Plan Review Details - Permit 08050380
Plan Review Stops For Permit 08050380
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-06-23 Cont ID  
Sent By rmcdouga Date 2008-06-23 Time 11:18 Rev Time 0.00
Received By rmcdouga Date 2008-06-23 Time 11:18 Sent To  
Notes
2008-06-23 11:21:08BUILDING PROVISO
  
 SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE SIMPSON
 ECC/ECCU CONNECTORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-30 Cont ID  
Sent By rmcdouga Date 2008-05-30 Time 16:05 Rev Time 0.00
Received By rmcdouga Date 2008-05-30 Time 16:05 Sent To  
Notes
2008-05-30 16:48:052004 FBC W/2007 REVISIONS
 CONSTRUCT ACCESSORY STRUCTURES (R-3)
  
 DENIED BY BUILDING
  
 1)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED. FS 713
  
 2) ON SHEET #8 THERE ARE LINES ON THE ROOF FRAMING
 PLANS THAT APPEAR TO INDICATE A HIP ROOF. PLEASE
 CLARIFY.
  
 3) SPECIFY THE CONNECTORS THAT WILL BE USED TO ATTACH
 THE 2 X 4 OUTLOOKERS TO THE GABLE TRUSS AND THE TIE
 BACK TRUSS AT THE GABLE END OVERHANGS. FBC 106.1.1*
 CITY AMENDMENTS.
  
 4) SHOW COMPLIANCE WITH FBC R SECTION 704 INSPECTION
 FOR TERMITES
 IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS
 AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6 INCHES (152 MM).
 SPECIFY THE DISTANCE FROM FINISH GRADE TO THE WALL
 COVERING.
  
 5) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED
 GRADE.
 CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND
 ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT
 ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY
 VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM)
 ELSEWHERE.
  
 6) ASTM C 926 REQUIRES STUCCO APPLIED VERTICALLY OVER A
 METAL PLASTER BASE TO BE 7/8" THICK. PLEASE CORRECT.
  
 7) SPECIFY THE INTERIOR WALL COVERING THAT WILL BE USED
 AT THE COVERED PORCH. FBC 106.1.1* CITY AMENDMENTS.
  
 8) SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED.
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE
 SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE
 ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE
 PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WITH 1/8
 INCH (3.2 MM) MINIMUM TO 1/4 INCH (6.4 MM) MAXIMUM
 OPENINGS.
 R806.2 MINIMUM AREA.
 THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS
 THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED
 EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED
 TO 1 TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE
 THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS
 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF
 THE SPACE TO BE VENTILATED AT LEAST 3 FEET (914 MM)
 ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE
 REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE
 VENTS.
  
  
 9) SPECIFY THE MATERIAL THAT WILL BE USED TO COVER THE
 ROOF SOFFIT OVERHANGS AT CARPORT AND COVERED PATIO. FBC
 106.1.1* CITY AMENDMENTS.
  
 10) SPECIFY THE WALL COVERING MATERIAL FOR THE GABLE
 ENDS AT THE CARPORT. FBC 106.1.1* CITY AMENDMENTS.
  
 11) PROVIDE A BEAM PLAN FOR THE POOL ENCLOSURE
 STRUCTURE. SPECIFY THE LOCATION OF THE BEAMS AND HOW
 THEY WILL BE ATTACHED TO THE COVERED PATIO AND EXISTING
 GARAGE. FBC 106.1.1* CITY AMENDMENTS.
  
 12) SPECIFY THE ELEVATION OF THE POOL ENCLOSURE BEAMS
 FROM GRADE AND FINISH FLOOR. FBC 106.1.1* CITY
 AMENDMENTS.
  
 13) SUBMIT PRODUCT APPROVALS FOR THE SIMPSON ECC66
 CONNECTORS. DCA RULE 9B-72.
  
 IN ORDER TO EXPEDITE PLAN REVIEW, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW THE REVIEW COMMENTS HAVE
 BEEN ADDRESSED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-05-16 Cont ID  
Sent By btrobaug Date 2008-05-16 Time 14:26 Rev Time 0.00
Received By btrobaug Date 2008-05-16 Time 14:26 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-30 Cont ID  
Sent By rmcdouga Date 2008-05-30 Time 17:00 Rev Time 0.00
Received By rmcdouga Date 2008-05-15 Time 10:53 Sent To  
Notes
2008-05-15 10:54:12TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2008-05-20 Cont ID  
Sent By tgordon Date 2008-05-20 Time 15:55 Rev Time 0.20
Received By tgordon Date 2008-05-20 Time 15:55 Sent To P
Notes
2008-05-20 15:56:28BATHROOM EXHAUST FAN ONLY.

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-05-21 Cont ID  
Sent By mperson Date 2008-05-21 Time 09:48 Rev Time 0.00
Received By mperson Date 2008-05-21 Time 09:48 Sent To B
Notes
2008-05-21 09:53:33****************PROVISO***************
 NOTE: THE FLOOR DRAIN WILL REQUIRE A TRAP PRIMER. PER
 FBC-2004 PLUMBING SECTION 1002.4 TRAP SEALS. EACH
 FIXTURE TRAP SHALL HAVE A LIQUID SEAL OF NOT LESS THAN
 2 INCHES (51 MM) AND NOT MORE THAN 4 INCHES (102 MM),
 OR DEEPER FOR SPECIAL DESIGNS RELATING TO ACCESSIBLE
 FIXTURES. WHERE A TRAP SEAL IS SUBJECT TO LOSS BY
 EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE
 INSTALLED. A TRAP SEAL PRIMER VALVE SHALL CONFORM TO
 ASSE 1018 OR ASSE 1044.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2008-06-12 Cont ID  
Sent By choops Date 2008-06-12 Time 13:19 Rev Time 0.00
Received By choops Date 2008-06-12 Time 13:19 Sent To B
Notes
2008-06-12 13:19:53***APPROVED - RESUB #1 (RESTAMPED PLANS)***
  
 PROVISO:CARPORT HEIGHT SHALL NOT EXCEED 25' MEASURED
 FROM GRADE TO THE MIDPOINT OF THE ROOF'S PITCH.
  
  
  
  
 SENT TO "B" - RMC

Review Stop Z ZONING
Rev No 1 Status P Date 2008-05-15 Cont ID  
Sent By choops Date 2008-05-15 Time 14:49 Rev Time 0.00
Received By choops Date 2008-05-15 Time 14:49 Sent To E
Notes
2008-05-15 14:51:06***APPROVED***
  
 PROVISO:CARPORT HEIGHT SHALL NOT EXCEED 25' MEASURED
 FROM GRADE TO THE MIDPOINT OF THE ROOF'S PITCH.
  
  
  
  
 SENT TO "E" - SF RACK