Plan Review Details - Permit 08040076
Plan Review Stops For Permit 08040076
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-05-16 Cont ID  
Sent By rmcdouga Date 2008-05-16 Time 14:06 Rev Time 0.00
Received By rmcdouga Date 2008-05-16 Time 14:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-04-15 Cont ID  
Sent By rmcdouga Date 2008-04-15 Time 11:37 Rev Time 0.00
Received By rmcdouga Date 2008-04-15 Time 11:37 Sent To ENG
Notes
2008-04-15 11:38:432004 FBC W/2007 REVISIONS
 ADDITION TO GARAGE
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL
 BE REQUIRED.
  
 2) PROVIDE DETAILS FOR THE ATTACHMENT OF THE BOND BEAM
 AND FOOTING REINFORCEMENT TO THE EXISTING STRUCTURE.
 FBC 106.1.1* CITY AMENDMENTS
  
 3) SPECIFY THE LOCATION OF THE VERTICAL REINFORCEMENT
 AT THE CORNERS AND EACH SIDE OF THE DOOR OPENING. FBC
 R609.3
  
 4) SPECIFY THE APPLICABLE BUILDING CODE AND WIND DESIGN
 INFORMATION ( BASIC WIND SPEED AND EXPOSURE CATEGORY) .
 FBC R301
  
 5) A SIMPSON MTS 18 IS SPECIFIED FOR THE RAFTER TO
 EXISTING WALL CONNECTION. IF THE EXISTING WALL IS
 MASONRY, A DIFFERENT CONNECTOR SHOULD BE USED, SUCH AS,
 THE MTSM 16 OR HTSM 16. PLEASE REVIEW. FBC 106.1.1.2*
 CITY AMENDMENTS
  
 6) THE LAP LENGTH FOR THE #7 BARS SPECIFIED FOR THE
 BOND BEAM IS 59" PER FBC TABLE R606.9.2. PLEASE SPECIFY
 ON THE PLANS.
  
 7) THE ROOF SHEATHING IS REQUIRED TO BE IN ACCORDANCE
 WITH SECTION R803.2.3.1 OF 2006 REVISIONS TO 2004 FBC
 RESIDENTIAL CODE. WOOD STRUCTURAL PANEL SHEATHING SHALL
 BE FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT
 6 INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT
 INTERMEDIATE FRAMING. SPACING OF RING-SHANK FASTENERS
 SHALL BE 4 INCHES ON CENTER IN NAILING ZONE 3 FOR 130
 MPH OR GREATER DESIGN WIND SPEEDS IN ACCORDANCE WITH
 FIGURE R803.2.3.1.
  
 8) THE PRODUCT APPROVALS FOR THE DOUBLE OUTSWING DOOR
 DOORS THAT WERE SUBMITTED ARE EXPIRED, EXCEPT FOR THE
 ONE FOR THE NON-IMPACT RATED GLAZED DOORS. SUBMIT
 CURRENT PRODUCT APPROVALS FOR THE DOOR THAT WILL BE
 INSTALLED. DCA RULE 9B-72.
  
 10) THE PRODUCT APPROVALS SUBMITTED FOR THE GAF ROOF
 COVERING CONTAINS SEVERAL ASSEMBLIES AND DECK TYPES.
 SPECIFY THE APPROVED ASSEMBLY, FASTENING OPTION AND
 DESIGN PRESSURE THAT WILL BE USED. CIRCLE THE CORRECT
 ITEMS FROM THE PRODUCT APPROVAL. ENHANCED FASTENING MAY
 BE REQUIRED AT THE PERIMETER AND CORNER AREAS. SEE
 LIMITATION #7 AND SUBMIT RAS 117 CALCULATIONS FOR
 ENHANCED FASTENING AS REQUIRED BY THE PRODUCT
 APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2008-05-16 Cont ID  
Sent By dpalmer Date 2008-05-16 Time 13:08 Rev Time 0.00
Received By dpalmer Date   Time   Sent To B
Notes
2008-05-16 13:09:56SCOPE OF WORK REVISED TO DRIVEWAY PERMIT ONLY.
 NO ELECTRICLA WORK APPLIED FOR.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-04-03 Cont ID  
Sent By dpalmer Date 2008-04-03 Time 16:07 Rev Time 0.00
Received By dpalmer Date 2008-04-03 Time 16:07 Sent To B
Notes
2008-04-03 16:09:32** DENIED**
  
  
 1) NOTE: PLEASE SEE ZONING COMMENTS, STRUCTURE MAY NOT
 BE BUILT AS SHOWN ON PLANS.
  
 2) NOTE: NO ELECTRICAL SHOWN, NO ELECTRICAL APPLIED
 FOR. PLEASE VERIFY ANY ELECTRICAL SCOPE OF WORK.
  
