Plan Review Details - Permit 08030365
Plan Review Stops For Permit 08030365
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-10-24 Cont ID  
Sent By jwitmer Date 2008-10-24 Time 13:57 Rev Time 0.77
Received By jwitmer Date 2008-10-24 Time 13:57 Sent To  
Notes
2008-10-24 13:57:49REVISION# 3 A-1, A-2

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-08-06 Cont ID  
Sent By jwitmer Date 2008-08-06 Time 09:26 Rev Time 2.22
Received By jwitmer Date 2008-08-06 Time 09:26 Sent To PC
Notes
2008-08-06 09:27:11ISSUE PLANS WITH REVISON2& 3.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-06-04 Cont ID  
Sent By jwitmer Date 2008-06-04 Time 09:57 Rev Time 1.77
Received By jwitmer Date 2008-06-04 Time 09:57 Sent To FIRE
Notes
2008-06-04 09:58:252ND REVIEW BUILDING OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-04-11 Cont ID  
Sent By jwitmer Date 2008-04-11 Time 08:21 Rev Time 1.55
Received By jwitmer Date 2008-04-11 Time 08:16 Sent To  
Notes
2008-04-11 10:26:25BUILDING PLAN REVIEW
 PERMIT: 08030365
 ADD: 1411 N FLAGLER 3900
 CONT: JP HURBON, INC
 TEL: (561)685-4358
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE
 INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS,
 PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR
 SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL
 REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A
 THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN
 (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED
 FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS
 WEST PALM BEACH ADMINISTRATIVE CODE.
  
 1C)INFORMATIONAL106.1.1* W.P.B. ADMINISTRATIVE
 CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN
 INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO
 THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO
 CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION
 SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE
 CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR
 ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) INFORMATIONAL FL S S 713.13NOTICE OF
 COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT.
 NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS
 AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL &
 VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF
 COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST
 INSPECTION.
  
 1E): PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW)
 AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC
 BUILDING WITH THE2007 SUPPLEMENTS NOT THE 2006 AS
 STATED ON THE PLANS
 PLEASE CORRECT.
  
 1F) PLANS FAIL TO IDENTIFY THE 2004 EXISTING BUILDING
 CODE/ W 2007 SUPPLEMENTS AND TO WHAT LEVEL OF
 ALTERATION IS TO BE COMPLETED UNDER THIS PERMIT.
  
 2) SHEET M-1 DOES INDICATE A DUCT THAT PASSES THROUGH
 2 (1) HOUR FIRE RATED WALLS BUT NO DAMPERS OR THROUGH
 PENETRATION PLEASE SHOW COMPLIANCE WITH 712.3.1 THROUGH
 PENETRATIONS.
  
 3)SHEET A-1 INDICATES A NURES STATION 112, A DETAIL
 # 5 SHEET A-2 DOES NOT INDICATE THIS STATION BUT A CUR
 SECTION OF THE WAITING ROOM CEILING AND SOFFIR DETAIL.
 THIS AREA APPEARS THAT IT MAY BE A BREAK AREA, IF SO
 SHOW COMPLIANCE WTIH :
 11-4.24.2 HEIGHT. SINKS SHALL BE MOUNTED WITH THE
 COUNTER OR RIM NO HIGHER THAN 34" ABOVE THE FINISH
 FLOOR.
 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30"
 WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS.
 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT
 LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM)
 COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN
 FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR
 FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL
 EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE
 SINK.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
  

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2008-12-26 Cont ID  
Sent By dpalmer Date 2008-12-26 Time 09:00 Rev Time 0.00
Received By dpalmer Date 2008-12-24 Time 16:45 Sent To  
Notes
2008-12-26 09:00:47** REDLINED PLANS**
  
 1) NOTE: THE TOTAL NUMBER OF FIXTURES ON PLANS FOR
 RECESSED LIGHTS IS OVER AMOUNT ON TABLE HOWEVER THIS
 DOES NOT EXCEED OVER ALL ALLOWANCES.
 THE WALL SCONCE FIXTURES ARE NOT LISTED ON FIXTURE
 LEGEND AND NEEDS TO BE VERIFIED.
 THE LED FIXTURES ARE LISTED WITH A TOTAL OF 200W WHICH
 NEED TO BE VERIFIED.
 NO ALLOWANCE FOR PENDANT FIXTURE COULD BE LOCATED. A
 NOTE FOR THIS TYPE OF FIXTURE MENTIONS ONLY ON DURING
 MEDICAL PROCEDURES HOWEVER THESE ARE ALSO IN THE
 CONFERENCE ROOM. BASED ON THE MAXIMUM WATTAGE TOTAL OF
 300 FOR ALL THREE FIXTURES THIS WOULD NOT BE OVER
 ALLOWANCES IN TABLE 13-415.2.B AND ADDITIONAL PERMITTED
 UNDER TABLE.
  
