Plan Review Details - Permit 08040166
Plan Review Stops For Permit 08040166
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2008-05-20 Cont ID  
Sent By lursu Date 2008-05-20 Time 16:31 Rev Time 0.00
Received By lursu Date 2008-05-19 Time 09:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-06-06 Cont ID  
Sent By mjacobs Date 2008-06-06 Time 08:10 Rev Time 0.00
Received By mjacobs Date 2008-06-06 Time 08:03 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-05-16 Cont ID  
Sent By mjacobs Date 2008-05-16 Time 09:59 Rev Time 0.00
Received By mjacobs Date 2008-05-15 Time 14:43 Sent To PC
Notes
2008-05-16 09:59:08 
 THE STRUCTURAL PORTION OF THE PLANS ARE OK, HOWEVER THE
 ADDRESS ON THE APPLICATION AND THE PLANS DIFFER FROM
 EACH OTHER. FOR INSPECTION PURPOSES THE ADDRESS OF THE
 BUILDING NEEDS CLARIFICATION TO AVOID DELAYS LOCATING
 THE JOBSITE FOR THE INSPECTORS. YOU MAY CONTACT LILY AT
 822-1239 TO RECTIFY THE ADDRESS SITUATION. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED.
 FBC 106.1.1. SEE INFORMATION FROM THE PROPERTY
 APPRAISER WEBSITE IN THE PACKAGE PERTAINING TO THE
 ADDRESS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2008-04-12 Cont ID  
Sent By mjacobs Date 2008-04-12 Time 13:44 Rev Time 0.00
Received By mjacobs Date 2008-04-12 Time 13:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2008-04-10 Cont ID  
Sent By dpalmer Date 2008-04-10 Time 10:55 Rev Time 0.00
Received By dpalmer Date 2008-04-10 Time 10:55 Sent To  
Notes
2008-04-10 10:59:58ADDRESS ON ELECTRICAL PLANS NOT CORRECT REDLINED
 CONGRESS AVE ON TITLE BLOCKS.
 ADDRESSIS NOT 45TH ST.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2008-06-16 Cont ID  
Sent By mawillia Date 2008-06-16 Time 15:40 Rev Time 0.00
Received By mawillia Date 2008-06-16 Time 15:21 Sent To  
Notes
2008-06-16 15:40:00*****APPROVED*****
  
  
 PLAN SHEETS A.1, A.2, AND E.2 WERE STAMPED, INITIALED,
 AND DATED.LS.1 PREVIOUSLY FIRE-STAMPED ON 4/18/08 BY
 CAPT. MRW

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2008-04-18 Cont ID  
Sent By mwennerg Date 2008-04-18 Time 12:46 Rev Time 0.00
Received By mwennerg Date 2008-04-18 Time 12:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-06-10 Cont ID  
Sent By adarroug Date 2008-06-10 Time 10:10 Rev Time 0.00
Received By adarroug Date 2008-06-10 Time 10:10 Sent To  
Notes
2008-06-10 10:14:32TO "BOB"#3

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-05-29 Cont ID  
Sent By adarroug Date 2008-05-29 Time 14:21 Rev Time 0.00
Received By adarroug Date 2008-05-29 Time 14:21 Sent To  
Notes
2008-05-29 14:21:15TO "BOB"#2

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-05-05 Cont ID  
Sent By adarroug Date 2008-05-05 Time 14:45 Rev Time 0.00
Received By adarroug Date 2008-05-05 Time 14:45 Sent To  
Notes
2008-05-05 14:47:06TO "BOB"#15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-18 Cont ID  
Sent By mwennerg Date 2008-04-18 Time 12:50 Rev Time 0.00
Received By mwennerg Date 2008-04-07 Time 16:53 Sent To  
Notes
2008-04-07 16:53:52TO "BOB"#13

