Plan Review Details - Permit 08040571
Plan Review Stops For Permit 08040571
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-01-21 Cont ID  
Sent By shill Date 2009-01-21 Time 10:10 Rev Time 0.00
Received By shill Date 2009-01-21 Time 10:10 Sent To  
Notes
2009-01-21 10:10:57REVISED S1
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-08-18 Cont ID  
Sent By shill Date 2008-08-18 Time 09:13 Rev Time 0.00
Received By shill Date 2008-08-18 Time 09:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-07-01 Cont ID  
Sent By shill Date 2008-07-01 Time 10:22 Rev Time 0.00
Received By shill Date 2008-07-01 Time 10:22 Sent To  
Notes
2008-07-01 10:26:43****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1-2. ADDRESSED.
  
 3.INFORMATIONAL; THIS IS A PLAN CHECK ONLY.THE
 REVIEW WILL REMAIN IN FAILED STATUS UNTIL A CONTRACTOR
 LICENSED TO DO THE WORK HAS APPLIED FOR PERMIT, AND ALL
 PLAN REVIEW ISSUES HAVE BEEN ADDRESSED.
  
 4.ADDRESSED.
  
 5.SHEET A8, FIGURE 30E, REVISE GRAB BAR DISTANCE FROM
 CORNER.THE PLAN STATES 6IN MIN; THIS SHOULD BE 6IN
 MAX FBC FIGURE 11-30E.
  
 2ND REVIEW, FIGURE 30(E) WAS CLOUDED BUT NOT REVISED.
 FIGURE 29 WAS REVISED; PREVIOUSLY SPECIFIED "6IN MAX"
 (WHICH WAS PREVIOUSLY CORRECT) AND NOW STATES "6IN MIN"
 (WHICH IS NOW INCORRECT).SEE FBC FIGURE 11-30E, 6"
 MAX DISTANCE REQUIRED FOR GRAB BARS, NOT 6" MIN AS
 SPECIFIED.
  
 6.ADDRESSED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-05-08 Cont ID  
Sent By shill Date 2008-05-08 Time 10:16 Rev Time 0.00
Received By shill Date 2008-05-08 Time 10:16 Sent To  
Notes
2008-05-08 10:16:50****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.DECLARE LEVEL OF ALTERATION, FBC EXISTING BUILDING
 CODE, CHAPTER 3.
  
 2.PLEASE REVISE GOVERNING CODE TO INCLUDE 2007
 REVISIONS/SUPPLEMENTS.
  
 3.INFORMATIONAL; THIS IS A PLAN CHECK ONLY.THE
 REVIEW WILL REMAIN IN FAILED STATUS UNTIL A CONTRACTOR
 LICENSED TO DO THE WORK HAS APPLIED FOR PERMIT, AND ALL
 PLAN REVIEW ISSUES HAVE BEEN ADDRESSED.
  
 4.CERTIFICATE OF AUTHORIZATION REQUIRED FOR ENGINEER,
 ARCHITECT, TO PRACTICE THROUGH A COMPANY, FS481.219(2),
 FS471.023, AND THE LICENSE NUMBER IS TO PRINTED ON EACH
 SHEET, FAC61G1-16, FAC61G15-23.002.
  
 5.SHEET A8, FIGURE 30E, REVISE GRAB BAR DISTANCE FROM
 CORNER.THE PLAN STATES 6IN MIN; THIS SHOULD BE 6IN
 MAX FBC FIGURE 11-30E.
  
 6.PLEASE SEE FBC11-4.28, ALARMS.PLEASE SHOW
 COMPLIANCE ON THE PLAN, IN THE FORM OF A GENERAL NOTE
 AND ALSO IN AREAS SUCH AS BATHROOMS.THE PLAN STATES
 ON E1, GENERAL NOTE 31, THAT FIRE ALARM IS NOT WITHIN
 THE SCOPE OF THIS PERMIT.HOWEVER, COMPLIANCE WITH
 ACCESSIBILITY REQUIREMENTS (SUCH AS ADDING
 AUDIBLE/VISUAL ALARMS IN THE BATHROOMS AND OTHER
 GENERAL USE AREAS IF CURRENTLY NONE EXIST) MAY BE
 REQUIRED.FBC11-4.1.6(1)(B).
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-08-28 Cont ID  
Sent By dpalmer Date 2008-08-28 Time 16:54 Rev Time 0.00
Received By dpalmer Date 2008-08-28 Time 16:54 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2008-08-11 Cont ID  
Sent By dpalmer Date 2008-08-11 Time 15:43 Rev Time 0.00
Received By dpalmer Date 2008-08-11 Time 15:43 Sent To  
Notes
2008-08-11 16:23:05 
 **DENIED3RD REVIEW**
  
 FIRST REVIEW UNDER PERMIT APPLICATION.
 SAME COMMENT FROM PREVIOUS REVIEW.
  
 1) NOTE:PLEASE SUBMIT LIGHTING PERFORMANCE
 CALCULATIONS PER 13-415.2, 13-415.2.ABC.1.1 AND.1.2.
 THE NEW NOTE ON PLANS INDICATES A LIGHTING POWER USE OF
 160 WATTS WHICH IS NOT POSSIBLE BASED ON WHAT IS SHOWN
 ON PLANS.
 PLEASE SEE SECTION 13-415.2.ABC.1.1, .1.2. THE WATTAGE
 FOR TRACK LIGHTING SHALL BE BASED ON THE VA RATING OF
 EACH FIXTURE TIMES THE NUMBER OF FIXTURES OR 30VA PER
 FT OF TRACK WHICH EVER IS GREATER. BASED ON THE PLANS
 AND THE LENGTH OF TRACK THE TOTAL WATTAGE IS OVER 1200
 WHICH EXCEEDS THE MAXIMUM ALLOWED BY THE CODE.
 NO PERFORMANCE WAS GIVEN FOR OTHER LOCATIONS.
 PLEASE BE SURE TO COMPLETE ALL FIXTURE INFORMATION.
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-07-03 Cont ID  
Sent By dpalmer Date 2008-07-03 Time 14:49 Rev Time 0.00
Received By dpalmer Date 2008-07-03 Time 14:49 Sent To  
Notes
2008-07-03 14:49:20 
  
 ** DENIED **
  
 1) NOTE:PLANS STILL ONLY SUBMITTED FOR PLAN REVIEW
 AND NOT FOR PERMIT.
  
 2) NOTE: LIGHTING PERFORMANCE CALCULATIONS SHOWN FOR
 BATHROOM HOWEVER NOT FOR NEW DISPLAY ARE PER
 13-415.2.ABC.1.1,.1.2
  
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-05-05 Cont ID  
Sent By dpalmer Date 2008-05-05 Time 17:36 Rev Time 0.00
Received By dpalmer Date 2008-05-05 Time 17:36 Sent To  
Notes
2008-05-05 17:36:57** DENIED**
  
 1) NOTE: PLEASE SEE PLANS HAVE ONLY BEEN SUBMITTED FOR
 *PLAN REVIEW* ONLY AND HAVE NOT BEEN SUBMITTED FOR
 PERMIT.
 ONCE PLANS ARE FOUND TO BE CODE COMPLIANT REVIEWS WILL
 STILL REMAIN IN A FAILED STATUS UNTIL PERMIT IS APPLIED
 FOR BY A LICENSED CONTRACTOR. PLEASE KNOW ANY CODE
 CHANGES MAY AFFECT THE PLANS WHEN APPLICATION IS
 FINALLY MADE ALONG WITH OTHER LICENSING ITEMS WHICH ARE
 VERIFIED WHEN UNDER PERMIT APPLICATION.
  
 2) NOTE: PLEASE SEE MISSING REQUIRED TITLE BLOCK
 INFORMATION FOR THE ARCHITECTURAL, ENGINEERING PLANS.
 PLEASE SEE MISSING CERTIFICATE OF AUTHORIZATION
 REQUIRED FOR BOTH FIRMS PER FS 481.219 FOR
 ARCHITECTURAL FIRM AND FS 471.023 FOR ENGINEERING
 FIRM.
 ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY
 ANY OTHER REVIEWER(S).
  
