| Plan Review Stops For Permit 08040121 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-04-25 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-04-25 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-08-12 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-08-12 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2008-08-12 11:46:14 | REVISED DRAINAGE PLANS ARE OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-31 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-07-31 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2008-07-31 08:10:22 | REVISED DRAINAGE PLAN IS DENIED BY BUILDING. | | | | | | 1) THE SHEET NUMBERING DOES NOT CORRESPOND TO THE | | | APPROVED DRAINAGE PLANS. THERE ARE 5 SHEETS. PLEASE | | | CORRECT. | | | | | | 2) TWO SHEETS 3 OF 4 WERE SUBMITTED AND SHEET 2 OF 4 | | | WITH POLLUTION INFORMATION WAS MISSING. | | | | | | 3) IT APPEARS THAT THE ONLY SHEETS THAT NEED TO BE | | | REVISED FROM THE APPROVED PLANS ARE SHEETS 3 OF 5 AND 4 | | | 0F 5. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-01 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-07-01 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2008-07-01 13:59:40 | TRUSS SUBMITTAL | | | | | | DENIED BY BUILDING | | | | | | 1) THE PROJECT NAME AND ADDRESS ON THE TRUSS DRAWING | | | COVER SHEET IS NOT CORRECT. FAC 61G15-23.002 | | | | | | 2) THE TRUSS ENGINEER'S WET SIGNATURE IS REQUIRED ON | | | THE DOCUMENTS. THE COVERSHEETS AND TRUSS LAYOUT PLANS | | | ARE NOT ORIGINAL SIGNATURES. PHOTOCOPIES AND SIGNATURE | | | STAMPS ARE NOT ACCEPTABLE. FS471 AND FAC 61G15-23.002 | | | | | | 3) THE DESIGNER OF RECORD FOR THE PROJECT IS REQUIRED | | | TO REVIEW AND APPROVE THE TRUSS LAYOUT. | | | | | | NOTE: THE TRUSS INFORMATION IS NOT REQUIRED TO BE | | | SUBMITTED FOR PLAN REVIEW. IT IS TO BE GIVEN TO THE | | | BUILDING INSPECTOR IN THE FIELD AT THE ROOF FRAMING | | | INSPECTION. THE ABOVE CORRECTIONS ARE REQUIRED TO BE | | | COMPLETED PRIOR TO THE INSPECTION. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-05-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-05-27 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-05-27 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-04-17 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-04-17 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2008-04-17 17:57:03 | 2004 FBC W/2007 REVISIONS | | | NEW GARAGE APARTMENT | | | | | | DENIED BY BUILDING | | | | | | 1)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | | BE REQUIRED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) THE ADDRESS IN THE TITLE BLOCK IS FOR THE MAIN HOUSE | | | THE ADDRESS FOR THE GARAGE APARTMENT IS 227- 10TH | | | STREET. PLEASE CORRECT. | | | | | | 4) THE TYPE OF CONSTRUCTION SPECIFIED ON SHEET A1.1 IS | | | V AND ON S3 IT IS SPECIFIED AS III-B WITH THE OCCUPANCY | | | AS R2. THE CORRECT OCCUPANCY TYPE IS R3 AND | | | CONSTRUCTION TYPE IS V-B UNSPRINKLERED. PLEASE REVISE. | | | SEE FBC 602 AND 302. | | | | | | 5) SPECIFY THE HEIGHT OF THE GUARD RAILS AT THE | | | BALCONIES ON THE PLANS. SEE FBC R312.1 | | | | | | 6) SUBMIT A DRAINAGE PLAN SHOWING COMPLIANCE WITH | | | R401.3 DRAINAGE. SURFACE DRAINAGE SHALL BE DIVERTED TO | | | A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF | | | COLLECTION SO AS TO NOT CREATE A HAZARD. LOTS SHALL BE | | | GRADED SO AS TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE AWAY FROM FOUNDATION WALLS | | | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE | | | FIRST 10 FEET (3048 MM). | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL | | | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE | | | PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. | | | | | | 7) THE PLANS REFERENCE THE 2004 FBC WITH 2006 | | | AMENDMENTS. THE CORRECT REFERENCE IS THE 2004 FBC WITH | | | 2007 AMENDMENTS. | | | | | | 