Plan Review Details - Permit 08040808
| Plan Review Stops For Permit 08040808 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-06-11 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-06-11 |
Time |
14:52 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-05-02 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-05-02 |
Time |
16:38 |
Sent To |
PC |
|
| Notes |
| 2008-05-02 17:01:07 | RESIDENTIAL (R3)SCREEN ENCLOSURE, BUILDING REVIEW | | | CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- ACCORDING TO SEC. 1609.4(3)STRUCTURE IS LOCATED ON | | | EXPOSURE "C", NOT "B".SOUTH EASTQUADRANT OF THE | | | HOUSE IS EXPSOSURE "C".REVISE ALL DESIGN CRITERIA AS | | | REQUIRED TO COMPLY WITH EXPOSURE "C". | | | | | | 2- SITE SPECIFIC DRAWINGS TO SPECIFYALLMEMBERS | | | SIZES, INCLUDINGCORNER COLUMNS,ALL SECONDARY | | | MEMBERS AND BRACING MEMBERS.SEC.106.1.2 CITY | | | AMENDMENTS TO FBC 2004.DRAWINGS SUBMITTED ARE | | | INCOMPLETE. | | | ALSO, THERE IS NOT INFORMATION GIVEN FOR SIDE EAST | | | WALL. | | | | | | 3- SITE SPECIFIC DRAWING GENERAL NOTE #4 STATES THAT | | | DOORSARE OPTIONAL AND CONTRACTOR TO VERIFY LOCATION. | | | THIS IS PART OF THE DESIGN. IF DOORSAREPROVIDED, | | | THEN THEY SHOULD BE SHOWN ON THE SITE SPECIFIC DRAWINGS | | | AND FRAMING MEMBERS SPECIFIED. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 4-ONE DRAWING A-1 IS MISSING THE ENGINEER'S SEAL. | | | ALSO,BOTH DRAWINGS ARE NUMBERED A-1. IT SHOULD BE A-1 | | | AND A-2, NOT BOTH A-1. REVISE AS REQUIRED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-02 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-02 |
Time |
09:51 |
Sent To |
Z |
|
| Notes |
| 2008-06-02 09:51:24 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-05-02 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-05-01 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2008-05-01 10:50:34 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-06 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-06 |
Time |
08:33 |
Sent To |
B |
|
| Notes |
| 2008-06-06 08:33:26 | ***APPROVED - RESUB #1*** | | | | | | | | | | | | | | | SENT TO "B" - JG |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-05-01 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-05-01 |
Time |
15:22 |
Sent To |
B |
|
| Notes |
| 2008-05-01 15:24:13 | ***FAILED*** | | | | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM THE PROPOSED | | | SCREEN ENCLOSURE TO ALL PROPERTY LINES. | | | | | | 2)PROVIDE RIVERWALK ACC (ARCHITECTURAL CONTROL | | | COMMITTEE) APPROVAL. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | | | | SENT TO "B" - MISC. 2 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |