| Plan Review Stops For Permit 08030723 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-30 |
Time |
13:31 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-09-30 |
Time |
13:31 |
Sent To |
PC |
|
| Notes |
| 2008-09-30 13:32:34 | REV# 1 SHEET S-2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-09-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-04 |
Time |
11:32 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-09-04 |
Time |
11:32 |
Sent To |
PC |
|
| Notes |
| 2008-09-04 11:33:26 | REVISION# 2. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-12 |
Time |
11:42 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2008-08-12 |
Time |
11:42 |
Sent To |
PC |
|
| Notes |
| 2008-08-12 11:43:18 | PLANS APPEAR TO BE CODE COMPLIANT WILL NEED IMPACT FEE | | | ASSESSMENT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-07-08 |
Time |
07:53 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-07-08 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2008-07-08 07:55:05 | BUILDING, PLANS ARE CODE COMPLIANT REQUIRES IMPACT FEE | | | ASSESSMENT BEFORE ISSUANCE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-17 |
Time |
07:19 |
Rev Time |
5.50 |
| Received By |
jwitmer |
Date |
2008-04-17 |
Time |
07:19 |
Sent To |
PC |
|
| Notes |
| 2008-04-17 11:01:22 | BUILDING PLAN REVIEW | | | PERMIT: 08030723 | | | ADD: 6910 S DIXIE HWY | | | CONT: SULLIVAN BUILDERS | | | TEL: (561)586-5353 (NEYITA) | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS | | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | | | 1C)INFORMATIONAL106.1.1* W.P.B. ADMINISTRATIVE | | | CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR | | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) INFORMATIONAL FL S S 713.13NOTICE OF | | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1E)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE2007 SUPPLEMENTS. | | | | | | 2) SHEET A-1 INDICATES TWO EXIT DOORS ONE ON EITHER | | | SIDE OF THE BUILDING. BOTH EXIT DOORS INDICATE THE USE | | | OF DOOR CLOSERS,AND WOULD HAVE SELF LATCHING | | | DOORSBEING EXTERIOR EXIT DOORS. | | | THE PLANS ARE MISSING THE REQUIRED 12" SIDE CLEARENCE | | | ON THE LATCH SIDE OF THE DOOR, SEE11-4.13.6 | | | MANEUVERING CLEARENCES AT DOORS. MINIMUM MANEUVERING | | | CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN FIG. 25. THE FLOOR | | | OR GROUND AREA WITHIN THE REQUIRED CLEARANCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 3) PRODUCT APPROVALS, PLEASE NOTE THAT THE TYPE OF | | | GLAZING AND IF MULLIONS AND FRAMES REQUIRE REINFORCING, | | | PLEASE SEE SHEET A-2 & S-1 THE WESTERN EXPOSURE,THE | | | FRONT ENTRY IS DRAWN WITHOUT A TRANSOM BUT THE FRAMING | | | MEMBERS OR BEAM THAT CARRIES THESE MEMBERS WOULD BE AT | | | THE TALLEST WINDOWS. THE HORIZONTALL MULLION THAT WOULD | | | BE CARRYING THE LOAD IS OVER 13'-6" LONG PLUS THE | | | STUCCO LOADSAPPLIED TO THIS AREA. PLEASE VERIFY THE | | | FRAMING CONDITIONS IN THIS AREA.AT THIS TIME UNABLE | | | TO DO A REVIEW ON THE STOREFRONT PANEL WALL SYSTEM NOR | | | DOORS DUE TO INSUFFICIENT INFORMATION. | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED, & TABLE | | | 1609.2.1.