| 2008-04-03 09:44:52 | ***FAILED*** |
| | |
| | |
| | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY |
| | (SUBMITTED PLAN WAS A SITE PLAN), SHOWING THE LOCATION |
| | OF THE PROPOSED TEMPORARY CONSTRUCTION FENCE. |
| | |
| | 2)FENCE HEIGHT SHALL BE INDICATED ON BOTH THE PERMIT |
| | APPLICATION AND THE PLANS (SURVEYS AND DETAILS). |
| | |
| | 3)AN APPROVED EASEMENT CONSENT FORM FROM THE CITY OF |
| | WEST PALM BEACH DEPARTMENT OF PUBLIC UTILITIES (1ST |
| | FLOOR CITY HALL) IS REQUIRED FOR ALL PROPOSED |
| | FENCES/WALLS. |
| | |
| | 4)PLANS SHALL INDICATE COMPLIANCE WITH SECTION |
| | 94-305(E) OF THE CITY'S ZONING AND LAND DEVELOPMENT |
| | REGULATIONS: |
| | |
| | VISIBILITY AT INTERSECTIONS.AT ANY ROAD |
| | INTERSECTIONS, VISIBILITY SHALL NOT BE OBSCURED BY THE |
| | CONSTRUCTION, PLACEMENT, OR MAINTENANCE OF A STRUCTURE |
| | WALL, SIGN, FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY |
| | SIMILAR ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT |
| | WITHIN A TRIANGLE BEGINNING AT THE POINT WHERE PROPERTY |
| | LINES MEET AT THE CORNER, THEN 20 FEET ALONG THE FRONT |
| | PROPERTY LINE, THENCE DIAGONALLY TO A POINT ALONG THE |
| | SIDE PROPERTY LINE 20 FEET FROM THE POINT OF BEGINNING, |
| | AND THENCE TO THE POINT OF BEGINNING. IN THE EVENT THE |
| | CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT |
| | SHALL BEGIN AT THE POINT THE PROPERTY LINES WOULD MEET |
| | WITHOUT ROUNDING. (SEE FIGURE X-1, ATTACHED WITH PERMIT |
| | APPLICATION PACKET). |
| | |
| | 5)SCREENING DETAILS SHALL BE SUBMITTED WITH THE |
| | TEMPORARY CONSTRUCTION FENCE PERMIT APPLICATION. WIND |
| | SCREENING SHALL BE SUBSTANTIAL ENOUGH TO AVOID RIPS OR |
| | TEARS DUE TO WIND OR SUN, AND SHALL HAVE NO LESS THAN |
| | 85 PERCENT OPACITY.SCREENING SHALL BE MAINTAINED IN |
| | GOOD CONDITION AT ALL TIMES.ANY SCREENING GRAPHICS |
| | SHALL BE APPROVED WITH A PERMIT PURSUANT TO THE |
| | PROVISIONS OF CHAPTER 94, ARTICLE 13, SIGN REGULATIONS, |
| | OF THE ZONING AND LAND DEVELOPMENT REGULATIONS OF THIS |
| | CODE. |
| | |
| | 6)SANDBAGS/STANDS ARE NOT SUFFICIENT.FENCE MUST BE |
| | SET IN GROUND.SEE FBC NOTE BELOW. |
| | |
| | |
| | NOTE:TEMPORARY CONSTRUCTION FENCES SHALL BE INSTALLED |
| | IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND |
| | OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) |
| | STANDARDS. |
| | |
| | NOTE:ALL TEMPORARY CONSTRUCTION FENCING SHALL BE |
| | MAINTAINED IN A SATISFACTORY MANNER BY THE PERMITTEE OR |
| | LANDOWNER, DURING THE ENTIRE PERIOD OF THE LAND |
| | DISTURBING CONSTRUCTION AND LAND DEVELOPMENT |
| | ACTIVITIES, TO ENSURE ADEQUATE PERFORMANCE, TO PREVENT |
| | NUISANCE CONDITIONS AND TO MAINTAIN THE PUBLIC HEALTH, |
| | SAFETY AND WELFARE. |
| | |
| | NOTE:GATES SHALL BE CHAINED AND LOCKED WITH A LOCK |
| | SUBSTANTIAL ENOUGH TO ENSURE CLOSURE AND SECURITY WHEN |
| | WORKERS ARE NOT ON THE JOB SITE. |
| | |
| | NOTE:NO TEMPORARY CONSTRUCTION FENCE MAY ENCROACH |
| | BEYOND THE SUBJECT PROPERTY LINE.NO FENCE MAY |
| | ENCROACH UPON THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING |
| | THE APPROPRIATE PUBLIC RIGHT-OF-WAY PERMIT(S). |
| | |
| | |