 THIS REVIEW MAY BE CHNAGED AT LATER LATER DATE IF NO
 ELECTRICAL WILL BE IN SCOPE OF WORK.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2008-05-16 Cont ID  
Sent By rmcdouga Date 2008-05-16 Time 14:08 Rev Time 0.00
Received By rmcdouga Date 2008-05-16 Time 14:08 Sent To  
Notes
2008-05-16 14:10:50OK PER WINDEL PALMER

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2008-04-17 Cont ID  
Sent By rchokshi Date 2008-04-17 Time 09:40 Rev Time 0.00
Received By RCHOKSI Date 2008-05-16 Time 13:08 Sent To  
Notes
2008-04-17 09:40:35FAILED FOR FOLLOWING REASONS:
  
 1. PLEASE PROVIDE A DETAIL DRAWING SHOWING ALL THE
 DIMENSIONS FOR DRIVEWAY, APPROACH, SIDEWALK ETC2
 COPIES.
  
 2. YOU ARE PUTTING AN APPROACH, DRIVEWAY, SIDEWALK &
 CUTTING A CURB IN CITY'S RIGHT OF WAY. THEREFORE, YOU
 NEED CITY'S RIGHT OF WAY APPROVAL FROM WINDEL PALMER
 494-1040, 1000 45TH STREET, ENG DEPT.ONCE WE HAVE AN
 APPROVAL FROM WINDEL PALMER, WE WILL REVIEW YOUR
 DRAWINGS.
  
 3. MUST MEET CITY'S STANDARDS FOR APPROACH,
 SIDEWALK,DRIVEWAY ETC. A SHEET " TYPICAL PAVER
 STONE/CONCRETE DRIVEWAY APPROACH DETAILS" ENCLOSED FOR
 YOUR USE.
  
 RASIK CHOKSHI 805-6723

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-05-06 Cont ID  
Sent By adarroug Date 2008-05-06 Time 12:55 Rev Time 0.00
Received By adarroug Date 2008-05-06 Time 12:55 Sent To Z
Notes
2008-05-06 12:55:52TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-17 Cont ID  
Sent By rchokshi Date 2008-04-17 Time 09:41 Rev Time 0.00
Received By rchokshi Date 2008-04-17 Time 09:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2008-05-08 Cont ID  
Sent By choops Date 2008-05-08 Time 10:07 Rev Time 0.00
Received By choops Date 2008-05-08 Time 10:07 Sent To E
Notes
2008-05-08 10:07:03***APPROVED - RESUB #1 - REDUCED SCOPE OF WORK TO ONLY
 INCLUDE DRIVEWAY AND APPROACH***
  
  
  
  
 SENT TO "E" - DP

Review Stop Z ZONING
Rev No 1 Status F Date 2008-04-03 Cont ID  
Sent By choops Date 2008-04-03 Time 14:38 Rev Time 0.00
Received By choops Date 2008-04-03 Time 14:38 Sent To E
Notes
2008-04-03 14:59:00***FAILED***
  
  
 1)AS THE EXISTING ACCESSORY STRUCTURES ALREADY
 EXCEED THE MAXIMUM SQUARE FOOTAGE ALLOWANCE OF 1,000
 SQUARE FEET, NO ADDITION WHICH INCREASES THE SQUARE
 FOOTAGE OF THESE BUILDINGS SHALL BE PERMITTED.
  
 PURSUANT TO SECTION 94-304(B)(1) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS: MAXIMUM SQUARE FOOTAGE.THE
 TOTAL FLOOR AREA OF ALL ROOFED ACCESSORY BUILDINGS ON A
 PROPERTY SHALL NOT EXCEED 75 PERCENT OF THE GROSS FLOOR
 AREA OF THE PRIMARY STRUCTURE WITH A MAXIMUM FLOOR AREA
 OF 1,000 SQUARE FEET.
  
 2)PURSUANT TO SECTION 94-482 OF THE ZLDRS: REQUIRED
 OFF-STREET PARKING SPACES FOR LESS THAN FOUR
 RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE
 PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED
 PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE
 LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT
 YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN
 THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH,
 NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION
 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO
 PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE.
  
 PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE
 SURFACES LOCATED WITHIN THE FRONT YARD (FROM FRONT
 PROPERTY LINE TO THE FRONT BUILDING FACADE).
  
 3)APPROVAL FROM THE CITY'S ENGINEERING DEPARTMENT IS
 REQUIRED FOR PLANTING OF TREES WITHIN THE PARKWAY (FROM
 FRONT PROPERTY LINE TO THE STREET) 561-494-1040.SEE
 ENGINEERING REVIEW COMMENTS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "E" - SF RACK