(2). | | | | | | 4) PLEASE PROVIDE ADDITIONAL INFORMATION, SHEET A-3 | | | INDICATES THE USE OF R-19 ICYNENE, THE USE OF ICYNENE | | | TO THE UNDER SIDE OF THE ROOF SHEATHING DECK. THE PLANS | | | DO NOT INDICATE IF THE | | | END GABLE WALLS ARE A CONTINUATION OF THE CBS WALLS OR | | | IF THEY ARE WOOD STUD GABLE END WALLS? THIS INFORMATION | | | WILL HELPIN THE PLAN REVIEW. NOTE ALSO INCLUDED IS A | | | ICC LEGACY REPORT NER-420 | | | AND A INFORMAL CODE INTERPRETATION.IF THE GABLE END | | | WALLS ARE WOOD WALLS PLEASETAKE NOTE TO THE ASSEMBLY | | | 1-4 AND COMMENTS TO VERTICAL SURFACES AND | | | REQUIREMENTS. | | | ADDITIONAL INFORMATION REQUIRED, 106.1.2. | | | | | | 5)ADDITONAL INFORMATION REQUIRED, 106.1.2. SHEET A-3 | | | INDICATES THE USE OF 1/2" DRYWALL BUT THE FINISH IS NOT | | | KNOWN. PLEASE LOOK AT TABLE 2508.1 FOR GYPSUM BOARD | | | APPLICATIONS GA-216 IS REFERENCED. THE APPLICATION OF | | | WATER BASED TEXTURE MATERIALS ISA CONCERN EXSPECIALLY | | | ON A NON VENTED VEILING. PLEASE SEE TABLE 1 AND THE | | | APPENDIX A.2FOR THE CONCERNS AND REQUIREMENTS FOR | | | FRAMING SPACING. | | | | | | 6)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE.) | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-18 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-18 |
Time |
14:29 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-08-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-07 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-07 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2008-08-07 16:55:41 | | | | **DENIEDREVIEW** | | | | | | ** PLEASE SEE THERE ARE SEVERAL ITEMS REVISED ON PLANS | | | WHICH WERE NOT PART OF PREVIOUS COMMENTS NOR WAS IT | | | BROUGHT UP IN MEETING PREVIOUSLY HELD BEFORE PLANS WERE | | | RESUBMITTED. IT IS UNCLEAR WHY THESE ITEMS WERE | | | REVISED. | | | THE PREVIOUS REVIEW NOTES DID HAVE COMMENTS FOR THE | | | NEED OF REVISING LOAD CALCULATIONS WHICH WERE NOW DONE | | | HOWEVER THESE HAVE NOW CHANGED WHICH WOULD REQUIRE THE | | | EXISTING MAIN TO BE UPGRADED. | | | THE FOLLOWING ITEMS ARE NOW NOTED. | | | | | | | | | 1) NOTE:THE FOLLOWING ARE EXAMPLES: | | | PLEASE SEE THE FEEDERS SCHEDULE HAS NOW BEEN REVISED. | | | PANEL *B* IS A 200AMP MCB PANEL NOW REVISED WITH TAPPED | | | CONDUCTORS SHOWN AS 500MCM. THE 500MCM WILL NOT FIT | | | INTO A 200AMP BREAKER. | | | PLEASE SEE PANEL SCHEDULE FOR LA. THIS PANEL HAS NOW | | | BEEN REVISED TO A 200AMP MCB WHICH IS OK. | | | PLEASE SEE THE BREAKER IN PANEL *LB* WHICH IS SHOWING A | | | 3-POLE 60AMP BREAKER WITH 1/0 FEEDERS. THE 1/0 FEEDERS | | | WILL NOT FIT UNDER A LUG OF A 60AMP BREAKER. IN ANY | | | CASE PLEASE LOOK AT LOAD CALCULATIONS. THE LOAD NOW | | | SHOWN FOR PANEL *LP* IS SHOWN AT 163AMPS YET THE | | | BREAKER AS NOTED IS ONLY 60AMPS AND THE FEEDERS AS 1/0 | | | ARE ONLY RATED FOR 150AMPS. | | | PLEASE SEE THE LOAD CALCULATIONS AS THE SERVICE LOAD IS | | | NOW SHOWN AT 455AMPS ON A 400AMP MAIN. | | | PLEASE SEE THE LOAD SHOWN ON PANEL *LB* FOR PANEL *LP*. | | | THE LOAD ON SHEET E-4 FOR PANEL LP IS NOT THE SAME AS | | | LOAD ON LB. | | | ETC. | | | 220,240.4,310.16,,110.3 | | | NEITHER OF THESE TWO LOADS ARE THE SAME AS THE LOAD | | | CALCULATIONS ON SHEET E-5. | | | PLEASE CALL TO SET UP A MEETING AS SOON AS POSSIBLE TO | | | GO OVER PLANS. | | | PLACED CALLS TO ELECTRICAL CONTRACTOR, ARCHITECT AND | | | EXPEDITOR. | | | SPOKE TO CONTRACTOR AND THEY WERE NOT AWARE OF | | | CHANGES. | | | SPOKE WITH ARCHITECT AND A MEETING IS TO BE SET. | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-07-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-08 