| 2008-04-21 14:51:44 | 2004 FBC W/2007 REVISIONS |
| | ADDITION AND DECK |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL |
| | BE REQUIRED. |
| | |
| | 2) THERE ARE TWO STRUCTURES LOCATED ON THE SAME PARCEL. |
| | THERE WERE PLANS SUBMITTED FOR A SINGLE STORY BUILDING, |
| | A TWO STORY STRUCTURE AND A SITE WALL. THE TITLE BLOCK |
| | ON ALL THREE PLANS ONLY PROVIDE THE OWNER NAME AND |
| | ADDRESS. IN ORDER TO AVOID CONFUSION, PLEASE SPECIFY |
| | THE STRUCTURE TO WHICH THE PLANS APPLY IN THE TITLE |
| | BLOCKS. FBC 106.1* CITY AMENDMENTS. |
| | |
| | TWO STORY STRUCTURE |
| | |
| | 1) ON SHEET A-2 THE SECOND FLOOR FLOOR PLAN SAYS TO SEE |
| | DETAIL C. THERE DOES NOT APPEAR TO BE A DETAIL C |
| | PROVIDED. PLEASE CLARIFY. |
| | |
| | 2) ON SHEET D-1 THE 6 X 6 POSTS IN CONTACT WITH THE |
| | SOIL ARE NOT SPECIFIED AS BEING PRESSURE TREATED ON |
| | SHEET D-1. |
| | |
| | 3) ON SHEET A-2 SECTION A AT THE DECK IS INDICATED ON |
| | THE SECOND FLOOR PLAN. HOWEVER, THERE DOES NOT APPEAR |
| | TO BE A SECTION A PROVIDED. PLEASE CLARIFY. |
| | |
| | 4) SPECIFY HOW THE 2 X 10 FLOOR JOISTS ARE ATTACHED TO |
| | THE (3) 2 X 10S LOCATED ATOP THE 6 X 6 POSTS. FBC |
| | 106.1.2* CITY AMENDMENTS. |
| | |
| | 5) THE SECOND FLOOR PLAN ON A-2 SPECIFIES A 4 PLY 2 X |
| | 10 IN ONE LOCATION AT THE 6 X 6 POSTS AND (3) IN THE |
| | OTHER. PLEASE CLARIFY. |
| | |
| | 6) ON SHEET D-1 PART OF THE TEXT IS MISSING FROM THE |
| | NOTES AT THE LEFT SIDE OF THE PAGE. |
| | |
| | 7) SUBMIT (2)TWO COPIES OF PRODUCT APPROVALS THAT |
| | HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD FOR THE PROJECT. FBC 106.3.3* CITY |
| | AMENDMENTS. |
| | |
| | 8) SUBMIT PRODUCT APPROVALS FOR THE SINGLE HUNG WINDOWS |
| | AS REQUIRED BY DCA RULE 9B-72. |
| | |
| | ONE STORY STRUCTURE |
| | |
| | 1) ON SHEET S-1 THE WALL SECTION SHOWS THE STUCCO |
| | FINISH EXTENDING BELOW GRADE. THIS DOES NOT COMPLY WITH |
| | SECTION 704 INSPECTION FOR TERMITES. IN ORDER TO |
| | PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, |
| | CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL |
| | EARTH GRADE ON THE EXTERIOR OF A BUILDING SHALL NOT BE |
| | LESS THAN 6 INCHES (152 MM). PLEASE CORRECT. |
| | |
| | 2) AT THE ADDITION, SHOW COMPLIANCE WITH R408.1 |
| | VENTILATION. |
| | THE UNDER -FLOOR SPACE BETWEEN THE BOTTOM OF THE FLOOR |
| | JOISTS AND THE EARTH UNDER ANY BUILDING (EXCEPT SPACE |
| | OCCUPIED BY A BASEMENT OR CELLAR) SHALL BE PROVIDED |
| | WITH VENTILATION OPENINGS THROUGH FOUNDATION WALLS OR |
| | EXTERIOR WALLS. THE MINIMUM NET AREA OF VENTILATION |
| | OPENINGS SHALL NOT BE LESS THAN 1 SQUARE FOOT FOR EACH |
