| Plan Review Stops For Permit 08040437 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-08-26 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-08-26 |
Time |
12:51 |
Sent To |
|
|
| Notes |
| 2008-08-26 12:52:22 | REVISION PAGES A-1.0 AND A-2.0 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-06 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-06 |
Time |
11:22 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-05-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-15 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-15 |
Time |
09:20 |
Sent To |
PC |
|
| Notes |
| 2008-05-15 11:22:50 | BUILDING PLAN REVIEW | | | PERMIT: 08040437 | | | ADD: 101 N. CLEMATIS ST. | | | CONT: HALE BUILDING CO. | | | TEL: (910)313-2468 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 4-23-08 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 2) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3) OK | | | | | | **NO RESPONSE NOT ADDRESSED** | | | 4)2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | **NO RESPONSE NOT ADDRESSED** | | | 5)FIRE SPRINKLER PLANS REQUIRED SHOWING HOW THE | | | RENOVATION AFFECTS THE FIRE SPRINKLER LAYOUT. THIS | | | INFORMATION CAN BE SHOWN ON THE CEILING PLANS. FBC | | | 106.3.5.1.1(5) | | | | | | 6)OK | | | | | | **NO RESPONSE NOT ADDRESSED** | | | 7)SHEET A-7.0 SHOWS A RECEPTIONIST DESK HOWEVER, THE | | | DRAWINGS DO NOT CLEARLY SHOW WHERE THE RECEPTIONIST | | | WILL BE LOCATED BEHIND THIS DESK. CLARIFY. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-23 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-22 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2008-04-23 11:39:04 | BUILDING PLAN REVIEW | | | PERMIT: 08040437 | | | ADD: 101 N. CLEMATIS ST. | | | CONT: HALE BUILDING CO. | | | TEL: (910)313-2468 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 4-23-08 | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 2) INFORMATIONAL FL S S 713.13 NOTICE OF COMMENCEMENT, | | | TO BE FILED WITH THE CLERK OF THE COURT. NOTE: | | | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE 2007 SUPPLEMENTS. | | | | | | 4)2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | 5)FIRE SPRINKLER PLANS REQUIRED SHOWING HOW THE | | | RENOVATION AFFECTS THE FIRE SPRINKLER LAYOUT. THIS | | | INFORMATION CAN BE SHOWN ON THE CEILING PLANS. FBC | | | 106.3.5.1.1(5) | | | | | | 6)THE NOTES FOR THE DEMOLITION DRAWINGS SHALL BE | | | SEPARATED FROM THE PROPOSED DRAWINGS TO AVOID CONFUSION | | | WITH THE CONSTRUCTION DOCUMENTS. THE NOTES MAKE | | | REFERENCE TO A-8 BUT THERE IS NOT SHEET OR DETAIL WITH | | | A-8. THE NEW WALL TYPE SYMBOL NEEDS TO BE SHOWN IN THE | | | LEGEND ON THE PLANS. THE NEW DOOR AT OFFICE 203 SHALL | | | BE IDENTIFY WITH ONE OF THE SYMBOL FROM THE DOOR | | | SCHEDULE. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE NATURE AND EXTENT OF THE WORK | | | PROPOSED. FBC106.1.1. | | | | | | 7)SHEET A-7.0 SHOWS A RECEPTIONIST DESK HOWEVER, THE | | | DRAWINGS DO NOT CLEARLY SHOW WHERE THE RECEPTIONIST | | | WILL BE LOCATED BEHIND THIS DESK. CLARIFY. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-08-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-08-28 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-08-27 |
Time |
15:31 |
Sent To |
PC |
|
| Notes |
| 2008-08-27 15:32:41 | | | | | | | CALLED LARRY MAYNARD FOTR INFO 15:30./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-06-03 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-06-03 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-05-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-13 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-13 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2008-05-13 10:20:24 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | 2ND REVIEW, SAME COMMENTS AS THE FIRST REVIEW AS THEIR | | | WAS NO RESPONSE. | | | | | | 1} INDICATE PANEL DESIGNATION AND CIRCUIT NUMBERS FOR | | | DEVICES SHOWN IN ROOMS 201 AND 203. 106.3.5 FBC. | | | | | | 2}AN ELECTRICAL PERMIT IS REQUIRED PER 105.1 FBC AS | | | AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-24 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-24 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2008-04-24 16:09:37 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2005 | | | NEC, NFPA-72 2002, NFPA-101 2003, 2004 FBC AS AMENDED, | | | CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} INDICATE PANEL DESIGNATION AND CIRCUIT NUMBERS FOR | | | DEVICES SHOWN IN ROOMS 201 AND 203. 106.3.5 FBC. | | | | | | 2}AN ELECTRICAL PERMIT IS REQUIRED PER 105.1 FBC AS | | | AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-05-14 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-05-14 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-24 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-24 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2008-04-24 13:25:05 | ***DENIED*** | | | | | | 1) PLEASE MAKE CORRECTIONS TO CODE EDITIONS. WORK TO | | | COMPLY WITH NFPA 101, 2003, NFPA 72, 2002 AND NFPA 13, | | | 2002. SHT AN-1 | | | | | | 2) CONSTRUCTION, ALTERATION AND DEMOLITION TO COMPLY | | | WITH NFPA 241. PLEASE ADD TO CODE REFERENCES. | | | | | | 3) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER AND FIRE ALARM REMODEL. | | | | | | 4) ACCESS CONTROL SYSTEM IS REFERENCED ON SHT AN-2 IN | | | HARDWARE NOTES. NO SUCH EQUIPMENT WAS FOUND ON PLANS OR | | | DOOR SCHEDULE. PLEASE CLARIFY AND IF SYSTEM IS PART OF | | | THE SCOPE OF THIS WORK, SEPARATE SHOP DRAWINGS AND | | | PERMIT ARE REQUIRED. ADDITIONALLY, WORK SHALL COMPLY | | | WITH NFPA 101, SECTION 7.2.1.6.2. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-08-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-20 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-20 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2008-08-25 08:40:11 | TO BOB #4. | | 2008-08-20 16:48:06 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-02 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-02 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2008-06-02 10:35:48 | TO "BOB"#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-12 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-12 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2008-05-12 10:48:35 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-25 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-16 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2008-04-16 16:45:25 | TO "BOB"#8 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-17 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-17 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2008-04-17 13:09:40 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|