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-08 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2008-07-08 17:13:35 | ** DENIED2ND REVIEW ** | | | | | | ** PLEASE SEE THERE ARE SOME ITEMS FROM PREVIOUS REVIEW | | | WHICH ARE STILL IN NEED OF ADDRESSING. | | | ** PLEASE ALSO SEE THERE ARE SOME NEW COMMENTS WHICH | | | ARE BASED ON REVISED PLANS OR INFORMATION NOW BEING | | | SHOWN. | | | ** PLEASE ALSO SEE THERE IS A NEW COMMENT WHICH WAS NOT | | | ON PREVIOUS REVIEW EVEN AS PREVIOUS PLANS DID CONTAIN | | | ERROR. | | | | | | 1) NOTE: PLEASE SEE 13-415.2.ABC.1.1, .1.2 .1.3 AND | | | 13-415.2. PLEASE KNOW ALLOWANCES FOR ADDITIONAL | | | LIGHTING IN AREAS MAY NOT BE USED OR TAKEN INTO ACCOUNT | | | IN CALCULATIONS UNLESS SPECIFICALLY INSTALLING LIGHTING | | | ETC FOR THAT ADDITIONAL ALLOWANCE. | | | | | | FOR EXAMPLE: | | | PLEASE SEE THE HALLWAY AREAS OUTSIDE THE BATHROOMS | | | WHICH ARE TAKING AN ADDITIONAL 1W PER SQ FT FOR | | | DECORATIVE LIGHTING YET NONE OF THESE TYPES OF FIXTURES | | | ARE ON PLANS. | | | ** THIS IS ONE EXAMPLE GIVEN. THIS IS NOT THE ONLY | | | LOCATION. BASED ON THE ALLOWANCES PERMITTED IN THE CODE | | | AND THE DESIGN WATTAGE TOTAL SHOWN THE TOTAL DESIGN | | | WATTAGE IS OVER. | | | PLEASE ADJUST. | | | ** NOTED PREVIOUSLY | | | | | | 2) NOTE: PLEASE SHOW THE SHOW WINDOW CALCULATIONS PER | | | 220.43A. | | | ** AN EXAMPLE OF THIS IS CIRCUIT LA-1 WHICH SHOWS A 1.0 | | | KVA. HOW IS THIS POSSIBLE WHEN THE LINEAR FT OF WINDOW | | | IS 13FT AND THE CODE REQUIRES A LOAD OF 200VA PER FT. | | | THE LOAD FOR BRANCH CIRCUIT SIZING PER 220.14 AND | | | SIZING FOR SERVICE PER 220.43 IS NOT THE SAME. | | | PLEASE SHOW THESE FIGURES INTO REVISED LOAD | | | CALCULATIONS FOR PANELS AND SERVICE. | | | ** NOTED PREVIOUSLY | | | | | | 3) NOTE: PLEASE SEE SECTION 220.43B FOR TRACK LIGHTING | | | AND SHOW LOAD IN CALCULATIONS FOR PANELS AND SERVICE. | | | ** NOTED PREVIOUSLY. | | | | | | 4) NOTE: PLEASE SEE 700.12F FOR CIRCUITING OF EMERGENCY | | | LIGHTS. BASED ON PLANS, FLOOR LAYOUT AND DESIGN MAY NOT | | | USE EXCEPTION AND MUST CIRCUIT TO THE LOCAL LIGHTING | | | BRANCH CIRCUIT IN ANY ONE AREA AHEAD OF ANY SWITCHING | | | DEVICES INCLUDING LIGHTING CONTROL PANEL. | | | ** THIS IS A NEW COMMENT EVEN THOUGH PLANS DO CONTAIN A | | | NOTE #2 WHICH IS LABELED TO CONNECT AHEAD OF LOCAL | | | CIRCUIT. AS THE PLANS SHOW THESE EMERGENCY LIGHT | | | FIXTURES TO THEIR OWN CIRCUIT ON THE LIGHTING CONTROL | | | PANEL AND TO EACH LOCAL CIRCUIT BY NOTE, THESE NEEDS TO | | | BE ADDRESSED AND COORDINATED. | | | | | | 5) NOTE: PLEASE COORDINATE THE FEEDERS FOR LIGHTING | | | PANEL. RISER SHOWS A NOTE *D* WHICH NOTES #3 CONDUCTORS | | | YET THE PANEL SCHEDULE RISER AND PANEL SCHEDULE *LB* | | | STATES #6 FOR THE SAME FEEDERS. | | | THIS IS A NEW COMMENT AS THE PREVIOUS PLANS SHOWED THE | | | SAME. | | | PLEASE COORDINATE. 