Plan Review Details - Permit 08040678
Plan Review Stops For Permit 08040678
Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2009-04-24 Cont ID  
Sent By jgomez Date 2009-04-24 Time 10:33 Rev Time 0.00
Received By jgomez Date 2009-04-24 Time 10:33 Sent To  
Notes
2009-04-24 10:34:33RE-STAMP STAIRS REVISION BECAUSE IT WAS MISPLACED. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2009-04-08 Cont ID  
Sent By jgomez Date 2009-04-08 Time 10:28 Rev Time 0.00
Received By jgomez Date 2009-04-08 Time 10:28 Sent To  
Notes
2009-04-08 10:29:13STAIRS REVISION. OK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2009-03-16 Cont ID  
Sent By jgomez Date 2009-03-16 Time 16:37 Rev Time 0.00
Received By jgomez Date 2009-03-16 Time 16:37 Sent To PC
Notes
2009-03-16 16:42:19BUILDING SUBMITTAL CHECKLIST.
  
 1- ALL ITEMS REQUESTED ON PROVISO ARE ADDRESSED EXCEPT
 THE STAIRS RATIO REQUIRED BY SEC. R311.5.3.2 OF 2004
 FLORIDA RESIDENTIAL CODE. THE SUM OF 2 RISERS AND 1
 TREAD MUST BE BETWEEN 24 AND 25. THE TREAD'S NOSING
 CAN'T BE CONSIDERED FOR THE SIZE OF THE TREAD. SEE
 ATTACHED DRAWING FROM THE COMMENTARY BOOK WHICH
 EXPLAINS HOW TO DIMENSION THE STAIRS TO GET PROPER
 RATIO.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2009-03-05 Cont ID  
Sent By jgomez Date 2009-03-05 Time 15:28 Rev Time 0.00
Received By jgomez Date 2009-03-05 Time 15:28 Sent To PC
Notes
2009-03-05 15:30:21SKYLIGHT REVISION CHECKLIST:
  
 1- SKYLIGHT INFORMATION SUBMITTED FL3130-R3 IS A
 REVISION, NOT A SUBMITTAL. PRODUCT APPROVAL FOR
 SKYLIGHT WAS ALREADY APPROVED. IT WAS NOA 07-0810.02.
 THEREFORE, OWES $80.00 FOR REVISION FEES.
  
 2- PRODUCT APPROVAL FL3130-R3 SUBMITTED DOESN'T MEET
 THE DESIGN PRESSURES CALCULATED BY THE ARCHITECT.
  
 3- ACCORDING TO HALLMARK CERTIFICATE OF CONFORMANCE AND
 LICENSE SHEET (CCL) THE PRODUCT APPROVAL IS EXPIRED.
 NEED TO PROVIDE INFORMATION FOR CURRENT PRODUCT
 APPROVAL.
  
 4- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT
 SIGNING AND SEALING) PRODUCT APPROVAL PRIOR TO
 SUBMITTAL TO THIS OFFICE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2009-02-18 Cont ID  
Sent By jgomez Date 2009-02-18 Time 17:06 Rev Time 0.00
Received By jgomez Date 2009-02-18 Time 17:06 Sent To Z
Notes
2009-02-18 17:59:12BUILDING REVIEW CHECKLIST FOR ITEMS REQUESTED ON
 PROVISO DATED 08/07/08:
  
  
 ***NOTE: PROVISO WAS ISSUED TO ALLOW CONSTRUCTION TO
 PROCEED AND AVOID CONFLICTS OR DELAYS. AS OF NOW
 PROVISO INFORMATION IS STILL NOT SUBMITTED.
  
  
 1- THIS ITEM WAS ADDRESSED.
  
 2- THIS ITEM WAS NOT ADDRESSED:
 RAS 117 CALCULATIONS FOR WATERPROOFING SYSTEM NEED TO
 BE SIGNED AND SEALED AS REQUIRED BY GENERAL LIMITATION
 #7.
 ***NO INFORMATION SUBMITTED. NEED COMPLETE PRODUCT
 APPROVAL ALONG WITH THE RAS 117 CALCULATIONS. NO
 INFORMATION SUBMITTED.
  
