| Plan Review Stops For Permit 08030667 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-10-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-08 |
Time |
08:04 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-10-08 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2008-10-08 08:05:37 | REVISION "E" SHEET A-1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-16 |
Time |
11:46 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-06-16 |
Time |
11:46 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-22 |
Time |
06:59 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2008-04-22 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2008-04-22 07:38:24 | BUILDING PLAN REVIEW | | | PERMIT: 08030667 | | | ADD: 701 NORTHPOINT PARKWAYSUITES 200& 215 | | | CONT: FISHER CONTRACTING | | | TEL: (561)691-4716 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS | | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | | | 1C)INFORMATIONAL106.1.1* W.P.B. ADMINISTRATIVE | | | CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR | | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) INFORMATIONAL FL S S 713.13NOTICE OF | | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1E)INFORMATIONAL: PLANS SUBMITTED FOR PERMIT (FIRST | | | TIME REVIEW) AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO | | | THE 2004 FBC BUILDING WITH THE2007 SUPPLEMENTS NOT | | | THE 2006 SUPPLEMENTS. | | | PLEASE MAKE CORRECTION. | | | | | | 2) SHEET E2 INDICATES EMERGENCY BACK UP LIGHTS AND EXIT | | | LIGHT LOCATED IN THE STORAGE ROOM. PLEASE SEE 1013.2 | | | EGRESS THROUGH INTERVENING SPACES. EGRESS SHALL NOT | | | PASS THROUGH STORAGE ROOMS. | | | | | | 3) SHEET A-1 INDICATES THE DEMO- WALLS AND THE NEW | | | FLOOR PLAN. THE PLANS INDICATE THIS IS A FULLY | | | SPRINKLERED BUILDING BUT THERE ARE NO FIRE SPRINKLER | | | PLAN FOR EXISTING LAYOPUT OR NEW HEADS TO BE ADDED, | | | PLEASE PROVIDE ADDITIONAL INFORMATION 106.1.2., AND | | | 604.2 EXISTING BUILDING CODE 604.2. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE.) | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2008-11-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-11-10 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-11-10 |
Time |
14:12 |
Sent To |
PC |
|
| Notes |
| 2008-11-10 14:13:08 | REV #5 ON LAYOTU | | | REV# 3 ON RISER, ADD SUB PANEL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-06 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-06 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2008-10-06 13:31:15 | REV#4 E-1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-06 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-06 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2008-10-06 13:30:54 | REV #3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-26 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-26 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-04 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-04 |
Time |
09:31 |
Sent To |
M |
|
| Notes |
| 2008-08-04 09:32:08 | | | | **DENIED4TH REVIEW** | | | | | | ** COMMENT FROM PREVIOUS REVIEW IS STILL IN NEED OF | | | ATTENTION ALONG WITH SEVERAL NEW COMMENTS BASED ON | | | CHANGE OF USE IN SOME ROOMS. | | | | | | | | | 1) NOTE: PLEASE COORDINATE ALL SHEETS IN SETS. PLEASE | | | SEE NOTES FROM PREVIOUS REVIEW WHICH REQUEST TO REMOVE | | | ALL SHEETS AND ONLY INSERT NEW SHEETS INTO THE | | | COMPLETED SETS. THE NEW PLANS SUBMITTED HAVE SHEETS | | | FROM PREVIOUS REVIEW DATED BACK TO PLANS SIGNED AND | | | SEALED IN MARCH. | | | | | | 2) NOTE: PLEASE SEE 13-415.2, 13-415.2.ABC.1.1, .1.2, | | | 