| | 150 SQUARE FEET (0.67 M 2 FOR EACH 100 M 2 ) OF UNDER |
| | -FLOOR SPACE AREA. ONE SUCH VENTILATING OPENING SHALL |
| | BE WITHIN 3 FEET (914 MM) OF EACH CORNER OF SAID |
| | BUILDING. |
| | UNDER FLOOR |
| | |
| | 3) AT THE ADDITION, SHOW COMPLIANCE WITH R408.3 ACCESS |
| | SHALL BE PROVIDED TO ALL UNDER -FLOOR SPACES. ACCESS |
| | OPENINGS THROUGH THE FLOOR SHALL BE A MINIMUM OF 18 |
| | INCHES BY 24 INCHES (457 MM BY 610 MM). OPENINGS |
| | THROUGH A PERIMETER WALL SHALL BE 16 INCHES BY 24 |
| | INCHES (407 MM BY 610 MM). WHEN ANY PORTION OF THE |
| | THROUGH WALL ACCESS IS BELOW GRADE, AN AREAWAY OF NOT |
| | LESS THAN 16 INCHES BY 24 INCHES (407 MM BY 610 MM) |
| | SHALL BE PROVIDED. THE BOTTOM OF THE AREAWAY SHALL BE |
| | BELOW THE THRESHOLD OF THE ACCESS OPENING. THROUGH WALL |
| | ACCESS OPENINGS SHALL NOT BE LOCATED UNDER A DOOR TO |
| | THE RESIDENCE. SEE M1305.1.4 FOR ACCESS REQUIREMENTS |
| | WHERE MECHANICAL EQUIPMENT IS LOCATED UNDER FLOORS. |
| | |
| | 4) SUBMIT ENERGY CALCULATION FORMS SIGNED BY THE |
| | OWNER/AGENT AS REQUIRED BY FBC 13-600 FOR THE BATH ROOM |
| | ADDITION. |
| | |
| | 5)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 6) SPECIFY THE ATTACHMENT OF THE NEW FOOTER AND WALLS |
| | TO THE EXISTING STRUCTURE AT THE BATH ROOM ADDITION. |
| | FBC 106.1.2* CITY AMENDMENTS |
| | |
| | 7) SPECIFY TERMITE TREATMENT ON THE PLANS AS REQUIRED |
| | BY SECTION R320. |
| | |
| | 8) THE MINIMUM INSULATION FOR A RAISED FLOOR SYSTEM IS |
| | R-11 PER FBC 13-600. SPECIFY THE FLOOR INSULATION ON |
| | THE PLANS. |
| | |
| | 9) THE WALL SECTION ON D-1 SPECIFIES THE ROOF SHEATHING |
| | FASTENERS AS 8D COMMONS. SECTION R803.2.3.1 OF 2006 |
| | REVISIONS TO 2004 FBC RESIDENTIAL CODE REQUIRES 8D RING |
| | SHANK NAILS. |
| | |
| | 10)DESIGN DATA NOTE H ON SHEET D-1 FOR THE ONE STORY |
| | AND A-1 FOR THE SITE WALL INCORRECTLY SPECIFIES THE |
| | SBCCI. PLEASE REVISE TO REFERENCE THE FBC. |
| | |
| | 11) SHEET 5 OF 5 APPEARS TO BE MISSING. PLEASE SUBMIT |
| | MISSING SHEET. |
| | |
| | 12) PLEASE CLARIFY WHAT IS MEANT BY EXP. B AND EXP. C |
| | AS SPECIFIED ON THE FLOOR PLAN ON SHEET A-1. |
| | |
| | 13) SPECIFY THE WINDOW SIZE AND TYPE FOR THE EXISTING |
| | BATHROOM ON THE FLOOR PLAN ON A-1. FBC 106.1* CITY |
| | AMENDMENTS |
| | |
| | 14) SUBMIT (2) TWO COPIES OF THE PRODUCT APPROVALS FOR |
| | THE ROOF COVERING, SINGLE HUNG WINDOWS AND OUTSWING |
| | DOORS. SEE DCA RULE 9B-72. |
| | |
| | 15) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE |
| | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH ONE |
| | OF THE COMMENTS HAS BEEN ADDRESSED. |
| | |