| Plan Review Stops For Permit 08040678 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2009-04-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-04-24 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-04-24 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2009-04-24 10:34:33 | RE-STAMP STAIRS REVISION BECAUSE IT WAS MISPLACED. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2009-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-04-08 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-04-08 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2009-04-08 10:29:13 | STAIRS REVISION. OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2009-03-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-03-16 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-03-16 |
Time |
16:37 |
Sent To |
PC |
|
| Notes |
| 2009-03-16 16:42:19 | BUILDING SUBMITTAL CHECKLIST. | | | | | | 1- ALL ITEMS REQUESTED ON PROVISO ARE ADDRESSED EXCEPT | | | THE STAIRS RATIO REQUIRED BY SEC. R311.5.3.2 OF 2004 | | | FLORIDA RESIDENTIAL CODE. THE SUM OF 2 RISERS AND 1 | | | TREAD MUST BE BETWEEN 24 AND 25. THE TREAD'S NOSING | | | CAN'T BE CONSIDERED FOR THE SIZE OF THE TREAD. SEE | | | ATTACHED DRAWING FROM THE COMMENTARY BOOK WHICH | | | EXPLAINS HOW TO DIMENSION THE STAIRS TO GET PROPER | | | RATIO. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2009-03-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-03-05 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-03-05 |
Time |
15:28 |
Sent To |
PC |
|
| Notes |
| 2009-03-05 15:30:21 | SKYLIGHT REVISION CHECKLIST: | | | | | | 1- SKYLIGHT INFORMATION SUBMITTED FL3130-R3 IS A | | | REVISION, NOT A SUBMITTAL. PRODUCT APPROVAL FOR | | | SKYLIGHT WAS ALREADY APPROVED. IT WAS NOA 07-0810.02. | | | THEREFORE, OWES $80.00 FOR REVISION FEES. | | | | | | 2- PRODUCT APPROVAL FL3130-R3 SUBMITTED DOESN'T MEET | | | THE DESIGN PRESSURES CALCULATED BY THE ARCHITECT. | | | | | | 3- ACCORDING TO HALLMARK CERTIFICATE OF CONFORMANCE AND | | | LICENSE SHEET (CCL) THE PRODUCT APPROVAL IS EXPIRED. | | | NEED TO PROVIDE INFORMATION FOR CURRENT PRODUCT | | | APPROVAL. | | | | | | 4- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT | | | SIGNING AND SEALING) PRODUCT APPROVAL PRIOR TO | | | SUBMITTAL TO THIS OFFICE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2009-02-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-02-18 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-02-18 |
Time |
17:06 |
Sent To |
Z |
|
| Notes |
| 2009-02-18 17:59:12 | BUILDING REVIEW CHECKLIST FOR ITEMS REQUESTED ON | | | PROVISO DATED 08/07/08: | | | | | | | | | ***NOTE: PROVISO WAS ISSUED TO ALLOW CONSTRUCTION TO | | | PROCEED AND AVOID CONFLICTS OR DELAYS. AS OF NOW | | | PROVISO INFORMATION IS STILL NOT SUBMITTED. | | | | | | | | | 1- THIS ITEM WAS ADDRESSED. | | | | | | 2- THIS ITEM WAS NOT ADDRESSED: | | | RAS 117 CALCULATIONS FOR WATERPROOFING SYSTEM NEED TO | | | BE SIGNED AND SEALED AS REQUIRED BY GENERAL LIMITATION | | | #7. | | | ***NO INFORMATION SUBMITTED. NEED COMPLETE PRODUCT | | | APPROVAL ALONG WITH THE RAS 117 CALCULATIONS. NO | | | INFORMATION SUBMITTED. | | | | | | 3- NEED TO PROVIDE ELEVATION CERTIFICATE FOR ENTIRE | | | BUILDING AS REQUIRED BY CITY ORDINANCE SEC. | | | 94-546(B)(1). MIN. FINISH FLOOR ELEVATION TO BE 7.5' | | | SINCE BASE FLOOD ELEVATION IS 7.0'. | | | ***NOTE: THIS IS TO BE PROVIDED LATER ON TO THE | | | BUILDING INSPECTOR PRIOR TO C.O.. | | | | | | 4- THIS ITEM WAS NOT ADDRESSED: | | | REVISE ENERGY CALCULATIONS TO INCLUDE THE SQUARE | | | FOOTAGE FOR NEW STAIRWAY. | | | ***NO INFORMATION SUBMITTED. | | | | | | 5- REVISE STAIR CALCULATIONS TO COMPLY WITH RATIO OF | | | SEC. R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE. | | | ***INFORMATION SUBMITTED ON SHEET A-7 DOESN'T COMPLY | | | WITH THE RISER/TREAD RATIO. 6-11/16" RISERS AND 9-1/2" | | | TREADS DON'T COMPLY WITH THE 2R+1T RATIO. REVIEW THE | | | ABOVE MENTIONED SECTION AND REVISE AS REQUIRED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2009-01-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-01-30 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-01-30 |