8)SHOW COMPLIANCE WITH R320.7 PROTECTION AGAINST | | | DECAY AND TERMITES. | | | CONDENSATE LINES AND ROOF DOWNSPOUTS SHALL DISCHARGE AT | | | LEAST 1 FOOT (305 MM) AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS OR | | | SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON | | | ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152 MM) | | | HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON | | | A ROOF ABOVE ANOTHER ROOF. | | | | | | 9) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | | CALCULATION FORM. ONE OF THEM HAS NOT BEEN SIGNED. SEE | | | FBC 13-600.3ABC.2 | | | | | | 10) SUBMIT 2 COPIES OF THE PRODUCT APPROVALS FOR THE | | | STRUCTURAL WINDOW MULLIONS AS REQUIRED BY DCA RULE | | | 9B-72. NOTE: THEY ARE REQUIRED TO APPROVED IN WRITING | | | BY THE DESIGNER OF RECORD. FBC 106.3.3* CITY | | | AMENDMENTS | | | | | | 11) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR | | | FLAT ROOF ZONES 1, 2 AND 3 FOR EXPOSURE CATEGORY C AND | | | A 20' MEAN ROOF HEIGHT ON THE STRUCTURAL PLANS.SEE | | | FBC TABLE R301.2(2) AND TABLE R 301.2(3). NOTE: THE | | | UPLIFT FOR ROOF ZONE 3 (CORNERS) EXCEEDS THE MAXIMUM | | | DESIGN PRESSURE OF -98.3 PSF FOR THE JOHNS MANVILLE BUR | | | SYSTEM. | | | | | | 12) SPECIFY FIREBLOCKING AS REQUIRED BY FBC R602.1.2. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-11-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-11-06 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-11-06 |
Time |
14:43 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-09 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-09 |
Time |
07:50 |
Sent To |
M |
|
| Notes |
| 2008-04-09 08:51:23 | | | | | | | | | | REDLINED BATH CIRCUIT 210.11(C)(3) ON PANEL SCHEDULE | | | AND SMOKE ALARM R313.1.1 IN THE GARAGE./WRT |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-05-22 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-22 |
Time |
09:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-15 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-15 |
Time |
09:29 |
Sent To |
B |
|
| Notes |
| 2008-04-15 10:01:00 | GAS PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS PLAN REVIEW ON SHEET A7.1 GAS PIPING ISOMETRIC TO | | | MEET CODE COMPLIANCE. | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | *NOTE: NOT ALL CUT SECTIONS OF PIPE ARE INDICATING | | | CORRESPONDING LENGTHS. PLEASE REFERENCE THE RED CIRCLED | | | YELLOW HIGH LIGHTED CUT SECTIONS THAT REQUIRE | | | CORRESPONDING LENGTHS. PER FBC FUEL GAS SECTION 401.1 | | | SCOPE. | | | | | | 2. CLEARLY INDICATE THE TYPE OF GAS, (LP OR NATURAL) | | | BEING USED. PER FBC FUEL GAS SECTION 401.1 SCOPE. | | | | | | 3. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | *NOTE: BTU LOAD 50,000 FOR THE TANKLESS WATER HEATER | | | SEEMS LOW PLEASE CLARIFY. PER (W.P.B.) SECTION 106.1.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS, SECTION 106.1.2 | | | ADDITIONAL DATA AND FBC FUEL GAS SECTION 401.1 SCOPE. | | | | | | 4. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | *NOTE: THIS INCLUDES THE EXISTING MAIN HOUSE GAS | | | SYSTEMS LONGEST LENGTH AS WELL AS THE PROPOSED GUEST | | | HOUSE WORK. ALSO IF THE GAS SYSTEM IS NATURAL GAS | | | PLEASE CORRECT THE INDICATED FUEL GAS TABLE TO BE | | | 402.4(2). | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR THE | | | TANKLESS WATER HEATER AND DRYER PER FBC-2004 FUEL GAS | | | CODE SECTION 304. | | | | | | 6. CLEARLY INDICATE THE DELIVERY PRESSURE (PSI OR WC) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. NATURAL GAS | | | SPECIFY .5 PSI OR 2 PSI. UNDILUTED PROPANE (LP) 11 INCH | | | WC, 2 PSI OR 10 PSI. | | | | | | 7. SUBMIT MANUFACTURE SHEETS FOR THE TANKLESS WATER | | | HEATER TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | | NFPA 58, AND THE FBC-2004 FUEL GAS CODE SEC 402.2. | | | *NOTE: THE MANUFACTURER'S SPECIFICATION SHEET AT A | | | MINIMUM SHALL CLEARLY INDICATE THE MAKE, MODEL NUMBER, | | | BTU LOAD CAPACITY, AND A LISTING FROM A NATIONALLY | | | RECOGNIZED TESTING LABORATORY (THIRD PARTY LISTING). | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-31 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-31 |