 3) NOTE: PLEASE BE SURE THE FOLLOWING CODES ARE LISTED
 ON ELECTRICAL AND ARCHITECTURAL SHEETS. THESE ARE
 REQUIRED FOR THIS REVIEWER AT A MINIMUM.
 2004 FBCW/2007 REVISIONS
 2005 NFPA-70
 2003 NFPA-101
  
 ** PLEASE SEE THE CODES AS LISTED ON PLANS ARE NOT
 APPLICABLE. THE STATE OF FLORIDA IS NOT UNDER IBC, IMC,
 IPCOR THE 2002 NEC.
 PLEASE SEE THE INCORRECT CODE FOR ENERGY COMPLIANCE IS
 ALSO NOTED.
 2004 FBC W/2007 REVISIONS FOR FLORIDA ENERGY EFFICIENCY
 CODE.
  
 4) NOTE: PLEASE VERIFY LIGHTING CONTROLS FOR ANY NEW
 LOCATIONS FOR SEPARATE SPACES IN BUILDINGS OVER 5K SQ
 FT.
 THIS WOULD APPLY TO NEW BATH ROOMS FOR EXAMPLE: PLEASE
 SEE OTHER AREAS AS NOTED IN SECTIONS BELOW. THESE NEED
 TO MEET *MINIMUM PRESCRIPTIVE REQUIREMENTS*.
 13-415.1.ABC.1.1, .1.2 AND .1.3
  
 5) NOTE: PLEASE SEE 13-415.2, 13-415.1.ABC.1.1, .1.2
 FOR MINIMUM PERFORMANCE CALCULATIONS.
  
 6) NOTE: PLEASE KNOW THIS IS FOR INFORMATIONAL PURPOSE.
 A CORRECTION NOTICE WAS ISSUED FOR THE LOCATION OF THE
 GENERATOR WHICH IS NOT PERMITTED IN THE MAIN ELECTRICAL
 ROOM. THIS IS A LIFE SAFETY AND FIRE HAZARD.
 PLEASE BE AWARE.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 ** IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-08-14 Cont ID  
Sent By mawillia Date 2008-08-14 Time 15:40 Rev Time 0.00
Received By mawillia Date 2008-08-14 Time 15:00 Sent To  
Notes
2008-08-14 15:35:48*****APPROVED*****
  
  
 PLAN SHEETS LS-1 AND LS-2 WERE STAMPED, INITIALED, AND
 DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2008-07-15 Cont ID  
Sent By mwennerg Date 2008-07-15 Time 13:37 Rev Time 0.00
Received By mwennerg Date 2008-07-15 Time 13:37 Sent To  
Notes
2008-07-15 13:42:49PLANS OK
  
 COMMENTS FROM FIRST FIRE REVIEW HAVE BEEN ADDRESSED.
 PLANS WILL REMAIN IN FAILED STATUS UNTIL PLAN REVIEW AT
 TIME OF PERMITTING.
  
 PLANS ARE SUBMITTED FOR PLAN REVIEW ONLY AND NOT FOR
 PERMIT. PLEASE SEE FOLLOWING:
  
 1) SEPARATE SHOP DRAWINGS AND PERMITS WILL BE REQUIRED
 FOR FIRE SPRINKLER AND FIRE ALARM REMODEL.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-05-22 Cont ID  
Sent By mawillia Date 2008-05-22 Time 16:44 Rev Time 0.00
Received By mawillia Date 2008-05-22 Time 15:35 Sent To  
Notes
2008-05-22 16:43:59*****DENIED*****
  
  
 1. IN ADDITION TO THE FIRE CODE (FLORIDA FIRE
 PREVENTION CODE 2004) LISTED ON SHEET T-1, NFPA 101,
 LIFE SAFETY CODE, 2003 EDITION SHALL BE REFERENCED.
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FORM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 4.THE SCOPE OF WORK SHALL NOT HINDER OR INTERFERE
 WITH ACCESS TO OR EGRESS FROM THE PROPERTY OR OTHER
 TENANT SPACES IN THE PALM COAST SHOPPING PLAZA.
  
 5.WILL THE BUILDING OR PORTION OF THE BUILDING BE
 OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATIONS, OR
 ADDITION?
  
 6.SHOW EMERGENCY LIGHTING FOR THIS FACILITY.
  
 7.SPECITY INTERIOR WALL AND CEILING FINISH MATERIALS
 IN TERMS OF CLASS A OR CLASS B.
  
 8.PROVIDE A LAYOUT OF THE FIRE ALARM SYTEM DEVICES
 FOR THE BUILDING IN RELATION TO THE NEW SCOPE OF WORK.
  
