Plan Review Details - Permit 08050346
Plan Review Stops For Permit 08050346
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-06-24 Cont ID  
Sent By shill Date 2008-06-24 Time 10:04 Rev Time 0.00
Received By shill Date 2008-06-24 Time 09:56 Sent To  
Notes
2008-06-24 10:05:07****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1. SEE SHEET 1.CONSTRUCTION IS NOT CLEAR.PLANS SHOW
 2X6 WITH 2X2 ?CROSS BEAMS?, THEN STATES THAT THE
 LATTICE WILL BE STAPLED EVERY 2IN ALONG EVERY TRUSS AND
 CROSS BEAM.IF THE ?CROSS BEAM? SITS ON TOP OF THE
 FRAMING, THAT IS NOT POSSIBLE.DO YOU MEAN 2X2
 PURLINS?THIS IS SHOWN GRAPHICALLY AS EITHER SITTING
 ON TOP OR THE 2X6S CUT TO FIT IN BETWEEN.THE GRAPHIC
 DOES NOT APPEAR TO MATCH THE SPECIFICATION, PLEASE
 CLARIFY DETAIL.
  
 2. ADDRESSED.
  
 3. VALUE HAS BEEN ADJUSTED AS PER MARSHALL & SWIFT,
 ADDITIONAL FEES DUE. SEE ATTACHED BILL $55.99.
  
 4. ADDRESSED.
  
 5.DECLARE GOVERNING CODE, INCLUDING 2007
 REVISIONS/SUPPLEMENTS.
  
 2ND REVIEW, NOT ADDRESSED.PLEASE REVISE PLAN TO
 INCLUDE GOVERNING CODE WHICH SHOULD STATE:FBC2004
 WITH 2007 REVISIONS/SUPPLEMENTS.
  
 6.SHOW COMPLIANCE WITH FBC*109.3.4, TERMITE
 PROTECTION.
  
 7.SEE FBC106.3.5.4(6), STRUCTURAL REQUIREMENTS,
 CONNECTORS NOT SHOWN AT ALL CONNECTIONS.USUALLY A
 GRAPHIC IS PLACED ON THE PLAN INDICATING THAT ALL
 FRAMING WILL HAVE THE CONNECTOR SPECIFIED; THE PLAN
 POINTS TO ONLY ONE PER CONNECTOR.PLEASE REVISE.
  
 8.DECLARE WIND DESIGN CRITERIA, FBC R301.THIS
 SHOULD INCLUDE WIND SPEED AND EXPOSURE CLASSIFICATION,
 IMPORTANCE FACTOR.
  
 2ND REVIEW, NOT ADDRESSED.PLEASE REVISE PLAN TO
 INCLUDE THIS REQUIRED INFORMATION, WHICH IS MOST LIKELY
 140MPH, EXPOSURE B.
  
 9-13. ADDRESSED.
  
 14.SHOW GRADE IN RELATION TO THE FINISHED FLOOR, FBC
 R312.SHEET 2 STATES THAT THIS WILL BE 36IN, BUT THIS
 INFORMATION SHOULD BE INCORPORATED INTO THE PLAN.
  
 2ND REVIEW, SHEET 4 SHOWS THIS AS 36IN, BUT SHEET 7
 SHOWS THIS DIMENSION AS 34IN.PLEASE REVISE AND CHECK
 ALL (36IN REQUIRED), FBC R 312.1.
  
 15.SHEET 8, STAIR DETAIL, FRONT VIEW OF RAILS SHOWS A
 32IN HEIGHT, SIDE VIEW SHOWS 36IN.PLEASE REVISE
 DIMENSION FOR FRONT VIEW, FBC R301.
  
 16-19. ADDRESSED.
  
 20. REGARDING THE STAIR DETAIL PROVIDED ON SHEET 8:
  
 A. SEE FBCR311.5.3.2, THE SUM OF TWO RISERS AND A TREAD
 SHALL NOT BE LESS THAN 24IN NOR MORE THAN 25IN.NOTE
 THAT YOU MUST TAKE ACTUAL DIMENSIONS, NOT THE NOMINAL
 DIMENSIONS.
  
 B. CLARIFY RISER HEIGHT.A RISER IS SHOWN AS 5/8X6,
 BUT IF A 2X IS PLACED ON TOP, THE RISER HEIGHT IS NOT
 6IN.PROVIDE A DETAIL WHICH IS GRAPHICALLY CORRECT AND
 WHICH SHOWS ALL DIMENSIONS, INCLUDING RISER HEIGHT.
 COMPLIANCE WITH ITEM 20A CANNOT BE DETERMINED.
  
 21-23. ADDRESSED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-30 Cont ID  
Sent By shill Date 2008-05-30 Time 09:29 Rev Time 0.00
Received By shill Date 2008-05-30 Time 09:29 Sent To  
Notes
2008-05-30 09:33:25****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.PLEASE NOTE THAT NOT ENOUGH STRUCTURAL INFORMATION
 WAS PROVIDED TO COMPLETE A THOROUGH REVIEW.
  
 2.PROVIDE A CLEAN SITE PLAN, WITHOUT THE CITY STAMPS,
 SHOWING THE PROPOSED IMPROVEMENT IN RELATION TO THE
 PROPERTY LINE AND THE EXISTING STRUCTURE.ALL
 DIMENSIONS SHOULD BE SHOWN.FBC*106.3.5.4(1).
  
 3. PROVIDE A REASONABLE VALUE FOR THIS JOB.
  
 4. ARCHITECTURAL QUALITY PLANS ARE REQUIRED,
 FBC*106.1.1.
  
 5.DECLARE GOVERNING CODE, INCLUDING 2007
 REVISIONS/SUPPLEMENTS.
  
 6.SHOW COMPLIANCE WITH FBC*109.3.4, TERMITE
 PROTECTION.
  
 7.SEE FBC106.3.5.4(6), STRUCTURAL REQUIREMENTS,
 INCLUDING WALL SECTION FROM FOUNDATION THROUGH ROOF,
 INCLUDING ASSEMBLY AND MATERIALS CONNECTOR TABLES WIND
 REQUIREMENTS STRUCTURAL CALCULATIONS (IF REQUIRED).
  
 AS NOTED, CALCULATIONS MAY BE REQUIRED.NONE REQUIRED
 AT THIS TIME.
  
 8.DECLARE WIND DESIGN CRITERIA, FBC R301.THIS
 SHOULD INCLUDE WIND SPEED AND EXPOSURE CLASSIFICATION,
 IMPORTANCE FACTOR.
  
 9.DECLARE DESIGN CRITERIA, FBC R301.1.THIS SHOULD
 INCLUDE DEAD LOADS AND LIVE LOADS.
  
 10.THE SITE PLAN SHOWS A WOOD DECK ADJACENT TO THE
 EXISTING HOUSE.DOES THE EXISTING STRUCTURE SUPPORT
 ONE SIDE OF THE PROPOSED DECK AND TRELLIS?IF THIS IS
 THE CASE, ADDRESS THE EFFECT ON THE EXISTING STRUCTURE.
 PROVIDE A STRUCTURAL DETAIL FOR CONNECTION.
  
 11.TO ASSIST IN PLAN REVIEW, EACH PLAN SHEET SHOULD
 BE IDENTIFIED.OTHERWISE, I HAVE NO WAY TO PROPERLY
 CONVEY CODE COMMENTS AS RELATED SPECIFICALLY TO YOUR
 PLAN.I HAVE NUMBERED THE SHEETS 1 THROUGH 3, SEE
 ATTACHED.
  
 12.INFORMATIONAL; TWO COMPLETE, IDENTICAL COLLATED
 SETS OF PLANS REQUIRED FOR PERMIT ISSUANCE.
  
 13.THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN IS TO BE ON THE PLAN, FBC106.
  
 14.SHOW GRADE IN RELATION TO THE FINISHED FLOOR, FBC
 R312.SHEET 2 STATES THAT THIS WILL BE 36IN, BUT THIS
 INFORMATION SHOULD BE INCORPORATED INTO THE PLAN.
  
 15.SPECIFY STRENGTH DESIGN CRITERIA FOR THE
 GUARDRAILS, FBC R312.PROVIDE A COMPLETE STRUCTURAL
 DETAIL; NOTE THAT THE DETAIL ON SHEET 3 DOES NOT
 INCLUDE MATERIAL OR HEIGHT OR METHOD OF ATTACHMENT.
 CALCULATIONS MAY BE REQUIRED.
  
 16. FBC R305, SPECIFY CEILING HEIGHT; STATE CLEARANCE
 BETWEEN THE TOP OF FINISHED FLOOR TO THE BOTTOM OF THE
 BEAM.
  
 17. SHEET 1 STATES THAT FOOTING POSTS ARE 4IN IN
 CONCRETE.DO YOU MEAN 4 FEET? THIS INFORMATION SHOULD
 BE INCLUDED DRAWN, TO SCALE, AS A PART OF THE WALL
 SECTION.
  