Time |
13:02 |
Sent To |
PC |
|
| Notes |
| 2009-01-30 13:20:05 | BUILDING REVISION CHECKLIST: | | | | | | 1- COMMENTS ON THE REVISION SUBMITTAL FORM ONLY | | | SPECIFIES REVISION OF STRAPPING AND BOLTING OF BEAMS. | | | PLANS SUBMITTED SHOWS NOT ONLY STRAPPING AND BOLTING | | | REVISION BUT FLOOR PLANS REVISIONS AS WELL. WEST | | | ELEVATION WAS CHANGED ALSO. THEREFORE, NEED TO BRING | | | PLANS TO HISTORIC TO GET APPROVAL STAMP. | | | | | | 2- SHEET S-1: | | | A) CONNECTOR MTS18 SPECIFIED ON DETAIL 4/S-1 IS NOT A | | | JOIST HANGER CONNECTOR. THIS CONNECTOR CAN'T BE USED AS | | | A JOIST HANGER. SEE SIMPSON CATALOG FOR PROPER TYPE OF | | | HANGER TO BE USED AND REVISE AS REQUIRED. ALSO, REVISE | | | HANGERS SPECIFIED ON SECOND FLOOR FRAMING PLAN AS | | | REQUIRED TO MATCH REVISED DETAIL 4/S-1. | | | | | | B) CLARIFY WHAT KIND OF CONNECTOR IS JUS210 SPECIFIED | | | SECOND FLOOR FRAMING PLAN ON BEAM BY MASTER BEDROOM | | | AREA. | | | | | | 3- NEW REVISED FLOOR FRAMING PLANS SHOW NEW AREAS TO | | | HAVE NEW FRAMING. UPDATE VALUE TO INCLUDE THE | | | ADDITIONAL WORK AS REQUIRED BY SEC. 108.3 CITY | | | AMENDMENTS TO FBC 2004. PERMIT FEES WILL BE ADJUSTED | | | ACCORDINGLY. | | | | | | 4- PROVIDE INFORMATION REQUESTED ON PROVISO DATED | | | 08/07/08. SEE ATTACHED COPY. PROVIDE REQUIRED | | | INFORMATION TO AVOID CONFLICT OR DELAYS IN THE | | | CONSTRUCTION PROCESS. | | | | | | 5- NUMBER OF REVISED PAGES ARE 10, NOT 4 AS SPECIFIED | | | ON REVISION SUBMITTAL FORM. THEREFORE OWES $180 FOR | | | REVISION FEES. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-10-31 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-10-31 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2008-10-31 13:58:09 | PLANS REVIEWED FOR IMPACT FEES STAMP TO PASS BUILDING | | | STOP. PLANS APPROVED WITH PROVISO DATED 8-7-08. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
2008-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-08-07 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-08-07 |
Time |
16:23 |
Sent To |
PC |
|
| Notes |
| 2008-08-08 11:09:49 | BUILDING REVIEW APPROVED WITH PROVISO. | | | 1- REVISE AREA CALCULATIONS. | | | 2- RAS 117 CALCULATIONS FOR WATERPROOFING SYSTEM NEED | | | TO BE SIGNED AND SEALED AS REQUIRED BY GENERAL | | | LIMITATION #7. | | | 3- NEED TO PROVIDE ELEVATION CERTIFICATE FOR ENTIRE | | | BUILDING AS REQUIRED BY CITY ORDINANCE SEC. | | | 94-546(B)(1). MIN. FINISH FLOOR ELEVATION TO BE 7.5' | | | SINCE BASE FLOOD ELEVATION IS 7.0'. | | | 4- REVISE ENERGY CALCULATIONS. | | | 5- REVISE STAIR CALCULATIONS TO COMPLY WITH RATIO OF | | | SEC. R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-05-05 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-05-05 |
Time |
07:48 |
Sent To |
M |
|
| Notes |
| 2008-05-05 16:23:15 | RESIDENTIAL (R3) ADDITION AND ALTERATION, BUILDING | | | REVIEW CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | | | | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD | | | (561)233-5120)TO CHECK IF IMPACT FEES ARE DUE. BRING | | | BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE | | | DUE. | | | | | | 3- AREA CALCULATIONS ON SHEET SP-1 NEED TO SPECIFY | | | ADDITION AREAS INCLUDING THE NEW STAIRWAY AND ADDITION | | | FOR NEW GUEST ROOM TO PROPERLY ASSESS THE RADON FEES. | | | | | | 4- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) ROOF TILE. | | | B) POLYFOAM IF USED FOR ROOF TILE. | | | C) * FLAT ROOF APPROVED ASSEMBLY ON PAGE 4 OF NOA | | | 07-0212.03 IS FOR AN INSULATED ASSEMBLY. PLANS DON'T | | | SHOW AN INSULATED ASSEMBLY. CLARIFY/REVISE AS | | | REQUIRED. | | | ** PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | | PERIMETER AND CORNER AREASAS REQUIRED BY GENERAL | | | LIMITATION #7. | | | ***NOTE: THIS SYSTEM WILL REQUIRE AT LEAST 4 ROWS IN | | | THE FIELD AREA OF THE ROLL. SEE ATTACHED CALCULATIONS. | | | 3" SPACING IS NOT ALLOWED. | | | D) FRENCH DOORS THAT RESIST