 9.PROVIDE A LAYOUT OF THE FIRE SPRINKLER HEADS FOR
 THE BUILDING IN RELATION TO THE NEW SCOPE OF WORK.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET
 EACH ITEM WAS ADDRESSED
  
  
 CAPT.MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  

Review Stop G GAS REVIEW
Rev No 4 Status P Date 2008-08-21 Cont ID  
Sent By kstevens Date 2008-08-21 Time 09:51 Rev Time 0.00
Received By kstevens Date 2008-08-21 Time 09:51 Sent To E
Notes
2008-08-21 09:52:21SEPARATE GAS PERMIT REQUIRED

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2008-08-05 Cont ID  
Sent By kstevens Date 2008-08-05 Time 11:04 Rev Time 0.00
Received By kstevens Date 2008-08-05 Time 11:04 Sent To  
Notes
2008-08-05 11:05:55GAS PLANS APPROVED--SEPARATE PERMIT REQUIRED--
 STATUS WILL CHANGE WHEN APPLICATION FOR PERMIT
 SUBMITTED.

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2008-07-10 Cont ID  
Sent By kstevens Date 2008-07-10 Time 13:29 Rev Time 0.00
Received By kstevens Date 2008-07-10 Time 13:29 Sent To  
Notes
2008-07-10 13:31:00DENIED
 REFERENCE: FBC-2004 FUEL GAS W/2007 AMENDMENTS
  
  
 ****FROM PREVIOUS REVEIW:
  
 1. SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT
 THE FOLLOWING INFORMATION FOR PERMIT:
  
 A. OK
  
 B. TYPE OF GAS, (LP OR NATURAL).
 ****RESPONSE NOTED, BUT GAS TYPE NOT INDICATED.
  
 C. OK
 D. OK
 E. OK
 F. OK
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2008-05-03 Cont ID  
Sent By kstevens Date 2008-05-03 Time 11:50 Rev Time 0.00
Received By kstevens Date 2008-05-03 Time 11:50 Sent To  
Notes
2008-07-10 11:52:43DENIED
 REFERENCE: FBC-2004 FUEL GAS W/2007 AMENDMENTS
  
 1. SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT
 THE FOLLOWING INFORMATION FOR PERMIT:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE. INDICATE THE LENGTH OF PIPING FROM THE
 GAS METER TO THE GENERATOR.
  
 B. TYPE OF GAS, (LP OR NATURAL).
  
 C. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33). ALSO INDICATE THE BTU LOAD FOR THE
 GENERATOR.
  
 D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2. (NEW EQUIPMENT).
  
 E. INDICATE THE PIPE SIZE FROM THE METER TO THE FIRST
 TEE AND THE EXISTING PIPE SIZE TO THE GENERATOR.
  
 F. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE. PLEASE
 INDICATE EACH VALVE AND UNION ON RISER.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-12-30 Cont ID  
Sent By adarroug Date 2008-12-30 Time 10:37 Rev Time 0.00
Received By adarroug Date 2008-12-30 Time 10:36 Sent To P
Notes
2008-12-30 10:37:23TO "P" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-12-23 Cont ID  
Sent By adarroug Date 2008-12-23 Time 10:01 Rev Time 0.00
Received By adarroug Date 2008-12-23 Time 10:01 Sent To  
Notes
2008-12-23 10:05:24TO "COMM" BD#29

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-11-21 Cont ID  
Sent By adarroug Date 2008-11-21 Time 11:32 Rev Time 0.00
Received By adarroug Date 2008-11-21 Time 11:32 Sent To M
Notes
2008-11-21 11:33:20TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-08-20 Cont ID  
Sent By adarroug Date 2008-08-20 Time 15:02 Rev Time 0.00
Received By adarroug Date 2008-08-20 Time 15:02 Sent To  
Notes
2008-08-20 15:02:44TO "KSTEVENS" DESK/RESUB--PER "LMARTINEZ"

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-28 Cont ID  
Sent By adarroug Date 2008-07-28 Time 16:45 Rev Time 0.00
Received By adarroug Date 2008-07-28 Time 16:45 Sent To  
Notes
2008-07-28 16:49:39TO "COMM" BD#36

