| Plan Review Stops For Permit 08040541 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-09 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-09 |
Time |
13:32 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-29 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-29 |
Time |
11:02 |
Sent To |
PC |
|
| Notes |
| 2008-05-29 11:36:21 | BUILDING PLAN REVIEW | | | PERMIT: 08040541 | | | ADD: 1900 CONSULATE PLACE #403 | | | CONT: SAARI CONSTRUCTION INC. | | | TEL: (561)588-0720 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: REV. | | | ACTION: DENIED | | | | | | 1)INDICATE ON THE PLANS THE HEIGHT OF THE NEW FURRED | | | CEILING IN BOTH AREAS WHERE IT WILL BE CONSTRUCTED. ANY | | | ROOM WITH A FURRED CEILING SHALL BE REQUIRED TO HAVE A | | | MINIMUM HEIGHT 7 FEET FBC 1208.1. PLEASE ALSO SEE FBC | | | SECTION 1208 FOR MORE INFORMATION. | | | | | | 2)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-05 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-05 |
Time |
11:54 |
Sent To |
PC |
|
| Notes |
| 2008-05-05 12:29:04 | | | | PROVISOR: | | | 712.4.1.2 THROUGH PENETRATIONS SHALL BE PROTECTED BY AN | | | APPROVED THROUGH-PENETRATION FIRE STOP SYSTEM INSTALLED | | | AND TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479, | | | WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 | | | INCH OF WATER. THE SYSTEM SHALL HAVE AN F RATING AND A | | | T RATING OF NOT LESS THAN 1 HOUR BUT NOT LESS THAN THE | | | REQUIRED RATING OF THE FLOOR PENETRATED. PLEASE | | | INDICATE THE UL ASSEMBLY NUMBER FOR THE FLOOR | | | PENETRATION WHERE THE PLUMBING PIPES WILL BE REMOVED | | | AND CAPED. WHERE ANY PIPES ARE REMOVED FROM THE FLOOR | | | CEILING/ASSEMBLY, THE HOLES SHALL BE SEALED WITH A UL | | | ASSEMBLY WHICH SHALL MAINTAIN THE FLOOR RATING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-29 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-29 |
Time |
08:17 |
Sent To |
PC |
|
| Notes |
| 2008-04-29 13:00:23 | BUILDING PLAN REVIEW | | | PERMIT: 08040541 | | | ADD: 1900 CONSULATE PLACE #406 | | | CONT: SAARI CONSTRUCTION INC. | | | TEL: (561)588-0720 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 4-29-08 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 2)2004 FBC EXISTING | | | 301.5 THE DESIGN PROFESSIONAL OR AN OWNER MUST ELECT | | | ONE OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT | | | TO SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | 3)THE CONTRACTOR ON THE PERMIT APPLICATION IS A CBC | | | CONTRACTOR WHO IS NOT ALLOWED TO DO ANY WORK PERTAINING | | | TO THE STRUCTURAL WALLS OF THE BUILDING. A CERTIFIED | | | GENERAL CONTRACTOR OR A CERTIFIED FIREPROOFING COMPANY | | | SHALL APPLY FOR A SEPARATE APPLICATION TO SEAL ALL | | | FLOOR/CEILING PENETRATIONS. | | | | | | 4)712.4.1.2 THROUGH PENETRATIONS SHALL BE PROTECTED | | | BY AN APPROVED THROUGH-PENETRATION FIRE STOP SYSTEM | | | INSTALLED AND TESTED IN ACCORDANCE WITH ASTM E 814 OR | | | UL 1479, WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL | | | OF 0.01 INCH OF WATER. THE SYSTEM SHALL HAVE AN F | | | RATING AND A T RATING OF NOT LESS THAN 1 HOUR BUT NOT | | | LESS THAN THE REQUIRED RATING OF THE FLOOR PENETRATED. | | | PLEASE INDICATE THE UL ASSEMBLY NUMBER FOR THE FLOOR | | | PENETRATION WHERE THE PLUMBING PIPES WILL BE REMOVED | | | AND CAPED. WHERE ANY PIPES ARE REMOVED FROM THE FLOOR | | | CEILING/ASSEMBLY, THE HOLES SHALL BE SEALED WITH A UL | | | ASSEMBLY WHICH SHALL MAINTAIN THE FLOOR RATING. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-05 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-05 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2008-06-05 14:17:32 | | | | | | | | | | FILE COPY WITH THE REVISION IN BIN #9./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-21 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-21 |
Time |
15:39 |
Sent To |
B |
|
| Notes |
| 2008-05-21 15:59:34 | | | | | | | | | | REVISION DENIED | | | | | | 1} THE REVISION SUBMITTED INDICATES A COMPLETE REWIRE | | | OF THE UNIT, IF NOT DIFFERENTIATE NEW FROM EXISTING. | | | | | | 2} THE VALUE MUST INCLUDE THE TOTAL COST OF LABOR AND | | | MATERIAL. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES PER 108.3 FBC AS AMENDED.ADJUST THE VALUE | | | TO INCLUDE ALL ADDED WORK UNDER THIS REVISION AT THE | | | PERMIT CLERK?S DESK, AND PAY THE DIFFERENCE IN FEES | | | PRIOR TO RESUBMITTING. | | | | | | 3} KITCHEN RECEPTACLE SPACING MUST COMPLY WITH | | | 210.52(A), 210.52(C), AND 210.8(A)(6) GFI. SEE | | | COUNTERTOP ADJACENT TO THE "REF/FRZ".\ | | | | | | 4} INDICATE IF THE FLOOR RECEPTACLE IN BEDROOM #2 IS | | | NEW OR EXISTING. IF NEW THE FLOOR MUST BE X-RAYED PRIOR | | | TO MAKING ANY CUTS AND AN ENGINEER MUST VERIFY THE | | | INSTALLATION WILL NOT WEAKEN THE STRUCTURAL INTEGRITY | | | OR RATING OF THE FLOOR. INDICATE HOW THIS OUTLET WILL | | | BE FED, AND FROM WHERE. | | | | | | PROVIDE A WRITTEN RESPONSE, PROVIDE ONE COPY OF THE | | | OLD PLANS WHEN RESUBMITTING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-21 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-21 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-28 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-28 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-04 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-04 |
Time |
10:43 |
Sent To |
E |
|
| Notes |
| 2008-06-04 10:43:41 | TO "BOB"#9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-20 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-20 |
Time |
09:00 |
Sent To |
B |
|
| Notes |
| 2008-05-20 09:01:13 | TO "MJACOB" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-30 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-30 |
Time |
14:11 |
Sent To |
B |
|
| Notes |
| 2008-04-30 14:11:51 | TO "MJACOBS" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-04-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-21 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2008-04-21 12:42:22 | TO "BOB"#2 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-22 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-22 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2008-04-22 16:10:42 | ******PROVISO****** | | | PER FBC-2004 PLUMBING, SECTION 704.5 | | | DEAD ENDS: IN THE INSTALLATION OR | | | REMOVAL OF ANY PART OF A DRAINAGE | | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | | A PLUMBING PERMIT REQUIRED AND | | | INSPECTION REQUIRED OF DEMO WORK PRIOR | | | TO COVERING DEMO WORK WITH FINNISH | | | WALLS, CIELINGS, OR POURED CONCRETE | | | SLABS. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-24 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-24 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2008-04-24 11:01:25 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|