310.16, 240.4, 408.4 | | | FBC 106.1.2, 106.1.1 FOR COORDINATION AND CLARITY OF | | | PLANS. | | | ** NEW COMMENT MISSED FROM NOTES IN PREVIOUS REVIEW. | | | | | | 6) NOTE: PLEASE COMPLETE BAY NUMERICAL DESIGNATIONS ON | | | POWER PLANS FOR COORDINATION OF CIRCUITING WITH PANEL | | | SCHEDULES. | | | 408.4, 310.16, 240.4 ETC | | | FBC 106.1.1 FOR CLARITY AND COORDINATION OF RECORD | | | PLANS. | | | ** NOTED ON PREVIOUS REVIEW | | | | | | 7) NOTE: PLEASE VERIFY ANY EXTERIOR LIGHTING AT THIS | | | LOCATION. PLANS, PANELS, LOAD CALCULATIONS ETC DO NOT | | | INDICATE ANY LIGHTING. | | | SITE/SURVEY DOES INDICATE EXTERIOR LIGHTS SUCH AS LIGHT | | | POLES HOWEVER NONE INCLUDED AS NOTED. | | | PLEASE COMPLETE AND COORDINATE ALL ITEMS SUCH AS | | | LIGHTING CONTROLS PER 13-415.1.ABC.1.4, LOADS PER NEC | | | 220, PANEL SCHEDULES PER NEC 408, CIRCUITING, | | | CONDUCTORS BREAKERS ETC. | | | ** THIS IS NEW BASED ON REVISED PLANS NOWSHOWING | | | EXTERIOR LIGHTINGWHICH WAS NOT ON PREVIOUS PLANS. | | | | | | | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-04 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-03 |
Time |
19:06 |
Sent To |
|
|
| Notes |
| 2008-04-04 11:01:31 | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE BE SURE THE ELECTRICAL PLANS CONTAIN | | | THE FOLLOWING MINIMUM CODES. | | | 2004 FBC W/ 2007 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | | | | 2) NOTE: PLEASE SEE 13-415.1.ABC.1.1.1.2 AND .1.3 FOR | | | THE FOLLOWING ITEMS NEEDED. | | | PLEASE PROVIDE MAXIMUM OVER RIDE TIMES FOR DEVICES. | | | PLEASE SEE THAT WHEN OVER RIDES ARE LOCATED IN ANY | | | BUILDING/SPACE THE OCCUPANT IS REQUIRED TO SEE ALL | | | LIGHTING IN WHICH THEY ARE OVER RIDING OR MUST PROVIDE | | | FOR THE EXCEPTION IN THE CODE. THE LOCATION ON PLANS | | | DOES NOT PERMIT THE OCCUPANT TO SEE ALLLIGHTING AND | | | NO INDICATORS AS REQUIRED COULD BE FOUND ON LIGHTING | | | CONTROL RISER OR PLANS. | | | | | | 3) NOTE: PLEASE PROVIDE COMPLETE LIGHTING PERFORMANCE | | | CALCULATIONS PER FBC 13-415.2, 13-415.2.ABC.1.1, .1.2 | | | AND .1.3. | | | PLEASE SEE 13-400.3.B, 13-400.3.C, ETC. | | | AS NO LIGHTING PERFORMANCE CALCULATIONS WERE SUBMITTED | | | A REVIEW OF THESE COULD NOT BE DONE AT THIS TIME. | | | PLEASE BE SURE ALL LIGHTING ON PLANS COORDINATES WITH | | | THE CALCULATIONS TO BE PROVIDED. | | | | | | 4) NOTE: PLEASE SEE 600.5 FOR MISSING REQUIRED SIGN | | | CIRCUIT. (PLEASE BE SURE TO ADD DEDICATED MINIMUM | | | LOAD) | | | | | | 5) NOTE: PLEASE VERIFY ALL REQUIRED CONTINUOUS LOADS. | | | PANEL LB STATES CONTINUOUS LOADS WERE FIGURED AT 125%, | | | HOWEVER PANEL LA DOES NOT SHOW OR INDICATE THESE | | | REQUIRED CONTINUOUS LOADS, | | | FOR EXAMPLE; | | | LIGHTING, WATER HEATER, ETC. | | | 215.3, 230.42, 422.13 (2005 NEC) ETC. | | | PLEASE ADJUST AND SHOW WHERE LOADS ARE FIGURED IN | | | CALCULATIONS. | | | | | | 6) NOTE: PLEASE SEE 220.43 AND PROVIDE LOADS ON SHOW | | | WINDOWS AND HOW THEY WERE FIGURED INTO CALCULATIONS. | | | | | | 7) NOTE: PLEASE PROVIDE ALL ROOM AND AREA DESIGNATIONS | | | ON ELECTRICAL PLANS. | | | FBC 106.1.2 | | | | | | 8) NOTE: PLEASE CLARIFY THE SIZES OF THE PANELS AS | | | THESE ARE SHOWN AS 125AMPS WITH 42CIRCUITS ON ONE AND | | | THE OTHER AS 200AMP AND 24 CIRCUITS. | | | PLEASE SEE 110.3, 90.7 AND VERIFY LISTING OF THIS. | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2008-04-03 19:06:59 | 2008-04-03 19:06:59 | | | | | | IN ELECTRICAL FOR REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-07-23 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-07-23 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2008-07-23 13:13:46 | *****PARTIAL APPROVAL***** | | | | | | | | | PLAN SHEETS LS-1, A-1, A-2, AND A-4 WERE STAMPED, | | | INITIALED, AND DATED;HOWEVER SHEET E-2 TO BE | | | FIRE-STAMPED WHEN THE ELECTRICAL EXAMINER'S COMMENTS | | | HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-28 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-28 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2008-04-28 11:29:09 | PLANS APPEAR TO BE CODE COMPLIANT, HOWEVER WILL REMAIN | | | IN FAILED STATUS UNTIL CORRECTED AND RETURNED FOR OTHER | | | REVIEW COMMENTS. PLEASE VERIFY THAT ELECTRICAL ROOM | | | DOOR IS (2) HOUR RATED AND NOT 1 1/2 HOUR AS COMMONLY | | | FOUND IN (2) HOUR ENCLOSURES. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVNTION (561) 805-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-10-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-01 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-01 |
Time |
08:52 |
Sent To |
M |
|
| Notes |
| 2008-10-01 08:53:21 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-15 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-15 |
Time |
13:31 |
Sent To |
B |
|
| Notes |
| 2008-09-15 13:31:35 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-08-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-28 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-28 |
Time |
13:47 |
Sent To |
B |
|
| Notes |
| 2008-08-28 13:47:47 | TO "BUILD"JIM W. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-14 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-14 |
Time |
10:11 |
Sent To |
E |
|
| Notes |
| 2008-08-14 10:11:30 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-30 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-30 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2008-07-30 15:46:58 | TO "COMM" BD#53 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-19 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-19 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2008-06-19 11:41:49 | TO "COMM" BD#16 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-21 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-21 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2008-05-27 16:00:42 | TO "COMM" BD#6 | | 2008-05-21 09:45:03 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-28 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-01 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2008-04-01 11:02:07 | TO "COMM" BD#34 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-10-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-10-17 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-10-17 |
Time |
08:30 |
Sent To |
PC |
|
| Notes |
| 2008-10-17 08:30:32 | MECH REVISION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-07-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-08 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-08 |
Time |
09:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-04-24 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-04-24 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2008-04-24 16:54:52 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS AND RESUBMIT: | | | | | | 1. ELECTRICAL ROOM IS SHOWN ON PG A-1 TO BE ENCLOSED IN | | | 2-HOUR FIRE RESISTANCE RATED CONSTRUCTION. HVAC PLAN | | | SHOWS A 6 INCH ROUND DUCT PENETRATING THE 2-HOUR WALL. | | | SHOW HOW THIS DUCT PENETRATION IS TO BE PROTECTED IN | | | ACCORDANCE WITH FBCM 607.5.2 AND FBCM 607.8. | | | | | | 2. HVAC PLAN NOTES CALL FOR ADJUSTABLE FRESH AIR | | | INTAKE. MOTORIZED SHUTOFF DAMPER CONTROLS ARE REQUIRED | | | FOR OUTDOOR AIR INTAKES IN ACCORDANCE