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2008-04-10 Cont ID  
Sent By tgordon Date 2008-04-10 Time 11:09 Rev Time 0.25
Received By tgordon Date 2008-04-10 Time 11:09 Sent To  
Notes
2008-04-10 11:10:15NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-06-19 Cont ID  
Sent By mperson Date 2008-06-19 Time 08:35 Rev Time 0.00
Received By mperson Date 2008-06-19 Time 08:35 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-06-03 Cont ID  
Sent By mperson Date 2008-06-03 Time 13:12 Rev Time 0.00
Received By mperson Date 2008-06-03 Time 13:12 Sent To  
Notes
2008-06-03 13:29:48PLUMBING PLAN REVIEW:
 DENIED 3RD TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 1. RESUBMITTED SHEETS P.1 AND P.2, DO NOT HAVE THE
 REQUIRED ARCHITECTS SEAL. PLEASE HAVE THE DESIGN
 PROFESSIONAL SEAL SHEETS P.1 AND P.2. PER FLORIDA
 STATUTES 481.221(2).
  
 2. REMOVE NONCOMPLIANT P.1 AND P.2 SHEETS FROM
 SUBMITTED PERMIT SETS OF PLANS AND PLACE ONLY COMPLIANT
 SHEETS P.1 AND P.2 IN RESUBMITEED SETS. PER (W.P.B. AS
 AMENDED) SECTION 106.1.3 QUALITY OF BUILDING PLANS. THE
 BUILDING OFFICIAL MAY ESTABLISH THROUGH DEPARTMENTAL
 POLICY, STANDARDS FOR PLANS AND SPECIFICATIONS, IN
 ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION
 PROGRAM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM
 SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED
 TO RECORDS MANAGEMENT.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-05-09 Cont ID  
Sent By mperson Date 2008-05-09 Time 11:55 Rev Time 0.00
Received By mperson Date 2008-05-09 Time 11:55 Sent To  
Notes
2008-05-09 13:29:25PLUMBING PLAN REVIEW:
 DENIED 2ND TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 THE PREVIOUS REVIEW COMMENTS AS WELL AS THE DESIGNER'S
 RESPONSE FOR PURPOSE OF CONTINUITY.
  
 1. PLEASE INDICATE THE CORRECT ADDRESS IN THE TITLE
 BLOCK ON ALL SHEETS. PER (W.P.B.) SECTION 106.1.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
 **RESPONSE NOTED, HOWEVER PLEASE REFERENCE ATTACHED
 PROPERTY APPRAISER INFORMATION WITH THE PERMIT
 APPLICATION PARCEL NUMBER THAT STATES THE ADDRESS AS
 5101 CONGRESS AVE. PLEASE INDICATE THE CORRECT ADDRESS
 ON ALL SHEETS.
  
 2. "OK" COMMENT ADDRESSED.
  
 3. SHEET P.1 WATER HEATER PIPING DIAGRAM AND EWH PAN
 DRAIN IN BATHROOM #113: THE WATER HEATER PAN DRAIN STUB
 1" BELOW CEILING SURFACE OVER THE LAVATORY IN BATHROOM
 #113 IS UNACCEPTABLE FOR A TERMINATION OVER A SUITABLE
 LOCATION. THE ONLY FIXTURE THAT IS ACCEPTABLE FOR THIS
 IS A MOP SINK.
 504.7.2 PAN DRAIN TERMINATION.
 THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER
 A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR FLOOR
 DRAIN OR EXTEND TO THE EXTERIOR OF THE BUILDING AND
 TERMINATE NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE
 THAN 24 INCHES (610 MM) ABOVE THE ADJACENT GROUND
 SURFACE.
 **RESPONSE NOTED HOWEVER THE RESUBMITTED SHEETS P.1
 AND P.2 ARE NOW INDICATING THE PAN DRAIN AS BEING ABOVE
 THE CEILING DRAINING INTO AN 1-1/2 INCH TRAP. THIS IS
 NOT A SUITABLY LOCATED INDIRECT WASTE RECEPTOR. A
 SUITABLY LOCATED WASTE RECEPTOR IS ONE LOCATED OUT IN
 THE OPEN SO THE HEATER PAN WILL BE OBSERVED DRAINING
 AND THAT THERE IS A PROPBLEM WITH THE WATER HEATER, NOT
 IN A CLOSED DROP CEILING AREA. ALSO A WASTE RECEPTOR OR
 FLOOR DRAIN WITH A TRAP WILL NEED A TRAP SEAL PRIMER
 VALVE, PER FBC-2004 PLUMBING SECTION 1002.4 TRAP SEALS.
 WHERE A TRAP SEAL IS SUBJECT TO LOSS BY EVAPORATION, A
 TRAP SEAL PRIMER VALVE SHALL BE INSTALLED. A TRAP SEAL
 PRIMER VALVE SHALL CONFORM TO ASSE 1018 OR ASSE 1044.
  
