Plan Review Details - Permit 08040117
Plan Review Stops For Permit 08040117
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-04-08 Cont ID  
Sent By rmcdouga Date 2008-04-08 Time 16:35 Rev Time 0.00
Received By rmcdouga Date 2008-04-08 Time 12:48 Sent To E
Notes
2008-04-08 13:51:352004 FBC W/2007 REVISIONS
 LEVEL 2 ALTERATION
  
 DENIED BY BUILDING
  
 1) A NOTICE OF COMMENCEMENT WILL BE REQUIRED.
  
 2) THE VALUE OF THE WORK IS TOO LOW. THE VALUE INCLUDES
 COST OF MATERIALS AS WELL AS LABOR AS WOULD BE CHARGED
 BY A CONTRACTOR. THE VALUE OF THE WORK HAS BEEN
 ADJUSTED TO $ 5595.00 BASED ON MARSHALL AND SWIFT
 ESTIMATING GUIDE. ADDITIONAL FEES OF $ 52.02 ARE DUE.
  
 3) SPECIFY THE TYPE OF WINDOWS AT EACH LOCATION.
 PRODUCT APPROVALS WERE SUBMITTED FOR SINGLE HUNG AND
 FIXED WINDOWS. FBC 106.1.1* CITY AMENDMENTS
  
 4) INDICATE THE LOCATIONS OF THE BEDROOMS ON THE FLOOR
 PLAN AND SHOW THAT THE EGRESS WINDOWS IN THOSE ROOMS
 HAVE NOT BEEN MADE ANY LESS SAFE BY REDUCING THE CLEAR
 OPENING SIZE. 2004 FBC EXISTING BUILDING SECTION
 501.2.
  
  
 5)OPENING #6 FOR THE NEW SLIDING GLASS DOOR IS
 SPECIFIED AS BEING WIDENED MORE THAN DOUBLE THE
 EXISTING OPENING SIZE. THIS DOES NOT CONCUR WITH THE
 PROCEDURES, WHICH SPECIFIES REMOVING THE BLOCK BELOW
 THE SILL. SUBMIT DRAWINGS THAT PROVIDE STRUCTURAL
 DETAILS OF THE NEW OPENING. FBC 106.1.1* CITY
 AMENDMENTS
  
 6) BASED ON THE DIMENSIONS SUBMITTED THE OPENING HEIGHT
 FOR THE DOUBLE DOOR WILL NEED TO BE BUILT DOWN TO
 ACCOMMODATE THE DOORS. PROVIDE STRUCTURAL DETAILS. FBC
 106.1.1* CITY AMENDMENTS
  
 7) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL
 MULLIONS. DCA RULE 9B-72.
  
 8) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 PGT SLIDING GLASS DOOR ARE EXPIRED. SUBMIT CURRENT
 PRODUCT APPROVALS. DCA RULE 9B-72.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-04-10 Cont ID  
Sent By btrobaug Date 2008-04-10 Time 09:42 Rev Time 0.00
Received By btrobaug Date 2008-04-10 Time 09:34 Sent To I
Notes
2008-04-10 09:42:31 
  
 NONCOMPLIANT
  
 AN ELECTRICAL PERMIT IS REQUIRED PER 105.1 FBC AS
 AMENDED.
  
 PER 210.70(2)(B) FOR DWELLING UNITS, ATTACHED GARAGES,
 AND DETACHED GARAGES WITH ELECTRIC POWER, AT LEAST ONE
 WALL SWITCH?CONTROLLED LIGHTING OUTLET SHALL BE
 INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR SIDE
 OF OUTDOOR ENTRANCES OR EXITS WITH GRADE LEVEL ACCESS.
 A VEHICLE DOOR IN A GARAGE SHALL NOT BE CONSIDERED AS
 AN OUTDOOR ENTRANCE OR EXIT. LOCATE SAME ON THE PLANS
 WHERE DOORS ARE BEING ADDED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-10 Cont ID  
Sent By btrobaug Date 2008-04-10 Time 09:44 Rev Time 0.00
Received By btrobaug Date 2008-04-10 Time 09:44 Sent To PC
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved