Plan Review Details - Permit 08040527
| Plan Review Stops For Permit 08040527 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-28 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-28 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2008-04-28 10:38:14 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1. DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS481. | | | | | | 2.SEE FBC R 4101.17.ENGINEER SPECIFICIES A CODE | | | SECTION, BUT SHOULD PROVIDE DESIGN CRITERIA ON THE PLAN | | | (EITHER SPECIFIC TO THIS JOB OR A GENERAL NOTE). | | | | | | 3.IN THE AREA OVER 5' DEEP, SHOW HOW THIS JOB WILL | | | COMPLY WITH FBC4101.18. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-21 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-21 |
Time |
14:55 |
Sent To |
P |
|
| Notes |
| 2008-04-21 15:23:05 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | 1} PROVIDE A SCHEMATIC OF THE POOL WIRING AND | | | EQUIPMENT. | | | | | | 2} PROVIDE A LOAD CALCULATION FOR THE ELECTRICAL | | | SERVICE, INDICATING ALL EXISTING LOADS AND ALL LOADS TO | | | BE IMPOSED BY THE ADDITION OF THE NEW EQUIPMENT. 215.5 | | | NEC 2005.INDICATE THE RATING OF THE EXISTING SERVICE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2008-04-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-23 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-23 |
Time |
15:35 |
Sent To |
B |
|
| Notes |
| 2008-04-23 15:38:16 | NOTE: POOL HAS BOTH AN ELECTRIC HEAT PUMP AND A GAS | | | POOL HEATER. | | | | | | CONTRACTOR INFORMATION ONLY | | | NOTE: GAS PERMIT REQUIRED. LICENSED GAS OR PLUMBING | | | CONTRACTOR TO SUBMIT PLANS WITH PERMIT APPLICATION. ALL | | | GAS INSPECTIONS TO BE COMPLETE BEFORE FINAL POOL | | | INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2008-04-18 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2008-04-18 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2008-04-18 14:40:34 | HISTORIC APPROVED BY GJUDGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-28 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-18 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2008-04-18 16:38:36 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-23 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-23 |
Time |
15:26 |
Sent To |
G |
|
| Notes |
| 2008-04-23 15:35:29 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1) FBC-2004 SEC. 424.2.7.1, OR FBCR-2004 SEC.R4101.7.1 | | | POOL CIRCULATING PUMPS | | | SHALL BE EQUIPPED ON THE INLET SIDE WITH | | | AN APPROVED TYPE HAIR AND LINT STRAINER | | | WHEN USED WITH A PRESSURE FILTER. | | | (DETAIL, MANUFACTURE SPEC SHEET OR ADD TO NOTES) | | | | | | 2) FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | *THE MANUFACTURER'S SPEC SHEET FOR THE HEAT PUMP ARE | | | NOT INDICATING A LISTING AND AN ONLINE SEARCH BY THIS | | | PLAN REVIEWER FAILED TO FIND ONE AS WELL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-21 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-21 |
Time |
08:48 |
Sent To |
E |
|
| Notes |
| 2008-04-21 09:01:31 | ***FAILED*** | | | | | | | | | 1)INDICATE SETBACK DIMENSIONS OF ALL PROPOSED | | | IMPROVEMENTS FROM WATERS' EDGE TO PROPERTY LINES. | | | | | | 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED POOL | | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | 3)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | | THE MINIMUM STANDARDS PROVIDED BELOW. | | | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C): | | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
|