13-415.2.B.1. | | | PLEASE PROVIDE THE CORRECT USE ON INPUT DATA REPORT AND | | | SUMMARY SHEETS. IF MEDICAL THEN MEDICAL USE SHOULD BE | | | STATED IN THOSE AREAS. | | | | | | 3) NOTE: IT IS THE UNDERSTANDING OF THIS OFFICE THAT | | | SOME MEDICAL PROCEDURES WILL BE IN SOME LOCATIONS IN | | | THIS BUILD OUT. PLEASE SEE IN FACT THE LIGHTING PLANS | | | HAVE NOW BEEN UPDATED TO INCLUDE A NOTE FOR WIRING OF | | | LIGHTS AND ALSO A NEW UPS FOR BACK UP AS REQUIRED PER | | | NEC 517.45. IN FACT THE PLANS ALSO NOTE TO SEE E-1 FOR | | | DETAILS HOWEVER E-1 SHEETS ARE THE SAME SHEETS | | | PREVIOUSLY SUBMITTED THROUGH OUT PROJECT WITH NO NEW | | | DESIGNS. | | | THE RISER AND BRANCH CIRCUITS ON PANELS DO NOT INDICATE | | | ANY UPS SYSTEM FOR BACK UP POWER. | | | THE PLANS DO NOT INCLUDE ANY INFORMATION FOR TIME OF | | | BACK UP. | | | THE PLANS DO NOT INDICATE ANY LOCATIONS FOR EQUIPMENT | | | OR WIRING OF SYSTEMS. | | | THE PLANS DO NOT INDICATE THE REDUNDANT GROUNDING AS | | | REQUIRED PER 517.10 | | | PLEASE SEE 517 FOR ALL AREAS WHICH ARE SPECIFIC TO | | | MEDICAL USE. | | | | | | 4) NOTE: PLANS WILL BE ROUTED TO ALL OTHER TRADES FOR | | | REVIEW OF ROOMS FOR MEDICAL PROCEDURES. | | | | | | | | | | | | ** IF THERE ARE ANY QUESTIONS OR IF THE COMMENTS ARE | | | NOT CLEAR IN ANY MANOR PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | | | | | | | IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-07-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-09 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-09 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2008-07-09 13:16:49 | ** DENIEDREVIEW ** | | | | | | 1) NOTE: PLEASE SEE THE NOTES FROM PREVIOUS REVIEW. | | | THIS OCCUPANCY IS NOT A HOSPITAL WITH OPERATING ROOMS | | | ETC. IF THIS IS GOING TO CONTAIN OPERATING ROOMS AND | | | ANY USE WHICH FALLS UNDER THE DEFINITIONS OF A HOSPITAL | | | THEN ALL PLANS FOR ALL TRADES INCLUDING BUILDING, | | | MECHANICAL AND PLUMING NEED TO BE REVISED ACCORDINGLY | | | TO MEET REQUIREMENTS OF A HOSPITAL. | | | AS THIS IS NOT A HOSPITAL, MAY NOT USE ALLOWANCES FOR A | | | HOSPITAL, OPERATING ROOMS ETC. PLEASE ADJUST. | | | PLEASE SEE 13-415.2, 13-415.2.ABC.1.1, .1.2 AND TABLE | | | 13-415.2.B. | | | PLEASE BE SURE ALL OTHER COMPONENTS ARE FILLED OUT IN | | | THE INPUT DATA REPORT. | | | WHERE IS PIPING? | | | WHERE IS HOT WATER HEATING? | | | ** THESE ARE SOME ITEMS WHICH ARE MOST CERTAINLY | | | REQUIRED BY CODE AS WELL AS SHOWN ON PLANS. | | | 13-411, 13-412 ETC | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-12 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-12 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2008-06-12 14:58:57 | ** DENIED 2ND REVIEW ** | | | | | | 1) NOTE: PLEASE SEE TABLE 13-415.2.C WHICH ALLOWS 1.0 | | | WATTS PER SQ FT BASED ON THIS OCCUPANCY. THIS IS NOT A | | | HOSPITAL. | | | THE SQ FT AREA IS 3467 AND BASED ON OFFICE USE, THE | | | ALLOWANCE FOR GENERAL LIGHTING PER THE TABLE IS 1.0 W | | | PER SQ FT. | | | IF THIS OCCUPANCY IS OR WAS DESIGNATED AS A HOSPITAL | | | SEVERAL OTHER CODE REQUIREMENTS WOULD BE IMPLEMENTED. | | | | | | 2) NOTE: PLEASE SEE 13-415.1.ABC.1.1, .1.2 FOR REQUIRED | | | LIGHTING CONTROLS. THE NEW DETAIL PROVIDED ONLY | | | INDICATES ONE OCCUPANCY SENSOR WALL SWITCH. THE ISSUE | | | IS WHERE AND WHAT CONTROLS ARE SWITCHES GOING TO | | | OPERATE AUTOMATICALLY? | | | NONE OF THOSE OTHER DEVICES SHOW ANY AUTOMATED CONTROL. | | | | | | | | | | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-03 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-02 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2008-04-03 13:37:39 | ** DENIED** | | | | | | 1) NOTE: PLEASE SHOW THE LIGHTING CONTROLS FOR NEW | | | BEING INSTALLED PER 13-415.1.ABC.1.1 AND .1.2. | | | PLEASE SEE SOME SWITCHES DO NOT SHOW WHAT THESE ARE: | | | FOR EXAMPLE: | | | PLEASE SEE THE DOUBLE SS AND THE DOUBLE SS IN SQUARE | | | BOXES. WHAT ARE THESE? | | | PLEASE SEE THE SYMBOL LEGEND THESE COULD NOT BE | | | LOCATED. | | | | | | 2) NOTE: PLEASE BE SURE THE CERTIFICATION SHEET ON THE | | | SUBMITTED CALCULATIONS IS SIGNED, DATED AND SEALED. | | | THE FIRST/COVER SHEET WAS DONE HOWEVER NEED THE CERT | | | SHEET. PLEASE BE SURE THE OWNER AGENT IS ALSO SIGNED. | | | FBC 13-103.1, FAC 61G15-23.002, FS 471.025 | | | | | | 3) NOTE: PLEASE SEE THE PANEL HC MAY NOT BE LOCATED IN | | | THE STORAGE ROOM. PLEASE RE-LOCATE. 408.17,240.24 AND | | | 110.26 | | | | | | 4) NOTE: PLEASE SEE THE CONDUIT TO NEW PANEL HC IS NOT | | | LARGE ENOUGH FOR THE AMOUNT AND THE SIZE OF THE | | | CONDUCTORS. A 3/4 INCH CONDUIT WILL NOT PERMIT 5-#6 AND | | | 1-10#. PLEASE SEE TABLES IN CHAPTER 9 FOR CONDUIT | | | FILL. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2008-04-02 18:02:30 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-10-21 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-10-21 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2008-10-21 09:40:59 | REVISION DATED 9/12/08. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2008-06-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-06-20 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-06-20 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2008-06-20 14:42:05 | *****APPROVED***** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS PLAN REVIEW HAVE BEEN | | | ADDRESSED;PLAN SHEETS A-1, A-4, F-1, & E-2 WERE | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-28 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-28 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2008-04-28 10:57:21 | ***DENIED*** | | | | | | 1) THE PLANS INDICATE AN OCCUPANT LOAD OF 52 UNDER | | | PROJECT DATA. NFPA 101, 2003 SECTION 7.2.1.4.2 REQUIRES | | | EGRESS DOORS TO SWING IN THE DIRECTION OF TRAVEL. | | | PLEASE ADVISE IF EXCEPTION HAS BEEN MET. | | | | | | 2) PLEASE SEE BUILDING COMMENT #2 REGARDING EXITING | | | THROUGH A STORAGE AREA. | | | | | | 3) PLANS INDICATE FIRE ALARM EQUIPMENT. PLEASE ADD TO | | | ELECTRICAL LEGEND TO VERIFY SPECIFIC EQUIPMENT. | | | | | | 4) PLANS DO NOT ILLUSTRATE FIRE SPRINKLER LAYOUT. | | | SEPARATE SHOP DRAWINGS AND PERMITS ARE REQUIRED FOR | | | BOTH FIRE SPRINKLER AND FIRE ALARM REMODEL WHEN | | | APPLICABLE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-19 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-19 |
Time |
16:47 |
Sent To |
M |
|
| Notes |
| 2008-11-19 16:48:08 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-05 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-05 |
Time |
13:35 |
Sent To |
E |
|
| Notes |
| 2008-11-05 13:36:10 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-09-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-30 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-30 |
Time |
14:31 |
Sent To |
E |
|
| Notes |
| 2008-09-30 14:31:34 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-23 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-23 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2008-09-23 10:36:42 | TO "COMM" BD#52 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-03 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-03 |
Time |
08:50 |
Sent To |
M |
|
| Notes |
