| 2008-04-22 16:32:58 | 2004 FBC W/2007 REVISIONS | | | CHANGE OF OCCUPANCY | | | ENCLOSE PORTION OF GARAGE FOR OFFICE | | | | | | DENIED BY BUILDING | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT TWO COPIES OF ENERGY CALCULATIONS AS REQUIRED | | | BY FBC 13-600. THE OWNER/AGENT IS REQUIRED TO SIGN THE | | | FORMS. | | | | | | 3) PROVIDE A WALL SECTION OF THE NEW INTERIOR WALLS | | | INDICATING THE FRAMING MATERIALS, STUD SPACING, | | | INSULATION, DRYWALL THICKNESS, ETC. | | | | | | 4) THE WALL ADJACENT TO THE STORAGE AREA IS REQUIRED TO | | | BE INSULATED. SPECIFY THE R-VALUE OF THE INSULATION IN | | | THE ATTIC, EXTERIOR, COMMON AND ADJACENT WALLS. THE | | | DOOR IN THE ADJACENT WALL IS REQUIRED TO COMPLY WITH | | | FBC 13-603 AND CAN NOT BE HOLLOW CORE. SEE FBC 13-600. | | | | | | 5) SPECIFY ON THE PLANS WHICH WALLS ARE NEW AND WHICH | | | ARE EXISTING. | | | | | | 6) THE PROPOSED OFFICE IS REQUIRED TO COMPLY WITH FAIR | | | HOUSING REQUIREMENT 4 FOR ACCESSIBLE ROUTE AND | | | REQUIREMENT 3 FOR USABLE DOORS. USABLE DOORS ARE | | | REQUIRED TOHAVE A NOMINAL 32" CLEAR OPENING MEASURED | | | FROM THE STOP TO THE FACE OF THE DOOR WHEN OPEN 90 | | | DEGREES. THE FLOOR OF THE OFFICE IS REQUIRED TO BE | | | LEVEL WITH THE EXISTING HABITABLE SPACE. SHOW | | | COMPLIANCE WITH THESE REQUIREMENTS. SHOW THE LOCATIONS | | | OF ANY FLOOR ELEVATION CHANGES ON THE PLANS. THE LIGHT | | | SWITCHES, RECEPTACLES AND CONTROLS ARE REQUIRED TO | | | COMPLY WITH REQUIREMENT 5. SEE FBC CHAPTER 11 PART B | | | FAIR HOUSING. | | | | | | 7) TEST RTW | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-05 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-05 |
Time |
09:26 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-16 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-16 |
Time |
14:22 |
Sent To |
M |
|
| Notes |
| 2008-04-16 14:39:10 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | 1} AN ELECTRICAL PERMIT IS REQUIRED PER 105.1 FBC AS | | | AMENDED. | | | | | | 2} SUBMIT PLANS INDICATING COMPLIANCE WITH SPACING | | | REQUIREMENTS FOR OUTLETS, INCLUDING LIGHTING PER | | | ARTICLE 210, 2005 NEC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-30 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-30 |
Time |
10:34 |
Sent To |
E |
|
| Notes |
| 2008-04-30 10:34:59 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-04-22 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-04-14 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2008-04-14 15:13:48 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-05 |
Time |
13:54 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2008-05-05 |
Time |
13:54 |
Sent To |
P |
|
| Notes |
| 2008-05-05 13:55:49 | PROPOSED SPACE CHANGED ON PLANS AND PERMIT APPLICATION | | | FROM OFFICE TO STORAGE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-16 |
Time |
14:52 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-16 |
Time |
14:52 |
Sent To |
B |
|
| Notes |
| 2008-04-16 15:14:04 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) AS THE PROPOSED OFFICE SPACE HAS NO WINDOWS, A MEANS | | | OW VENTILATION WILL NEED TO BE PROVIDED, SEE 2004 FBC/R | | | R303.1 AND THE EXCEPTIONS. PLEASE CORRECT. | | | | | | 2) PLEASE STATE ON THE PLAN IF THE WATER HEATER IS | | | ELECTRIC OR GAS. IF GAS SEE 2004 FBC/R G2407.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-16 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-16 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-16 |
Time |
10:21 |
Sent To |
E |
|
| Notes |
| 2008-04-16 10:22:27 | INTERIOR WORK ONLY. |
|
|