THE DESIGN PRESSURES | | | CALCULATED ON SHEET S-3 FOR D2 DOORS. | | | E) SKYLIGHT ABOVE STAIRWAY. | | | | | | 5- ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND | | | APPROVED IN WRITING (NOT SIGNING AND SEALING).PRODUCT | | | APPROVALS SUBMITTED HAVE THE REVIEW STAMP, BUT THEY | | | WERE NOT SIGNED. ONLY THE DATE WAS PROVIDED. | | | | | | 6- ENERGY CALCULATIONS: | | | A) COMPLETE ALL THE INFORMATION ON TOP OF FORM. | | | | | | B ) SPECIFY HOW IS THE R6.0 INSULATION INSTALLED ON | | | THE CONCRETE SLAB. SEE ITEM #8(A). | | | C) NEED TO ADD THE AREA FOR THE ADDITION BY NEW | | | GUEST ROOM.ALSO,WINDOWS AND DOORSON THE GUEST | | | ROOM NEED TO BE INCLUDED ON THE SECOND PAGE. | | | D) COMPLETE THE CODE COMPLIANCE CHECKLIST. | | | | | | ***NOTE: SHORT FORM 600C-04R IS THE MOST ADEQUATE FORM | | | TO BE USED FOR THIS PROJECT INSTEAD OF THE 600A-04R | | | FORM SUBMITTED. | | | | | | 7- ELEVATION CERTIFICATE NEED TO HAVE SURVEYORS | | | ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 472 | | | FLORIDA STATUTE.THISCERTIFICATE WILL BE REQUIRED AT | | | THE END OF THE CONSTRUCTION TO GET THE C.O. | | | | | | 8- DOOR #11 SPECIFIED FOR NEW GUEST BATHROOM IN THE | | | DOOR SCHEDULEDOESN'T MATCHDOOR SHOWN ON FIRST FLOOR | | | PLAN. REVISE AS REQUIRED. | | | | | | 9- PROVIDE SPECIFICATIONS FOR ICYNENE INSULATION TO | | | VERIFY COMPLIANCE WITHENERGY CALCULATIONS AND PLAN | | | SPECIFICATIONS. | | | | | | 10- SHEET A-7:A) REVISE STAIR CALCULATIONS TO COMPLY | | | WITH SEC. R311.5.3.2 OF 2004 FLORIDA RESIDENTIAL CODE. | | | NEED RISER AND TREAD RATIO BETWEEN 24 AND 25. | | | B) REVISE RAILING DETAILTO COORDINATE WITH RISER | | | AND TREAD DIMENSIONS SHOWN ON SECTION A-STAIR DETAIL | | | AND FLOOR PLANS. ALSO, COORDINATE WITH ITEM #7(A) | | | ABOVE. | | | | | | 11- SHEET S-1: A) SPECIFY CONNECTORS AT THE ENDS OF NEW | | | BEAMS WHERE OLD STAIRS WERE DEMOLISHED. | | | B) DETAIL 3/S-1: SPECIFY SIZE OF REBAR CONNECTING | | | EXISTING FOOTING TO NEW FOOTING. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-05 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-05 |
Time |
13:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-25 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-25 |
Time |
07:07 |
Sent To |
Z |
|
| Notes |
| 2008-04-25 12:05:30 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, 2004 | | | FBC CHAPTER 1 AS AMENDED AND FOUND NONCOMPLIANT WITH | | | THE FOLLOWING: | | | | | | 1} REGARDING THE MAIN HOUSE DISCONNECT , SHEET E-3, A | | | GROUNDING ELECTRODE CONDUCTOR IS REQUIRED AT THE | | | SEPARATE STRUCTURE PER 250.32, SIZED PER 250.66. | | | | | | 2} CIRCUIT B-3 LISTED AS THE LAUNDRY CIRCUIT IS IN | | | VIOLATION OF 210.11(C)(2) "THIS CIRCUIT SHALL HAVE NO | | | OTHER OUTLETS." THE LIGHTS CANNOT BE ON THE CIRCUIT. | | | | | | 3} THE DRYER LISTED ON CIRCUIT 4-6 PANEL "B" APPEARS TO | | | BE A STACK UNIT ON SHEET E-1, CLARIFY AND CORRECT | | | SCHEDULE "B" ACCORDINGLY. | | | | | | 4} LOCATE BOTH AHU'S ON THE PLAN.106.1.1 FBC. | | | | | | 5} BATH CIRCUIT B-5 DOES NOT COMPLY WITH 210.11(C)(3) | | | "SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS." THE | | | RECEPTACLE IN THE "POWDER" AND BATH" ROOM, SHEET E-1 | | | COULD BE ON THAT CIRCUIT, BUT NOT THE LIGHTS.OR THE | | | LIGHTS AND RECEPTACLE IN EITHER ONE COULD BE ON THAT | | | CIRCUIT. SEE EXCEPTION: WHERE THE 20-AMPERE CIRCUIT | | | SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT | | | WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE | | | SUPPLIED IN ACCORDANCE WITH 210.23(A)(1) AND (A)(2). | | | | | | 6} CIRCUIT B7 INDICATES IT SERVES THE HALL AS WELL AS | | | THE BEDROOM. SHEET E-1 INDICATES CIRCUIT B12 IN THE | | | HALL, CORRELATE THE CIRCUITS. | | | | | | 210.52(E) OUTDOOR OUTLETS FOR A ONE-FAMILY DWELLING AND | | | EACH UNIT OF A TWO-FAMILY DWELLING THAT IS AT GRADE | | | LEVEL, AT LEAST ONE RECEPTACLE OUTLET ACCESSIBLE AT | | | GRADE LEVEL AND NOT MORE THAN 2.0 M (6 1/ 2 FT) ABOVE | | | GRADE SHALL BE INSTALLED AT THE FRONT AND BACK OF THE | | | DWELLING. | | | | | | NOTE: CONFIRM THE AHU LOADS ARE 4800 WATTS TOTAL HEAT | | | FOR 2855 SQ FT RESIDENCE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2009-02-24 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2009-02-24 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2009-02-24 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2009-02-24 15:31:54 | REVISION OK |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2008-08-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-07 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-07 |
