Plan Review Details - Permit 08050042
Plan Review Stops For Permit 08050042
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-15 Cont ID  
Sent By shill Date 2008-10-15 Time 16:11 Rev Time 0.00
Received By shill Date 2008-10-15 Time 16:11 Sent To  
Notes
2008-10-15 16:14:02RFIS; INSPECTOR REQUEST, REVIEWED BY G.SMITH AND
 K.CONRAD
 TRAILER PARKING SLAB REINFORCEMENT
 WIRE MESH SUBMITTAL, SLAB BRICK SUBMITTAL
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-07-15 Cont ID  
Sent By shill Date 2008-07-15 Time 13:19 Rev Time 0.00
Received By shill Date 2008-07-15 Time 13:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-28 Cont ID  
Sent By shill Date 2008-05-28 Time 16:41 Rev Time 0.00
Received By shill Date 2008-05-28 Time 16:41 Sent To  
Notes
2008-05-28 16:41:56****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.SEE FAC61G15-23.002; PRINTED NAME OF THE PERSON
 SEALING THE DOCUMENT AND THE CERTIFICATE OF
 AUTHORIZATION FOR THE ENGINEERING FIRM ARE TO BE
 PRINTED ON EACH SHEET.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-08-25 Cont ID  
Sent By dpalmer Date 2008-08-25 Time 10:11 Rev Time 0.00
Received By dpalmer Date 2008-08-25 Time 10:10 Sent To  
Notes
2008-08-25 10:11:20REVISED SITE CONDUITS

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-07-07 Cont ID  
Sent By dpalmer Date 2008-07-07 Time 08:36 Rev Time 0.00
Received By dpalmer Date 2008-07-03 Time 16:58 Sent To  
Notes
2008-07-07 08:36:56 
  
 ** REDLINED PLANS **
  
 1) NOTE:SHEETS DENOTED AS SE ARE STAMPED AND REDLINED
 FOR SITE ELECTRICAL UNDERGROUND CONDUITS ONLY. THIS IS
 NOT A REVIEW FOR ANY ELECTRICAL SYSTEMS/LIGHT
 FIXTURES/GROUNDING/SERVICE/LIGHTNING PROTECTION ETC.
 ** THIS IS ONLY FOR SITE UNDERGROUND/CONDUITS.
 ** SHEETS E101C, E106C, E109C AND E117C HAVE BEEN
 MARKED AS VOID. THESE ARE NOT PART OF REVIEW OR SCOPE
 OF WORK.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-05-22 Cont ID  
Sent By dpalmer Date 2008-05-22 Time 09:28 Rev Time 0.00
Received By dpalmer Date 2008-05-22 Time 09:28 Sent To  
Notes
2008-05-22 09:28:55** DENIEDREVIEW**
  
  
  
 1) NOTE:PLEASE SEE THE TITLE BLOCKS ON ALL SHEETS AS
 WELL AS ANY OTHER TITLE BLOCKS ON OTHER PLANS WHICH ARE
 MISSING THE REQUIRED INFORMATION PER FLORIDA
 ADMINISTRATIVE CODE 61G15-23.002.
 PLEASE SEE MISSING PRINTED NAME, PRINTED LICENSE NUMBER
 OF THE DESIGNER.
 PLEASE SEE MISSING CERTIFICATE OF AUTHORIZATION NUMBER
 FOR FIRMS SUCH ASWHITNEY, BAILEY, COX AND MAGNANI
 LLC* ETC.
 PLEASE SEE FLORIDA STATUTES 471.023 FOR ENGINEERING
 FIRMS WHICH ARE REQUIRED TO BE LICENSE IN THE STATE OF
 FLORIDA.
 ** THIS COMMENT IS FOR ALL TRADES AND FOR ALL
 REVIEWER(S) WHETHER OR NOT COMMENT IS MADE BY THOSE
 OTHER TRADE REVIEWER(S).
 PLEASE KNOW EVEN AS SOME SHEETS WERE STAMPED BY TRADES
 SUCH AS ZONING AND ENGINEERING THESE SHEETS SHALL
 BECOME VOID IF INFORMATION IS NOT COMPLETED.
 IF THERE ARE ANY QUESTIONS ON THIS PLEASE DO NOT
 HESITATE IN CONTACTING THIS OFFICE
  