  

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2008-10-31 Cont ID  
Sent By dpalmer Date 2008-10-31 Time 13:50 Rev Time 0.00
Received By dpalmer Date 2008-10-31 Time 13:50 Sent To  
Notes
2008-10-31 13:50:35** DENIED REVISION**
  
 1) NOTE: THERE HAVE BEEN SUBSTANTIAL REVISIONS TO FLOOR
 LAYOUT AND ALSO LIGHTING. PLEASE SEE 13-415.2,
 13-415.2.ABC.1.1,.1.2 OF THE FBC TO REVISE LIGHTING
 PERFORMANCE CALCULATIONS.
  
 2) NOTE: PLEASE BE SURE ALL REVISIONS ARE IN
 CONSECUTIVE ORDER OF PREVIOUS PLANS. THIS IS ONLY NOTED
 AS ELECTRICAL REVISIONS AS NOTED ON TITLE BLOCKS ARE
 OK, HOWEVER MAY AFFECT OTHER TRADES OR CHANGES.
  
 3) NOTE: PLEASE BE SURE TO UPDATE ALL CIRCUITING ON
 PLANS WITH THE REVISED PANEL SCHEDULE. NOT ALL CIRCUITS
 SHOWN ON PLANS ARE THE SAME AS THE REVISED PANEL
 SCHEDULE SUBMITTED. AN EXAMPLE OF THIS IS IN ROOM 103
 WHICH INDICATES A RECEPTACLE WITH CIRCUIT L317, 19 YET
 THE PANEL SCHEDULE FOR CIRCUIT 19 INDICATES A
 DISHWASHER IN ROOM 105?
 THIS IS ONE EXAMPLE GIVEN AS A BENEFIT. THERE ARE SOME
 OTHERS.
 408.4
 FBC 106.1.1, 106.5 FOR COORDINATION/CLARITY OF RECORD
 PLANS.
  
  
  
  
  
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-07-28 Cont ID  
Sent By dpalmer Date 2008-07-28 Time 09:55 Rev Time 0.00
Received By dpalmer Date 2008-07-28 Time 09:54 Sent To  
Notes
2008-07-28 09:55:46PROVISO FROM 6/3/08 WAS DONE. REDLINED PLANS TO REMOVE
 PROVISO.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-06-03 Cont ID  
Sent By dpalmer Date 2008-06-03 Time 16:17 Rev Time 0.00
Received By dpalmer Date 2008-06-03 Time 16:16 Sent To  
Notes
2008-06-03 16:26:09** NOTE ADDED:
 AS PLANS WERE REVIEWED AND DENIED BY OTHER TRADES SUCH
 AS PLUMBING AND MECHANICAL THE 30 DAY PROVISO ISSUED ON
 ELECTRICAL SHOULD BE ADDRESSED WHEN PLANS ARE
 RESUBMITTED.
 THE READINGS SHOULD HAVE ALREADY BE UNDERWAY FROM
 LETTER DATED MAY 5TH, 2008 FROM ELECTRICAL CONTRACTOR.
 THE DATE OF THIS ELECTRICAL REVIEW IS 6/3/08 AND THIS
 30 DAY WILL MOST CERTAINLY BE DONE BY THE TIME PLANS
 ARE RE-SUBMITTED.
 PLANS WILL GO INTO A TEMPORARY FAILED STATUS AS OTHER
 TRADES HAVE COMMENTS AND PLANS ARE GOING OUT FOR
 CORRECTIONS.
 ELECTRICAL PLANS ARE ALREADY STAMPED BUT WILL REMAIN
 FAILED UNTIL DOCUMENTATION IS SUBMITTED.
2008-06-03 16:17:10** PROVISO/TEMP FAILED**
  
