Plan Review Details - Permit 08040136
| Plan Review Stops For Permit 08040136 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-04-22 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-04-22 |
Time |
15:33 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-04-15 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-04-15 |
Time |
15:35 |
Sent To |
PC |
|
| Notes |
| 2008-04-15 15:39:28 | | | | | | | DENIED | | | | | | 1)THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE | | | BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS | | | DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN | | | GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600 | | | FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C | | | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND | | | PRESSURES ACCORDINGLY | | | | | | 2)SHUTTER PERMIT APPLICATIONS REQUIRE 2 COPIES OF A | | | KEY PLAN (WITH EGRESS AND OPENING SIZES SHOWN), SHUTTER | | | SCHEDULE AND THE PRODUCT APPROVALS. APPROVAL DRAWINGS | | | SHALL BE MARKED FOR MOUNTING METHOD AND CONNECTION TYPE | | | AND THE SCHEDULE FILLED OUT WITH ALL PERTINENT | | | INFORMATION SPECIFIC TO THE SITE (TYPE OF CONSTRUCTION, | | | MOUNTING CONNECTION METHOD, ANCHOR TYPE & ON CENTER | | | SPACING, SHUTTER SPAN (VERTICAL OR HORIZONTAL), ETC.) | | | PLEASE SEE THE ATTACHED MEMO AND SCHEDULE. | | | | | | 3)EGRESS FROM THE BUILDING CANNOT BE THROUGH THE | | | GARAGE DOOR, KEY PLAN SHOWS PANELS ON THE EGRESS DOOR. | | | ONLY GLAZED OPENING IN WIND BORNE DEBRIS REGIONS | | | REQUIRE IMPACT RESISTANT COVERINGS IF DOOR HAS NO | | | GLAZING PANEL WOULD NOT BE NECESSARY | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-17 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-17 |
Time |
15:11 |
Sent To |
B |
|
| Notes |
| 2008-04-17 15:11:51 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2008-04-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-04 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2008-04-04 15:32:44 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-07 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-07 |
Time |
13:33 |
Sent To |
B |
|
| Notes |
| 2008-04-07 13:37:13 | ***APPROVED*** | | | | | | PROVISO: PURSUANT TO SECTION 94-305 OF THE CITY'S | | | ZONING AND LAND DEVELOPMENT REGULATIONS:AWNINGS SHALL | | | NOT PROJECT MORE THAN FOUR FEET INTO ANY SETBACK OR BE | | | SUPPORTED BY ANY MEANS OTHER THAN ATTACHMENT TO THE | | | BUILDING. | | | | | | | | | | | | | | | | | | SENT TO "B" - MISC. 2 |
|
|
|