 18.THE PLAN WAS SUBMITTED AS A PERSPECTIVE, BUT
 SHOULD BE SUBMITTED AS PLAN AND ELEVATIONS. PERSPECTIVE
 IS OPTIONAL BUT CANNOT REPLACE PLAN AND ELEVATION
 VIEWS.
  
 19. SPECIFY TYPE OF MATERIAL.DIMENSIONS WERE PROVIDED
 BUT NO REFERENCE TO MATERIAL SUCH AS LUMBER SPECIES OR
 PT, OR SYNTHETIC.SPANS ALLOWED CANNOT BE DETERMINED
 WITHOUT THIS INFORMATION, FBC R TABLE 502.2.2(1), FBC
 R802.
  
 20.PROVIDE A STRUCTURAL DETAIL FOR THE STAIRS WITH
 ALL DIMENSIONS.NO INFORMATION WAS PROVIDED OTHER THAN
 A LINE DRAWING PERSPECTIVE.
  
 21.IT APPEARS THAT A HANDRAIL/GUARDRAIL MAY BE
 REQUIRED AT THE STAIR.IF THIS IS REQUIRED, PLEASE
 PROVIDE A STRUCTURAL DETAIL.FBC R 311.5.6, 312.
  
 22.SHEET 1 SPECIFIES LAG BOLTS; NO SIZE (DIAMETER) OR
 LENGTH SPECIFIED.SUBSTRATE INFORMATION NOT PROVIDED.
  
 23.SHEET 1 STATES 'STRAPS PER CODE".ALL STRUCTURAL
 INFORMATION MUST BE PROVIDED IN THE PLAN."TO CODE"
 CANNOT BE USED AS A SPECIFICATION.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-16 Cont ID  
Sent By adarroug Date 2008-06-16 Time 11:13 Rev Time 0.00
Received By adarroug Date 2008-06-16 Time 11:13 Sent To Z
Notes
2008-06-16 11:15:06TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-30 Cont ID  
Sent By shill Date 2008-05-30 Time 09:33 Rev Time 0.00
Received By shill Date 2008-05-14 Time 08:30 Sent To  
Notes
2008-05-14 08:31:40TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status F Date 2008-06-16 Cont ID  
Sent By choops Date 2008-06-16 Time 15:49 Rev Time 0.00
Received By choops Date 2008-06-16 Time 15:49 Sent To B
Notes
2008-06-16 15:51:27***FAILED - RESUB #1***
  
  
 REPEAT COMMENT:
  
 1)INDICATE THE SETBACK DIMENSIONS FROM THE PROPOSED
 DECK/TRELLIS TO ALL ADJACENT PROPERTY LINES.
  
 NOTE:MINIMUM SETBACK REQUIREMENTS:
 FRONT = 25'
 SIDE = 5' MINIMUM, TOTAL OF 15' BETWEEN THE TWO SIDES
 REAR = 15' OR 10% OF THE LOT DEPTH, WHICHEVER IS LESS
  
  
 NEW COMMENT:
  
 1)ANY/ALL RESUBMITTED PLANS SHALL BE
 RESTAMPED/APPROVED BY THE CITY'S HISTORIC PRESERVATION
 DEPARTMENT.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "B" - SH

Review Stop Z ZONING
Rev No 1 Status F Date 2008-05-16 Cont ID  
Sent By choops Date 2008-05-16 Time 13:05 Rev Time 0.00
Received By choops Date 2008-05-16 Time 13:05 Sent To B
Notes
2008-05-16 13:17:12***FAILED***
  
  
 1)PROVIDE TWO (2) COPIES OF A CLEAN SURVEY, WHICH
 INDICATES THE PROPOSED SCOPE OF WORK.INDICATE THE
 PROPOSED DECK/TRELLIS WITH DIMENSIONS AND SETBACK
 DIMENSIONS TO ALL ADJACENT PROPERTY LINES.
  
 2)DRAWINGS OF DECK/TRELLIS SHALL INDICATE HEIGHT OF
 PROPOSED DECK FROM GRADE, AND SHALL INDICATE HEIGHT OF
 PROPOSED TRELLIS FROM GRADE.
  
 3)CLARIFY WHERE THE SHOWN RAILING IS TO BE
 INSTALLED.
  
  
 NOTE:THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "B" - MISC. 2
  