Plan Review Details - Permit 08050224
Plan Review Stops For Permit 08050224
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-11-04 Cont ID  
Sent By amorse Date 2008-11-04 Time 16:05 Rev Time 1.00
Received By amorse Date 2008-11-04 Time 16:05 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-11-01 Cont ID  
Sent By amorse Date 2008-11-01 Time 07:26 Rev Time 0.75
Received By amorse Date 2008-11-01 Time 07:26 Sent To PC
Notes
2008-11-01 07:40:20 
  
 DENIED
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM THE 1ST
 REVIEW
  
 C) IN THE PANEL MOUNTING TYPE COLUMN YOU SHOULD ENTER
 THE MOUNTING METHOD USED (PAGES 3,4 & 5) NOT THE PARTS
 FROM PAGE 1A, PLEASE NOTE THAT THESE MOUNTING METHODS
 ARE IN THE LAST COLUMNS OF THE O/C SPACING TABLES
 ********PLEASE NOTE THAT PARTS 3, 7 AND 10 ARE ALL PART
 OF MOUNTING METHOD FOR SECTION 2, THEREFORE 2 WOULD BE
 USED FOR THE TOP OR BOTTOM IN THE SCEDULE. LIKEWISE IF
 YOU WERE TO USE PART 10 ON THE BOTTOM SECTION 1 WOULD
 APPLY. THE SHEDULE MUST BE ACCURATE AND LEGIBLE BECAUSE
 ONCE CHECKED BY PLAN REVIEW IT WILL BE USED BY THE
 INSPECTOR ON SITE.********
  
 D) THE SAME IDEA APPLIES TO THE ACCORDION SHUTTERS FOR
 MOUNTING TYPE (SEE PAGE 5) IF 2 AND 4 ARE CHOSEN ONLY
 COLUMNS 2 AND 4 ON SHEET 10 WOULD APPLY, THEREFORE THE
 O/C SPACING FOR SHUTTERS 11 AND 12 WHICH ARE OVER 7'-0"
 SPAN WOULD BE 7.5"
 ********THE PRODUCT APPROVALS FOR THE ACCORDIAN
 SHUTTERS WAS NOT RETURNED WITH THE PERMIT
 APPLICATION*********
  
 2) SUBMIT 2 COPIES OF CORRECTED SHUTTER SCHEDULE
 ********ONLY ONE COPY OF THE SHUTTER SCHEDULE WAS
 SUBMITTED WITH THE PERMIT APPLICATION, PLEASE MAKE ALL
 CORRECTIONS AND SUBMIT 2 COPIES********
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-15 Cont ID  
Sent By amorse Date 2008-05-15 Time 14:30 Rev Time 0.00
Received By amorse Date 2008-05-15 Time 14:30 Sent To PC
Notes
2008-05-15 15:11:01 
  
 DENIED
  
 1) PLEASE MAKE THE FOLLOWING CORRECTIONS TO THE SHUTTER
 SCHEDULE
  
 A) THE EDGE DISTANCE FOR BOTH THE ACCORDIONS AND THE
 PANELS IS 3 1/2" FOR THE MAXIMUM ON CENTER SPACING
 SHOWN, IF E.D. IS SMALLER PLEASE NOTE THE TABLES ON
 PAGES 6 & 7 OF THE PANEL DRAWINGS AND PAGE 11 OF THE
 ACCORDIONS. SMALLER EDGE DISTANCE REQUIRES THE O/C
 SPACING TO BE MULTIPLIED BY THE FACTOR IN THESE TABLES
 WHICH IN TURN WILL ADJUST THE SPACING DISTANCE. UNDER
 NO CIRCUMSTANCE CAN 1" BE USED AS STATED IN YOUR
 SCHEDULE, THE MINIMUM EDGE DISTANCE IS 2".
  
 B) PANEL LENGTHS ON AVERAGE ARE OPENING WIDTH OR HEIGHT
 PLUS EDGE DISTANCE X 2, (7") PLUS APPROX 2" FOR PANEL
 PAST THE MOUNTING SCREW
  
 C) IN THE PANEL MOUNTING TYPE COLUMN YOU SHOULD ENTER
 THE MOUNTING METHOD USED (PAGES 3,4 & 5) NOT THE PARTS
 FROM PAGE 1A, PLEASE NOTE THAT THESE MOUNTING METHODS
 ARE IN THE LAST COLUMNS OF THE O/C SPACING TABLES
  
 D) THE SAME IDEA APPLIES TO THE ACCORDION SHUTTERS FOR
 MOUNTING TYPE (SEE PAGE 5) IF 2 AND 4 ARE CHOSEN ONLY
 COLUMNS 2 AND 4 ON SHEET 10 WOULD APPLY, THEREFORE THE
 O/C SPACING FOR SHUTTERS 11 AND 12 WHICH ARE OVER 7'-0"
 SPAN WOULD BE 7.5"
  
 E) SHUTTER PANEL FOR OPENING # 2 WHEN PANEL LENGTH IS
 CORRECTED PER FORMULA IN NOTE "A" EXCEEDS THE MAXIMUM
 PANEL LENGTH ALLOWED PER TABLE ON SHEET 5 IF H HEADER
 IS USED, BUT WOULD BE ALRIGHT IF DIRECT MOUNTED TO
 WALL
  
 F) PLEASE SEE NOTE ON PAGE 5 OF PANEL DRAWINGS, 3'-0"
 IS MINIMUM PANEL LENGTH THEREFORE OPENING # 14 PANELS
 ARE REQUIRED TO BE LENGTHENED OR INSTALLED
 HORIZONTALLY
  
 2) SUBMIT 2 COPIES OF CORRECTED SHUTTER SCHEDULE
  
 3) MAKE CORRECTIONS TO DRAWINGS THAT REFLECT THE WORK
 TO BE PERFORMED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-10-30 Cont ID  
Sent By adarroug Date 2008-10-30 Time 14:24 Rev Time 0.00
Received By adarroug Date 2008-10-30 Time 14:24 Sent To B
Notes
2008-10-30 14:31:17TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2008-05-15 Time   Rev Time 0.00
Received By adarroug Date 2008-05-08 Time 12:50 Sent To  
Notes
2008-05-08 12:50:55TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved