Plan Review Details - Permit 08040822
Plan Review Stops For Permit 08040822
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-07-11 Cont ID  
Sent By rmcdouga Date 2008-07-11 Time 10:37 Rev Time 0.00
Received By rmcdouga Date 2008-07-11 Time 10:37 Sent To  
Notes
2008-07-11 10:39:48SIGNED AND SEALED RAS 117 CALCULATIONS FOR JOHNS
 MANVILLE MODIFIED ROOF SYSTEM AS REQUIRED BY PROVISO
 WERE SUBMITTTED AND REVIEWED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-06-12 Cont ID  
Sent By rmcdouga Date 2008-06-12 Time 14:18 Rev Time 0.00
Received By rmcdouga Date 2008-06-12 Time 14:18 Sent To  
Notes
2008-06-12 14:21:52BUILDING PROVISO
  
 SUBMIT SIGNED AND SEALED RAS 117 CALCULATIONS FOR THE
 ENHANCED FASTENING OF THE BASE SHEET AT PERIMETER AND
 CORNERS. CALCULATIONS ARE REQUIRED TO BE PREPARED BY A
 FLORIDA LICENSED ENGINEER, ARCHITECT OR REGISTERED ROOF
 CONSULTANT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-06-05 Cont ID  
Sent By tgordon Date 2008-06-12 Time 13:40 Rev Time 0.00
Received By rmcdouga Date 2008-06-05 Time 13:14 Sent To  
Notes
2008-06-05 13:54:552004 FBC W/2007 REVISIONS
 ADDITION
  
 DENIED BY BUILDING
  
 1) PLEASE SUBMIT A COPY OF THE PAID RECEIPT FOR THE
 COUNTY IMPACT FEES.
  
 2) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE
 SIGNED BY THE OWNER/AGENT. SEE FBC 13-600.
  
 3) SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES LISTED
 IN THE NOA FOR THE MODIFIED ROOFING WILL BE INSTALLED.
 SPECIFY THE FASTENING OPTION AND DESIGN PRESSURE THAT
 WILL BE USED. SUBMIT RAS 117 CALCULATIONS FOR THE
 ENHANCED FASTENING OF THE BASE SHEET AT PERIMETER AND
 CORNERS. SEE LIMITATION #7 ON PAGE 32 OF THE NOA. PAGE
 28 OF THE NOA IS FOR TORCH DOWN APP/SBS FOR
 NON-INSULATED WOOD DECKS. SOME PAGES ARE MISSING FROM
 THE NOA THAT WAS SUBMITTED. THE ROOFING CONTRACTOR CAN
 PROVIDE THIS INFORMATION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-12 Cont ID  
Sent By rmcdouga Date 2008-05-12 Time 14:40 Rev Time 0.00
Received By rmcdouga Date 2008-05-12 Time 14:40 Sent To  
Notes
2008-05-12 14:40:462004 FBC W/2007 REVISIONS
 ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE APPLICATION.
 233-5025
  
 3) SUBMIT ENERGY CALCULATIONS AS REQUIRED BY 2004 FBC
 CHAPTER 13.
  
 4) SPECIFY THE MAXIMUM SPACING ALLOWED FOR THE #5
 VERTICAL REINFORCEMENT IN THE NEW EXTERIOR WALLS. FBC
 R609.3.3
  
 5) ROOF SHEATHING IS REQUIRED TO BE IN ACCORDANCE WITH
 SECTION R803.2.3.1 OF 2006 REVISIONS TO 2004 FBC
 RESIDENTIAL CODE. WOOD STRUCTURAL PANEL SHEATHING SHALL
 BE FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS.
 PLEASE MAKE CORRECTIONS ON SHEET 5.
  
 6) SPECIFY THE COMPONENT AND CLADDING UPLIFT PRESSURES
 FOR THE FLAT ROOF ZONES 1,2 AND 3. SEE FBC TABLE
 R301.2(2) AND FIGURE R301.2(8).
  
 7)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 PLEASE USE A SHOP DRAWING REVIEW STAMP FROM THE
 ENGINEER, AS THE SIGNATURES ON THE PRODUCT APPROVALS DO
 NOT APPEAR TO BE THE ENGINEER'S.
  
 8)SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES LISTED
 IN THE NOA FOR THE MODIFIED ROOFING WILL BE INSTALLED.
 SPECIFY THE FASTENING OPTION OPTION THAT WILL BE USED
 AND THE DESIGN PRESSURE. IF ENHANCED FASTENING IS
 REQUIRED FOR THE PERIMETER AND CORNER AREAS, SUBMIT RAS
 117 CALCULATIONS.
  
 9) THE NOA FOR THE TRACO SERIES 2100 HAS BEEN
 SUPERSEDED BY NOA NO. 07-0521.06. SUBMIT THE NEW NOA.
  
 10) THE ELEVATION ON SHEET 3 OF THE PLANS SPECIFIES A
 GLAZED FRENCH DOOR WHICH WILL REQUIRE STORM PANELS IF
 IT IS NOT AN IMPACT RATED DOOR. THE PRODUCT APPROVAL
 THAT WAS SUBMITTED IS FOR AN OPAQUE STEEL DOOR. PLEASE
 CLARIFY.
  
 11) SUBMIT PRODUCT APPROVALS FOR THE STORM PANELS AS
 REQUIRED BY FBC R301.2.1.2 AND DCA RULE 9B-72. SUBMIT 2
 COPIES OF A KEY PLAN AND INSTALLATION SCHEDULE FOR THE
 STORM PANELS. SPECIFY THE OPENING SIZES, PANEL SPANS,
 FASTENER TYPE AND SPACING, CONNECTION TYPE, PRESSURES,
 ETC. SEE ATTACHED.
  
 12) PLEASE DO NOT STAPLE THE PRODUCT APPROVALS TO THE
 PLANS.
  
 13) THE DECLARED VALUE OF THE WORK IS TOO LOW. IT HAS
 BEEN ADJUSTED TO $ 65,154.00. THERE ARE ADDITIONAL
 PERMIT FEES DUE OF $199.62. FBC 108.3* CITY AMENDMENTS
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-05-05 Cont ID  
Sent By btrobaug Date 2008-05-05 Time 12:28 Rev Time 0.00
Received By btrobaug Date 2008-05-05 Time 12:00 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-12-22 Cont ID  
Sent By adarroug Date 2008-12-22 Time 11:20 Rev Time 0.00
Received By adarroug Date 2008-12-22 Time 11:20 Sent To Z
Notes
2008-12-22 11:20:49TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-07-11 Cont ID  
Sent By adarroug Date 2008-07-11 Time 08:37 Rev Time 0.00
Received By adarroug Date 2008-07-11 Time 08:37 Sent To B
Notes
2008-07-11 08:37:58TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-06-11 Cont ID  
Sent By adarroug Date 2008-06-11 Time 08:56 Rev Time 0.00
Received By adarroug Date 2008-06-11 Time 08:56 Sent To Z
Notes
2008-06-11 08:57:10TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-03 Cont ID  
Sent By adarroug Date 2008-06-03 Time 09:35 Rev Time 0.00
Received By adarroug Date 2008-06-03 Time 09:35 Sent To Z
Notes
2008-06-03 09:35:20TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-12 Cont ID  
Sent By rmcdouga Date 2008-05-12 Time 14:41 Rev Time 0.00
Received By rmcdouga Date 2008-05-05 Time 09:38 Sent To  
Notes
2008-05-05 09:38:28TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2008-12-23 Cont ID  
Sent By rkussner Date 2008-12-23 Time 12:49 Rev Time 0.00
Received By rkussner Date 2008-12-23 Time 12:49 Sent To PC
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2008-11-10 Cont ID  
Sent By rkussner Date 2008-11-10 Time 10:36 Rev Time 0.00
Received By rkussner Date 2008-11-10 Time 10:36 Sent To PC
Notes
2008-11-10 11:05:28***LANDSCAPE REVIEW FAILED***
  
 1, PLEASE PROVIDE THE LANDSCAPE TABULATION CLEARLY
 DISPLAYING THE RELEVANT STATISTICAL INFORMATION
 NECESSARY FOR THE EVALUATION OF COMPLIANCE WITH THE
 PROVISIONS OF ARTICLE XIV OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS.
  
 2, IDENTIFY ALL EXISTING AND PROPOSED PLANT MATERIAL.
  
 3. PURSUANT TO SECTION 94-442(D), PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALDL BE SODDED.
  
 4. PURSUANT TO SECTION 94-444(B), PROVIDE SCREENING FOR
 THE GROUND LEVEL AIR CONDITIONING UNITS AND POOL
 EQUIPMENT.
  
 5. PURSUANT TO SECTION 94-445(4)(G)3, AUTOMATIC
 IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED
 LANDSCAPE AREAS FOR ALL PROPERTIES. THIS INCLUDES, BUT
 IS NOT LIMITED TO, THE RIGHTS-OF-WAY.
  
 6. PROVIDE A PLANT LIST IN TABULAR FORM. IT SHALL
 IDENTIFY THE PROPOSED TREES, SHRUBS AND GROUND COVERS
 AND SHOW THE QUANTITY, SIZE AND SPACING.
  
 7. THE PROPOSED HEDGE ADJACENT TO THE CITY SIDEWALK IN
 THE CENTER OF THE DRIVEWAYS CREATES A VISIBILITY
 PROBLEM. THE HEDGTE SHALL BE INSTALLED ALONG THE INSIDE
 CURVE TO ELIMINATE THE VISIBILITY PROBLEM.
  
 8. PROVIDE LANDSCAPING ALONG THE FRONT BUILDING
 ELEVATION.
  
 9. NOTES IDENTIFYING THE DEPTH OF MULCH, REQUIRED PLANT
 QUALTIY AND IRRIGATION REQUIREMENTS SHALL APPEAR ON THE
 LANDSCAPE PLAN.
  
 10. ON THE LANDSCAPE PLAN, PLEASE SHOW ALL OVERHEAD
 LINES, EASEMENTS AND OTHER UTILITIES THAT MAY INTERFERE
 WITH THE PROPOSED LANDSCAPING.
  
 IF YOU HAVE ANY QUESTIONS REGARDING THESE COMMENTS,
 PLEASE CONTACT ROBERT KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-06-12 Cont ID  
Sent By tgordon Date 2008-06-12 Time 08:16 Rev Time 0.45
Received By tgordon Date 2008-06-12 Time 08:16 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-06-03 Cont ID  
Sent By tgordon Date 2008-06-03 Time 11:33 Rev Time 0.45
Received By tgordon Date 2008-06-03 Time 11:33 Sent To B
Notes
2008-06-03 12:02:39PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS LINE 11A IS STATING THE SUPPLY
 AND RETURN AIR DUCTS ARE IN A CONDITIONED SPACE, AND
 THE AIR HANDLER IS IN THE INTERIOR. THE MECHANICAL
 PLANS SHOW THE SUPPLY AIR DUSTS ARE IN THE ATTIC, SHOWS
 NO RETURN AIR DUCTS, AND SHOWS THE AIR HANDLER IN THE
 ATTIC. PLEASE CORRECT THE ENERGY CALCULATIONS, PER 2004
 FBC 13-600.3.A.
  
 2) WHEN RESUBMITTING THE ENERGY CALCULATIONS THEY MUST
 BE SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC 13-103.3.
  
 3) THE COOLING LOAD CALCULATIONS ARE CALLING FOR 27,626
 TOTAL BTU'S, AND THE MECHANICAL PLAN EQUIPMENT LISTING
 IS SHOWING 41,200 TOTAL BTU'S. THE PLANS CAN ONLY CALL
 FOR 15% MORE TOTAL BTU'S THAN THE COOLING LOAD CAL'S.
 PER 2004 FBC 13-607.1.ABC.1.1, PLEASE CORRECT.
  
 4)A/C SYSTEM MODEL NUMBERS LISTED ON THE A/C
 EQUIPMENT SCHEDULE A/H FKYCNB005 AND C/U 38BRL042-3
 COULD NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE,
 PLEASE CORRECT OR SUBMIT AN ARI CERTIFICATE, SEE 2004
 FBC 13-607.1.ABC.3.1.1.
  
 5) THE PLAN SHOWS NO A/C GOING TO THE PROPOSED BEDROOM
 PLEASE CORRECT OR STATE NO A/C THIS ROOM ON PLAN.
  
 6) PLANS SHOW NO RETURN AIR TO AIR HANDLER PLEASE SHOW
 ON PLAN HOW THE AIR IS RETURNING TO THE AIR HANDLER,
 PER 2004 FBC/R M1602.4.
  
 7) PLEASE PROVIDE FOR RETURN AIR TO THE PROPOSED STUDY
 AND PROPOSED BEDROOM (IF A/C), PER 2004 FBC/R M1602.4.
  
 8) PLEASE SHOW THE ATTIC ACCESS TO THE AIR HANDLER ON
 MECHANICAL PLAN, PER 2004 FBC/R M1305.1.3.
  
 9) THE MECHANICAL PLANS NEED THE PRINTED NAME WITH THE
 SINGATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN, AND
 CONTRACTOR INFORMATION IF APPLICABLE ON THEM, SEE
 W.P.B. AMEND. 106.1.3.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-05-06 Cont ID  
Sent By tgordon Date 2008-05-06 Time 13:59 Rev Time 0.30
Received By tgordon Date 2008-05-06 Time 13:59 Sent To P
Notes
2008-05-06 14:05:32PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
  
 1) SUBMIT ENERGY CALCULATIONS, PER 2004 FBC13-101.2.2.
  
