| Plan Review Stops For Permit 08040612 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-11 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-11 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-05 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-05 |
Time |
06:51 |
Sent To |
|
|
| Notes |
| 2008-05-05 10:29:23 | | | | BUILDING PLAN REVIEW | | | PERMIT: 08040612 | | | ADD: 777 S. FLAGLER DR. WEST 17TH FLOOR | | | CONT: PERILLO CONSTRUCTION | | | TEL: (561)818-7777 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)FBC EXISTING 304.1 LEVEL 2 ALTERATIONS INCLUDE THE | | | RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION | | | OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION | | | OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL | | | EQUIPMENT. THE PLANS INDICATE ALTERATION LEVEL 1; | | | HOWEVER, THE PLANS INDICATE THE REMOVAL OF DOORS AND | | | WALLS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-06-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-20 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-20 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2008-06-20 16:57:59 | ** REDLINED NOTES ** | | | | | | | | | 1) NOTE:BATTERY BACK UP LIGHTING IS REQUIRED FOR | | | MINIMUM 1FT CANDLE FOR EGRESS IN HALLWAYS AND | | | MULTI-GANG BATHROOMS IF BUILDING IS OCCUPIED UNDER | | | EMERGENCY POWER. | | | NFPA-101 7.9 PERMITS THE GENERATOR FOR BACK UP OF | | | EGRESS LIGHTING FOR THE OCCUPANTS TO LEAVE THE PREMISES | | | AND BUILDING IS TO REMAIN UNOCCUPIED UNTIL NORMAL POWER | | | IS BACK TO NORMAL. | | | IF BUILDING IS NOT GOING TO BE OCCUPIED UNDER THE BACK | | | UP OF THE GENERATOR THE HALLWAYS MAY REMAIN ON | | | GENERATOR HOWEVER BATHROOMS WILL REQUIRED A MINIMUM OF | | | ONE TYPE OF BATTERY BACK UP FIXTURE. | | | | | | IF THERE ARE NAY QUESTIONS PLEASE CONTACT THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-29 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-29 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2008-04-29 15:57:35 | ** DENIEDREVIEW ** | | | | | | 1) NOTE: | | | | | | 2) NOTE: PLEASE INDICATE THE MAXIMUM TIMES ON OCCUPANCY | | | SENSOR LISTED ON SYMBOL LEGEND. | | | FBC 13-415.1.ABC.1.1, .1.2 | | | | | | 3) NOTE: PLEASE SHOW/INDICATE EMERGENCY LIGHTING IN | | | EACH OF THE MULTI-GANG RESTROOMS. ONE FIXTURE MINIMUM | | | IS REQUIRED IN EACH FOR 1FT CANDLE MINIMUM LEVEL UNDER | | | EMERGENCY CONDITIONS. | | | LS 101 7.9 | | | | | | 4) NOTE: PLEASE VERIFY THE EXISTING PANEL 16EL1. THIS | | | IS SHOWN AS A 100AMP YET THE INFORMATION STATE ON PANEL | | | MENTIONS A NEW 200AMP MAIN CIRCUIT BREAKER. | | | PLEASE ALSO VERIFY RATING OF PANEL WHICH STATES | | | 240/480, AND OPERATING VOLTAGE OF 277/480V. | | | 110.3, 90.7 | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION AND | | | COORDINATION. | | | | | | 5) NOTE: PLEASE VERIFY ANY HORN/STROBES IN RESTROOMS | | | PER FBC 11-4.28.1, .2 AND PLEASE VERIFY LEVELS PER | | | .3(4) FOR ADA. | | | | | | 6) NOTE: PLEASE BE SURE THE 2003 NFPA-101, 2002 NFPA-72 | | | IS LISTED ON ELECTRICAL PLANS. | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-30 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-30 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2008-06-30 11:49:44 | SENT TO L. MARTINEZ TO BE PROCESSED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-05-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-05-08 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-05-08 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2008-05-08 11:08:42 | ***DENIED*** | | | | | | 1) NFPA 101, 2003 TO BE ILLUSTRATED ON PLANS. | | | | | | 2) PLEASE SHOW LOCATION(S) OF REQUIRED 2A-10B,C RATED | | | FIRE EXTINGUISHERS. | | | | | | 3) WILL WORK IMPACT EXISTING FIRE PROTECTION EQUIPMENT | | | IN BATHROOMS. PLEASE SEE ELECTRICAL COMMENT REGARDING | | | EMERGENCY LIGHTING FACILITIES. | | | | | | 4) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER AND FIRE ALARM REMODEL IF APPLICABLE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-04 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-04 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2008-06-04 10:57:57 | TO "COMM" BD#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-05-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-05-08 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-23 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2008-04-23 11:09:55 | TO "COMM" BD#60 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-01 |
Time |
13:15 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-05-01 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-06-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-18 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-18 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2008-06-18 10:25:24 | NOTE: FIXTURE CHANGE OUT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-05-01 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-01 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2008-05-01 15:35:52 | NOTE: FIXTURE CHANGE OUT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-05-01 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-05-01 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2008-05-01 10:22:42 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|