| Plan Review Stops For Permit 08050357 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-08-11 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-11 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2008-08-11 14:40:31 | REVIEW LETTER OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-18 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-18 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2008-07-18 08:04:58 | **PROVISO** | | | | | | 1. BEFORE FIRST INSPECTION, SUBMIT REVIEW BY DESIGNER | | | OF RECORD FOR TENANT BUILDOUT (SMITH & MOORE). | | | | | | 2.AT RISK PERMIT (PENDING PROVISO). | | | | | | 3.A CO HOLD HAS BEEN PLACED ON THIS PERMIT PENDING | | | RECEIPT OF LETTER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-17 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-17 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2008-07-17 13:46:41 | ****CORRECTIONS**** | | | ****REVISED 6/23/8**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.AS THE BASE BUILDING HAS NOT OBTAINED A C.C. OR | | | C.O, PLEASE HAVE THE DESIGNER OF THE BASE BUILDING | | | (SMITH & MOORE) REVIEW THE PLANS.THIS CAN BE DONE | | | WITH A SHOP DRAWING REVIEW STAMP OR A LETTER. | | | | | | NOT ADDRESSED. PLEASE EITHER SUBMIT THE LETTER OR THE | | | PERMIT CAN BE ISSUED WITH THIS PROVISO, AT CONTRACTOR'S | | | RISK, BUT PLEASE ADVISE ME IF YOU WISH TO HAVE THIS | | | OPTION. | | | | | | 2-4.ADDRESSED. | | | | | | 5.SUITE 100 IS ALREADY IN USE BY ANOTHER TENANT | | | (ISSUED PERMIT).PLEASE REVISE SUITE NUMBER ON THE | | | PLANS AND ON THE APPLICATION. | | | | | | 2ND REVIEW, THIS MAY BE REVISED BY HAND.NO NEW SHEETS | | | ARE REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-03 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-03 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2008-06-03 09:46:54 | ****CORRECTIONS**** | | | ****REVISED 6/23/8**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.AS THE BASE BUILDING HAS NOT OBTAINED A C.C. OR | | | C.O, PLEASE HAVE THE DESIGNER OF THE BASE BUILDING | | | (SMITH & MOORE) REVIEW THE PLANS.THIS CAN BE DONE | | | WITH A SHOP DRAWING REVIEW STAMP OR A LETTER. | | | | | | 2.GOVERNING CODE, LS1.0, SHOULD INCLUDE 2007 | | | REVISIONS/SUPPLEMENTS. | | | | | | 3.ON THE LIFE SAFETY PLAN, PLEASE SHOW FIRE | | | RESISTANCE RATING TO THE EXITS ON THE EAST SIDE, | | | FBC1002.TRAVEL DISTANCE HAS BEEN MEASURED TO THE | | | DOORS TO THE SPACE, BUT IT IS NOT CLEAR WHERE THE EXIT | | | DISCHARGE FOR THE NORTH DOOR (FOR THE SPACE, APPARENTLY | | | LEADING TO THE EAST EXIT).TRAVEL DISTANCE HAS BEEN | | | SHOWN MEASURED TO THE DOOR TO THE SPACE, BUT FIRE | | | RESISTANCE RATING TO THE EXIT DISCHARGE HAS NOT BEEN | | | SHOWN. | | | | | | 4.PROVIDE A DETAIL FOR THE ACCESSIBLE SINK, FBC | | | 11-4.24.PLEASE PROVIDE ALL DIMENSIONS AS REQUESTED BY | | | THE PLUMBING REVIEWER. | | | | | | 5.SUITE 100 IS ALREADY IN USE BY ANOTHER TENANT | | | (ISSUED PERMIT).PLEASE REVISE SUITE NUMBER ON THE | | | PLANS AND ON THE APPLICATION. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-10-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-07 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-07 |
Time |
10:51 |
Sent To |
PC |
|
| Notes |
