| Plan Review Stops For Permit 08040571 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-01-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-01-21 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-01-21 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2009-01-21 10:10:57 | REVISED S1 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-08-18 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-18 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-07-01 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-07-01 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2008-07-01 10:26:43 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1-2. ADDRESSED. | | | | | | 3.INFORMATIONAL; THIS IS A PLAN CHECK ONLY.THE | | | REVIEW WILL REMAIN IN FAILED STATUS UNTIL A CONTRACTOR | | | LICENSED TO DO THE WORK HAS APPLIED FOR PERMIT, AND ALL | | | PLAN REVIEW ISSUES HAVE BEEN ADDRESSED. | | | | | | 4.ADDRESSED. | | | | | | 5.SHEET A8, FIGURE 30E, REVISE GRAB BAR DISTANCE FROM | | | CORNER.THE PLAN STATES 6IN MIN; THIS SHOULD BE 6IN | | | MAX FBC FIGURE 11-30E. | | | | | | 2ND REVIEW, FIGURE 30(E) WAS CLOUDED BUT NOT REVISED. | | | FIGURE 29 WAS REVISED; PREVIOUSLY SPECIFIED "6IN MAX" | | | (WHICH WAS PREVIOUSLY CORRECT) AND NOW STATES "6IN MIN" | | | (WHICH IS NOW INCORRECT).SEE FBC FIGURE 11-30E, 6" | | | MAX DISTANCE REQUIRED FOR GRAB BARS, NOT 6" MIN AS | | | SPECIFIED. | | | | | | 6.ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-05-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-05-08 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-05-08 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2008-05-08 10:16:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.DECLARE LEVEL OF ALTERATION, FBC EXISTING BUILDING | | | CODE, CHAPTER 3. | | | | | | 2.PLEASE REVISE GOVERNING CODE TO INCLUDE 2007 | | | REVISIONS/SUPPLEMENTS. | | | | | | 3.INFORMATIONAL; THIS IS A PLAN CHECK ONLY.THE | | | REVIEW WILL REMAIN IN FAILED STATUS UNTIL A CONTRACTOR | | | LICENSED TO DO THE WORK HAS APPLIED FOR PERMIT, AND ALL | | | PLAN REVIEW ISSUES HAVE BEEN ADDRESSED. | | | | | | 4.CERTIFICATE OF AUTHORIZATION REQUIRED FOR ENGINEER, | | | ARCHITECT, TO PRACTICE THROUGH A COMPANY, FS481.219(2), | | | FS471.023, AND THE LICENSE NUMBER IS TO PRINTED ON EACH | | | SHEET, FAC61G1-16, FAC61G15-23.002. | | | | | | 5.SHEET A8, FIGURE 30E, REVISE GRAB BAR DISTANCE FROM | | | CORNER.THE PLAN STATES 6IN MIN; THIS SHOULD BE 6IN | | | MAX FBC FIGURE 11-30E. | | | | | | 6.PLEASE SEE FBC11-4.28, ALARMS.PLEASE SHOW | | | COMPLIANCE ON THE PLAN, IN THE FORM OF A GENERAL NOTE | | | AND ALSO IN AREAS SUCH AS BATHROOMS.THE PLAN STATES | | | ON E1, GENERAL NOTE 31, THAT FIRE ALARM IS NOT WITHIN | | | THE SCOPE OF THIS PERMIT.HOWEVER, COMPLIANCE WITH | | | ACCESSIBILITY REQUIREMENTS (SUCH AS ADDING | | | AUDIBLE/VISUAL ALARMS IN THE BATHROOMS AND OTHER | | | GENERAL USE AREAS IF CURRENTLY NONE EXIST) MAY BE | | | REQUIRED.FBC11-4.1.6(1)(B). | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-28 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-28 |
Time |
16:54 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-08-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-11 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-11 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2008-08-11 16:23:05 | | | | **DENIED3RD REVIEW** | | | | | | FIRST REVIEW UNDER PERMIT APPLICATION. | | | SAME COMMENT FROM PREVIOUS REVIEW. | | | | | | 1) NOTE:PLEASE SUBMIT LIGHTING PERFORMANCE | | | CALCULATIONS PER 13-415.2, 13-415.2.ABC.1.1 AND.1.2. | | | THE NEW NOTE ON PLANS INDICATES A LIGHTING POWER USE OF | | | 160 WATTS WHICH IS NOT POSSIBLE BASED