BEING MADE. | | | | | | 2) NOTE: PLEASE KNOW IF ALL OTHER REVIEWS PASS THIS | | | INFORMATION MAY BE RE-SUBMITTED ON 81/2 BY 11 SHEETS. | | | THE COMMENTS ARE MINOR FOR ELECTRICAL COMPLIANCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-26 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-26 |
Time |
15:29 |
Sent To |
B |
|
| Notes |
| 2008-06-26 15:29:30 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-06 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-06 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2008-06-06 15:57:32 | TO "COMM" BD#50 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-04 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-15 |
Time |
11:05 |
Sent To |
PC |
|
| Notes |
| 2008-05-15 11:06:12 | TO "COMM" BD#29 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-04 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-04 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2008-06-04 11:04:18 | NOTE: EXISTING ROOF DRAINAGE SYSTEM ADEQUATE FOR NEW | | | ROOF. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-05-16 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-05-16 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2008-05-16 15:56:36 | ***NOT REQUIRED*** | | | | | | NO ADDITION OF SQUARE FOOTAGE TO EXISTING STRUCTURE. |
|
|