| 2008-10-07 11:08:17 | REVISED CIRCUITING |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-03 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-03 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2008-07-03 14:11:35 | WILL NEED TO REVISE BASE BUILDING PLANS, CALCULATIONS | | | AND ENREGY CALCULATIONS WITH ALL KNOWNS BEFORE FINAL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-03 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-03 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2008-06-03 18:50:27 | ** DENIED** | | | | | | | | | 1) NOTE:PLEASE SEE THE LIGHTING WHICH IS BEING SHOWN | | | ON ELECTRICAL LIGHTING PLANS NOTED WITH NOTE #4 SHALL | | | NOT HAVE PROVISIONS FOR FUTURE LIGHTS. BASED ON THE | | | METHOD OF CALCULATIONS SUBMITTED ALONG WITH THE MAXIMUM | | | ALLOWED WATTAGE AS SHOWN THESE LIGHT FIXTURES WOULD | | | PLACED THE ALLOWANCE WAY OVER THE TABLE ALLOWANCE AND | | | PERMITTED WATTAGE CONSUMPTION PER 13-415.2.ABC.1.1, | | | .1.2, 13-415.2.C. | | | PLEASE ADJUST PLANS AND PLEASE REMOVED FIXTURES. THE | | | DESIGN OF FIXTURES, NUMBER OF FIXTURES, WATTAGE OF | | | FIXTURES ETC MAY BE REVISED, HOWEVER MAT NOT BE DONE AS | | | SHOWN. | | | PLEASE ALSO KNOW THE *ALTERNATE LIGHTING* SHOWN ON E0.1 | | | IS NOT PART OF THE DESIGN AT THIS TIME. IF THIS IS | | | GOING TO BE USED THEN PLANS NEED TO BE REVISED | | | ACCORDINGLY. | | | | | | 2) NOTE: PLEASE VERIFY ACTUAL ROOM DESIGNATION FOR | | | IT/PHONE ROOM #123. IF THIS IS ACTUALLY AN IT ROOM THEN | | | PLEASE SHOW COMPLIANCE WITH 645 OF THE NEC. IF THIS NOT | | | AN IT ROOM PLEASE REMOVE THE IT DESIGNATION. | | | | | | 3) NOTE: PLEASE BE SURE ALL CIRCUITING ON PLANS | | | COORDINATES WITH THE SUBMITTED PANEL SCHEDULES. | | | PLEASE SUBMIT OTHER PANEL SCHEDULES FOR ITEMS LISTED ON | | | PLANS, BUT NO SCHEDULE SUBMITTED. | | | FOR EXAMPLE: | | | PLEASE SEE ROOM 125, CIRCUIT SHOWN TO PANEL HA-7 YET NO | | | HA PANEL WAS SUBMITTED. | | | | | | 408.4, 310.16, 240.4 ETC | | | FBC 106.3.5.1.2, 106.1.2 FOR ADDITIONAL INFORMATION AND | | | COORDINATION. | | | | | | 4) NOTE: REDLINED MDP AS DONE ON BASE BUILDING PLANS AS | | | THIS IS SHOWN WITH GFCI PROTECTION WHEN IN FACT THIS IS | | | GFP PER 240.13, 230.95. | | | | | | | | | 5) NOTE: ELECTRICAL RISER AS SHOWN ON E5.1 IS SHOWN AS | | | EXISTING AND IS NOT REVIEWED FOR CODE COMPLIANCE. | | | BASE BUILDING IS YET TO RECEIVE CO. | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-11 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-11 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2008-07-11 14:24:35 | STAMPED SHEETS LS0.1, FA0.1 AND FA2.1 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-04 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-04 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2008-06-04 10:24:33 | ***DENIED*** | | | | | | 1) SINCE THE FIRE SPRINKLER SYSTEM WILL BE ALTERED, | | | PLEASE ADD NFPA 13, 2002 EDITION TO BUILDING CODE | | | CLASSIFICATION. | | | | | | 2) UL LISTED CLOSERS ARE REQUIRED ON FIRE RATED DOORS. | | | PLEASE ADD TO DOOR SCHEDULE. | | | | | | 3) PROVIDE MINIMUM INTERIOR FINISH CLASSIFICATION FOR | | | WALLS AND CEILINGS USING CLASS A,B OR C. | | | | | | 4) SHEET LS1.0 ILLUSTRATES AN EXIT SIGN AT OPEN OFFICE | | | 117 THAT IS NOT SHOWN ON SHEET E2.1. PLEASE CORRELATE | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-10-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-01 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-01 |
Time |
10:01 |
Sent To |
M |
|
| Notes |
| 2008-10-01 10:01:40 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-10-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-01 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-01 |
Time |
10:00 |
Sent To |
M |
|
| Notes |
| 2008-10-01 10:00:53 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-29 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-29 |
Time |
16:58 |
Sent To |
M |
|
| Notes |
| 2008-09-29 16:58:31 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-29 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-29 |
