| Plan Review Stops For Permit 08040631 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-16 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-16 |
Time |
12:47 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-02 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-30 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-05-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-03 |
Time |
05:50 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-02 |
Time |
18:06 |
Sent To |
PC |
|
| Notes |
| 2008-05-03 05:50:00 | BUILDING PLAN REVIEW5-2-08 | | | PERMIT: 08040631 | | | ADD: 2581 METROCENTRE BLVD | | | CONT: SISCA CONSTRUCTION SERVICES, LLC | | | TEL: (561)686-5545 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 2 ) INFORMATIONAL FL S S 713.13NOTICE OF | | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 4)FBC 1210.2 WALLS WITHIN 2 FEET OF URINALS AND WATER | | | CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT | | | SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR. EPOXY | | | PAINT ON DRYWALL DOES NOT MEET THIS REQUIREMENT. | | | | | | 5)IF THE BUILDING HAS A FIRE SPRINKLER SYSTEM, SHOW | | | THE LAYOUT OF THE SPRINKLER HEADS IN RELATION TO THE | | | RENOVATION OF THE BUILDING.THIS INFORMATION CAN BE | | | SHOWN ON THE CEILING PLANS. FBC 106.3.5.1.1(5) AND FS | | | 553.79(2). | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-28 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-28 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-09 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-09 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2008-06-09 15:38:37 | NEW SHEET A.1 STAMPED, DATED AND SIGNED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-06-03 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-06-03 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2008-06-03 13:30:08 | *****APPROVED***** | | | | | | PLAN SHEETSA.1, A.2, AND E.2 WERE STAMPED, INTIALED, | | | AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-30 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-30 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2008-04-30 14:34:53 | ***DENIED*** | | | | | | 1) PLANS APPEAR TO BE CODE COMPLIANT. PROJECT DATA | | | INDICATES THAT THE BUILDING IS PROTECTED BY AN | | | AUTOMATIC FIRE SPRINKLER SYSTEM, HOWEVER SPRINKLER | | | NOTES SHOW NOT APPLICABLE. IF FIRE SPRINKLER SYSTEM IS | | | PROVIDED, PLEASE SHOW SPRINKLER LAYOUT. ADDITIONALLY, | | | SEPARATE SHOP DRAWINGS AND PERMIT ARE REQUIRED FOR | | | REMODEL. IF SPRINKLER SYSTEM IS NOT PART OF THIS | | | PROJECT, PLEASE REMOVE REFERENCE FROM PROJECT DATA. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-09 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-09 |
Time |
09:53 |
Sent To |
P |
|
| Notes |
| 2008-06-09 09:54:19 | TO "BOB"#7 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-29 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-29 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2008-05-29 10:42:30 | TO "BOB"#1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-05-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-24 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2008-04-24 11:01:30 | TO "BOB"#16 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-25 |
Time |
11:50 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-25 |
Time |
11:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-09 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-09 |
Time |
14:19 |
Sent To |
I |
|
| Notes |