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-06-11 Cont ID  
Sent By adarroug Date 2008-06-11 Time 09:10 Rev Time 0.00
Received By adarroug Date 2008-06-11 Time 09:10 Sent To  
Notes
2008-06-11 09:16:26TO "COMM" BD#54

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-05-22 Cont ID  
Sent By mawillia Date 2008-05-22 Time 15:35 Rev Time 0.00
Received By mawillia Date 2008-04-22 Time 14:38 Sent To  
Notes
2008-04-25 14:39:08TO "COMM" BD#63

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2009-01-28 Cont ID  
Sent By hmoser Date 2009-01-28 Time 15:17 Rev Time 0.00
Received By hmoser Date 2009-01-28 Time 15:17 Sent To  
Notes
2009-01-28 15:18:23REVISED PAGE S-1

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2008-11-24 Cont ID  
Sent By rregueir Date 2008-11-24 Time 21:28 Rev Time 0.00
Received By rregueir Date 2008-11-24 Time 21:27 Sent To PC
Notes
2008-11-24 21:28:00REVISED M1 AND M2

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-08-08 Cont ID  
Sent By rregueir Date 2008-08-08 Time 10:54 Rev Time 0.00
Received By rregueir Date 2008-08-08 Time 10:28 Sent To  
Notes
2008-08-08 10:54:38*****************PROVISO****************
 OUTDOOR APPLIANCES, SUCH AS EXHAUST AND SUPPLY FANS,
 ARE DESIGNED TO RESIST WIND PRESSURES IN ACCORDANCE
 WITH FBCM 301.13.SUPPORTING DOCUMENTATION FROM THE
 APPLIANCE MANUFACTURER SHALL BE SUBMITTED FOR REVIEW
 PRIOR TO FIRST INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-07-01 Cont ID  
Sent By rregueir Date 2008-07-01 Time 16:35 Rev Time 0.00
Received By rregueir Date 2008-07-01 Time 16:26 Sent To  
Notes
2008-07-01 16:32:47REVIEW #: 2ND **PLAN CHECK ONLY**
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE AND
 STAMPED. REVIEW WILL REMIAN IN FAIL STATUS UNTIL PERMIT
 APPLICATION IS SUBMITTED. ALSO, SEE PROVISO ITEM
 BELOW:
  
 *****************PROVISO****************
 OUTDOOR APPLIANCES, SUCH AS EXHAUST AND SUPPLY FANS,
 ARE DESIGNED TO RESIST WIND PRESSURES IN ACCORDANCE
 WITH FBCM 301.13.SUPPORTING DOCUMENTATION FROM THE
 APPLIANCE MANUFACTURER SHALL BE SUBMITTED FOR REVIEW
 PRIOR TO FIRST INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-05-13 Cont ID  
Sent By rregueir Date 2008-05-13 Time 15:40 Rev Time 0.00
Received By rregueir Date 2008-05-13 Time 08:19 Sent To  
Notes
2008-05-13 15:40:41REVIEW #: 1ST **PLAN CHECK ONLY**
 ACTION:
  
 THESE PLANS WERE REVIEWED UNDER THE FOLLOWING CODES:
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 REVIEW COMMENTS:
  
 1. PLEASE PROVIDE CLEAR DELINEATION OF WHAT DUCTWORK IS
 NEW AND WHAT DUCTWORK IS EXISTING TO REMAIN.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE IN ACCORDANCE WITH FBCB
 106.1.1.
  
 2. CONSTRUCTION NOTE #1 INDICATES THAT AN EXISTING
 STEAM HOOD IS TO REMAIN IN THE DELI AREA. PAGE A-1
 INDICATES A 6-BURNER STOVE AT THIS LOCATION. A TYPE I
 HOOD IS REQUIRED AT THIS LOCATION IN ACCORDANCE WITH
 FBCM 507.2.1. PLEASE SHOW MEANS AND LOCATION OF
 COMMERCIAL KITCHEN EXHAUST AS REQUIRED IN ACCORDANCE
 WITH FBCM 507.2.
  
 3. PAGE A-1 INDICATES A RELOCATED EXISTING
 ROTISSERIE/CONVECTION OVEN AGAINST THE EAST WALL IN THE
 DELI. PAGE M-1 DOES NOT SHOW ANY TYPE OF HOOD OVER THIS
 APPLIANCE. PLEASE SHOW MEANS AND LOCATION OF COMMERCIAL
 KITCHEN EXHAUST AS REQUIRED IN ACCORDANCE WITH FBCM
 507.2.
  