 3- NEED TO PROVIDE ELEVATION CERTIFICATE FOR ENTIRE
 BUILDING AS REQUIRED BY CITY ORDINANCE SEC.
 94-546(B)(1). MIN. FINISH FLOOR ELEVATION TO BE 7.5'
 SINCE BASE FLOOD ELEVATION IS 7.0'.
 ***NOTE: THIS IS TO BE PROVIDED LATER ON TO THE
 BUILDING INSPECTOR PRIOR TO C.O..
  
 4- THIS ITEM WAS NOT ADDRESSED:
 REVISE ENERGY CALCULATIONS TO INCLUDE THE SQUARE
 FOOTAGE FOR NEW STAIRWAY.
 ***NO INFORMATION SUBMITTED.
  
 5- REVISE STAIR CALCULATIONS TO COMPLY WITH RATIO OF
 SEC. R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE.
 ***INFORMATION SUBMITTED ON SHEET A-7 DOESN'T COMPLY
 WITH THE RISER/TREAD RATIO. 6-11/16" RISERS AND 9-1/2"
 TREADS DON'T COMPLY WITH THE 2R+1T RATIO. REVIEW THE
 ABOVE MENTIONED SECTION AND REVISE AS REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2009-01-30 Cont ID  
Sent By jgomez Date 2009-01-30 Time 13:02 Rev Time 0.00
Received By jgomez Date 2009-01-30 Time 13:02 Sent To PC
Notes
2009-01-30 13:20:05BUILDING REVISION CHECKLIST:
  
 1- COMMENTS ON THE REVISION SUBMITTAL FORM ONLY
 SPECIFIES REVISION OF STRAPPING AND BOLTING OF BEAMS.
 PLANS SUBMITTED SHOWS NOT ONLY STRAPPING AND BOLTING
 REVISION BUT FLOOR PLANS REVISIONS AS WELL. WEST
 ELEVATION WAS CHANGED ALSO. THEREFORE, NEED TO BRING
 PLANS TO HISTORIC TO GET APPROVAL STAMP.
  
 2- SHEET S-1:
 A) CONNECTOR MTS18 SPECIFIED ON DETAIL 4/S-1 IS NOT A
 JOIST HANGER CONNECTOR. THIS CONNECTOR CAN'T BE USED AS
 A JOIST HANGER. SEE SIMPSON CATALOG FOR PROPER TYPE OF
 HANGER TO BE USED AND REVISE AS REQUIRED. ALSO, REVISE
 HANGERS SPECIFIED ON SECOND FLOOR FRAMING PLAN AS
 REQUIRED TO MATCH REVISED DETAIL 4/S-1.
  
 B) CLARIFY WHAT KIND OF CONNECTOR IS JUS210 SPECIFIED
 SECOND FLOOR FRAMING PLAN ON BEAM BY MASTER BEDROOM
 AREA.
  
 3- NEW REVISED FLOOR FRAMING PLANS SHOW NEW AREAS TO
 HAVE NEW FRAMING. UPDATE VALUE TO INCLUDE THE
 ADDITIONAL WORK AS REQUIRED BY SEC. 108.3 CITY
 AMENDMENTS TO FBC 2004. PERMIT FEES WILL BE ADJUSTED
 ACCORDINGLY.
  
 4- PROVIDE INFORMATION REQUESTED ON PROVISO DATED
 08/07/08. SEE ATTACHED COPY. PROVIDE REQUIRED
 INFORMATION TO AVOID CONFLICT OR DELAYS IN THE
 CONSTRUCTION PROCESS.
  
 5- NUMBER OF REVISED PAGES ARE 10, NOT 4 AS SPECIFIED
 ON REVISION SUBMITTAL FORM. THEREFORE OWES $180 FOR
 REVISION FEES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-10-31 Cont ID  
Sent By jgomez Date 2008-10-31 Time 13:56 Rev Time 0.00
Received By jgomez Date 2008-10-31 Time 13:43 Sent To  
Notes
2008-10-31 13:58:09PLANS REVIEWED FOR IMPACT FEES STAMP TO PASS BUILDING
 STOP. PLANS APPROVED WITH PROVISO DATED 8-7-08.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date 2008-08-07 Cont ID  
Sent By jgomez Date 2008-08-07 Time 16:24 Rev Time 0.00
Received By jgomez Date 2008-08-07 Time 16:23 Sent To PC
Notes
2008-08-08 11:09:49BUILDING REVIEW APPROVED WITH PROVISO.
 1- REVISE AREA CALCULATIONS.
 2- RAS 117 CALCULATIONS FOR WATERPROOFING SYSTEM NEED
 TO BE SIGNED AND SEALED AS REQUIRED BY GENERAL
 LIMITATION #7.
 3- NEED TO PROVIDE ELEVATION CERTIFICATE FOR ENTIRE
 BUILDING AS REQUIRED BY CITY ORDINANCE SEC.
 94-546(B)(1). MIN. FINISH FLOOR ELEVATION TO BE 7.5'
 SINCE BASE FLOOD ELEVATION IS 7.0'.
 4- REVISE ENERGY CALCULATIONS.
 5- REVISE STAIR CALCULATIONS TO COMPLY WITH RATIO OF
 SEC. R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-05 Cont ID  
Sent By jgomez Date 2008-05-05 Time 14:49 Rev Time 0.00
Received By jgomez Date 2008-05-05 Time 07:48 Sent To M
Notes
2008-05-05 16:23:15RESIDENTIAL (R3) ADDITION AND ALTERATION, BUILDING
 REVIEW CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD
 (561)233-5120)TO CHECK IF IMPACT FEES ARE DUE. BRING
 BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE
 DUE.
  
 3- AREA CALCULATIONS ON SHEET SP-1 NEED TO SPECIFY
 ADDITION AREAS INCLUDING THE NEW STAIRWAY AND ADDITION
 FOR NEW GUEST ROOM TO PROPERLY ASSESS THE RADON FEES.
  
 4- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) ROOF TILE.
 B) POLYFOAM IF USED FOR ROOF TILE.
 C) * FLAT ROOF APPROVED ASSEMBLY ON PAGE 4 OF NOA
 07-0212.03 IS FOR AN INSULATED ASSEMBLY. PLANS DON'T
 SHOW AN INSULATED ASSEMBLY. CLARIFY/REVISE AS
 REQUIRED.
 ** PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREASAS REQUIRED BY GENERAL
 LIMITATION #7.
 ***NOTE: THIS SYSTEM WILL REQUIRE AT LEAST 4 ROWS IN
 THE FIELD AREA OF THE ROLL. SEE ATTACHED CALCULATIONS.
 3" SPACING IS NOT ALLOWED.
 D) FRENCH DOORS THAT RESIST THE DESIGN PRESSURES
 CALCULATED ON SHEET S-3 FOR D2 DOORS.
 E) SKYLIGHT ABOVE STAIRWAY.
  
 5- ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND
 APPROVED IN WRITING (NOT SIGNING AND SEALING).PRODUCT
 APPROVALS SUBMITTED HAVE THE REVIEW STAMP, BUT THEY
 WERE NOT SIGNED. ONLY THE DATE WAS PROVIDED.
  
 6- ENERGY CALCULATIONS:
 A) COMPLETE ALL THE INFORMATION ON TOP OF FORM.
  
 B ) SPECIFY HOW IS THE R6.0 INSULATION INSTALLED ON
 THE CONCRETE SLAB. SEE ITEM #8(A).
 C) NEED TO ADD THE AREA FOR THE ADDITION BY NEW
 GUEST ROOM.ALSO,WINDOWS AND DOORSON THE GUEST
 ROOM NEED TO BE INCLUDED ON THE SECOND PAGE.
 D) COMPLETE THE CODE COMPLIANCE CHECKLIST.
  
 ***NOTE: SHORT FORM 600C-04R IS THE MOST ADEQUATE FORM
 TO BE USED FOR THIS PROJECT INSTEAD OF THE 600A-04R
 FORM SUBMITTED.
  
 7- ELEVATION CERTIFICATE NEED TO HAVE SURVEYORS
 ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 472
 FLORIDA STATUTE.THISCERTIFICATE WILL BE REQUIRED AT
 THE END OF THE CONSTRUCTION TO GET THE C.O.
  
 8- DOOR #11 SPECIFIED FOR NEW GUEST BATHROOM IN THE
 DOOR SCHEDULEDOESN'T MATCHDOOR SHOWN ON FIRST FLOOR
 PLAN. REVISE AS REQUIRED.
  
 9- PROVIDE SPECIFICATIONS FOR ICYNENE INSULATION TO
 VERIFY COMPLIANCE WITHENERGY CALCULATIONS AND PLAN
 SPECIFICATIONS.
  
 10- SHEET A-7:A) REVISE STAIR CALCULATIONS TO COMPLY
 WITH SEC. R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE.
 NEED RISER AND TREAD RATIO BETWEEN 24 AND 25.
 B) REVISE RAILING DETAILTO COORDINATE WITH RISER
 AND TREAD DIMENSIONS SHOWN ON SECTION A-STAIR DETAIL
 AND FLOOR PLANS. ALSO, COORDINATE WITH ITEM #7(A)
 ABOVE.
  
 11- SHEET S-1: A) SPECIFY CONNECTORS AT THE ENDS OF NEW
 BEAMS WHERE OLD STAIRS WERE DEMOLISHED.
 B) DETAIL 3/S-1: SPECIFY SIZE OF REBAR CONNECTING
 EXISTING FOOTING TO NEW FOOTING.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-08-05 Cont ID  
Sent By btrobaug Date 2008-08-05 Time 14:21 Rev Time 0.00
Received By btrobaug Date 2008-08-05 Time 13:22 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-04-25 Cont ID  
Sent By btrobaug Date 2008-04-25 Time 13:39 Rev Time 0.00
Received By btrobaug Date 2008-04-25 Time 07:07 Sent To Z
Notes
2008-04-25 12:05:30 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004
 FBC CHAPTER 1 AS AMENDED AND FOUND NONCOMPLIANT WITH
 THE FOLLOWING:
  
 1} REGARDING THE MAIN HOUSE DISCONNECT , SHEET E-3, A
 GROUNDING ELECTRODE CONDUCTOR IS REQUIRED AT THE
 SEPARATE STRUCTURE PER 250.32, SIZED PER 250.66.
  
 2} CIRCUIT B-3 LISTED AS THE LAUNDRY CIRCUIT IS IN
 VIOLATION OF 210.11(C)(2) "THIS CIRCUIT SHALL HAVE NO
 OTHER OUTLETS." THE LIGHTS CANNOT BE ON THE CIRCUIT.
  
 3} THE DRYER LISTED ON CIRCUIT 4-6 PANEL "B" APPEARS TO
 BE A STACK UNIT ON SHEET E-1, CLARIFY AND CORRECT
 SCHEDULE "B" ACCORDINGLY.
  
 4} LOCATE BOTH AHU'S ON THE PLAN.106.1.1 FBC.
  
 5} BATH CIRCUIT B-5 DOES NOT COMPLY WITH 210.11(C)(3)
 "SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS." THE
 RECEPTACLE IN THE "POWDER" AND BATH" ROOM, SHEET E-1
 COULD BE ON THAT CIRCUIT, BUT NOT THE LIGHTS.OR THE
 LIGHTS AND RECEPTACLE IN EITHER ONE COULD BE ON THAT
 CIRCUIT. SEE EXCEPTION: WHERE THE 20-AMPERE CIRCUIT
 SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT
 WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE
 SUPPLIED IN ACCORDANCE WITH 210.23(A)(1) AND (A)(2).
  
 6} CIRCUIT B7 INDICATES IT SERVES THE HALL AS WELL AS
 THE BEDROOM. SHEET E-1 INDICATES CIRCUIT B12 IN THE
 HALL, CORRELATE THE CIRCUITS.
  
 210.52(E) OUTDOOR OUTLETS FOR A ONE-FAMILY DWELLING AND
 EACH UNIT OF A TWO-FAMILY DWELLING THAT IS AT GRADE
 LEVEL, AT LEAST ONE RECEPTACLE OUTLET ACCESSIBLE AT
 GRADE LEVEL AND NOT MORE THAN 2.0 M (6 1/ 2 FT) ABOVE
 GRADE SHALL BE INSTALLED AT THE FRONT AND BACK OF THE
 DWELLING.
  
 NOTE: CONFIRM THE AHU LOADS ARE 4800 WATTS TOTAL HEAT
 FOR 2855 SQ FT RESIDENCE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2009-02-24 Cont ID  
Sent By lwagner Date 2009-02-24 Time 15:31 Rev Time 0.00
Received By lwagner Date 2009-02-24 Time 15:31 Sent To  
Notes
2009-02-24 15:31:54REVISION OK

