Plan Review Details - Permit 08040251
| Plan Review Stops For Permit 08040251 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-05-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-05-28 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-05-28 |
Time |
17:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-21 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-21 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2008-04-21 09:12:59 | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.AS THE DISTANCE TO THE PROPERTY LINE IS LESS THAN | | | 6FT, PLEASE PROVIDE INFORMATION ABOUT THE STRUCTURE ON | | | THE ADJACENT PROPERTIES.SHOW THE TOTAL DISTANCE FROM | | | THE SHED TO THE STRUCTURE ON ADJACENT LOTS.RATHER | | | THAN PROVIDING AN EXACT DIMENSION, YOU MAY SHOW THAT IT | | | IS >6FEET IF THIS IS THE CASE.IF LESS THAN 6FT, | | | PLEASE CONTACT ME.FBC R301. | | | | | | 2. SHOW DISTANCE FROM THE HOUSE TO THE PROPOSED SHED. | | | THE SITE PLAN IS NOT CLEAR. | | | | | | 3.THE COVER LETTER DOES NOT MATCH THE DRAWINGS.THE | | | COVER LETTER DOES NOT MATCH THE LETTER ON FILE WITH | | | DCA.THE CORRECT DOCUMENT IS AVAILABLE AT | | | WWW.FLORIDABUILDING.ORG (MANUFACTURED BUILDINGS) OR | | | POSSIBLY FROM THE SHED SUPPLIER. | | | | | | 4.THE PAGE MARKED 7 OF 8 IS NOT A PART OF THE DCA | | | APPROVAL.SOIL ANCHORING IS TO BE A SIGNED, SEALED, | | | DATED ORIGINAL AND MUST INCLUDE WIND DESIGN CRITERIA | | | FBC301 (WIND SPEED AND EXPOSURE CLASSIFICATION) AND | | | GOVERNING CODE. | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-21 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-21 |
Time |
16:38 |
Sent To |
B |
|
| Notes |
| 2008-05-21 16:41:59 | | | | | | | NO ELECTRICAL WORK ON THIS PERMIT, NO WIRING TO THE | | | SHED PER JANETTE BYRD, O/B./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-14 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-14 |
Time |
09:55 |
Sent To |
B |
|
| Notes |
| 2008-04-14 10:02:15 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | 1} SHEET FP1 INDICATES AN OPTIONAL ELECTRICAL PLAN. IF | | | THIS IS THE CORRECT PLAN, INCLUDING A 100 AMP PANEL, | | | SUBMIT AN ELECTRICAL RISER DIAGRAM INDICATING | | | COMPLIANCE WITH 225.31 DISCONNECTING MEANS AND 250.32 | | | FOR GROUNDING ELECTRODE CONDUCTOR. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-19 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-19 |
Time |
09:23 |
Sent To |
Z |
|
| Notes |
| 2008-05-19 09:23:46 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-21 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-10 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2008-04-10 10:43:43 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-05-20 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-05-20 |
Time |
14:48 |
Sent To |
E |
|
| Notes |
| 2008-05-20 14:49:18 | ***APPROVED - RESUB #1*** | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-10 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-10 |
Time |
16:18 |
Sent To |
E |
|
| Notes |
| 2008-04-10 16:21:57 | ***FAILED*** | | | | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT, LEGIBLE | | | SURVEY THAT INDICATES BOTH THE PROPERTY'S ADDRESS AND | | | LEGAL DESCRIPTION. | | | | | | 2)INDICATE THE PROPOSED SHED WITH A PERMANENT | | | UTENSIL SHOWING SETBACK DIMENSIONS TO ALL PROPERTY | | | LINES AND THE SEPARATION DISTANCE FROM THE PRINCIPAL | | | STRUCTURE. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
|