 4. HOOD SCHEDULE ON PG M-2 SHOWS H-1 AND H-2 BUT THERE
 IS A DETAIL FOR A HOOD #3 ON THIS PAGE. PLEASE CLARIFY
 THE NUMBER OF HOODS ALONG WITH LOCATIONS AND
 SPECIFICATIONS. FBCM 507.1, FBCB 106.1.1.
  
 5. HOOD SUPPLY/EXHAUST FAN DETAIL ON PG M-2: MECHANICAL
 EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO
 WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND
 PRESSURES ON THE EQUIPMENT AND THE SUPPORTS AS
 DETERMINED IN ACCORDANCE WITH FBCM 301.13 AND FBCB
 1609. THE FOLLOWING IS REQUIRED: DETAILS WITH
 SUPPORTING WIND LOAD CALCULATIONS FOR NEW CURB AND DUCT
 SUPPORT ATTACHMENTS TO STRUCTURE, APPLIANCE ATTACHMENTS
 TO CURBS AND MANUFACTURER?S SUBMITTAL DATA SHOWING THE
 NEW APPLIANCES ARE DESIGNED AND CONSTRUCTED TO RESIST
 ANTICIPATED WIND PRESSURES IN ACCORDANCE WITH THIS
 SECTION.
  
 NOTE: SEPARATE PERMITS REQUIRED FOR KITCHEN HOOD, HOOD
 SUPPRESSION AND REFRIGERATION SYSTEMS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2009-01-26 Cont ID  
Sent By lwagner Date 2009-01-26 Time 10:47 Rev Time 0.00
Received By lwagner Date 2009-01-26 Time 10:46 Sent To  
Notes
2009-01-26 10:47:19LETTER FOR FASTENING ROOF BRACKETS- OK

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-08-21 Cont ID  
Sent By kstevens Date 2008-08-21 Time 09:51 Rev Time 0.00
Received By kstevens Date 2008-08-21 Time 09:51 Sent To E
Notes
2008-08-21 09:52:42SEPARATE PLUMBING PERMIT REQUIRED

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-08-05 Cont ID  
Sent By kstevens Date 2008-08-05 Time 11:03 Rev Time 0.00
Received By kstevens Date 2008-08-05 Time 11:03 Sent To  
Notes
2008-08-05 12:57:28PLANS APPROVED--STATUS WILL CHANGE WHEN PERMIT
 APPLICATION SUBMITTED.

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-07-10 Cont ID  
Sent By kstevens Date 2008-07-10 Time 12:06 Rev Time 0.00
Received By kstevens Date 2008-07-10 Time 11:53 Sent To  
Notes
2008-07-10 13:28:56DENIED
 REFERENCE: FBC-2004 PLUMBING W/2007 AMENDMENTS
 FBC-2004 FUEL GAS W/2007 AMENDMENTS
 FBC-2004 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUES
 CITY WPB MUNICIPAL CODE
  
 ****FROM PREVIOUS REVEIW:
  
 1. OK
  
 2. ALL PME & SPC SHEETS SHALL INCLUDE THE CERTIFICATE
 OF AUTHORIZATION FOR THE ENGINEERING COMPANY IN THE
 TITLE BLOCK OF EACH SHEET. ALSO THE ADDRESS FOR
 CUBELLIS INC IN INDICATED AS 711 ATLANTIC AVENUE BOSTON
 MA. ON THE FLORIDA STATE DBPR WEBSITE WHICH DOES NOT
 REFLECT THE ADDRESS INDICATED IN THE TITLE BLOCK OF
 EACH SHEET. (97 LIBBEY INDUSTRIAL PARKWAY WEYMOUTH MA).
 PLEASE UPDATE THE TITLE BLOCK OR THE DBPR WEBSITE PRIOR
 TO RESUBMITTING TO THE CITY FOR REVIEW. (SEE ATTACHED
 SHEET). FAC 61G15-23.002(2) & FS 471.2055. ****RESPONSE
 NOTED, BUT THE ADDRESS LISTED FOR CA NUMBER 27279 IS
 711 ATLANTIC AVE BOSTON WHICH DOES NOT REFLECT THE
 ADDRESS IN THE TITLE BLOCKS OF THE PME OR SPC SHEETS.
 (281 SUMMER ST OR 1800 ELLER DR).
  