Time |
09:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-30 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-30 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
| 2008-04-30 09:02:48 | GAS PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET P-3 GAS DISTRIBUTION ISOMETRIC: THE GAS | | | PIPING TO THE TANKLESS WATER HEATER NEEDS TO BE | | | INCREASED TO 1". PER FBC-2004 FUEL GAS TABLES 402.4(2) | | | AND 402.4 (20). PLEASE REFERENCE THE ATTACHED TABLES TO | | | THESE COMMENTS INDICATING THIS FOR THE RESUBMITTAL. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2009-02-17 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2009-02-17 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2009-02-17 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2009-02-17 15:24:52 | HISTORIC FOR REV DATED 2/17/09 APPROVED BY FMITTNER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2009-04-17 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2009-04-17 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2009-04-17 |
Time |
11:30 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2009-04-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-07 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-07 |
Time |
10:05 |
Sent To |
L |
|
| Notes |
| 2009-04-07 10:06:30 | TO "Z" BOX/REV (FOR LANDSCAPING) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2009-04-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-06 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-06 |
Time |
13:16 |
Sent To |
P |
|
| Notes |
| 2009-04-06 13:16:58 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2009-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-30 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-30 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2009-03-30 16:46:39 | TO "R6" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2009-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-03-03 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-03-03 |
Time |
16:19 |
Sent To |
B |
|
| Notes |
| 2009-03-03 16:19:34 | TO "JGOMEZ" DES/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2009-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-27 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-27 |
Time |
09:06 |
Sent To |
B |
|
| Notes |
| 2009-02-27 09:07:12 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2009-02-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-18 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-18 |
Time |
10:56 |
Sent To |
B |
|
| Notes |
| 2009-02-18 10:57:00 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-02-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-12 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-12 |
Time |
15:24 |
Sent To |
G |
|
| Notes |
| 2009-02-12 15:27:16 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-01-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-29 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-29 |
Time |
11:32 |
Sent To |
B |
|
| Notes |
| 2009-01-29 11:32:33 | TO "JGOMEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-19 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-19 |
Time |
09:35 |
Sent To |
M |
|
| Notes |
| 2008-12-19 09:38:10 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-12 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-12 |
Time |
15:34 |
Sent To |
Z |
|
| Notes |