WITH FBCEB 611.1 | | | AND FBCB 13-409.1.ABC.3.3. | | | | | | 3. SUPPLY DUCT AND GRILL SERVING JANITOR?S CLOSET IS | | | MISSING DUCT SIZE, CFM AND GRILL DESIGNATION. PROVIDE | | | MISSING INFORMATION. FBCM 603.1, FBCB 106.1.1. | | | | | | 4. PLAN IS NOT CLEAR AS TO WHETHER THE DUCT SHOWN ON | | | PLANS IS TO BE ABOVE A CEILING OR EXPOSED BELOW THE | | | CEILING. PLEASE CLARIFY. THIS INFORMATION AS WELL AS | | | ADDITIONAL INFORMATION IS REQUIRED TO DEMONSTRATE | | | ENERGY CODE COMPLIANCE FOR THE AIR DISTRIBUTION SYSTEM. | | | SEE THE FOLLOWING SECTIONS: FBCB 13-410.1.ABC.2 AND | | | 13-410.1.ACB.3. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-06 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-06 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-07-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-18 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-18 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2008-07-18 16:51:49 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | ******FROM PREVIOUS REVIEWS: | | | | | | 1. SHT A-3 DETAIL D-1 INDICATES THE W/C'S TO BE 1'8" | | | OFF THE WALL TO THE CENTERLINE OF THE FIXTURE. PER FIG | | | 11-28 THE W/C'S SHALL BE 1'6" OFF THE WALL TO THE | | | CENTERLINE OF THE FIXTURE. PLEASE SHOW CORRECT | | | DIMENSION TO THE CENTERLINE OF THE W/C'S. ****RESPONSE | | | FROM ENGINEER STATES: "PLEASE REFER TO RESPONSE BY | | | "ARCHITECT OF RECORD". NO RESPONSE FROM ARCHITECT OF | | | RECORD. COMMENT NOT ADDRESSED. | | | ******NO RESPONSE, COMMENT NOT ADDRESSED. | | | | | | 2. SHT A-3 DETAIL D-2 PLEASE SHOW COMPLIANCE WITH | | | SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | | DIFFICULTY BENDING OR STOOPING. | | | ****RESPONSE FROM ENGINEER STATES: "PLEASE REFER TO | | | RESPONSE BY "ARCHITECT OF RECORD". NO RESPONSE FROM | | | ARCHITECT OF RECORD. COMMENT NOT ADDRESSED. | | | ******NO RESPONSE, COMMENT NOT ADDRESSED | | | | | | 3. OK | | | | | | ***********NEW COMMENTS********** | | | NEW SHEETS SUBMITTED | | | | | | 1B. OK | | | 2B. OK | | | 3B. OK | | | 4B. OK | | | 5B. SEE ATTACHED SHEET CONCERNING FLORIDA STATUTE | | | 553.80(2)(B) AND THE DESIGN PROFESSIONALS. THIS IS | | | GIVEN AS NOTICE ONLY AT THIS TIME. | | | | | | 6B. ONE SET OF PLANS WILL BE RETAINED BY THIS OFFICE | | | FOR POSSIBLE REVIEW BY THE ARCHITECTURAL, ENGINEER & | | | SURVEY BOARDS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-06-05 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-06-05 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2008-06-05 10:10:36 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. SHT A-3 DETAIL D-1 INDICATES THE W/C'S TO BE 1'8" | | | OFF THE WALL TO THE CENTERLINE OF THE FIXTURE. PER FIG | | | 11-28 THE W/C'S SHALL BE 1'6" OFF THE WALL TO THE | | | CENTERLINE OF THE FIXTURE. PLEASE SHOW CORRECT | | | DIMENSION TO THE CENTERLINE OF THE W/C'S. ****RESPONSE | | | FROM ENGINEER STATES: "PLEASE REFER TO RESPONSE BY | | | "ARCHITECT OF RECORD". NO RESPONSE FROM ARCHITECT OF | | | RECORD. COMMENT NOT ADDRESSED. | | | | | | 2. SHT A-3 DETAIL D-2 PLEASE SHOW COMPLIANCE WITH | | | SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | | DIFFICULTY BENDING OR STOOPING. | | | ****RESPONSE FROM ENGINEER STATES: "PLEASE REFER TO | | | RESPONSE BY "ARCHITECT OF RECORD". NO RESPONSE FROM | | | ARCHITECT OF RECORD. COMMENT NOT ADDRESSED. | | | | | | 