 3. OK
  
 4. SHT P-2 DRAWING NOTES #11 AND WASTE PIPING PLAN
 PIPING TO & INCLUDING THE GREASE INTERCEPTOR ARE NOT
 APPROVED. ARTICLE III SECTION 90-124(7)(B). PLEASE
 CONNECT ROTISSERIE TO EXISTING GREASE SYSTEM TO CATCH
 MINIMUM AMOUNT OF GREASE. THE ROTISSERIE SHALL DRAIN
 INTO A CONTAINER WHICH SHALL CATCH THE GREASE AND BE
 DISPOSED OF PROPERLY WITH OUT DRAINING INTO THE
 SYSTEM.
 ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES
 NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD
 PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES
 "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO
 BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH
 THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER
 INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR
 GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER
 SECTION 802.3.2.
  
 5. OK
 6. OK
  
 7. SHT P-5 GREASE INTERCEPTOR AT ROTISSERIE IS NOT
 APPROVED. ARTICLE III SECTION 90-124(7)(B).
 ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES
 NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD
 PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES
 "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO
 BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH
 THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER
 INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR
 GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER
 SECTION 802.3.2.
  
 8. OK
 9. OK
  
 10 SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT
 THE FOLLOWING INFORMATION FOR PERMIT:
  
 A. OK
  
 B. TYPE OF GAS, (LP OR NATURAL).
 ****RESPONSE NOTED, BUT GAS TYPE NOT INDICATED.
  
 C. OK
 D. OK
 E. OK
 F. OK
  
 11. SHT P-7 THE PLUMBING LEGEND AND SCHEDULE #50 AS
 WELL AS THE GREASE TRAP DETAIL ARE NOT APPROVED.
 ARTICLE III SECTION 90-124(7)(B). PLEASE DELETE FROM
 PLANS.
 ****RESPONSE NOTED, BUT THE CITY MUNICIPAL CODE DOES
 NOT ALLOW FOR THE GREASE TRAP/INTERCEPTOR IN THE FOOD
 PREP AREA. ARTICLE III SECTION 90-124(7)(B) STATES
 "GREASE INTERCEPTORS (SEPARATORS, GREASE TRAPS) ARE TO
 BE INSTALLED OUTSIDE OF THE FOOD PREPARATION AREA WITH
 THE DISHWASHER VIA A SEPARATE LINE. UPON FURTHER
 INVESTIGATION, THE ROTISSERIE SHALL DRAIN WITH AN AIR
 GAP INTO THE GREASE WASTE SYSTEM VIA A FLOOR SINK PER
 SECTION 802.3.2.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-05-03 Cont ID  
Sent By kstevens Date 2008-05-03 Time 16:43 Rev Time 0.00
Received By kstevens Date 2008-05-03 Time 16:43 Sent To  
Notes
2008-05-03 17:16:34DENIED
 REFERENCE: FBC-2004 PLUMBING W/2007 AMENDMENTS
 FBC-2004 FUEL GAS W/2007 AMENDMENTS
 FBC-2004 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUES
 CITY WPB MUNICIPAL CODE
  
 1. ALL ARCHITECTURAL SHEETS. CUBELLIS'S TITLE BLOCK
 ADDRESS DOES NOT REFLECT THE ADDRESS OF RECORD ON THE
 STATE OF FLORIDA DBPR WEBSITE.(97 LIBBEY INDUSTRIAL
 PARKWAY WEYMOUTH MA. ON TITLE BLOCK--1800 ELLERY DR
 BOSTON MA. ON DBPR WEBSITE). PLEASE UPDATE THE TITLE
 BLOCK OR THE DBPR WEBSITE PRIOR TO RESUBMITTING TO THE
 CITY FOR REVIEW. (SEE ATTACHED SHEET). FAC
 61G1-16.004(1) & FS 481.025.
  