Time |
16:55 |
Sent To |
E |
|
| Notes |
| 2008-09-29 16:55:56 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-08-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-22 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-22 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2008-08-22 13:01:39 | TO RJR DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-31 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-31 |
Time |
10:51 |
Sent To |
B |
|
| Notes |
| 2008-07-31 10:52:07 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-16 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-16 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2008-06-16 10:49:01 | TO "COMM" BD#5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-04 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-05-14 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2008-05-14 15:02:52 | TO "COMM" BD#20 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-10-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-10-10 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-10-10 |
Time |
11:11 |
Sent To |
PC |
|
| Notes |
| 2008-10-11 11:07:19 | PAGE M2.2 REV.3; PAGES M0.1 AND M2.1 REV.4. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-08-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-22 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-22 |
Time |
13:08 |
Sent To |
PC |
|
| Notes |
| 2008-08-22 13:13:58 | REVISED PAGE M2.2 DENIED. | | | | | | ORIGINAL PERMIT SET OF PLANS WERE SIGNED ANDD SEALED BY | | | ROBERT KAMM. THE PRINTED LICENSE # AND NAME OF ROBERT | | | KAMM STILL APPEARS IN THE TITLE BLOCK ON THE REVISED | | | PLANS, BUT THEY WERE NOT SIGNED OR SEALED BY ROBERT | | | KAMM. | | | | | | PLEASE RESUBMIT REVISED PLANS SIGNED AND SEALED BY THE | | | DESIGNER OF RECORD OR FOLLOW THE PROCEDURES FOR | | | CHANGING THE DESIGNER OF RECORD IN ACCORDANCE WITH FAC | | | RULE 6IG15. ALSO, THE PRINTED NAME AND LICENSE NUMBER | | | OF THE PERSON SIGNING AND SEALING THE PLANS SHALL | | | APPEAR IN THE TITLE BLOCK IN ACCORDANCE WITH THE SAME | | | RULE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-03 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-03 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2008-07-03 13:22:50 | PREVIOUS REVIEW PASSED. ALL NEW SHEETS FOR THIS REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-02 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-02 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-14 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-14 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-06-02 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-06-02 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2008-06-02 09:39:29 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 11 | | | | | | 1. SHT A3.0, DETAIL 10. SHOW COMPLIANCE WITH THE | | | FOLLOWING FOR THE SINK. | | | A. 11-4.24.3 KNEE CLEARANCE | | | B. 11-4.24.4 SINK DEPTH | | | C. 11-4.24.5 CLEAR FLOOR SPACE | | | D. 11-4.24.6 EXPOSED PIPES & SURFACES | | | E. 11-4.24.7 FAUCETS | | | | | | 2. SHT P0.1 THE WATER RISER DIAGRAM DOES NOT RELFECT | | | THE FLOOR PLAN. SEE SHT A3.0 DETAIL 10 AS IT SHOWS A | | | REFRIGERATOR ON THE RIGHT SIDE OF THE SINK AND AN ICE | | | MAKER ON THE LEFT SIDE OF THE SINK. PLEASE SHOW BOTH ON | | | THE RISER DIAGRAM. ALSO THE RISER IS SHOWING THE COLD | | | SUPPLY ON THE LEFT SIDE OF THE SINK AND THE HOT SUPPLY | | | ON THE RIGHT SIDE OF THE SINK. SECTIONS 106.1.1 & | | | 607.4.--THE HOT WATER TO THE DISHWASHER REQUIRES A | | | WATER HAMMER ARRESTOR PER SECTION 604.9. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|