 2) SUBMIT MECHANICAL (A/C) PLANS FOR REVIEW, AS NO
 MECHANICAL PLAN WAS SUBMITTED WITH THIS APPLICATION.
 PER 2004 WPB AMEND. 106.3.5.4 (10).
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2008-05-08 Cont ID  
Sent By jleech Date 2008-05-08 Time 08:58 Rev Time 0.00
Received By jleech Date 2008-05-08 Time 08:52 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2008-06-11 Cont ID  
Sent By choops Date 2008-06-11 Time 14:44 Rev Time 0.00
Received By choops Date 2008-06-11 Time 14:44 Sent To M
Notes
2008-06-11 14:56:29***APPROVED - RESUB #2***
  
 PROVISOS:
 1)AS THE PROVIDED SURVEYS/SITE PLANS ARE INACCURATE,
 A FORM BOARD SURVEY AND UPDATED SITE PLAN (TO MATCH
 SURVEY) SHALL BE PROVIDED SHOWING COMPLIANCE WITH THE
 MINIMUM REQUIRED SETBACKS PER SECTION 94-72 OF THE
 CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS):
 AS THE EXISTING NORTH SIDE SETBACK IS 7.0 FEET (TO THE
 ATTACHED SHED), THE MINIMUM SOUTH SIDE SETBACK TO THE
 NEW ADDITION SHALL BE 8.0 FEET.THE FRONT SETBACK
 SHALL BE A MINIMUM OF 25'.
  
 2)THE PROPOSED POOL AND A/C EQUIPMENT SHALL NOT
 PROJECT MORE THAN 4 FEET INTO THE REQUIRED 8 FOOT SOUTH
 SIDE SETBACK, YIELDING A MINIMUM REQUIRED SETBACK OF 4
 FEET TO ANY MECHANICAL EQUIPMENT ALONG THAT SIDE.
  
 3)PRIOR TO ISSUANCE OF A CO, A LANDSCAPE PLAN SHOWING
 COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE ZLDRS
 SHALL BE SUBMITTED TO AND APPROVED BY THE CITY'S
 PLANNING & ZONING DEPARTMENT VIA THE CONSTRUCTION
 SERVICES' SUBMITTAL PROCESS.
  
  
  
  
 SENT TO "M" - TG

Review Stop Z ZONING
Rev No 2 Status F Date 2008-06-03 Cont ID  
Sent By choops Date 2008-06-03 Time 10:09 Rev Time 0.00
Received By choops Date 2008-06-03 Time 10:09 Sent To M
Notes
2008-06-03 10:21:00***FAILED - RESUB #1***
  
  
 1)THE SURVEY AND SITE PLAN (SHEET 1) DO NOT MATCH
 WITH RESPECT TO THE EXISTING AND PROPOSED SETBACK
 DIMENSIONS.PLEASE CLARIFY.THE SIDE SETBACKS AS
 SHOWN ON THE SURVEY DO NOT MEET THE MINIMUM REQUIRED BY
 SECTION 94-72 OF THE CITY'S ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDRS):SIDE = 5' MINIMUM WITH A TOTAL OF
 15' BETWEEN THE TWO SIDES, THE SURVEY SHOWS A TOTAL OF
 14.8'.PLEASE REVISE, ALL PLANS SHALL
 CORRESPOND/MATCH.
  
 2)AS THE VALUE OF THE WORK HAS INCREASED TO
 ACCURATELY REFLECT THE SCOPE OF WORK, IT NOW TRIGGERS
 SECTION 94-441(C)(2) OF THE ZLDRS: AS THE VALUE OF THE
 PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDRS.PLEASE SUBMIT A LANDSCAPE PLAN SHOWING
 COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE
 ZLDRS.
  
 3)THE POOL EQUIPMENT AS SHOWN ON THE SURVEY MUST BE A
 MINIMUM OF 4.1 FEET FROM THE SOUTH SIDE PROPERTY LINE.
 AS PER SECTION 94-305(B)(4) OF THE ZLDRS: MECHANICAL
 EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A
 REQUIRED SETBACK.PLEASE REVISE.
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "M" - TG

Review Stop Z ZONING
Rev No 1 Status F Date 2008-05-06 Cont ID  
Sent By choops Date 2008-05-06 Time 11:07 Rev Time 0.00
Received By choops Date 2008-05-06 Time 11:07 Sent To M
Notes
2008-05-06 11:08:22***FAILED***
  
  
 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY WHICH
 INCLUDES THE PROPERTY'S LEGAL DESCRIPTION AND ADDRESS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "M" - SF RACK