  
 1) NOTE:AS AGREED BY ELECTRICAL CONTRACTOR AND
 CONVERSATION WITH JOHN LOWEN FROM KNIGHT ELECTRIC,
 ELECTRICAL LOAD DETERMINATION AS REQUIRED PER 220.87
 WILL BE PROVIDED TO THIS OFFICE WITHIN 30DAYS OF THIS
 REVIEW.
 THESE SHALL CLEARLY SHOW THE ELECTRICAL LOADS ON
 EXISTING PANEL *L3* WITH NEW LOADS BEING ADDED. PLANS
 WILL ALSO NEED TO CLARIFY THE LOCATION OF THE EXISTING
 PANELS *L3* AND *L3SS*. THESE MAY NOT BE IN OTHER
 TENANT SPACE.
 PLEASE UNDERSTAND PERMIT MAY BE REVOKED AS PERMITTED BY
 THE IN CHAPTER 1 OF THE FLORIDA BUILDING CODE IF
 PROVISO IS NOT COMPLIED WITH WITHIN TIME FRAME..
  
 THE LETTER SUBMITTED BY THE ELECTRICAL ENGINEER QUOTING
 THIS ELECTRICAL REVIEWER COMMENTS DO NOT SEEM TO BE
 QUOTING THE PREVIOUS ELECTRICAL REVIEW FOR THIS
 PROJECT?
 THE WORDING OF THE REVIEW, THE CODE SECTIONS ETC WERE
 NOT ON THE REVIEW OF PERMIT #08030365 DATED 3/20/08IT
 IS UNCLEAR WHERE THESE NOTES CAME FROM.
 IF THE PROVISO AS SET-FORTH ABOVE IS NOT ACCEPTABLE TO
 THE DESIGN TEAM THIS OFFICE NEEDS TO BE NOTIFIED BEFORE
 PERMIT ISSUANCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF
 THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT
 HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-03-20 Cont ID  
Sent By dpalmer Date 2008-03-20 Time 17:01 Rev Time 0.00
Received By dpalmer Date 2008-03-20 Time 16:42 Sent To  
Notes
2008-03-20 17:01:32** DENIEDREVIEW **
  
  
 1) NOTE:PLEASE CLARIFY PANELS AND CIRCUITING. PANEL
 L3 IS SHOWING A NEW FEED TO NEW PANEL L3A HOWEVER IT IS
 UNCLEAR OF THE LOAD OR SIZE OF THE EXISTING PANEL L3
 WITH NEW LOADS BEING ADDED.
 PLEASE ALSO SEE THE NEW SPACE IS SHOWING SOME CIRCUITS
 COMING FROM EXISTING PANEL L3SS YET IT IS UNCLEAR IF
 THE TENANT HAS ACCESS TO THIS PANEL? WHAT DOES THIS
 PANEL FEED? OTHER TENANTS? IS IT LOCATED IN ANOTHER
 TENANT SPACE?
 PLEASE VERIFY LOADS, 220.87
 PLEASE VERIFY LOCATIONS OF ALL OVER CURRENT PROTECTION
 DEVICES REQUIRED FOR TENANT 240.24
  
 2) NOTE: PLEASE CLARIFY WHAT THE *SD* IS WHICH IS SHOWN
 IN EXAM ROOMS 5 AND 6.
 PLEASE VERIFY DEVICES AND THEIR MAXIMUM TIMES.
  
 COMMENT #2 COULD HAVE BEEN REDLINED AND TO VIF HOWEVER
 COMMENT #1 NEEDS TO BE CLARIFIED AND ADDRESSED AT THIS
 TIME.
  
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2008-11-07 Cont ID  
Sent By mwennerg Date 2008-11-07 Time 14:44 Rev Time 0.00
Received By mwennerg Date 2008-11-07 Time 14:44 Sent To  
Notes
2008-11-07 14:45:21REVISION DATED 9/15/08

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-08-05 Cont ID  
Sent By mawillia Date 2008-08-05 Time 16:07 Rev Time 0.00
Received By mawillia Date 2008-08-05 Time 15:14 Sent To B
Notes
2008-08-05 15:35:06*****APPROVED*****
  
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE
 BEEN ACKNOWLEDGED OR ADDRESSED;PLAN SHEETS A-1 AND
 E-1 WERE STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2008-06-05 Cont ID  
Sent By mwennerg Date 2008-06-05 Time 14:14 Rev Time 0.00
Received By mwennerg Date 2008-06-05 Time 14:13 Sent To  
Notes
2008-06-05 14:16:16***DENIED***
  
 1) OK
  
 2) NO INFORMATION PROVIDED OR ACKNOWLEDGMENT
  
 3) NO INFORMATION PROVIDED OR ACKNOWLEDGMENT
  
 4) OK
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2008-04-15 Cont ID  
Sent By mawillia Date 2008-04-15 Time 14:55 Rev Time 0.00
Received By mawillia Date 2008-04-15 Time 09:53 Sent To  
Notes
2008-04-15 14:50:21*****DENIED*****
  
  
 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 2.PROVIDE A LAYOUT OF THE FIRE SPRINKLER HEADS FOR
 THE REMODELED SPACE.
  
