Plan Review Details - Permit 08050162
Plan Review Stops For Permit 08050162
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-01 Cont ID  
Sent By mjacobs Date 2008-10-01 Time 11:44 Rev Time 0.00
Received By mjacobs Date 2008-10-01 Time 11:43 Sent To  
Notes
2008-10-01 11:44:52REVISION TO SHEET A-1 ADDITIONAL CLOSET TO BEDROOM 2

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-07-03 Cont ID  
Sent By mjacobs Date 2008-07-03 Time 07:58 Rev Time 0.00
Received By mjacobs Date 2008-07-01 Time 09:43 Sent To FIRE
Notes
2008-07-03 07:59:21PLANS NEED MTO BE RESTAMP BY FIRE REVIEWER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-19 Cont ID  
Sent By mjacobs Date 2008-05-19 Time 10:55 Rev Time 0.00
Received By mjacobs Date 2008-05-19 Time 07:53 Sent To  
Notes
2008-05-19 10:55:51BUILDING PLAN REVIEW 1ST
 PERMIT: 08050162
 ADD: 1617 N. FLAGLER DR. #903
 CONT: JEFFERY W. LEWIS INC.
 TEL: (561)691-1801
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 5-19-08
 REVIEW: 1ST
 ACTION: DENIED
  
 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 2) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT,
 TO BE FILED WITH THE CLERK OF THE COURT. NOTE:
 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 3)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE 2007 SUPPLEMENTS.
  
 4)PER FLORIDA STATUTES, 481.229 EXEMPTIONS FROM
 ARCHITECTURAL LICENSURE ONLY APPLY TO 1FAMILY AND
 2FAMILY RESIDENCES (R3) NOT MULTI-FAMILY (R2) OR
 BUILDINGS OVER $25,000, THEREFORE, DRAWINGS ARE
 REQUIRED TO BE DRAWN BY A LICENSED DESIGN
 PROFESSIONAL.
  
 A DESIGN PROFESSIONAL THAT IS REGISTERED TO PRACTICE
 UNDER CHAPTER 481 OR 471 OF THE FLORIDA STATUTES SHALL
 AFFIX THEIR OFFICIAL SEAL, SIGNATURE AND DATE TO SAID
 DRAWINGS AND SPECIFICATION PER 106.1 FBC 2004, THE
 EXEMPTION FROM LICENSURE UNDER 481.229 FLORIDA STATUTES
 DOES NOT EXEMPT THE DESIGNER RESPONSIBLE FOR THE
 DRAWINGS FROM SIGNING AND DATING SAID DRAWINGS.
  
 5) THE PLANS FAIL TO INDICATE THE DIMENSIONS OF THE
 ALTERED AREA. IT SEEMS AS IF THERE ARE SOME SOFFIT WORK
 IN THE AREA, HOWEVER THERE IS NO CEILING PLANS OR
 DETAILS TO SHOW CLEARLY WHERE THE SOFFITS WILL BE
 CONSTRUCTED.CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. FBC
 106.1.1
  
 6)TABLE 803.5 MINIMUM INTERIOR FINISH CLASSIFICATION;
 PROVIDE INFORMATION BASED ON INTERIOR FINISH
 REQUIREMENTS BASED ON OCCUPANCY.
  
 7)2004 FBC EXISTING
 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 8)THE PLANS SHALL INDICATE THE HEIGHT, TYPE OF
 BUILDING PER CHAPTER 6 AND TABLE 601, THE USE AND
 OCCUPANCY CLASSIFICATION PER CHAPTER 3.
  
 9)INDICATE THE USE OF EACH ROOM ON THE DRAWINGS. ON
 SHEET A-3 THERE ARE THREE DIFFERENT WALL DETAILS,
 PROVIDE A LEGEND SHOWING/INDICATING WHERE EACH DETAIL
 WILL BE USED ON THE FLOOR PLANS.CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THE CODE. FBC 106.1.1
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-06-19 Cont ID  
Sent By btrobaug Date 2008-06-19 Time 11:49 Rev Time 0.00
Received By btrobaug Date 2008-06-19 Time 11:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-05-13 Cont ID  
Sent By btrobaug Date 2008-05-13 Time 09:56 Rev Time 0.00
Received By btrobaug Date 2008-05-13 Time 09:10 Sent To  
Notes
2008-05-13 09:56:10FBC.
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005
 NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC CHAPTER 1AS
 AMENDED,THE 2007 FLORIDA STATUTES, AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1}THE 2007 FLORIDA STATUTES
  
 TITLE XXXII
 REGULATION OF PROFESSIONS AND OCCUPATIONS CHAPTER 481
 ARCHITECTURE, INTERIOR DESIGN, AND LANDSCAPE
 ARCHITECTURE
 481.229EXCEPTIONS; EXEMPTIONS FROM LICENSURE.--
  
