Plan Review Details - Permit 08040667
| Plan Review Stops For Permit 08040667 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-11-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-17 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-17 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-08-18 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-18 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2008-08-18 10:13:10 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST: | | | | | | 1.ADDRESSED. | | | | | | 2.THE INSTALLATION SCHEDULE SHUTTER CONNECTION | | | MOUNTING TYPE IS TO CORRELATE WITH THE ANCHOR SCHEDULE. | | | YOU'VE CIRCED ANCHORING FOR BOTTOM 8.SPECIFY BOTH TOP | | | AND BOTTOM ANCHOR CONNECTION TYPE ON THE INSTALLATION | | | SCHEDULE FORM. | | | | | | 2ND REVIEW, PLEASE REVISE SHUTTER CONNECTION MOUNTING | | | TYPE TO CORRELATE WITH THE ANCHORS SCHEDULES.FOR THE | | | ACCORDIONS, THIS SHOULD BE C1 THROUGH C5.FOR THE | | | PANELS, WALL MOUNT 1 THROUGH 13.PLEASE NOTE THAT | | | OPENING 1 SPECIFIES TAPCONS, BUT CIRCLED ANCHOR SPACING | | | FOR SOLID SET FOR BOTTOM 8 (TAPCONS NOT PERMITTED FOR | | | THAT SPAN, SHUTTER CONNECTION MOUNTING TYPE). | | | | | | 3RD REVIEW, INSTALLATION SCHEDULE STATES WALL.THERE | | | ARE DIFFERENT TYPES OF WALL MOUNT, EACH WITH DIFFERENT | | | ANCHOR SPACING REQUIREMENTS.PLEASE REVISE AS | | | REQUESTED. | | | | | | 3.ADDRESSED. | | | | | | 4.THE SPAN IS ONE DIMENSION.PLEASE REVISE.THIS IS | | | THE DISTANCE ANCHOR TO ANCHOR OR BLADE LENGTH, | | | DEPENDING ON TYPE OF SHUTTER. | | | | | | 2ND REVIEW, THIS WAS NOT ADDRESSED BUT AS VERTICAL WAS | | | SPECIFIED, I USED THAT DIMENSION FOR THE REVIEW. | | | | | | 3RD REVIEW, NOT ADDRESSED.PLEASE SPECIFY SPAN. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-04 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-04 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2008-06-04 15:59:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST: | | | | | | 1.ADDRESSED. | | | | | | 2.THE INSTALLATION SCHEDULE SHUTTER CONNECTION | | | MOUNTING TYPE IS TO CORRELATE WITH THE ANCHOR SCHEDULE. | | | YOU'VE CIRCED ANCHORING FOR BOTTOM 8.SPECIFY BOTH TOP | | | AND BOTTOM ANCHOR CONNECTION TYPE ON THE INSTALLATION | | | SCHEDULE FORM. | | | | | | 2ND REVIEW, PLEASE REVISE SHUTTER CONNECTION MOUNTING | | | TYPE TO CORRELATE WITH THE ANCHORS SCHEDULES.FOR THE | | | ACCORDIONS, THIS SHOULD BE C1 THROUGH C5.FOR THE | | | PANELS, WALL MOUNT 1 THROUGH 13.PLEASE NOTE THAT | | | OPENING 1 SPECIFIES TAPCONS, BUT CIRCLED ANCHOR SPACING | | | FOR SOLID SET FOR BOTTOM 8 (TAPCONS NOT PERMITTED FOR | | | THAT SPAN, SHUTTER CONNECTION MOUNTING TYPE). | | | | | | 3.ADDRESSED. | | | | | | 4.THE SPAN IS ONE DIMENSION.PLEASE REVISE.THIS IS | | | THE DISTANCE ANCHOR TO ANCHOR OR BLADE LENGTH, | | | DEPENDING ON TYPE OF SHUTTER. | | | | | | 2ND REVIEW, THIS WAS NOT ADDRESSED BUT AS VERTICAL WAS | | | SPECIFIED, I USED THAT DIMENSION FOR THE REVIEW. | | | | | | NEW COMMENTS: | | | | | | 5.1 3/4" TAPCONS SPECIFIED.THIS IS THE EMBEDMENT | | | REQUIREMENT; A LONGER TAPCON IS REQUIRED TO MEET THE | | | EMBEDMENT REQUIREMENT (STUCCO, SHUTTER TRACK). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-28 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-28 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2008-04-28 11:55:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.THE COPY OF THE INSTALLATION SCHEDULE IS NOT | | | COMPLETE, OPENING NUMBERS ARE CUT OFF.PLEASE PROVIDE | | | A CLEAR COPY. | | | | | | 2.THE INSTALLATION SCHEDULE SHUTTER CONNECTION | | | MOUNTING TYPE IS TO CORRELATE WITH THE ANCHOR SCHEDULE. | | | YOU'VE CIRCED ANCHORING FOR BOTTOM 8.SPECIFY BOTH TOP | | | AND BOTTOM ANCHOR CONNECTION TYPE ON THE INSTALLATION | | | SCHEDULE FORM. | | | | | | 3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | | FAC9B72.UNSEALED ENGINEERING WAS PROVIDED WITHOUT THE | | | STATE PRODUCT APPROVAL. | | | | | | 4.THE SPAN IS ONE DIMENSION.PLEASE REVISE.THIS IS | | | THE DISTANCE ANCHOR TO ANCHOR OR BLADE LENGTH, | | | DEPENDING ON TYPE OF SHUTTER. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-31 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-31 |
Time |
15:53 |
Sent To |
B |
|
| Notes |
| 2008-10-31 15:54:11 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-08 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-08 |
Time |
13:43 |
Sent To |
B |
|
| Notes |
| 2008-08-08 13:44:03 | TO "SHILL" DESK/REUSB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-30 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-30 |
Time |
11:22 |
Sent To |
B |
|
| Notes |
| 2008-05-30 11:23:57 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-28 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-24 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2008-04-24 15:59:44 | TO "MISC" BOX#1 |
|
|
|