 3.PROVIDE A LAYOUT OF THE FIRE ALARM DEVICES FOR THE
 REMODELED SPACE.
  
 4.PROVIDE TRAVEL DISTANCE TO THE EXIT.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET
 EACH COMMENT WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2009-01-14 Cont ID  
Sent By adarroug Date 2009-01-14 Time 14:54 Rev Time 0.00
Received By adarroug Date 2009-01-14 Time 14:54 Sent To P
Notes
2009-01-14 14:55:01TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-12-04 Cont ID  
Sent By adarroug Date 2008-12-04 Time 11:20 Rev Time 0.00
Received By adarroug Date 2008-12-04 Time 11:20 Sent To  
Notes
2008-12-04 11:23:04TO "COMM" BD#20

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-10-14 Cont ID  
Sent By adarroug Date 2008-10-14 Time 16:49 Rev Time 0.00
Received By adarroug Date 2008-10-14 Time 16:32 Sent To  
Notes
2008-10-14 16:50:04TO "COMM" BD#30

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-11 Cont ID  
Sent By adarroug Date 2008-07-11 Time 09:30 Rev Time 0.00
Received By adarroug Date 2008-07-11 Time 09:30 Sent To  
Notes
2008-07-11 09:33:33TO "COMM" BD#27

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-05-13 Cont ID  
Sent By adarroug Date 2008-05-13 Time 10:14 Rev Time 0.00
Received By adarroug Date 2008-05-13 Time 10:14 Sent To  
Notes
2008-05-13 10:17:58TO "COMM" BD#36

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-04-15 Cont ID  
Sent By mawillia Date 2008-04-15 Time 09:53 Rev Time 0.00
Received By mawillia Date 2008-03-17 Time 16:07 Sent To  
Notes
2008-03-19 13:06:40TO "COMM" BD#4
2008-03-17 16:07:37WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2009-03-24 Cont ID  
Sent By rregueir Date 2009-03-24 Time 18:01 Rev Time 0.00
Received By rregueir Date 2009-03-24 Time 18:01 Sent To PC
Notes
2009-03-24 18:02:02REVISED M-1

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2009-01-10 Cont ID  
Sent By rregueir Date 2009-01-10 Time 18:35 Rev Time 0.00
Received By rregueir Date 2009-01-10 Time 18:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2008-11-02 Cont ID  
Sent By rregueir Date 2008-11-02 Time 13:18 Rev Time 0.00
Received By rregueir Date 2008-11-02 Time 13:14 Sent To  
Notes
2008-11-02 13:18:41REVIEW #: REVISION
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 REVISED M-1 SHOWS RETURN AIR TRANSFER DUCTS ELIMINATED
 AND ALL ABOVE CEILING SPACES USED AS PLENUMS. THIS WILL
 CREATE A SITUATION WHERE EXHAUST FANS AND THEIR
 POSITIVELY PRESSURIZED EXHAUST DUCTS WILL BE LOCATED
 WITHIN THE PLENUM SPACE. EXHAUST DUCTS UNDER POSITIVE
 PRESSURESHALL NOT EXTEND INTO OR PASS THROUGH DUCTS OR
 PLENUMS IN ACCORDANCE WITH FBCM 601.3. SHOW HOW THESE
 EXHAUST DUCTS ARE TO BE ISOLATED FROM THE PLENUM IN
 ACCORDANCE WITH THIS SECTION. ALSO, SHOW HOW THE NEWLY
 CREATED PLENUM SPACE WALLS ABOVE THE CEILING ARE TO BE
 FINISHED IN ACCORDANCE WITH FBCM 603.8 AND FBCM 603.9.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-07-24 Cont ID  
Sent By rregueir Date 2008-07-24 Time 11:29 Rev Time 0.00
Received By rregueir Date 2008-07-24 Time 11:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-05-30 Cont ID  
Sent By rregueir Date 2008-05-30 Time 10:51 Rev Time 0.00
Received By rregueir Date 2008-05-30 Time 08:57 Sent To  
Notes
2008-05-30 10:51:40REVIEW #: 2ND
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH
 PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN
 RESPONSES FOR THE PURPOSE OF CONTINUITY.
  
 1. OK
  
 2. NOT E ON FAN SCHEDULE SAYS ?PROTECT ALL RATED WALLS
 WITH FIRE/SMOKE AS REQUIRED BY CODE.? THIS NOTE IS NOT
 IS NOT SUFFICIENT TO DEMONSTRATE CODE COMPLIANCE. THE
 SPECIFIC LOCATION OF EACH FIRE DAMPER, CEILING DAMPER
 AND SMOKE DAMPER SHALL BE SHOWN AND PROPERLY IDENTIFIED
 ON THE BUILDING PLANS BY THE DESIGNER IN ACCORDANCE
 WITH FBCM 607.8.
  
 3. SIZE OF SOME RETURN AIR FLEX DUCTS STILL MISSING ON
 PLANS. THE TWO MAIN FLEX RETURN DUCTS FROM THE MAIN
 RETURN TRUNK LINE TO THE DOUBLE 24X24 GRILLS IN THE
 HALL DO NOT HAVE A SIZE SHOWN ON PLANS. ALSO, THE
 RETURN FLEX IN CONFERENCE ROOM 106 NOW HAS TWO SIZES.
 IN ONE LOCATION IT IS SHOWN AS 12 INCH AND IN ANOTHER
 IT IS SHOWN AS 8 INCH. WHICH IS CORRECT? PLEASE
 CLARIFY, SHOWING COMPLIANCE WITH FBCM 601.4.
 ADDITIONALLY, MOHS LAB 107 HAS A NOTE FOR 150 CFM. DOES
 THIS APPLY TO THE SUPPLY REGISTER OR THE EXHAUST FAN?
 THE DUCT SIZE FOR THIS SUPPLY REGISTER IS MISSING FROM
 PLANS.
  
 4. OK
  
 5. OK
  
 6. IN MOHS LAB 107 THERE IS AN EXHAUST FAN SHOWN IN THE
 CEILING. IS THIS THE SAME TYPE OF FAN AS EF-1 ON THE
 FAN SCHEDULE OR IS IT A 150 CFM FAN AS THE NOTE ON THE
 FLOOR PLAN INDICATES? WHERE IS THE DUCT FOR THIS FAN
 AND WHAT SIZE IS THE DUCT? SEE COMMENT #2 ABOVE FOR
 ISSUES RELATED TO EXHAUST FAN DUCTWORK.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2008-03-29 Cont ID  
Sent By rregueir Date 2008-03-29 Time 17:05 Rev Time 0.00
Received By rregueir Date 2008-03-29 Time 16:16 Sent To  
Notes
2008-03-29 17:05:32REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. M-1 PLAN STATES THE HVAC DESIGN IS BY ALTMAN
 BROTHERS, LLC. AN INSTALLING AIR-CONDITIONING
 CONTRACTOR CERTIFIED UNDER CHAPTER 489, FLORIDA
 STATUTES MAY DESIGN AN AIR CONDITIONING SYSTEM UNDER 15
 TONS ONLY IF THIS SYSTEMS SERVES A BUILDING WITH LESS
 THAN 100 OCCUPANTS, THE SYSTEMS HAS INDEPENDENT DUCTS
 AND COSTS LESS THAN $50,000. AS THIS SPACE IS BEING
 SERVED BY A VAV BOX FED BY A LARGER A/C SYSTEM IN A
 BUILDING WITH AN OCCUPANT LOAD GREATER THAN 100, THIS
 SYSTEM IS NOT ELIGIBLE TO BE DESIGNED BY AN AIR
 CONDITIONING CONTRACTOR. THIS PLAN SHALL BE SIGNED AND
 SEALED BY A PROFESSIONAL ENGINEER IN ACCORDANCE WITH
 FBCB 105.3.1.2.
  
 2. M-1: FLOOR PLAN SHOWS 10 INCH ROUND DUCT PENETRATING
 TWO NEW 1-HOUR RATED CORRIDOR WALLS. SHOW HOW THESE
 PENETRATIONS ARE TO BE PROTECTED IN ACCORDANCE WITH
 FBCM 607.5 AND 607.1.1.
  