3. OK | | | | | | ***********NEW COMMENTS********** | | | NEW SHEETS SUBMITTED | | | | | | 1B. SHT 90-038 SURVEY NOT SEALED OR DATED AS REQUIRED | | | IN FS 472.025(1) | | | | | | 2B. SHTS SP-1, A-1, A-2, A-3 & A-4 ARE NOT SIGNED, | | | SEALED & DATED AS REQUIRED. FAC 61G1-16.003, | | | 61G16-004(5) AND FS 481.2055. | | | | | | 3B. SHTS PL 1.00, PL 2.00 & PL 3.00 REQUIRES THE | | | BUSINESS LICENSE, (CERTIFICATE OF AUTHORIZATION), AND | | | THE PRINTED NAME OF THE PERSON SEALING THE DOCUMENT IN | | | THE TITLE BLOCK OF EACH SHEET. FAC 61G1-16.004(2)(6) & | | | FS 481.306, 481.319. | | | | | | 4B. LAST NEW SHEET HAS NO TITLE BLOCK AND IS NOT | | | SIGNED, SEALED, DATED. IF THE DESIGN PROFESSIONAL IS AN | | | ARCHITECT OR ENGINEER LEGALLY REGISTERED UNDER THE LAWS | | | OF THIS STATE REGULATING THE PRACTICE OF ARCHITECTURE | | | AS PROVIDED FOR IN CHAPTER 481, FLORIDA STATUTES, PART | | | I, OR ENGINEERING AS PROVIDED FOR IN CHAPTER 471, | | | FLORIDA STATUTES, THEN HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS AS | | | REQUIRED BY FLORIDA STATUTES. SECTION 106.1. | | | | | | 5B. SEE ATTACHED SHEET CONCERNING FLORIDA STATUTE | | | 553.80(2)(B) AND THE DESIGN PROFESSIONALS. THIS IS | | | GIVEN AS NOTICE ONLY AT THIS TIME. | | | | | | 6B. ONE SET OF PLANS WILL BE RETAINED BY THIS OFFICE | | | FOR POSSIBLE REVIEW BY THE ARCHITECTURAL, ENGINEER & | | | SURVEY BOARDS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-04-12 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-04-12 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2008-04-12 11:38:50 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. SHT A-3 DETAIL D-1 INDICATES THE W/C'S TO BE 1'8" | | | OFF THE WALL TO THE CENTERLINE OF THE FIXTURE. PER FIG | | | 11-28 THE W/C'S SHALL BE 1'6" OFF THE WALL TO THE | | | CENTERLINE OF THE FIXTURE. PLEASE SHOW CORRECT | | | DIMENSION TO THE CENTERLINE OF THE W/C'S. | | | | | | 2. SHT A-3 DETAIL D-2 PLEASE SHOW COMPLIANCE WITH | | | SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | | DIFFICULTY BENDING OR STOOPING. | | | | | | 3. SHT P-4 ELECTRIC WATER HEATER DETAIL. SHOW | | | COMPLIANCE WITH SECTION 607.3.2 THERMAL EXPANSION | | | CONTROL. INDICATE METHOD. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-24 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-24 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2008-06-24 14:52:59 | ***APPROVED - RESUB #1 (CONTRACTOR MISTAKENLY SUBMITTED | | | PHASE II DRAWINGS (SCOPE OF WORK NOW AS ORIGINALLY | | | SUBMITTED))*** | | | | | | NOTE:ADA RAMP ENCROACHES REQUIRED SETBACK OF TWO (2) | | | FEET, HOWEVER, OK PER AJV. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-09 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-09 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2008-06-09 08:09:24 | ***FAILED - RESUB #1 (SCOPE OF WORK INCREASED)*** | | | | | | | | | 1)AS THE SCOPE OF WORK HAS BEEN INCREASED (ADDITION | | | OF CANOPIES, PARKING, AND LANDSCAPING), THE DECLARED | | | VALUE SHALL BE INCREASED TO ACCURATELY REFLECT THE | | | WORK.ANY ADDITIONAL PEMIT FEES SHALL BE PAID | | | ACCORDINGLY. | | | | | | 2)ANY/ALL SIGNAGE SHALL BE PERMITTED SEPARATELY. | | | COPY TO BE REMOVED FROM PLANS OR LABELED "TO BE | | | PERMITTED SEPARATELY". | | | | | | 3)PURSUANT TO SECTION 94-305(E) OF THE CITY'S ZONING | | | AND LAND DEVELOPMENT REGULATIONS (ZLDRS):VISIBILITY | | | AT INTERSECTIONS.AT ANY ROAD INTERSECTIONS, | | | VISIBILITY SHALL NOT BE OBSCURED BY THE CONSTRUCTION, | | | PLACEMENT, OR MAINTENANCE OF A STRUCTURE WALL, SIGN, | | | FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY SIMILAR | | | ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT WITHIN A | | | TRIANGLE BEGINNING AT THE POINT WHERE PROPERTY LINES | | | MEET AT THE CORNER, THEN 20 FEET ALONG THE FRONT | | | PROPERTY LINE, THENCE DIAGONALLY TO A POINT ALONG THE | | | SIDE PROPERTY LINE 20 FEET FROM THE POINT OF BEGINNING, | | | AND THENCE TO THE POINT OF BEGINNING. IN THE EVENT THE | | | CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT | | | SHALL BEGIN AT THE POINT THE PROPERTY LINES WOULD MEET | | | WITHOUT ROUNDING. (SEE FIGURE X-1) | | | | | | NO PLANT MATERIAL SHALL ENCROACH THE VISIBILITY | | | TRIANGLE AT THE CORNER OF DIXIE HIGHWAY AND MADDOCK | | | STREET.REVISE PROPOSED PLANT MATERIAL TO A SIZE LESS | | | THAN 18" IN HEIGHT AT MATURITY.NOTE: REQUIRED SHADE | | | TREE AT LANDSCAPE TERMINAL ISLAND SHALL BE SHOWN | | | OUTSIDE OF THE VISIBILITY TRIANGLE. | | | | | | 4)PROPOSED LIGHTING SHALL BE SHOWN OUTSIDE OF THE | | | VISIBILITY TRIANGLE (SECTION 94-305(E)) AND SHALL NOT | | | INTERFERE WITH ANY REQUIRED LANDSCAPING MATERIAL. | | | | | | 5)NORTH ARROW IS NOT CORRECT ON PLANTING PLAN (SHEET | | | PL 1.00).REVISE. | | | | | | 6)SITE PLAN (SHEET SP-1) AND PLANTING PLAN (SHEET PL | | | 1.00) DO NOT MATCH WITH RESPECT TO THE REQUIRED 5' | | | LANDSCAPE BUFFER AT THE NORTH SIDE OF THE PROPERTY. | | | REVISE SO ALL PLANS AND DIMENSIONS COORELATE.PLEASE | | | SHOW ALL DIMENSIONS OF REQUIRED ISLANDS/BUFFERS. | | | | | | 7)PURSUANT TO SECTION 94-443(B)(4) OF THE THE ZLDRS: | | | AT LEAST ONE SHADE OR FLOWERING TREE SHALL BE PLANTED | | | IN A REQUIRED BUFFER STRIP FOR EACH 30 LINEAR FEET OR | | | PORTION THEREOF. PAVED AREAS USED FOR PEDESTRIAN | | | CIRCULATION AND VEHICULAR ACCESS SHALL BE INCLUDED WHEN | | | CALCULATING THE LENGTH OF THE BUFFER STRIP. TREES MAY | | | BE CLUSTERED OR PLANTED IRREGULARLY AS DEEMED | | | APPROPRIATE. CLUSTERING OF REQUIRED TREES SHALL BE | | | SUBJECT TO CITY APPROVAL. | | | | | | PROVIDE SHADE TREES EVERY 30' ALONG DIXIE HIGHWAY | | | FRONTAGE AS REQUIRED BY THIS SECTION. | | | | | | 8)ALL REQUIRED LANDSCAPE ISLANDS/TERMINAL ISLANDS | | | SHALL MEET THE MINIMUM REQUIRED 5' WIDTH, MEASURED FROM | | | THE INSIDE OF THE CURBING.PLEASE REVISE/RECONFIGURE | | | NORTHERN MOST INTERIOR ISLAND AND NORTH TERMINAL ISLAND | | | (DIRECTLY WEST OF FRONT BUILDING FACADE) TO REFLECT THE | | | MINIMUM WIDTH. | | | | | | 9)AS THE WESTERN-MOST ROW OF PARKING ALONG DIXIE | | | HIGHWAY EXCEEDS THE LENGTH OF 10 CONTIGUOUS PARKING | | | SPACES, THE REQUIRED 5' INTERIOR ISLAND SHALL BE | | | PROVIDED, OR THE ROW/TERMINAL ISLANDS SHALL BE | | | RECONFIGURED SO-AS NOT TO EXCEED THE LENGTH OF 10 | | | STANDARD PARKING SPACES. | | | | | | 10)TWO (2) DIFFERENT SITE PLANS HAVE BEEN SUBMITTED, | | | ONLY ONE NEED BE SUBMITTED WITH THE PROPOSED SCOPE OF | | | WORK ON IT. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-04-14 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-04-14 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2008-04-14 15:14:22 | ***APPROVED*** | | | | | | NOTE:ADA RAMP ENCROACHES REQUIRED SETBACK OF TWO (2) | | | FEET, HOWEVER, OK PER AJV. |
|
|