| Plan Review Stops For Permit 08030383 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-17 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-17 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-25 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-25 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2008-03-25 17:37:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.POOL SAFETY NOTE IS NOT COMPLIANT WITH FBC | | | R4101.17, ALARM OR LOCKING DEVICES TO BE USED IN | | | CONJUNCTION WITH A BARRIER, NOT AS A STAND ALONE | | | OPTION. | | | | | | 2.CLARIFY LANGUAGE, POOL SAFETY "POTION".WHAT IS | | | POTION AS RELATED TO THIS PLAN AND POOL SAFETY CODE | | | REQUIREMENTS? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-05-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-05-13 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-05-13 |
Time |
10:27 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-04-07 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-04-07 |
Time |
09:25 |
Sent To |
B |
|
| Notes |
| 2008-04-07 09:35:45 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | THIS COMMENT IS FROM THE PEVIOUS REVIEW: | | | | | | 1} PROVIDE A LOAD CALCULATION FOR THE ELECTRICAL | | | SERVICE INCLUDING ALL LOADS TO BE ADDED UNDER THIS | | | PERMIT. INDICATE THE SIZE OF THE EXISTING SERVICE. | | | | | | THE LOAD CALCULATION SUBMITTED WAS ONLY FOR THE POOL | | | PANEL, NOT THE SERVICE AS REQUESTED. THE CALCULATION | | | SUBMITTED FOR THE POOL SUB-PANEL STATES THAT IT IS TO | | | BE RATED AT 100 AMPS. SHEET 2 OF 2 INDICATES A 50 AMP | | | POOL PANEL. CORRELATE WITH THE DESIGNER OF RECORD. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-21 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-21 |
Time |
13:12 |
Sent To |
P |
|
| Notes |
| 2008-03-21 13:33:53 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | 1} PROVIDE A LOAD CALCULATION FOR THE ELECTRICAL | | | SERVICE INCLUDING ALL LOADS TO BE ADDED UNDER THIS | | | PERMIT. INDICATE THE SIZE OF THE EXISTING SERVICE. | | | | | | 2} PROVIDE MANUFACTURERS SPECIFICATIONS FOR THE POOL | | | HEATER (TWO COPIES). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-03-21 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-21 |
Time |
14:47 |
Sent To |
B |
|
| Notes |
| 2008-03-21 14:47:57 | NOTE: POOL HEATER IN AN ELECTRIC HEAT PUMP. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-08 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-08 |
Time |
12:43 |
Sent To |
E |
|
| Notes |
| 2008-05-08 12:43:41 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-28 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-28 |
Time |
13:32 |
Sent To |
Z |
|
| Notes |
| 2008-03-28 13:36:08 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-25 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-18 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2008-03-18 09:16:47 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-04-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-02 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-02 |
Time |
15:50 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-03-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-03-21 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-21 |
Time |
14:43 |
Sent To |
G |
|
| Notes |
| 2008-03-21 14:47:04 | PLUMBING PLAN REVIEW: | | | DENIED | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | 1) FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | | | | 2) FBC-2004 SEC. 424.2.14.2, OR | | | FBCR-2004 SEC. R4101.14.2 WATER | | | RETENTION, PROVIDE A POSITIVE MEANS OF | | | RETAINING WATER IN THE HEATER WHEN PUMP | | | IS SHUT OFF.(MANUFACTURE SHEETS | | | REQUIRED, PLEASE SUBMIT) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-03-31 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-31 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-31 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2008-03-31 11:29:08 | ***APPROVED - RESUB #1*** | | | | | | NOTE:AS INFRASTRUCTURE ALREADY EXISTS, THE POOL | | | EQUIPMENT LOCATION MAY REMAIN AS APPROVED ERRONEOUSLY | | | BY M.M. ON EXPIRED PERMIT # 06061366 | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-19 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-19 |
Time |
09:32 |
Sent To |
E |
|
| Notes |
| 2008-03-19 09:34:25 | ***FAILED*** | | | | | | | | | 1)INDICATE SETBACK DIMENSIONS FROM PROPOSED POOL | | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | | 94-305(B)(4) OF THE ZLDRS: MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | NOTE: THE REQUIRED REAR SETBACK IS 13.9 FEET (10 % OF | | | LOT DEPTH). | | | | | | 2)AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | | THE MINIMUM STANDARDS PROVIDED BELOW. | | | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C): | | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | | | | NOTE:IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT | | | TO OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN | | | AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|