ON WHAT IS SHOWN | | | ON PLANS. | | | PLEASE SEE SECTION 13-415.2.ABC.1.1, .1.2. THE WATTAGE | | | FOR TRACK LIGHTING SHALL BE BASED ON THE VA RATING OF | | | EACH FIXTURE TIMES THE NUMBER OF FIXTURES OR 30VA PER | | | FT OF TRACK WHICH EVER IS GREATER. BASED ON THE PLANS | | | AND THE LENGTH OF TRACK THE TOTAL WATTAGE IS OVER 1200 | | | WHICH EXCEEDS THE MAXIMUM ALLOWED BY THE CODE. | | | NO PERFORMANCE WAS GIVEN FOR OTHER LOCATIONS. | | | PLEASE BE SURE TO COMPLETE ALL FIXTURE INFORMATION. | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-03 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-03 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2008-07-03 14:49:20 | | | | | | | ** DENIED ** | | | | | | 1) NOTE:PLANS STILL ONLY SUBMITTED FOR PLAN REVIEW | | | AND NOT FOR PERMIT. | | | | | | 2) NOTE: LIGHTING PERFORMANCE CALCULATIONS SHOWN FOR | | | BATHROOM HOWEVER NOT FOR NEW DISPLAY ARE PER | | | 13-415.2.ABC.1.1,.1.2 | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-05 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-05 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2008-05-05 17:36:57 | ** DENIED** | | | | | | 1) NOTE: PLEASE SEE PLANS HAVE ONLY BEEN SUBMITTED FOR | | | *PLAN REVIEW* ONLY AND HAVE NOT BEEN SUBMITTED FOR | | | PERMIT. | | | ONCE PLANS ARE FOUND TO BE CODE COMPLIANT REVIEWS WILL | | | STILL REMAIN IN A FAILED STATUS UNTIL PERMIT IS APPLIED | | | FOR BY A LICENSED CONTRACTOR. PLEASE KNOW ANY CODE | | | CHANGES MAY AFFECT THE PLANS WHEN APPLICATION IS | | | FINALLY MADE ALONG WITH OTHER LICENSING ITEMS WHICH ARE | | | VERIFIED WHEN UNDER PERMIT APPLICATION. | | | | | | 2) NOTE: PLEASE SEE MISSING REQUIRED TITLE BLOCK | | | INFORMATION FOR THE ARCHITECTURAL, ENGINEERING PLANS. | | | PLEASE SEE MISSING CERTIFICATE OF AUTHORIZATION | | | REQUIRED FOR BOTH FIRMS PER FS 481.219 FOR | | | ARCHITECTURAL FIRM AND FS 471.023 FOR ENGINEERING | | | FIRM. | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | ANY OTHER REVIEWER(S). | | | | | | 3) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE LISTED | | | ON ELECTRICAL AND ARCHITECTURAL SHEETS. THESE ARE | | | REQUIRED FOR THIS REVIEWER AT A MINIMUM. | | | 2004 FBCW/2007 REVISIONS | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | | | | ** PLEASE SEE THE CODES AS LISTED ON PLANS ARE NOT | | | APPLICABLE. THE STATE OF FLORIDA IS NOT UNDER IBC, IMC, | | | IPCOR THE 2002 NEC. | | | PLEASE SEE THE INCORRECT CODE FOR ENERGY COMPLIANCE IS | | | ALSO NOTED. | | | 2004 FBC W/2007 REVISIONS FOR FLORIDA ENERGY EFFICIENCY | | | CODE. | | | | | | 4) NOTE: PLEASE VERIFY LIGHTING CONTROLS FOR ANY NEW | | | LOCATIONS FOR SEPARATE SPACES IN BUILDINGS OVER 5K SQ | | | FT. | | | THIS WOULD APPLY TO NEW BATH ROOMS FOR EXAMPLE: PLEASE | | | SEE OTHER AREAS AS NOTED IN SECTIONS BELOW. THESE NEED | | | TO MEET *MINIMUM PRESCRIPTIVE REQUIREMENTS*. | | | 13-415.1.ABC.1.1, .1.2 AND .1.3 | | | | | | 5) NOTE: PLEASE SEE 13-415.2, 13-415.1.ABC.1.1, .1.2 | | | FOR MINIMUM PERFORMANCE CALCULATIONS. | | | | | | 6) NOTE: PLEASE KNOW THIS IS FOR INFORMATIONAL PURPOSE. | | | A CORRECTION NOTICE WAS ISSUED FOR THE LOCATION OF THE | | | GENERATOR WHICH IS NOT PERMITTED IN THE MAIN ELECTRICAL | | | ROOM. THIS IS A LIFE SAFETY AND FIRE HAZARD. | | | PLEASE BE AWARE. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-14 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-08-14 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2008-08-14 15:35:48 | *****APPROVED***** | | | | | | | | | PLAN SHEETS LS-1 AND LS-2 WERE STAMPED, INITIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-07-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-15 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-15 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2008-07-15 13:42:49 | PLANS OK | | | | | | COMMENTS FROM FIRST FIRE REVIEW HAVE BEEN ADDRESSED. | | | PLANS WILL REMAIN IN FAILED STATUS UNTIL PLAN REVIEW AT | | | TIME OF PERMITTING. | | | | | | PLANS ARE SUBMITTED FOR PLAN REVIEW ONLY AND NOT FOR | | | PERMIT. PLEASE SEE FOLLOWING: | | | | | | 1) SEPARATE SHOP DRAWINGS AND PERMITS WILL BE REQUIRED | | | FOR FIRE SPRINKLER AND FIRE ALARM REMODEL. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-05-22 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-05-22 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2008-05-22 16:43:59 | *****DENIED***** | | | | | | | | | 1. IN ADDITION TO THE FIRE CODE (FLORIDA FIRE | | | PREVENTION CODE 2004) LISTED ON SHEET T-1, NFPA 101, | | | LIFE SAFETY CODE, 2003 EDITION SHALL BE REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FORM THE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 4.THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE | | | WITH ACCESS TO OR EGRESS FROM THE PROPERTY OR OTHER | | | TENANT SPACES IN THE PALM COAST SHOPPING PLAZA. | | | | | | 5.WILL THE BUILDING OR PORTION OF THE BUILDING BE | | | OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATIONS, OR | | | ADDITION? | | | | | | 6.SHOW EMERGENCY LIGHTING FOR THIS FACILITY. | | | | | | 7.SPECITY INTERIOR WALL AND CEILING FINISH MATERIALS | | | IN TERMS OF CLASS A OR CLASS B. | | | | | | 8.PROVIDE A LAYOUT OF THE FIRE ALARM SYTEM DEVICES | | | FOR THE BUILDING IN RELATION TO THE NEW SCOPE OF WORK. | | | | | | 9.PROVIDE A LAYOUT OF THE FIRE SPRINKLER HEADS FOR | | | THE BUILDING IN RELATION TO THE NEW SCOPE OF WORK. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET | | | EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT.MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-21 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-21 |
Time |
09:51 |
Sent To |
E |
|
| Notes |
| 2008-08-21 09:52:21 | SEPARATE GAS PERMIT REQUIRED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-05 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-05 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2008-08-05 11:05:55 | GAS PLANS APPROVED--SEPARATE PERMIT REQUIRED-- | | | STATUS WILL CHANGE WHEN APPLICATION FOR PERMIT | | | SUBMITTED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-10 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-10 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2008-07-10 13:31:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS W/2007 AMENDMENTS | | | | | | | | | ****FROM PREVIOUS REVEIW: | | | | | | 1. SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT | | | THE FOLLOWING INFORMATION FOR PERMIT: | | | | | | A. OK | | | | | | B. TYPE OF GAS, (LP OR NATURAL). | | | ****RESPONSE NOTED, BUT GAS TYPE NOT INDICATED. | | | | | | C. OK | | | D. OK | | | E. OK | | | F. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2008-05-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-03 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-03 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2008-07-10 11:52:43 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS W/2007 AMENDMENTS | | | | | | 1. SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT | | | THE FOLLOWING INFORMATION FOR PERMIT: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. INDICATE THE LENGTH OF PIPING FROM THE | | | GAS METER TO THE GENERATOR. | | | | | | B. TYPE OF GAS, (LP OR NATURAL). | | | | | | C. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). ALSO INDICATE THE BTU LOAD FOR THE | | | GENERATOR. | | | | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. (NEW EQUIPMENT). | | | | | | E. INDICATE THE PIPE SIZE FROM THE METER TO THE FIRST | | | TEE AND THE EXISTING PIPE SIZE TO THE GENERATOR. | | | | | | F. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. PLEASE | | | INDICATE EACH VALVE AND UNION ON RISER. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-12-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-30 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-30 |
Time |
10:36 |
Sent To |
P |
|
| Notes |
| 2008-12-30 10:37:23 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-12-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-23 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-23 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2008-12-23 10:05:24 | TO "COMM" BD#29 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-11-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-21 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-21 |
Time |
11:32 |
Sent To |
M |
|
| Notes |
| 2008-11-21 11:33:20 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-08-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-20 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-20 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2008-08-20 15:02:44 | TO "KSTEVENS" DESK/RESUB--PER "LMARTINEZ" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-28 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-28 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2008-07-28 16:49:39 | TO "COMM" BD#36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-06-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-11 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-11 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2008-06-11 09:16:26 | TO "COMM" BD#54 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-05-22 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-04-22 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2008-04-25 14:39:08 | TO "COMM" BD#63 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-01-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2009-01-28 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2009-01-28 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2009-01-28 15:18:23 | REVISED PAGE S-1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-24 |
Time |
21:28 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-24 |
Time |
21:27 |
Sent To |
PC |
|
| Notes |
| 2008-11-24 21:28:00 | REVISED M1 AND M2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-08 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-08 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2008-08-08 10:54:38 | *****************PROVISO**************** | | | OUTDOOR APPLIANCES, SUCH AS EXHAUST AND SUPPLY FANS, | | | ARE DESIGNED TO RESIST WIND PRESSURES IN ACCORDANCE | | | WITH FBCM 301.13.SUPPORTING DOCUMENTATION FROM THE | | | APPLIANCE MANUFACTURER SHALL BE SUBMITTED FOR REVIEW | | | PRIOR TO FIRST INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-01 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-01 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2008-07-01 16:32:47 | REVIEW #: 2ND **PLAN CHECK ONLY** | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE AND | | | STAMPED. REVIEW WILL REMIAN IN FAIL STATUS UNTIL PERMIT | | | APPLICATION IS SUBMITTED. ALSO, SEE PROVISO ITEM | | | BELOW: | | | | | | *****************PROVISO**************** | | | OUTDOOR APPLIANCES, SUCH AS EXHAUST AND SUPPLY FANS, | | | ARE DESIGNED TO RESIST WIND PRESSURES IN ACCORDANCE | | | WITH FBCM 301.13.SUPPORTING DOCUMENTATION FROM THE | | | APPLIANCE MANUFACTURER SHALL BE SUBMITTED FOR REVIEW | | | PRIOR TO FIRST INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-05-13 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-13 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-13 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2008-05-13 15:40:41 | REVIEW #: 1ST **PLAN CHECK ONLY** | | | ACTION: | | | | | | THESE PLANS WERE REVIEWED UNDER THE FOLLOWING CODES: | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | REVIEW COMMENTS: | | | | | | 1. PLEASE PROVIDE CLEAR DELINEATION OF WHAT DUCTWORK IS | | | NEW AND WHAT DUCTWORK IS EXISTING TO REMAIN. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE IN ACCORDANCE WITH FBCB | | | 106.1.1. | | | | | | 2. CONSTRUCTION NOTE #1 INDICATES THAT AN EXISTING | | | STEAM HOOD IS TO REMAIN IN THE DELI AREA. PAGE A-1 | | | INDICATES A 6-BURNER STOVE AT THIS LOCATION. A TYPE I | | | HOOD IS REQUIRED AT THIS LOCATION IN ACCORDANCE WITH | | | FBCM 507.2.1. PLEASE SHOW MEANS AND LOCATION OF | | | COMMERCIAL KITCHEN EXHAUST AS REQUIRED IN ACCORDANCE | | | WITH FBCM 507.2. | | | | | | 3. PAGE A-1 INDICATES A RELOCATED EXISTING | | | ROTISSERIE/CONVECTION OVEN AGAINST THE EAST WALL IN THE | | | DELI. PAGE M-1 DOES NOT SHOW ANY TYPE OF HOOD OVER THIS | | | APPLIANCE. PLEASE SHOW MEANS AND LOCATION OF COMMERCIAL | | | KITCHEN EXHAUST AS REQUIRED IN ACCORDANCE WITH FBCM | | | 507.2. | | | | | | 4. HOOD SCHEDULE ON PG M-2 SHOWS H-1 AND H-2 BUT THERE | | | IS A DETAIL FOR A HOOD #3 ON THIS PAGE. PLEASE CLARIFY | | | THE NUMBER OF HOODS ALONG WITH LOCATIONS AND | | | SPECIFICATIONS. FBCM 507.1, FBCB 106.1.1. | | | | | | 5. HOOD SUPPLY/EXHAUST FAN DETAIL ON PG M-2: MECHANICAL | | | EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO | | | WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND | | | PRESSURES ON THE EQUIPMENT AND THE SUPPORTS AS | | | DETERMINED IN ACCORDANCE WITH FBCM 301.13 AND FBCB | | | 1609. THE FOLLOWING IS REQUIRED: DETAILS WITH | | | SUPPORTING WIND LOAD CALCULATIONS FOR NEW CURB AND DUCT | | | SUPPORT ATTACHMENTS TO STRUCTURE, APPLIANCE ATTACHMENTS | | | TO CURBS AND MANUFACTURER?S SUBMITTAL DATA SHOWING THE | | | NEW APPLIANCES ARE DESIGNED AND CONSTRUCTED TO RESIST | | | ANTICIPATED WIND PRESSURES IN ACCORDANCE WITH THIS | | | SECTION. | | | | | | NOTE: SEPARATE PERMITS REQUIRED FOR KITCHEN HOOD, HOOD | | | SUPPRESSION AND REFRIGERATION SYSTEMS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2009-01-26 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2009-01-26 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2009-01-26 10:47:19 | LETTER FOR FASTENING ROOF BRACKETS- OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-21 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-21 |
Time |
09:51 |
Sent To |
E |
|
| Notes |
| 2008-08-21 09:52:42 | SEPARATE PLUMBING PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-05 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-05 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2008-08-05 12:57:28 | PLANS APPROVED--STATUS WILL CHANGE WHEN PERMIT | | | APPLICATION SUBMITTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-10 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-10 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2008-07-10 13:28:56 | DENIED | | | REFERENCE: FBC-2004 PLUMBING W/2007 AMENDMENTS | | | FBC-2004 FUEL GAS W/2007 AMENDMENTS | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUES | | | CITY WPB MUNICIPAL CODE | | | | | | ****FROM PREVIOUS REVEIW: | | | | | | 1. OK | | | | | | 2. ALL PME & SPC SHEETS SHALL INCLUDE THE CERTIFICATE | | | OF AUTHORIZATION FOR THE ENGINEERING COMPANY IN THE | | | TITLE BLOCK OF EACH SHEET. ALSO THE ADDRESS FOR | | | CUBELLIS INC IN INDICATED AS 711 ATLANTIC AVENUE BOSTON | | | MA. ON THE FLORIDA STATE DBPR WEBSITE WHICH DOES NOT | | | REFLECT THE ADDRESS INDICATED IN THE TITLE BLOCK OF | | | EACH SHEET. (97 LIBBEY INDUSTRIAL PARKWAY WEYMOUTH MA). | | | PLEASE UPDATE THE TITLE BLOCK OR THE DBPR WEBSITE PRIOR | | | TO RESUBMITTING TO THE CITY FOR REVIEW. (SEE ATTACHED | | | SHEET). FAC 61G15-23.002(2) & FS 471.2055. ****RESPONSE | | | NOTED, BUT THE ADDRESS LISTED FOR CA NUMBER 27279 IS | | | 711 ATLANTIC AVE BOSTON WHICH DOES NOT REFLECT THE | | | ADDRESS IN THE TITLE BLOCKS OF THE PME OR SPC SHEETS. | | | (281 SUMMER ST OR 1800 ELLER DR). | | | | | | 3. OK | | | | | | 4. SHT P-2 DRAWING NOTES #11 AND WASTE PIPING PLAN | | | PIPING TO & INCLUDING THE GREASE INTERCEPTOR ARE NOT | | | APPROVED. ARTICLE III SECTION 90-124(7)(B). PLEASE | | | CONNECT ROTISSERIE TO EXISTING GREASE SYSTEM TO CATCH | | | MINIMUM AMOUNT OF GREASE. THE ROTISSERIE SHALL DRAIN | | | INTO A CONTAINER WHICH SHALL CATCH THE GREASE AND BE | | | DISPOSED OF PROPERLY WITH OUT DRAINING INTO THE | | | SYSTEM. | | | ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES | | | NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD | | | PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES | | | "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO | | | BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH | | | THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER | | | INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR | | | GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER | | | SECTION 802.3.2. | | | | | | 5. OK | | | 6. OK | | | | | | 7. SHT P-5 GREASE INTERCEPTOR AT ROTISSERIE IS NOT | | | APPROVED. ARTICLE III SECTION 90-124(7)(B). | | | ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES | | | NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD | | | PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES | | | "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO | | | BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH | | | THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER | | | INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR | | | GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER | | | SECTION 802.3.2. | | | | | | 8. OK | | | 9. OK | | | | | | 10 SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT | | | THE FOLLOWING INFORMATION FOR PERMIT: | | | | | | A. OK | | | | | | B. TYPE OF GAS, (LP OR NATURAL). | | | ****RESPONSE NOTED, BUT GAS TYPE NOT INDICATED. | | | | | | C. OK | | | D. OK | | | E. OK | | | F. OK | | | | | | 11. SHT P-7 THE PLUMBING LEGEND AND SCHEDULE #50 AS | | | WELL AS THE GREASE TRAP DETAIL ARE NOT APPROVED. | | | ARTICLE III SECTION 90-124(7)(B). PLEASE DELETE FROM | | | PLANS. | | | ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES | | | NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD | | | PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES | | | "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO | | | BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH | | | THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER | | | INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR | | | GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER | | | SECTION 802.3.2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-05-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-03 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-03 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2008-05-03 17:16:34 | DENIED | | | REFERENCE: FBC-2004 PLUMBING W/2007 AMENDMENTS | | | FBC-2004 FUEL GAS W/2007 AMENDMENTS | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUES | | | CITY WPB MUNICIPAL CODE | | | | | | 1. ALL ARCHITECTURAL SHEETS. CUBELLIS'S TITLE BLOCK | | | ADDRESS DOES NOT REFLECT THE ADDRESS OF RECORD ON THE | | | STATE OF FLORIDA DBPR WEBSITE.