| Plan Review Stops For Permit 08040166 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-05-20 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-05-19 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-06 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-06 |
Time |
08:03 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-16 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-15 |
Time |
14:43 |
Sent To |
PC |
|
| Notes |
| 2008-05-16 09:59:08 | | | | THE STRUCTURAL PORTION OF THE PLANS ARE OK, HOWEVER THE | | | ADDRESS ON THE APPLICATION AND THE PLANS DIFFER FROM | | | EACH OTHER. FOR INSPECTION PURPOSES THE ADDRESS OF THE | | | BUILDING NEEDS CLARIFICATION TO AVOID DELAYS LOCATING | | | THE JOBSITE FOR THE INSPECTORS. YOU MAY CONTACT LILY AT | | | 822-1239 TO RECTIFY THE ADDRESS SITUATION. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED. | | | FBC 106.1.1. SEE INFORMATION FROM THE PROPERTY | | | APPRAISER WEBSITE IN THE PACKAGE PERTAINING TO THE | | | ADDRESS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2008-04-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-04-12 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-04-12 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-10 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-10 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2008-04-10 10:59:58 | ADDRESS ON ELECTRICAL PLANS NOT CORRECT REDLINED | | | CONGRESS AVE ON TITLE BLOCKS. | | | ADDRESSIS NOT 45TH ST. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-06-16 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-06-16 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2008-06-16 15:40:00 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A.1, A.2, AND E.2 WERE STAMPED, INITIALED, | | | AND DATED.LS.1 PREVIOUSLY FIRE-STAMPED ON 4/18/08 BY | | | CAPT. MRW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-18 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-18 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-06-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-10 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-10 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2008-06-10 10:14:32 | TO "BOB"#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-29 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-29 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2008-05-29 14:21:15 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-05 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-05 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2008-05-05 14:47:06 | TO "BOB"#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-18 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-07 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2008-04-07 16:53:52 | TO "BOB"#13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-10 |
Time |
11:09 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2008-04-10 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2008-04-10 11:10:15 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-06-19 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-19 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-19 |
Time |
08:35 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-06-03 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-06-03 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2008-06-03 13:29:48 | PLUMBING PLAN REVIEW: | | | DENIED 3RD TIME: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | 1. RESUBMITTED SHEETS P.1 AND P.2, DO NOT HAVE THE | | | REQUIRED ARCHITECTS SEAL. PLEASE HAVE THE DESIGN | | | PROFESSIONAL SEAL SHEETS P.1 AND P.2. PER FLORIDA | | | STATUTES 481.221(2). | | | | | | 2. REMOVE NONCOMPLIANT P.1 AND P.2 SHEETS FROM | | | SUBMITTED PERMIT SETS OF PLANS AND PLACE ONLY COMPLIANT | | | SHEETS P.1 AND P.2 IN RESUBMITEED SETS. PER (W.P.B. AS | | | AMENDED) SECTION 106.1.3 QUALITY OF BUILDING PLANS. THE | | | BUILDING OFFICIAL MAY ESTABLISH THROUGH DEPARTMENTAL | | | POLICY, STANDARDS FOR PLANS AND SPECIFICATIONS, IN | | | ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION | | | PROGRAM. THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM | | | SIZE, SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED | | | TO RECORDS MANAGEMENT. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-05-09 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-05-09 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-09 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2008-05-09 13:29:25 | PLUMBING PLAN REVIEW: | | | DENIED 2ND TIME: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | THE PREVIOUS REVIEW COMMENTS AS WELL AS THE DESIGNER'S | | | RESPONSE FOR PURPOSE OF CONTINUITY. | | | | | | 1. PLEASE INDICATE THE CORRECT ADDRESS IN THE TITLE | | | BLOCK ON ALL SHEETS. PER (W.P.B.) SECTION 106.1.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | **RESPONSE NOTED, HOWEVER PLEASE REFERENCE ATTACHED | | | PROPERTY APPRAISER INFORMATION WITH THE PERMIT | | | APPLICATION PARCEL NUMBER THAT STATES THE ADDRESS AS | | | 5101 CONGRESS AVE. PLEASE INDICATE THE CORRECT ADDRESS | | | ON ALL SHEETS. | | | | | | 2. "OK" COMMENT ADDRESSED. | | | | | | 3. SHEET P.1 WATER HEATER PIPING DIAGRAM AND EWH PAN | | | DRAIN IN BATHROOM #113: THE WATER HEATER PAN DRAIN STUB | | | 1" BELOW CEILING SURFACE OVER THE LAVATORY IN BATHROOM | | | #113 IS UNACCEPTABLE FOR A TERMINATION OVER A SUITABLE | | | LOCATION. THE ONLY FIXTURE THAT IS ACCEPTABLE FOR THIS | | | IS A MOP SINK. | | | 504.7.2 PAN DRAIN TERMINATION. | | | THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER | | | A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR FLOOR | | | DRAIN OR EXTEND TO THE EXTERIOR OF THE BUILDING AND | | | TERMINATE NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE | | | THAN 24 INCHES (610 MM) ABOVE THE ADJACENT GROUND | | | SURFACE. | | | **RESPONSE NOTED HOWEVER THE RESUBMITTED SHEETS P.1 | | | AND P.2 ARE NOW INDICATING THE PAN DRAIN AS BEING ABOVE | | | THE CEILING DRAINING INTO AN 1-1/2 INCH TRAP. THIS IS | | | NOT A SUITABLY LOCATED INDIRECT WASTE RECEPTOR. A | | | SUITABLY LOCATED WASTE RECEPTOR IS ONE LOCATED OUT IN | | | THE OPEN SO THE HEATER PAN WILL BE OBSERVED DRAINING | | | AND THAT THERE IS A PROPBLEM WITH THE WATER HEATER, NOT | | | IN A CLOSED DROP CEILING AREA. ALSO A WASTE RECEPTOR OR | | | FLOOR DRAIN WITH A TRAP WILL NEED A TRAP SEAL PRIMER | | | VALVE, PER FBC-2004 PLUMBING SECTION 1002.4 TRAP SEALS. | | | WHERE A TRAP SEAL IS SUBJECT TO LOSS BY EVAPORATION, A | | | TRAP SEAL PRIMER VALVE SHALL BE INSTALLED. A TRAP SEAL | | | PRIMER VALVE SHALL CONFORM TO ASSE 1018 OR ASSE 1044. | | | | | | 4. "OK" COMMENT ADDRESSED. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-15 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-15 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2008-04-15 11:59:56 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. PLEASE INDICATE THE CORRECT ADDRESS IN THE TITLE | | | BLOCK ON ALL SHEETS. PER (W.P.B.) SECTION 106.1.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | | | 2. SHEET A.0 CLEARLY INDICATE THE FOLLOWING | | | REQUIREMENTS FOR THE SINK DEMO ON THE RESUBMITTAL.PER | | | FBC-2004 PLUMBING, SECTION 704.5 | | | DEAD ENDS: IN THE INSTALLATION OR | | | REMOVAL OF ANY PART OF A DRAINAGE | | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | | A PLUMBING PERMIT REQUIRED AND | | | INSPECTION REQUIRED OF DEMO WORK PRIOR | | | TO COVERING DEMO WORK WITH FINNISH | | | WALLS, CIELINGS, OR POURED CONCRETE | | | SLABS. | | | | | | 3. SHEET P.1 WATER HEATER PIPING DIAGRAM AND EWH PAN | | | DRAIN IN BATHROOM #113: THE WATER HEATER PAN DRAIN STUB | | | 1" BELOW CEILING SURFACE OVER THE LAVATORY IN BATHROOM | | | #113 IS UNACCEPTABLE FOR A TERMINATION OVER A SUITABLE | | | LOCATION. THE ONLY FIXTURE THAT IS ACCEPTABLE FOR THIS | | | IS A MOP SINK. | | | 504.7.2 PAN DRAIN TERMINATION. | | | THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER | | | A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR FLOOR | | | DRAIN OR EXTEND TO THE EXTERIOR OF THE BUILDING AND | | | TERMINATE NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE | | | THAN 24 INCHES (610 MM) ABOVE THE ADJACENT GROUND | | | SURFACE. | | | | | | 4. SHEET P.1 WATER HEATER PIPING DIAGRAM: THERMAL | | | EXPANSION CONTROL FOR THE WATER HEATER IS REQUIRED. | | | 607.3.2 BACKFLOW PREVENTION DEVICE OR CHECK VALVE. | | | WHERE A BACKFLOW PREVENTION DEVICE, CHECK VALVE OR | | | OTHER DEVICE IS INSTALLED ON A WATER SUPPLY SYSTEM | | | UTILIZING STORAGE WATER HEATING EQUIPMENT SUCH THAT | | | THERMAL EXPANSION CAUSES AN INCREASE IN PRESSURE, A | | | DEVICE FOR CONTROLLING PRESSURE SHALL BE INSTALLED. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-08 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-08 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2008-04-08 08:40:10 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|