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2008-08-07 Cont ID  
Sent By mperson Date 2008-08-07 Time 09:30 Rev Time 0.00
Received By mperson Date 2008-08-07 Time 09:30 Sent To B
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2008-04-30 Cont ID  
Sent By mperson Date 2008-04-30 Time 08:55 Rev Time 0.00
Received By mperson Date 2008-04-30 Time 08:55 Sent To B
Notes
2008-04-30 09:02:48GAS PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET P-3 GAS DISTRIBUTION ISOMETRIC: THE GAS
 PIPING TO THE TANKLESS WATER HEATER NEEDS TO BE
 INCREASED TO 1". PER FBC-2004 FUEL GAS TABLES 402.4(2)
 AND 402.4 (20). PLEASE REFERENCE THE ATTACHED TABLES TO
 THESE COMMENTS INDICATING THIS FOR THE RESUBMITTAL.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2009-02-17 Cont ID  
Sent By swurafti Date 2009-02-17 Time 15:24 Rev Time 0.00
Received By swurafti Date 2009-02-17 Time 15:24 Sent To  
Notes
2009-02-17 15:24:52HISTORIC FOR REV DATED 2/17/09 APPROVED BY FMITTNER

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2009-04-17 Cont ID  
Sent By swurafti Date 2009-04-17 Time 11:30 Rev Time 0.00
Received By swurafti Date 2009-04-17 Time 11:30 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2009-04-07 Cont ID  
Sent By adarroug Date 2009-04-07 Time 10:05 Rev Time 0.00
Received By adarroug Date 2009-04-07 Time 10:05 Sent To L
Notes
2009-04-07 10:06:30TO "Z" BOX/REV (FOR LANDSCAPING)

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2009-04-06 Cont ID  
Sent By adarroug Date 2009-04-06 Time 13:16 Rev Time 0.00
Received By adarroug Date 2009-04-06 Time 13:16 Sent To P
Notes
2009-04-06 13:16:58TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2009-03-30 Cont ID  
Sent By adarroug Date 2009-03-30 Time 16:41 Rev Time 0.00
Received By adarroug Date 2009-03-30 Time 16:41 Sent To  
Notes
2009-03-30 16:46:39TO "R6"

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2009-03-03 Cont ID  
Sent By adarroug Date 2009-03-03 Time 16:19 Rev Time 0.00
Received By adarroug Date 2009-03-03 Time 16:19 Sent To B
Notes
2009-03-03 16:19:34TO "JGOMEZ" DES/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2009-02-27 Cont ID  
Sent By adarroug Date 2009-02-27 Time 09:06 Rev Time 0.00
Received By adarroug Date 2009-02-27 Time 09:06 Sent To B
Notes
2009-02-27 09:07:12TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2009-02-18 Cont ID  
Sent By adarroug Date 2009-02-18 Time 10:56 Rev Time 0.00
Received By adarroug Date 2009-02-18 Time 10:56 Sent To B
Notes
2009-02-18 10:57:00TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-02-12 Cont ID  
Sent By adarroug Date 2009-02-12 Time 15:24 Rev Time 0.00
Received By adarroug Date 2009-02-12 Time 15:24 Sent To G
Notes
2009-02-12 15:27:16TO "G" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2009-01-29 Cont ID  
Sent By adarroug Date 2009-01-29 Time 11:32 Rev Time 0.00
Received By adarroug Date 2009-01-29 Time 11:32 Sent To B
Notes
2009-01-29 11:32:33TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-12-19 Cont ID  
Sent By adarroug Date 2008-12-19 Time 09:35 Rev Time 0.00
Received By adarroug Date 2008-12-19 Time 09:35 Sent To M
Notes
2008-12-19 09:38:10TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-09-12 Cont ID  
Sent By adarroug Date 2008-09-12 Time 15:34 Rev Time 0.00
Received By adarroug Date 2008-09-12 Time 15:34 Sent To Z
Notes
2008-09-12 15:34:54TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-07-29 Cont ID  
Sent By adarroug Date 2008-07-29 Time 08:48 Rev Time 0.00
Received By adarroug Date 2008-07-29 Time 08:48 Sent To  
Notes
2008-07-29 08:50:41TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-07 Cont ID  
Sent By jgomez Date 2008-05-07 Time 11:14 Rev Time 0.00
Received By jgomez Date 2008-04-24 Time 16:49 Sent To  
Notes
2008-04-24 16:49:33TO "SFR" "Z"