| 2008-09-03 08:51:08 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-08-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-15 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-15 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2008-08-15 14:39:46 | TO "COMM" BD#50 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-30 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-30 |
Time |
09:06 |
Sent To |
E |
|
| Notes |
| 2008-07-30 09:06:29 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-24 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-24 |
Time |
15:24 |
Sent To |
E |
|
| Notes |
| 2008-06-24 15:25:31 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-19 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-19 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2008-05-19 14:31:34 | TO "COMM" BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-28 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-03-28 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2008-03-28 14:35:20 | TO "COMM" BD#13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-11-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-24 |
Time |
20:36 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-24 |
Time |
20:35 |
Sent To |
PC |
|
| Notes |
| 2008-11-24 20:36:11 | REVISED M1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-10-18 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-10-18 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-10-18 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2008-10-18 12:15:48 | REVISED M-1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-09-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-09-04 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-09-04 |
Time |
10:39 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-27 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-27 |
Time |
13:55 |
Sent To |
PC |
|
| Notes |
| 2008-08-27 14:05:46 | PREVIOUS REVIEW COMMENTS DATED 8/11/08 HAVE NOT BEEN | | | ADDRESSED (ATTACHED TO THESE COMMENTS FOR REFERENCE). | | | PLEASE NOTE THAT PREVIOUSLY STAMPED PAGES HAVE BEEN | | | VOIDED AS A RESULT OF THE CHANGES MADE AFTER THE PLANS | | | PASSED REVIEW ON 6/4/08. PLEASE REPLACE THE VOIDED | | | PAGES AND MAKE THE NECESSARY CORRECTIONS FROM THE LAST | | | REVIEW AND RESUBMIT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-08-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-11 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-11 |
Time |
15:55 |
Sent To |
PC |
|
| Notes |
| 2008-08-11 16:07:43 | REVIEW #: 3RD | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | SOME ROOMS WITHIN THIS TENANT SPACE HAVE BEEN | | | RECLASSIFIED TO "PROCEDURE" ROOMS, RATHER THAN THE | | | OFFICE OCCUPANCY PREVIOUSLY USED IN THE OUTSIDE AIR | | | CALCULATIONS ON PAGE M-3. THE VENTILATION REQUIREMENTS | | | FOR MEDICAL PROCEDURE ROOMS SHALL BE DETERMINED IN | | | ACCORDANCE WITH TABLE E-1 OF APPENDIX E OF ASHRAE | | | 62.1-2004 PER NOTE 7 OF TABLE 6.1. THIS REQUIRES AN | | | OCCUPANT LOAD OF 20 PPL PER 1000 SQ FT. AND A | | | VENTILATION RATE OF 15 CFM PER PERSON. PLEASE CORRECT | | | THE OUTSIDE AIR CALCULATIONS AND SHOW HOW THE INCREASED | | | VENTILATION RATES WILL BE PROVIDED FOR THESE ROOMS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-04 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-04 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-04-12 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-04-11 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2008-04-12 11:24:02 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PG M-1: STORAGE ROOM 100 SHOWS AN AIR TRANSFER | | | OPENING WITH FIRE DAMPER TO REMAIN IN THE WALL AT | | | CORRIDOR. PG A-1 SHOWS A DOUBLE