(97 LIBBEY INDUSTRIAL | | | PARKWAY WEYMOUTH MA. ON TITLE BLOCK--1800 ELLERY DR | | | BOSTON MA. ON DBPR WEBSITE). PLEASE UPDATE THE TITLE | | | BLOCK OR THE DBPR WEBSITE PRIOR TO RESUBMITTING TO THE | | | CITY FOR REVIEW. (SEE ATTACHED SHEET). FAC | | | 61G1-16.004(1) & FS 481.025. | | | | | | 2. ALL PME & SPC SHEETS SHALL INCLUDE THE CERTIFICATE | | | OF AUTHORIZATION FOR THE ENGINEERING COMPANY IN THE | | | TITLE BLOCK OF EACH SHEET. ALSO THE ADDRESS FOR | | | CUBELLIS INC IN INDICATED AS 711 ATLANTIC AVENUE BOSTON | | | MA. ON THE FLORIDA STATE DBPR WEBSITE WHICH DOES NOT | | | REFLECT THE ADDRESS INDICATED IN THE TITLE BLOCK OF | | | EACH SHEET. (97 LIBBEY INDUSTRIAL PARKWAY WEYMOUTH MA). | | | PLEASE UPDATE THE TITLE BLOCK OR THE DBPR WEBSITE PRIOR | | | TO RESUBMITTING TO THE CITY FOR REVIEW. (SEE ATTACHED | | | SHEET). FAC 61G15-23.002(2) & FS 471.2055 | | | | | | 3. SHT P-1 REFRIGERATION TUBING PLAN. WORK INDICATED IN | | | MECHANICAL AND SHALL BE SUBMITTED IN THE MECHANICAL | | | PLANS, NOT THE PLUMBING PLANS. PLEASE SUBMIT UNDER | | | MECHANICAL PLANS. FS 489. | | | | | | 4. SHT P-2 DRAWING NOTES #11 AND WASTE PIPING PLAN | | | PIPING TO & INCLUDING THE GREASE INTERCEPTOR ARE NOT | | | APPROVED. ARTICLE III SECTION 90-124(7)(B). PLEASE | | | CONNECT ROTISSERIE TO EXISTING GREASE SYSTEM TO CATCH | | | MINIMUM AMOUNT OF GREASE. THE ROTISSERIE SHALL DRAIN | | | INTO A CONTAINER WHICH SHALL CATCH THE GREASE AND BE | | | DISPOSED OF PROPERLY WITH OUT DRAINING INTO THE | | | SYSTEM. | | | | | | 5. SHT P-3 WATER DISTRIBUTION NOTE #7 WATER HAMMER | | | ARRESTORS SHALL BE LOCATED NEAR THE FIXTURES, IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING. SECTION 604.9 & | | | PDI-WH 201. | | | | | | 6. SHT P-5 SHOW THE CHANGE IN LOCATION FOR THE WATER | | | CLOSET AND THE LAV IN THE ACCESSIBLE STALLS ON THE | | | SANITARY RISER DIAGRAM. SECTION 106.3.5.1.3. | | | | | | 7. SHT P-5 GREASE INTERCEPTOR AT ROTISSERIE IS NOT | | | APPROVED. ARTICLE III SECTION 90-124(7)(B). | | | | | | 8. SHT P-5 INDICATE WHERE THE BRANCH LINE CONNECTS TO | | | THE BUILDING GREASE DRAIN LINE DOWNSTREAM OF THE | | | ROTISSERIE. SECTION 106.1.2. | | | | | | 9. SHT P-6 SHOW THE CHANGE IN LOCATION FOR THE WATER | | | CLOSET AND THE LAV IN THE ACCESSIBLE STALLS ON THE | | | WATER RISER DIAGRAM. SECTION 106.3.5.1.3. | | | | | | 10 SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT | | | THE FOLLOWING INFORMATION FOR PERMIT: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. INDICATE THE LENGTH OF PIPING FROM THE | | | GAS METER TO THE GENERATOR. | | | | | | B. TYPE OF GAS, (LP OR NATURAL). | | | | | | C. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). ALSO INDICATE THE BTU LOAD FOR THE | | | GENERATOR. | | | | | | D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. (NEW EQUIPMENT). | | | | | | E. INDICATE THE PIPE SIZE FROM THE METER TO THE FIRST | | | TEE AND THE EXISTING PIPE SIZE TO THE GENERATOR. | | | | | | F. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. PLEASE | | | INDICATE EACH VALVE AND UNION ON RISER. | | | | | | 11. SHT P-7 THE PLUMBING LEGEND AND SCHEDULE #50 AS | | | WELL AS THE GREASE TRAP DETAIL ARE NOT APPROVED. | | | ARTICLE III SECTION 90-124(7)(B). PLEASE DELETE FROM | | | PLANS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-07-14 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-07-09 |
Time |
17:54 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-07-09 |
Time |
17:54 |
Sent To |
|
|
| Notes |
| 2008-07-09 18:00:01 | NOT REQUIRED |
|
|