Review Stop L LANDSCAPING
Rev No 3 Status P Date 2009-04-09 Cont ID  
Sent By rkussner Date 2009-04-09 Time 12:18 Rev Time 0.00
Received By rkussner Date 2009-04-09 Time 12:18 Sent To PC
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2008-11-04 Cont ID  
Sent By rkussner Date 2008-11-04 Time 13:17 Rev Time 0.00
Received By rkussner Date 2008-11-04 Time 13:16 Sent To PC
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2008-09-22 Cont ID  
Sent By rkussner Date 2008-09-22 Time 14:11 Rev Time 0.00
Received By rkussner Date 2008-09-22 Time 14:11 Sent To  
Notes
2008-09-22 14:38:19***LANDSCAPE REVIEW FAILED***
  
 1. THE LANDSCAPE PLAN SHALL BE DRAWN TO SCALE. PLEASE
 DRAW THE LANDSCAPE PLAN AT THE SAME SCALE AS THE SITE
 PLAN. THE EXISTING LANDSCAPE PLAN IS NOT CONSISTENT
 WITH THE SITE PLAN REGARDING THE HARDSCAPE AND
 STRUCTURES.
  
 2. SHOW ALL STREETS, UTILITIES, EASEMENTS, EXISTING
 TREES ON NEIGHBORING PROPERTY IN CLOSE PROXIMITY TO THE
 PROPERTY LINE THAT MAY IMPEDE THE GROWTH OF PROPOSED
 TREES, TRASH/GARBAGE AREAS WITH SCREENING, GROUND LEVEL
 AIR CONDITIONING UNITS AND OTHER MECHANICAL EQUIPMENT
 WITH SCREENING AND ANYTHING ELSE THAT MAY INTERFERE
 WITH THE PROPOSED LANDSCAPING.
  
 3. PROVIDE ALL REQUIRED LANDSCAPE CALCULATIONS BASED
 UPON ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 4. PROVIDE A LANDSCAPE PLANT LIST WITH ALL PROPOSED
 PLANT MATERIAL, SIZE (NOT CONTAINER SIZE) AND SPACING.
  
 5. PROVIDE SOD AND IRRIGATION IN THE RIGHTS-OF-WAY.
  
 6. SHOW THE VISIBILITY TRIANGLE.
  
 7. TREES CANNOT BE PLANTED IN THE RIGHT-OF-WAY WITHOUT
 APPROVAL OF THE ENGINEERING DEPARTMENT.
  
 8. IDENTIFY ALL EXISTING TREES ON SITE. IF ANY TREES
 WILL BE REMOVED, A TREE ALTERATION PERMIT APPLICATION
 SHALL BE REQUIRED.
  
 9. NO SHADE TREES HAVE BEEN PROPOSED. ONE SHADE OR
 FLOWERING TREE SHALL BE PLANTED FOR EACH 1200 SQUARE
 FEET OF OPEN SPACE.
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2008-12-20 Cont ID  
Sent By rregueir Date 2008-12-20 Time 14:39 Rev Time 0.00
Received By rregueir Date 2008-12-20 Time 14:36 Sent To PC
Notes
2008-12-20 14:39:47REVIEW #: REVISION 1
 ACTION: DENOED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 THE PERMIT RECORD SET OF PLANS WERE PREPARED, SIGNED
 AND SEALED BY AN ARCHITECT. RAFAEL RODRIGUEZ IS THE
 DESIGNER OF RECORD FOR THIS PERMIT. PLANS MAY ONLY BE
 REVISED BY THE DESIGNER OF RECORD IN ACCORDANCE WITH
 F.S. 481 AND FBCB 106.1.3. PROVIDE REVISIONS WHICH WERE
 PREPARED, SIGNED AND SEALED BY THE DESIGNER OF RECORD
 IN ORDER TO BE REVIEWED FOR CODE COMPLIANCE.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-08-06 Cont ID  
Sent By tgordon Date 2008-08-06 Time 09:12 Rev Time 0.45
Received By tgordon Date 2008-08-06 Time 09:12 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-05-06 Cont ID  
Sent By tgordon Date 2008-05-06 Time 13:21 Rev Time 1.15
Received By tgordon Date 2008-05-06 Time 13:21 Sent To B
Notes
2008-04-28 10:48:21PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) THE ENERGY CALCULATIONS FORM 600A-2004R MAY NOT BE
 USED FOR A RENOVATION, PLEASE SUBMIT FORM 600C-04R PER
 2004 FBC 13-101.2.3.
  