Time |
16:49 |
Sent To |
E |
|
| Notes |
| 2008-10-31 16:50:13 | TO "BTROBUAG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-03 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-03 |
Time |
10:49 |
Sent To |
M |
|
| Notes |
| 2008-09-03 10:49:40 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-27 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-27 |
Time |
09:09 |
Sent To |
M |
|
| Notes |
| 2008-08-27 09:10:11 | TO "MECH" TOM G. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-04 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-04 |
Time |
10:58 |
Sent To |
B |
|
| Notes |
| 2008-08-04 10:59:06 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-29 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-29 |
Time |
13:49 |
Sent To |
B |
|
| Notes |
| 2008-07-29 13:49:27 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-30 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-30 |
Time |
15:59 |
Sent To |
B |
|
| Notes |
| 2008-06-30 15:59:31 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-14 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-14 |
Time |
16:40 |
Sent To |
Z |
|
| Notes |
| 2008-05-14 16:41:06 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-04-17 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-04-07 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2008-04-07 11:20:20 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-09-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-04 |
Time |
14:59 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-09-04 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2008-09-04 15:01:05 | REVISION TO MECH. PLAN AND E-CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-27 |
Time |
13:57 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-08-27 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2008-08-27 14:19:22 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLAN | | | *** DENIED *** | | | | | | 1) MECHANICAL PLAN ON FILE WAS SIGNED AND SEALED BY AN | | | ARCHITECT (DAVID LAWRENCE) AND ONLY HE MAY MAKE | | | REVISIONS. | | | | | | 2) REVISED MECHANICAL PLAN EQUIPMENT SCHEDULE IS | | | SHOWING A 13 SEER SYSTEM, ENERGY CALCULATIONS ON FILE | | | ARE CALLING FOR A 14 SEER SYSTEM THAT'S A HEAT PUMP. | | | PLEASE CORRECT PLAN OR REVISE ENERGY CAL'S, PER 2004 | | | FBC 13-103.1.2. | | | | | | 3) A/C SYSTEM MODEL NUMBER A.H.U. 19HX5 WITH C.U. | | | 2TTR3018 (FIRST COMPANY AND TRANE) LISTED ON THE A/C | | | EQUIPMENT SCHEDULE COULD NOT BE FOUND ON THE ARI | | | DIRECTORY WEB-SITE, PLEASE CORRECT OR SUBMIT AN ARI | | | CERTIFICATE OR A MANUFACTURER'S DATA SHEET, PER 2004 | | | FBC 13-407.1.ABC.3.1.1 OR 13-607.1.ABC.3.1.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-21 |
Time |
15:32 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-05-21 |
Time |
15:32 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-10 |
Time |
07:59 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2008-04-10 |
Time |
07:59 |
Sent To |
P |
|
| Notes |