 2) NOTE: PLEASE SUBMIT ONLY PLANS RELEVANT TO THE
 APPLIED FOUNDATION ELECTRICAL SCOPE OF WORK. PLANS DO
 NOT SHOW ANY GROUNDING ELECTRODE SYSTEM AS REQUIRED PER
 250.50. PLEASE SEE THAT PLANS DO NOT SHOW ANY
 FOUNDATION PIPING FOR SERVICE, ETC.
 PLEASE SUBMIT.
 FBC 106.1.2, 106.1, 106.3.5.1.2. ADMIN SECTION FOR
 ADDITIONAL INFORMATION AND COORDINATION.
  
  
 3) NOTE: PLEASE SUBMIT COMPLETE ELECTRICAL PLANS FOR
 ANY SITE LIGHTING POLES, CIRCUITING, CONDUITS ETC. IF
 ONLY CONDUITS ARE GOING TO BE INSTALLED, PLEASE
 INDICATE CONDUIT, SIZE, LOCATIONS ETC.
 IF POLES WILL BE INSTALLED PLEASE SUBMIT MINIMUM WIND
 LOAD DESIGN FOR BUILDING REVIEW.
 FBC106.1.3.1.2, 106.1.2
  
 ** IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2008-09-23 Cont ID  
Sent By rchokshi Date 2008-09-23 Time 10:55 Rev Time 0.00
Received By rchokshi Date 2008-09-23 Time 10:49 Sent To  
Notes
2008-09-23 10:55:00PROVISO:
  
 YOU CAN PROVIDE REQUIREMENTS DESCRIBED IN ITEM # 1 THRU
 9, LATER DATE. PLEASE MAKE SURE YOU HAVE SFWMD PERMIT &
 STORM WATER QUALITY CALS PER SFWMD AND APPROVED BY 1000
 45TH STREET ENGINEERING SERVICES TO AVOID COSTLY REDO
 STORM WATER PIPING IN THE SITE AFTER YOU PREPARED THE
 SITE.
  
 1. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO.
 4060-07:
 ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH
 EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY
 APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE
 FOLLOWING:
  
 1. EROSION CONTROL, AND
 2. LAND STABILIZATION
  
 THE AMOUNT OF THE EROSION CONTROL AND LAND
 STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER
 OF RECORD USING THE CURRENT CITY COST SCHEDULE AND
 VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT.
 PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION
 SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION.
  
 UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN
 FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL
 TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE
 MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS.
  
 A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM
 THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR.
  
 2. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR
 SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP
 PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL
 CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING
 SERVICES, PHONE# 494-1040
  
 3. PLEASE SHOW ON DRAWINGS DUMPSTER & ITS ENCLOSURE
 DETAILS PER CITY OF WPB, & LOCATION ON DWG, LOCATION
 MUST BE ACCESSIBLE FOR PICKUP TRUCK.
  
 4. PLEASE SHOW ON DRAINAGE DRAWING THE SITE AREA,
 GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREA YOU
 ARE DEVELOPING FOR THIS PROJECT . PLEASE MAKE SURE
 THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH
 AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE
 PROVIDE A COPY OF THESE CALCULATIONS.
  
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI 805-6723
  
  
  
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2008-08-08 Cont ID  
Sent By rchokshi Date 2008-08-08 Time 13:14 Rev Time 0.00
Received By rchokshi Date 2008-08-08 Time 13:14 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2008-05-16 Cont ID  
Sent By rchokshi Date 2008-05-16 Time 14:30 Rev Time 0.00
Received By rchokshi Date 2008-05-16 Time 13:46 Sent To E
Notes
2008-05-16 14:30:30PROVISO:
  
 YOU CAN PROVIDE REQUIREMENTS DESCRIBED IN ITEM # 1 THRU
 9, LATER DATE.PLEASE MAKE SURE YOU HAVE SFWMD PERMIT
 & STORM WATER QUALITY CALSPER SFWMD AND APPROVED BY
 1000 45TH STREET ENGINEERING SERVICES TO AVOID COSTLY
 REDO STORM WATER PIPING IN THE SITE AFTER YOU PREPARED
 THE SITE.
  