DOOR BEING DEMOLISHED | | | AND A NEW RATED WALL BEING BUILT AT THIS LOCATION. IS | | | THIS FIRE DAMPER TO BE REMOVED AND REINSTALLED, | | | REPLACED, OR IS IT EXPECTED TO BE UNDISTURBED DURING | | | THIS WALL RECONFIGURATION? PLEASE CLARIFY. FBCM 607.1 | | | AND FBCB 106.1.1 | | | | | | 2. PG M-1: DUCT SMOKE DETECTOR FOR AHU-1 SHALL BE TIED | | | INTO THE BUILDING FIRE ALARM SYSTEM IN ACCORDANCE WITH | | | FBCM 606.4.1. | | | | | | 3. PG M-1: KEYNOTE #12 CALLS FOR REFRIGERANT LINES TO | | | PENETRATE THE FLOOR/CEILING ASSEMBLY TO THE FIRST | | | FLOOR. PROVIDE A THROUGH-PENETRATION FIRESTOP SYSTEM | | | ASSEMBLY DETAIL TO SHOW HOW THESE PENETRATIONS ARE TO | | | BE PROTECTED IN ACCORDANCE WITH FBCB 712.4. | | | | | | 4. PG M-1 AND M-2: ALL RECONFIGURED SPACES INTENDED FOR | | | OCCUPANCY SHALL BE PROVIDED WITH NATURAL OR MECHANICAL | | | VENTILATION OR EXHAUST IN ACCORDANCE WITH FBCEB 609.1 | | | AND FBCM 401.2. AS NATURAL VENTILATION IS NOT BEING | | | PROPOSED, PROVIDE OUTDOOR AIR CALCULATIONS IN | | | ACCORDANCE WITH FBCM TABLE 403.3 OR SECTION 403.4. | | | DECLARE ON PLANS WHICH METHOD IS BEING USED FOR THESE | | | CALCULATIONS. | | | | | | 5. PG M-2: FAN SCHEDULE CALLS FOR EF-10 AND EF-12 TO | | | RUN CONTINUOUSLY, INTERLOCKED WITH AHU-1 FAN. HOWEVER, | | | PG E-2 SHOWS THESE FANS BEING CONTROLLED BY WALL | | | SWITCHES. COORDINATE PLANS, SCHEDULES AND NOTES TO SHOW | | | ACTUAL DESIGN INTENT. FBCM 401.1, FBCB 106.1.1. | | | | | | 6. PG M-1: NOTE #17 CALLS FOR EXHAUST DUCT IN PLENUM TO | | | BE ENCLOSED IN A DUCT. THE EXHAUST DUCT SHALL BE | | | ISOLATED FROM THE PLENUM BY PLENUM CONSTRUCTION USING | | | AN APPROVED PLENUM/AIR BARRIER IN ACCORDANCE WITH FBCM | | | 603.8 TO BE CONSIDERED OUTSIDE THE PLENUM SPACE. ANY | | | OTHER METHOD OF ISOLATION FROM THE PLENUM SPACE SHALL | | | BE SUBMITTED TO THE BUILDING OFFICIAL IN WRITING UNDER | | | THE PROVISIONS OF FBCB 104.11 FOR ALTERNATE MATERIALS | | | AND METHODS. | | | | | | 7. ENERGY CALCULATIONS: MECHANICAL PORTIONS OK. PLEASE | | | SEE ELECTRICAL COMMENT #2 REGARDING SIGNATURE AND SEAL | | | ON THE CERTIFICATION PAGE. | | | | | | NOTE: PLEASE RESPOND TO EACH REVIEW COMMENT IN WRITING | | | TO SPEED THE RESUBMITTAL PROCESS. REMOVE ALL OLD/VOIDED | | | SHEETS FROM RESUBMITTED PLANS AND RETURN ONE OLD SET | | | FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-06-04 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-06-04 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-04-12 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-04-12 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2008-04-12 13:56:19 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | MUNICIPAL CODE CITY WPB | | | | | | 1. SHT A-1 DETAIL #1 IN THE REMOVAL OF ANY PART OF A | | | DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED. SECTION | | | 704.5. DEMO'D PIPING SHALL BE REMOVED BACK TO THE | | | BRANCH LINE OR BLDG DRAIN. | | | | | | 2. SHT A-3 THE FLUSH CONTROLS OF THE W/C SHALL BE ON | | | THE WIDE SIDE OF THE W/C. SECTION 11-4.16.5. (SHOWN ON | | | THE WALL SIDE). | | | | | | 3. SHT P-1 WATER HEATER PIPING DIAGRAM. THE EXPANSION | | | RELIEF VALVE SHALL DRAIN INTO THE HUB DRAIN WITH AN AIR | | | GAP, OR THE WATER HEATER SHALL BE RAISED ABOVE THE PAN | | | DRAIN OPENING. | | | | | | 4. SHT P-1 KEY NOTES #11 INDICATE THE TERMINATION POINT | | | FOR THE CONDENSATE FROM THE AHU. CONDENSATE SHALL NOT | | | DRAIN INTO THE SANITARY SYSTEM, BUT SHALL CONNECT TO A | | | DEDICATED CONDENSATE RISER OR SHALL DRAIN SEPARATELY | | | FROM THE BUILDING. ARTICLE III SECTION 90-125(B)(5). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|