 4. "OK" COMMENT ADDRESSED.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-04-15 Cont ID  
Sent By mperson Date 2008-04-15 Time 11:51 Rev Time 0.00
Received By mperson Date 2008-04-15 Time 11:51 Sent To  
Notes
2008-04-15 11:59:56PLUMBING PLAN REVIEW:
 DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. PLEASE INDICATE THE CORRECT ADDRESS IN THE TITLE
 BLOCK ON ALL SHEETS. PER (W.P.B.) SECTION 106.1.1
 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. SHEET A.0 CLEARLY INDICATE THE FOLLOWING
 REQUIREMENTS FOR THE SINK DEMO ON THE RESUBMITTAL.PER
 FBC-2004 PLUMBING, SECTION 704.5
 DEAD ENDS: IN THE INSTALLATION OR
 REMOVAL OF ANY PART OF A DRAINAGE
 SYSTEM, DEAD ENDS SHALL BE PROHIBITED.
 A PLUMBING PERMIT REQUIRED AND
 INSPECTION REQUIRED OF DEMO WORK PRIOR
 TO COVERING DEMO WORK WITH FINNISH
 WALLS, CIELINGS, OR POURED CONCRETE
 SLABS.
  
 3. SHEET P.1 WATER HEATER PIPING DIAGRAM AND EWH PAN
 DRAIN IN BATHROOM #113: THE WATER HEATER PAN DRAIN STUB
 1" BELOW CEILING SURFACE OVER THE LAVATORY IN BATHROOM
 #113 IS UNACCEPTABLE FOR A TERMINATION OVER A SUITABLE
 LOCATION. THE ONLY FIXTURE THAT IS ACCEPTABLE FOR THIS
 IS A MOP SINK.
 504.7.2 PAN DRAIN TERMINATION.
 THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER
 A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR FLOOR
 DRAIN OR EXTEND TO THE EXTERIOR OF THE BUILDING AND
 TERMINATE NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE
 THAN 24 INCHES (610 MM) ABOVE THE ADJACENT GROUND
 SURFACE.
  
 4. SHEET P.1 WATER HEATER PIPING DIAGRAM: THERMAL
 EXPANSION CONTROL FOR THE WATER HEATER IS REQUIRED.
 607.3.2 BACKFLOW PREVENTION DEVICE OR CHECK VALVE.
 WHERE A BACKFLOW PREVENTION DEVICE, CHECK VALVE OR
 OTHER DEVICE IS INSTALLED ON A WATER SUPPLY SYSTEM
 UTILIZING STORAGE WATER HEATING EQUIPMENT SUCH THAT
 THERMAL EXPANSION CAUSES AN INCREASE IN PRESSURE, A
 DEVICE FOR CONTROLLING PRESSURE SHALL BE INSTALLED.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: THERE IS ONLY ONE CORRECTED DRAWING
 IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS
 EXAMINER FOR REFERENCE FOR THE
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2008-04-08 Cont ID  
Sent By choops Date 2008-04-08 Time 08:39 Rev Time 0.00
Received By choops Date 2008-04-08 Time 08:39 Sent To  
Notes
2008-04-08 08:40:10*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.