| 2008-06-09 14:31:49 | NOTE: NEW A.1 SHEET SUBMITTED THAT NEEDS FIRE AND BLDG | | | REVIEW, THIS NEEDS TO BE ON"BOB BOARD". |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-03 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-03 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2008-06-03 11:30:26 | PLUMBING PLAN REVIEW: | | | DENIED **2ND TIME: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | THE PREVIOUS PLUMBING REVIEW COMMENTS AS WELL AS THE | | | DESIGNER'S RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. SHEET P.1 SANITARY RISER DIAGRAM AND PLUMBING PLAN: | | | FIXTURE SK-1 MUST DRAIN DOWNSTREAM OF THE WET VENTED | | | BATHROOM GROUP IN ROOM #103. PER FBC-2004 PLUMBING | | | SECTION 909.1 WET VENT PERMITTED. | | | | | | **RESPONSE NOTED, HOWEVER THE RESUBMITTED SHEET P.1 | | | STILL INDICATES FIXTURE SK-1 DRAINING INTO THE WET | | | VENTED BATHROOM GROUP (WATER CLOSET AND LAVATORY) OF | | | RESTROOM #2. FIXTURE SK-1 NEEDS TO DRAIN DOWNSTREAM OF | | | THE WET VENTED BATHROOM. PER FBC-2004 PLUMBING SECTION | | | 909.1 WET VENT PERMITTED. | | | | | | 2. SHEET A.1 AND P.1 PLEASE CLARIFY IF SINK SK-1 IS A | | | WORK RELATED SINK OR IS THIS SINK FOR A BREAK AREA? IF | | | THIS SINK IS FOR A BREAK AREA PLEASE PROVIDE THE | | | FOLLOWING PER FBC FLORIDA ACCESSIBILITY CODE CHAPTER 11 | | | SECTIONS 11-4.24.1 THRU 11-4.24.6. WITH AN ELEVATION | | | DETAIL. PER (W.P.B. AS AMENDED) SECTION 106.1.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS AND SECTION | | | 106.1.2 ADDITIONAL DATA. | | | | | | **RESPONSE NOTED, HOWEVER THE RESUBMITTED DETAIL ON | | | SHEET A.1 DETAIL 3/A.1 DOES NOT CLEARLY INDICATE THE | | | FOLLOWING. THE CLEAR FLOOR SPACE NEEDS TO BE INDICATED | | | ON THE FLOOR PLAN ON SHEET A.1. | | | | | | 11-4.24.5 CLEAR FLOOR SPACE. 30" X 48" AND CLEAR FLOOR | | | SPACE SHALL EXTEND A MAXIMUM OF 19" UNDERNEATH THE | | | SINK. | | | 11-4.24.6 EXPOSED PIPES AND SURFACES. INSULATE TO | | | PROTECT AGAINST CONTACT. | | | 11-4.24.7 FAUCETS. LEVER-OPERATED, PUSH-TYPE, OR | | | ELECTRONICALLY CONTROLLED ARE ACCEPTABLE DESIGNS. | | | | | | 3. "OK" COMMENT ADDRESSED. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-29 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-28 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2008-04-28 16:59:32 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET P.1 SANITARY RISER DIAGRAM AND PLUMBING PLAN: | | | FIXTURE SK-1 MUST DRAIN DOWNSTREAM OF THE WET VENTED | | | BATHROOM GROUP IN ROOM #103. PER FBC-2004 PLUMBING | | | SECTION 909.1 WET VENT PERMITTED. | | | | | | 2. SHEET A.1 AND P.1 PLEASE CLARIFY IF SINK SK-1 IS A | | | WORK RELATED SINK OR IS THIS SINK FOR A BREAK AREA? IF | | | THIS SINK IS FOR A BREAK AREA PLEASE PROVIDE THE | | | FOLLOWING PER FBC FLORIDA ACCESSIBILITY CODE CHAPTER 11 | | | SECTIONS 11-4.24.1 THRU 11-4.24.6. WITH AN ELEVATION | | | DETAIL. PER (W.P.B. AS AMENDED) SECTION 106.1.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS AND SECTION | | | 106.1.2 ADDITIONAL DATA. | | | | | | 3. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.1.3, | | | PLUMBING: AN ISOMETRIC POTABLE WATER RISER DIAGRAM IS | | | REQUIRED FOR THE PROPOSED WORK FOR THE COLD WATER | | | INDICATING THE PIPE SIZES, VALVE LOCATIONS, LOCATION OF | | | THE WATER SUPPLY LINE WITH BACKFLOW PREVENTER (CLEARLY | | | INDCATE EXISTING) **608, AND LOCATION OF THE | | | WATER-HAMMER ARRESTORS WHERE QUICK CLOSING VALVES ARE | | | UTILIZED (EXAMPLES=WASHING MACHINES, DISHWASHERS, ICE | | | MAKERS) **604.9. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-24 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-24 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2008-04-24 11:05:47 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|