 1.PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI).
 PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR
 NOI.
 YOU CAN GET NOI INFO FROM
 WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/
 NOTICE OF INTENT DEP FORM 62-621.300(4)(B),
 EFFECTIVE MAY 1, 2003
  
 2. PLEASE PROVIDE A COPY OF BOND FOR ORDINANCE NO.
 4060-07:
 ALL DEMOLITION AND NEW CONSTRUCTION PERMITS, WITH
 EXCEPTION OF SINGLE FAMILY, DUPLEX AND ACCESSORY
 APARTMENT, SHALL POST BONDS OR DEPOSITS FOR THE
 FOLLOWING:
  
 1. EROSION CONTROL, AND
 2. LAND STABILIZATION
  
 THE AMOUNT OF THE EROSION CONTROL AND LAND
 STABILIZATION BONDS SHALL BE DETERMINED BY THE ENGINEER
 OF RECORD USING THE CURRENT CITY COST SCHEDULE AND
 VERIFIED BY THE CITY'S ENGINEERING SERVICES DEPT.
 PLEASE CONTACT BRIAN MOREE, ENG SERVICES CONSTRUCTION
 SUPERVISOR, AT 561- 494 -1040 FOR MORE INFORMATION.
  
 UPON VERTICAL CONSTRUCTION COMMENCEMENT, PAYMENT IN
 FULL OF ALL APPLICABLE FEES, AND COMPLIANCE WITH ALL
 TERMS AND CONDITIONS OF ANY POSTED BOND, THE PERMITTEE
 MAY REQUEST RELEASE OF THE BONDS OR DEPOSITS.
  
 A COPY OF ORDINANCE NO. 4060-07 MAY BE OBTAINED FROM
 THE CITY CLERK'S OFFICE LOCATED ON THE FIRST FLOOR.
  
 3. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR
 SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP
 PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FOR ALL
 CITY STANDARDS NOTES FROM 1000, 45 STREET, ENGINEERING
 SERVICES, PHONE# 494-1040
  
 4. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE
 DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION
 MUST BE ACCESSIBLE FOR PICKUP TRUCK.
  
 5. PLEASE SHOW ON STORM WATER QUALITY CALCULATION THAT
 YOU HAVE CONSIDERED FLOOD ZONE AREA, & 5,10, 25, 100
 YEAR FLOOD CRITERIA AND CROWN OF THE ROAD WHEN YOU
 DETERMINE THE FIRST FLOOR ELEVATION. FIRST FLOOR
 ELEVATION SHOULD BE ATLEAST 1 FOOT HIGHER THAN HIGHEST
 CROWN OF THE ROAD.
  
 6. PLEASE SHOW ON DRAINAGE DRAWINGTHE SITE AREA,
 GREEN, LAKE,PARKING AREA, IMPERVIOUS,PERVIOUS AREAYOU
 ARE DEVELOPING FOR THIS PROJECT . PLEASEMAKE SURE
 THESE AREAS SHOWN ON DRAINAGE DRAWINGS MUST MATCH WITH
 AND USED IN STORM WATER QUALITY CALCULATIONS. PLEASE
 PROVIDE A COPY OF THESE CALCULATIONS.
  
 7. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE
 SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM
 ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE
 CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING
 ELEVATION, ETC ON DRAWINGS, CALCULATION FOR
 EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET
 DETENTION AREAS IN STORM WATER CALS IF YOU HAVE ALL
 THESE. PLEASE RESUBMIT GEO-TECH REPORT AND ALL
 ENVRONMENTAL REPORT.
  
 8. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND
 YOUR SITE FOR STORM WATER DRAIN SO YOUR SITE DO NOT GET
 FLOODED AND HAVE ENOUGH DRAINS.
  