 2. ALL PME & SPC SHEETS SHALL INCLUDE THE CERTIFICATE
 OF AUTHORIZATION FOR THE ENGINEERING COMPANY IN THE
 TITLE BLOCK OF EACH SHEET. ALSO THE ADDRESS FOR
 CUBELLIS INC IN INDICATED AS 711 ATLANTIC AVENUE BOSTON
 MA. ON THE FLORIDA STATE DBPR WEBSITE WHICH DOES NOT
 REFLECT THE ADDRESS INDICATED IN THE TITLE BLOCK OF
 EACH SHEET. (97 LIBBEY INDUSTRIAL PARKWAY WEYMOUTH MA).
 PLEASE UPDATE THE TITLE BLOCK OR THE DBPR WEBSITE PRIOR
 TO RESUBMITTING TO THE CITY FOR REVIEW. (SEE ATTACHED
 SHEET). FAC 61G15-23.002(2) & FS 471.2055
  
 3. SHT P-1 REFRIGERATION TUBING PLAN. WORK INDICATED IN
 MECHANICAL AND SHALL BE SUBMITTED IN THE MECHANICAL
 PLANS, NOT THE PLUMBING PLANS. PLEASE SUBMIT UNDER
 MECHANICAL PLANS. FS 489.
  
 4. SHT P-2 DRAWING NOTES #11 AND WASTE PIPING PLAN
 PIPING TO & INCLUDING THE GREASE INTERCEPTOR ARE NOT
 APPROVED. ARTICLE III SECTION 90-124(7)(B). PLEASE
 CONNECT ROTISSERIE TO EXISTING GREASE SYSTEM TO CATCH
 MINIMUM AMOUNT OF GREASE. THE ROTISSERIE SHALL DRAIN
 INTO A CONTAINER WHICH SHALL CATCH THE GREASE AND BE
 DISPOSED OF PROPERLY WITH OUT DRAINING INTO THE
 SYSTEM.
  
 5. SHT P-3 WATER DISTRIBUTION NOTE #7 WATER HAMMER
 ARRESTORS SHALL BE LOCATED NEAR THE FIXTURES, IN AN
 "EFFECTIVE RANGE" NOT IN THE CEILING. SECTION 604.9 &
 PDI-WH 201.
  
 6. SHT P-5 SHOW THE CHANGE IN LOCATION FOR THE WATER
 CLOSET AND THE LAV IN THE ACCESSIBLE STALLS ON THE
 SANITARY RISER DIAGRAM. SECTION 106.3.5.1.3.
  
 7. SHT P-5 GREASE INTERCEPTOR AT ROTISSERIE IS NOT
 APPROVED. ARTICLE III SECTION 90-124(7)(B).
  
 8. SHT P-5 INDICATE WHERE THE BRANCH LINE CONNECTS TO
 THE BUILDING GREASE DRAIN LINE DOWNSTREAM OF THE
 ROTISSERIE. SECTION 106.1.2.
  
 9. SHT P-6 SHOW THE CHANGE IN LOCATION FOR THE WATER
 CLOSET AND THE LAV IN THE ACCESSIBLE STALLS ON THE
 WATER RISER DIAGRAM. SECTION 106.3.5.1.3.
  
 10 SHT P-6 A SEPARATE GAS PERMIT IS REQUIRED. SUBMIT
 THE FOLLOWING INFORMATION FOR PERMIT:
  
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE. INDICATE THE LENGTH OF PIPING FROM THE
 GAS METER TO THE GENERATOR.
  
 B. TYPE OF GAS, (LP OR NATURAL).
  
 C. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33). ALSO INDICATE THE BTU LOAD FOR THE
 GENERATOR.
  
 D. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2. (NEW EQUIPMENT).
  
 E. INDICATE THE PIPE SIZE FROM THE METER TO THE FIRST
 TEE AND THE EXISTING PIPE SIZE TO THE GENERATOR.
  
 F. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE. PLEASE
 INDICATE EACH VALVE AND UNION ON RISER.
  
 11. SHT P-7 THE PLUMBING LEGEND AND SCHEDULE #50 AS
 WELL AS THE GREASE TRAP DETAIL ARE NOT APPROVED.
 ARTICLE III SECTION 90-124(7)(B). PLEASE DELETE FROM
 PLANS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-07-14 Cont ID  
Sent By kdfreema Date 2008-07-09 Time 17:54 Rev Time 0.00
Received By kdfreema Date 2008-07-09 Time 17:54 Sent To  
Notes
2008-07-09 18:00:01NOT REQUIRED


Account Summary | Usage Policy | Privacy Policy