 (1)NO PERSON SHALL BE REQUIRED TO QUALIFY AS AN
 ARCHITECT IN ORDER TO MAKE PLANS AND SPECIFICATIONS
 FOR, OR SUPERVISE THE ERECTION, ENLARGEMENT, OR
 ALTERATION OF:
  
 (A)ANY BUILDING UPON ANY FARM FOR THE USE OF ANY
 FARMER, REGARDLESS OF THE COST OF THE BUILDING;
  
 (B)ANY ONE-FAMILY OR TWO-FAMILY RESIDENCE BUILDING,
 TOWNHOUSE, OR DOMESTIC OUTBUILDING APPURTENANT TO ANY
 ONE-FAMILY OR TWO-FAMILY RESIDENCE, REGARDLESS OF COST;
 OR
  
 (C)ANY OTHER TYPE OF BUILDING COSTING LESS THAN
 $25,000, EXCEPT A SCHOOL, AUDITORIUM, OR OTHER BUILDING
 INTENDED FOR PUBLIC USE, PROVIDED THAT THE SERVICES OF
 A REGISTERED ARCHITECT SHALL NOT BE REQUIRED FOR MINOR
 SCHOOL PROJECTS PURSUANT TO S. 1013.45* THE EXCEPTION
 IS NOT MET THEREFORE A DESIGN PROFESSIONAL IS REQUIRED
 TO.TAKE RESPONSIBILITY FOR THE PLANS.
  
 2} 301.5 FBC EXISTING BUILDING CODE. THE DESIGN
 PROFESSIONAL OR OWNER MUST ELECT THE LEVEL OF
 ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF THE
 EXISTING BUILDING CODE. PLEASE DECLARE SAME ON THE
 PLAN.
  
 3} INDICATE THE TYPE OF FIRE ALARM/DETECTION SYSTEM
 WILL BE INSTALLED IN THE UNIT. SEE NFPA-72 CHAPTER 11,
 AND CHAPTER 9 FBC.
  
 4} PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE
 BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE
 CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE PUT A ON
 THE PLAN FOR CLARITY IN THE FIELD.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2008-10-07 Cont ID  
Sent By mwennerg Date 2008-10-07 Time 15:30 Rev Time 0.00
Received By mwennerg Date 2008-10-07 Time 15:30 Sent To  
Notes
2008-10-07 15:31:47REVISION #2 DATED 9/22/08.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-07-03 Cont ID  
Sent By mwennerg Date 2008-07-03 Time 10:42 Rev Time 0.00
Received By mwennerg Date 2008-07-03 Time 10:42 Sent To  
Notes
2008-07-03 10:42:58PLANS RE-STAMPED ONLY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-06-30 Cont ID  
Sent By mwennerg Date 2008-06-30 Time 10:56 Rev Time 0.00
Received By mwennerg Date 2008-06-30 Time 10:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-05-20 Cont ID  
Sent By mwennerg Date 2008-05-20 Time 11:13 Rev Time 0.00
Received By mwennerg Date 2008-05-20 Time 11:13 Sent To  
Notes
2008-05-20 11:18:42***DENIED***
  
 1) LIFE SAFETY TO COMPLY WITH NFPA 101, 2003 EDITION.
  
 2) SEE OTHER REVIEW COMMENTS REGARDING FLORIDA STATUTES
 REQUIREMENTS FOR PLANS.
  
 3) WILL WORK IMPACT EXISTING FIRE SPRINKLER EQUIPMENT?
  
 4) PLEASE INDICATE LOCATION OF SMOKE ALARMS.
  
 5) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY
 WITH NFPA 241.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-09-29 Cont ID  
Sent By adarroug Date 2008-09-29 Time 12:38 Rev Time 0.00
Received By adarroug Date 2008-09-29 Time 12:38 Sent To  
Notes
2008-09-29 12:40:25TO "BOB"#7

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-18 Cont ID  
Sent By adarroug Date 2008-06-18 Time 11:42 Rev Time 0.00
Received By adarroug Date 2008-06-18 Time 11:42 Sent To  
Notes
2008-06-18 11:43:52TO "BOB"#4

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-21 Cont ID  
Sent By tgordon Date 2008-05-21 Time 09:13 Rev Time 0.00
Received By tgordon Date 2008-05-07 Time 14:49 Sent To  
Notes
2008-05-07 14:52:49TO "BOB"#4

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-05-21 Cont ID  
Sent By tgordon Date 2008-05-21 Time 09:12 Rev Time 0.20
Received By tgordon Date 2008-05-21 Time 09:12 Sent To  
Notes
2008-05-21 09:13:09NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop Z ZONING
Rev No 1 Status N Date 2008-05-09 Cont ID  
Sent By choops Date 2008-05-09 Time 11:08 Rev Time 0.00
Received By choops Date 2008-05-09 Time 11:08 Sent To  
Notes
2008-05-09 11:08:32*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.