 9. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH
 REPORT&STORM WATER QUALITY CALCULATIONS. STORM
 WATER QUALITY CALS MUST BE APPROVED FROM 100045TH
 STREET ENGINEERING SERVICES BEFORE WE ISSUE PERMIT.
  
  
 PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR
 PERMITTING PROCESS
  
 RASIK CHOKSHI805-6723

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-09-05 Cont ID  
Sent By mawillia Date 2008-09-05 Time 12:15 Rev Time 0.00
Received By mawillia Date 2008-09-05 Time 11:49 Sent To B
Notes
2008-09-05 12:10:15***** REVISION #1, DATED 7/1/2008 APPROVED*****
  
 REVISED PLAN SHEETS C001CR1, C004CR1, C012CR1, C016CR1,
 AND C023CR1 WERE STAMPED, INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-07-15 Cont ID  
Sent By mawillia Date 2008-07-15 Time 12:32 Rev Time 0.00
Received By mawillia Date 2008-07-15 Time 12:01 Sent To  
Notes
2008-07-15 12:32:17*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED; PLAN SHEETS C001P, C004P, C012P, C016P,
 AND C023P WERE STAMPED, INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-06-02 Cont ID  
Sent By mawillia Date 2008-06-02 Time 13:29 Rev Time 0.00
Received By mawillia Date 2008-06-02 Time 13:03 Sent To  
Notes
2008-06-02 13:29:28*****UNSAT*****
  
  
 1.THE ACTUAL PROJECT SITE ADDRESS SHALL BE IN THE
 TITLE BLOCK OF EACH SUBMITTED PLAN SHEET.
  
 2.THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE
 WITH EMERGENCY ACCESS TO THE PROPERTY OR THE VICINITY
 THEREOF (INCLUDING STREETS, ALLEYS, FIRE LANES,ETC) .
  
 3.ALL UNDERGROUND WATER MAINS AND HYDRANTS SHALL BE
 INSTALLED, COMPLETED, AND IN SERVICE PRIOR TO
 CONSTRUCTION WORK.
  
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE (ON THE APPROPIATE PLAN SHEET)
 EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-08-04 Cont ID  
Sent By adarroug Date 2008-08-04 Time 10:22 Rev Time 0.00
Received By adarroug Date 2008-08-04 Time 10:22 Sent To  
Notes
2008-08-04 10:25:18TO "COMM" BD#17

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-10 Cont ID  
Sent By adarroug Date 2008-06-10 Time 12:22 Rev Time 0.00
Received By adarroug Date 2008-06-10 Time 12:22 Sent To  
Notes
2008-06-10 12:29:33TO "COMM"BD#44/PLANS ON RACK--LARGE FOLDED PLANS AND
 BINDERS

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-06-02 Cont ID  
Sent By mawillia Date 2008-06-02 Time 13:03 Rev Time 0.00
Received By mawillia Date 2008-05-05 Time 16:03 Sent To  
Notes
2008-05-05 11:02:49TO "COMM" BD#17-PLANS ON RACK/1 ROLL***PRIVATE
 PROVIDER***

Review Stop L LANDSCAPING
Rev No 1 Status N Date 2008-05-05 Cont ID  
Sent By kdfreema Date 2008-05-07 Time 16:04 Rev Time 0.00
Received By kdfreema Date 2008-05-05 Time 16:04 Sent To  
Notes
2008-05-05 16:05:16PERMIT FOR FOUNDATION ONLY. LANDSCAPING PLANS WILL BE
 SUBMITTED WITH VERTICAL CONSTRUCTION PERMIT.

Review Stop Z ZONING
Rev No 1 Status P Date 2008-05-05 Cont ID  
Sent By kdfreema Date 2008-05-07 Time 16:04 Rev Time 0.00
Received By kdfreema Date 2008-05-05 Time 16:04 Sent To  
Notes
2008-05-07 11:59:58REVIEWED NEW DOCUMENTS SUBMITTED 5/6/08. PASSED STATUS
 REMAINS UNCHANGED.