 2) PLEASE PROVIDE FOR RETURN AIR TO THE NEW OFFICE ON
 THE FIRST FLOOR, PER 2004 FBC/R M1602.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop P PLUMBING
Rev No 6 Status F Date 2009-05-04 Cont ID  
Sent By kstevens Date 2009-05-04 Time 15:47 Rev Time 0.00
Received By kstevens Date 2009-05-04 Time 15:47 Sent To  
Notes
2009-05-04 15:51:16DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 ****FROM PREVIOUS REVISION REVIEW:
  
 1. SHT P-3 THE SANITARY RISER DIAGRAM AND THE WATER
 RISER DIAGRAM DO NOT REFLECT THE CHANGES INDICATED ON
 SHT P-2 FOR THE BATHROOM CHANGES SUBMITTED THIS
 REVISION. SECTIONS 106.1.1, 601.1 & 701.1.
 ****NEW REVISION FOR SHT P-3 CORRECTED THE SANITARY
 RISER DIAGRAM, BUT NOT THE WATER ISOMETRIC RISER
 DIAGRAM. THERE ARE TWO WATER CLOSETS AND TWO SHOWERS
 SHOWN ON THE REISER DIAGRAM, BUT ONLY ONE WATER CLOSET
 AND ONE SHOWER SHOWN ON THE FLOOR PLAN ON THE WATER
 RISER DIAGRAM. PLEASE CORRELATE.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2009-04-23 Cont ID  
Sent By dwise Date 2009-04-23 Time 20:50 Rev Time 0.00
Received By dwise Date 2009-04-23 Time 20:50 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2009-04-08 Cont ID  
Sent By kstevens Date 2009-04-08 Time 16:44 Rev Time 0.00
Received By kstevens Date 2009-04-08 Time 16:44 Sent To  
Notes
2009-04-08 16:50:32DENIED
 REFERENCE:
 FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. SHT P-3 THE SANITARY RISER DIAGRAM AND THE WATER
 RISER DIAGRAM DO NOT REFLECT THE CHANGES INDICATED ON
 SHT P-2 FOR THE BATHROOM CHANGES SUBMITTED THIS
 REVISION. SECTIONS 106.1.1, 601.1 & 701.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2009-04-08 Cont ID  
Sent By kstevens Date 2009-04-08 Time 16:43 Rev Time 0.00
Received By kstevens Date 2009-04-08 Time 16:43 Sent To  
Notes
2009-04-08 16:44:26REVISIONS OK -- SHTS P-1 & P-2.

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-08-07 Cont ID  
Sent By mperson Date 2008-08-07 Time 09:30 Rev Time 0.00
Received By mperson Date 2008-08-07 Time 09:30 Sent To G
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-04-30 Cont ID  
Sent By mperson Date 2008-04-30 Time 08:38 Rev Time 0.00
Received By mperson Date 2008-04-30 Time 08:38 Sent To G
Notes
2008-04-30 08:55:33PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET P-3 WATER ISOMETRIC: A WATER-HAMMER ARRESTOR
 IS REQUIRED FOR THE 1/2" HOT WATER SUPPLY TO THE
 DISHWASHER. PER FBC-2004 PLUMBING SECTION 604.9.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 4 Status P Date 2009-02-26 Cont ID  
Sent By mcruz Date 2009-02-26 Time 12:32 Rev Time 0.00
Received By mcruz Date 2009-02-26 Time 12:32 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2008-10-27 Cont ID  
Sent By mcruz Date 2008-10-27 Time 11:55 Rev Time 0.00
Received By mcruz Date 2008-10-27 Time 11:55 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2008-08-04 Cont ID  
Sent By mcruz Date 2008-08-04 Time 09:33 Rev Time 0.00
Received By rkussner Date 2008-09-22 Time 14:11 Sent To E
Notes
2008-08-04 09:31:05**ZONING FAILED 1ST RESUB **
  
 1.PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2.REPEAT COMMENT - PURSUANT TO SECTION 94-441(C)(2)
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS):
 AS THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE
 STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH
 THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING
 SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS
 FOUND IN ARTICLE XIV OF THE ZLDRS.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDRS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR
 [email protected]
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT

Review Stop Z ZONING
Rev No 1 Status F Date 2008-04-25 Cont ID  
Sent By choops Date 2008-04-25 Time 15:54 Rev Time 0.00
Received By choops Date 2008-04-25 Time 15:54 Sent To M
Notes
2008-04-25 16:02:11***FAILED***
  
  
 1)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDRS.PLEASE SUBMIT A LANDSCAPE PLAN SHOWING
 COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE
 ZLDRS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "M" - SF RACK