| 2008-04-10 08:24:17 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ONE COPY OF THE ENERGY CALCULATIONS HAVE NOT BEEN | | | SIGNED BY THE OWNER/AGENT, PLEASE CORRECT PER 2004 FBC | | | 13-103.3. | | | | | | 2) GAS WATER HEATER AND GAS CLOTHES DRYER APPEAR TO BE | | | IN A CONFINED SPACE. PLEASE ADD COMBUSTION AND MAKE-UP | | | AIR CALCULATIONS TO MECHANICAL PLAN AND IF NEEDED | | | PROVIDE COMBUSTION AND MAKE-UP AIR TO SPACE, PER 2004 | | | FBC/R G2407.1, G207.4, AND G2407.5.1. PLEASE ALSO CHECK | | | THE BTU'S FOR THE GAS TANKLESS WATER HEATER AS MOST | | | UNITS OPERATE AT 118,00 BTU'S OR MORE. | | | | | | 3) PLEASE SUBMIT DETAILED MANUFACTURER'S | | | SPECIFICATION'S FOR THE GAS TANKLESS WATER HEATER, PER | | | 2004 WPB AMEND. 106.1.2. | | | | | | 4)A/C SYSTEM LISTED ON A/C EQUIPMENT SCHEDULE COULD | | | NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE, PLEASE | | | CORRECT OR SUBMIT AN ARI CERTIFICATE, SEE 2004 FBC | | | 13-407.1.ABC.3.1.1 OR 13-607.1.ABC.3.1.1. | | | | | | 5) PLEASE SUBMIT DETAILED MANUFACTURER'S | | | SPECIFICATION'S FOR THE A/C SYSTEM SHOWING A CARRIER | | | CONDENSER AND FIRST COMPANY AIR HANDLER HAVE BEEN | | | DESIGNED AND TESTED TOGETHER TO RATE A 14 SEER, PER | | | 13-607.1.ABC.3.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-05-22 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-05-22 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-22 |
Time |
09:33 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-15 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-15 |
Time |
09:04 |
Sent To |
G |
|
| Notes |
| 2008-04-15 09:28:50 | PLUMBING PLAN REVIEW: | | | DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEETS A4.1 AND A5.1 THE SCUPPERS WILL REQUIRE A | | | DOWNSPOUT PER FBC BUILDING SECTION | | | 1503.6 PROTECTION AGAINST DECAY AND TERMITES. | | | CONDENSATE LINES AND ROOF DOWNSPOUTS SHALL DISCHARGE AT | | | LEAST 1 FOOT (305 MM) AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR | | | SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON | | | ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152 MM) | | | HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON | | | A ROOF ABOVE ANOTHER ROOF. | | | | | | 2. SHEET A7.1 SANITARY PLUMBING RISER PLEASE CORRECT | | | THE FOLLOWING. | | | | | | A} CLEARLY INDICATE A TW0-WAY CLEANOUT BEING USED AT | | | THE JUNCTION OF THE BUILBING DRAIN AND BUILDING SEWER. | | | PER FBC PLUMBING SECTION 708.3.5 BUILDING DRAIN AND | | | BUILDING SEWER JUNCTION. | | | | | | B} THE BRANCH DRAIN AND STACK FOR THE WASHING MACHINE | | | SHALL BE A MINIMUM OF 3 INCH. PER FBC PLUMBING SECTION | | | 406.3 WASTE CONNECTION. | | | | | | C} THE CLEANOUT FOR THE WASHING MACHINE SHALL BE 3 | | | INCH. PER FBC PLUMBING SECTION 708.7 MINIMUM SIZE. | | | | | | D} THE CLEANOUT FOR THE WASHING MACHINE SHALL BE | | | LOCATED AT 4 FEET ABOVE FINNISH FLOOR. PER FBC PLUMBING | | | SECTION 708.9 ACCESS. | | | | | | E} IF IT IS THE INTENT TO INSTALL A CLEANOUT FOR THE | | | 2ND FLOOR LAVATORY IT SHALL BE 2 INCH. PER FBC PLUMBING | | | SECTION 708.7 MINIMUM SIZE. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION | | | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: THERE IS ONLY ONE CORRECTED DRAWING | | | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS | | | EXAMINER FOR REFERENCE FOR THE | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-05-19 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-05-19 |
Time |
13:34 |
Sent To |
M |
|
| Notes |
| 2008-05-19 13:35:18 | ZONING REVIEW: PASSED | | | | | | ** IN FUTURE, PLEASE ATTACH COPY OF SURVEY TO DRAWING | | | SETS | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-04-08 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-04-08 |
Time |
10:55 |
Sent To |
E |
|
| Notes |
| 2008-04-08 10:59:10 | ZONING REVIEW: FAILED | | | | | | 1) PERMIT DWGS UNCLEAR. THEY INDICATE NEW CONSTRUCTION. | | | CITY HAS REVIEWED IN THE PAST RENOVATIONS FOR THIS | | | BUILDING. IS THIS TRULY ALL-NEW CONSTRUCTION IN LIEU OF | | | REHAB? | | | | | | 2) IF NEW CONSTRUCTION, DEMO PLANS SHOULD BE PROVIDED | | | THAT CLEAR INDICATE THE STRUCTURE WILL BE TAKEN DOWN. | | | | | | 3) SURVEY SHOULD BE PROVIDED INDICATED BUILDINGS ON | | | PROPERTY. | | | | | | 4) IF NEW CONSTRUCTION, PLEASE PROVIDE SQUARE FOOTAGE | | | FOR GARAGE AREA AND FOR APARTMENT SEPARATELY. | | | | | | MATT FLIS - 822-1445 |
|
|