| 2008-09-12 15:34:54 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-29 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-29 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2008-07-29 08:50:41 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-05-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-05-07 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-04-24 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2008-04-24 16:49:33 | TO "SFR" "Z" |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2009-04-09 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-04-09 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-04-09 |
Time |
12:18 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2008-11-04 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-11-04 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-11-04 |
Time |
13:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-09-22 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-09-22 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-09-22 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2008-09-22 14:38:19 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. THE LANDSCAPE PLAN SHALL BE DRAWN TO SCALE. PLEASE | | | DRAW THE LANDSCAPE PLAN AT THE SAME SCALE AS THE SITE | | | PLAN. THE EXISTING LANDSCAPE PLAN IS NOT CONSISTENT | | | WITH THE SITE PLAN REGARDING THE HARDSCAPE AND | | | STRUCTURES. | | | | | | 2. SHOW ALL STREETS, UTILITIES, EASEMENTS, EXISTING | | | TREES ON NEIGHBORING PROPERTY IN CLOSE PROXIMITY TO THE | | | PROPERTY LINE THAT MAY IMPEDE THE GROWTH OF PROPOSED | | | TREES, TRASH/GARBAGE AREAS WITH SCREENING, GROUND LEVEL | | | AIR CONDITIONING UNITS AND OTHER MECHANICAL EQUIPMENT | | | WITH SCREENING AND ANYTHING ELSE THAT MAY INTERFERE | | | WITH THE PROPOSED LANDSCAPING. | | | | | | 3. PROVIDE ALL REQUIRED LANDSCAPE CALCULATIONS BASED | | | UPON ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 4. PROVIDE A LANDSCAPE PLANT LIST WITH ALL PROPOSED | | | PLANT MATERIAL, SIZE (NOT CONTAINER SIZE) AND SPACING. | | | | | | 5. PROVIDE SOD AND IRRIGATION IN THE RIGHTS-OF-WAY. | | | | | | 6. SHOW THE VISIBILITY TRIANGLE. | | | | | | 7. TREES CANNOT BE PLANTED IN THE RIGHT-OF-WAY WITHOUT | | | APPROVAL OF THE ENGINEERING DEPARTMENT. | | | | | | 8. IDENTIFY ALL EXISTING TREES ON SITE. IF ANY TREES | | | WILL BE REMOVED, A TREE ALTERATION PERMIT APPLICATION | | | SHALL BE REQUIRED. | | | | | | 9. NO SHADE TREES HAVE BEEN PROPOSED. ONE SHADE OR | | | FLOWERING TREE SHALL BE PLANTED FOR EACH 1200 SQUARE | | | FEET OF OPEN SPACE. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-12-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-20 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-20 |
Time |
14:36 |
Sent To |
PC |
|
| Notes |
| 2008-12-20 14:39:47 | REVIEW #: REVISION 1 | | | ACTION: DENOED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE PERMIT RECORD SET OF PLANS WERE PREPARED, SIGNED | | | AND SEALED BY AN ARCHITECT. RAFAEL RODRIGUEZ IS THE | | | DESIGNER OF RECORD FOR THIS PERMIT. PLANS MAY ONLY BE | | | REVISED BY THE DESIGNER OF RECORD IN ACCORDANCE WITH | | | F.S. 481 AND FBCB 106.1.3. PROVIDE REVISIONS WHICH WERE | | | PREPARED, SIGNED AND SEALED BY THE DESIGNER OF RECORD | | | IN ORDER TO BE REVIEWED FOR CODE COMPLIANCE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-06 |
Time |
09:12 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-08-06 |
Time |
09:12 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-05-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-06 |
Time |
13:21 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2008-05-06 |
Time |
13:21 |
Sent To |
B |
|
| Notes |
| 2008-04-28 10:48:21 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE ENERGY CALCULATIONS FORM 600A-2004R MAY NOT BE | | | USED FOR A RENOVATION, PLEASE SUBMIT FORM 600C-04R PER | | | 2004 FBC 13-101.2.3. | | | | | | 2) PLEASE PROVIDE FOR RETURN AIR TO THE NEW OFFICE ON | | | THE FIRST FLOOR, PER 2004 FBC/R M1602.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2009-05-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-05-04 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-05-04 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2009-05-04 15:51:16 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | | | 1. SHT P-3 THE SANITARY RISER DIAGRAM AND THE WATER | | | RISER DIAGRAM DO NOT REFLECT THE CHANGES INDICATED ON | | | SHT P-2 FOR THE BATHROOM CHANGES SUBMITTED THIS | | | REVISION. SECTIONS 106.1.1, 601.1 & 701.1. | | | ****NEW REVISION FOR SHT P-3 CORRECTED THE SANITARY | | | RISER DIAGRAM, BUT NOT THE WATER ISOMETRIC RISER | | | DIAGRAM. THERE ARE TWO WATER CLOSETS AND TWO SHOWERS | | | SHOWN ON THE REISER DIAGRAM, BUT ONLY ONE WATER CLOSET | | | AND ONE SHOWER SHOWN ON THE FLOOR PLAN ON THE WATER | | | RISER DIAGRAM. PLEASE CORRELATE. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2009-04-23 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2009-04-23 |
Time |
20:50 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2009-04-23 |
Time |
20:50 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2009-04-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-04-08 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-04-08 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2009-04-08 16:50:32 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P-3 THE SANITARY RISER DIAGRAM AND THE WATER | | | RISER DIAGRAM DO NOT REFLECT THE CHANGES INDICATED ON | | | SHT P-2 FOR THE BATHROOM CHANGES SUBMITTED THIS | | | REVISION. SECTIONS 106.1.1, 601.1 & 701.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-04-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-04-08 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-04-08 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2009-04-08 16:44:26 | REVISIONS OK -- SHTS P-1 & P-2. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-08-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-07 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-07 |
Time |
09:30 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-30 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-30 |
Time |
08:38 |
Sent To |
G |
|
| Notes |
| 2008-04-30 08:55:33 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET P-3 WATER ISOMETRIC: A WATER-HAMMER ARRESTOR | | | IS REQUIRED FOR THE 1/2" HOT WATER SUPPLY TO THE | | | DISHWASHER. PER FBC-2004 PLUMBING SECTION 604.9. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2009-02-26 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-02-26 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-02-26 |
Time |
12:32 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-10-27 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-10-27 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2008-10-27 |
Time |
11:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2008-08-04 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-09-22 |
Time |
14:11 |
Sent To |
E |
|
| Notes |
| 2008-08-04 09:31:05 | **ZONING FAILED 1ST RESUB ** | | | | | | 1.PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2.REPEAT COMMENT - PURSUANT TO SECTION 94-441(C)(2) | | | OF THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS): | | | AS THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF THE | | | STRUCTURE'S VALUE (LISTED AS "IMPROVEMENT VALUE" WITH | | | THE P.B.C. PROPERTY APPRAISER'S OFFICE), LANDSCAPING | | | SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS | | | FOUND IN ARTICLE XIV OF THE ZLDRS. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDRS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME AT:(561) 822-1444 OR (561) 805-6720 OR | | | [email protected] | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-25 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-25 |
Time |
15:54 |
Sent To |
M |
|
| Notes |
| 2008-04-25 16:02:11 | ***FAILED*** | | | | | | | | | 1)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDRS.PLEASE SUBMIT A LANDSCAPE PLAN SHOWING | | | COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE | | | ZLDRS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | | | | SENT TO "M" - SF RACK |
|
|