 3. M-1: PROVIDE SIZE OF RETURN AIR FLEX DUCTS TO SHOW
 HOW BALANCED RETURN IS BEING ACHIEVED IN ACCORDANCE
 WITH FBCM 601.4. IF TRANSFER DUCTS ARE NOT DESIGNED TO
 MEET THE EXCEPTIONS UNDER THIS SECTION, A FIELD TEST
 WILL BE REQUIRED AT FINAL INSPECTION TO DETERMINE IF
 PRESSURE DIFFERENTIALS ACROSS CLOSED DOORS ARE AT 0.01
 INCHES WC OR LESS.
  
 4. M-1 FIRE DAMPER DETAIL, NOTE #1: FIRE DAMPERS AND
 SMOKE DAMPERS LOCATED WITHIN AIR DISTRIBUTION AND SMOKE
 CONTROL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH
 THE REQUIREMENTS OF THIS SECTION, AND THE
 MANUFACTURER?S INSTALLATION INSTRUCTIONS AND LISTING
 REGARDLESS OF THE DETAIL ON THE PLANS AS THESE DAMPERS
 ARE PART OF A LISTED AND TESTED ASSEMBLY IN ACCORDANCE
 WITH FBCM 607.2 AND 607.3.
  
 5. THIS WORK IS BEING PROPOSED IN AN EXISTING BUILDING;
 THEREFORE THE DESIGN PROFESSIONAL MUST ELECT ONE OR A
 COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THE FLORIDA EXISTING
 BUILDING CODE IN ACCORDANCE WITH FBCEB 301.5. AS A
 LEVEL OF ALTERATION HAS NOT BEEN DECLARED, FOR THE
 PURPOSE OF THIS REVIEW, IT IS BEING ASSUMED THAT THIS
 IS A LEVEL 2 ALTERATION AS DEFINED IN FBCEB 304.1.
  
 6. M-1: NO INFORMATION WAS PROVIDED REGARDING THE
 TOILET ROOM EXHAUST FAN OR ANY OTHER ASPECT OF
 VENTILATION REQUIREMENTS FOR THIS SPACE. ALL
 RECONFIGURED SPACES INTENDED FOR OCCUPANCY IN ANY WORK
 AREA SHALL BE PROVIDED WITH NATURAL OR MECHANICAL
 VENTILATION OR EXHAUST IN ACCORDANCE WITH THE FBCEB
 609.1. SHOW VENTILATION AND EXHAUST RATES TO BE IN
 COMPLIANCE WITH FBCM SECTION 403.3. PROVIDE OUTSIDE AIR
 CALCULATIONS, INCLUDING OCCUPANCY CLASSIFICATIONS,
 OCCUPANT LOADS, OUTSIDE AIR REQUIRED AND OUTSIDE AIR
 PROVIDED FOR EACH SPACE IN ACCORDANCE WITH FBCM TABLE
 403.3.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 6 Status P Date 2009-01-20 Cont ID  
Sent By lwagner Date 2009-01-20 Time 13:44 Rev Time 0.00
Received By lwagner Date 2009-01-20 Time 13:16 Sent To  
Notes
2009-01-20 13:43:57REVISION OK

Review Stop P PLUMBING
Rev No 5 Status P Date 2009-01-12 Cont ID  
Sent By lwagner Date 2009-01-12 Time 11:24 Rev Time 0.00
Received By lwagner Date 2009-01-12 Time 11:09 Sent To  
Notes
2009-01-12 11:10:09REVISION OK -SHEET P-1

Review Stop P PLUMBING
Rev No 4 Status F Date 2008-10-28 Cont ID  
Sent By kstevens Date 2008-10-28 Time 10:24 Rev Time 0.00
Received By kstevens Date 2008-10-28 Time 10:24 Sent To  
Notes
2008-10-28 10:49:36REVISION DENIED
 REFERENCE: FBC-2004 CHAPTER 1
 FBC-2004 PLUMBING
  
 1. SHT P-1 INDICATES REVISION #3 DATED 9-15-2008. OUR
 FILE SET OF PLANS HAS A REVISION #3 DATED 7-3-2008. THE
 REVISIONS SHALL BE IN SEQUENCE AND PREVIOUS REVISIONS
 SHALL NOT BE DELETED FROM THE REVISION INDEX/MATRIX.
 SECTION 106.1.3. PLEASE SHOW NEW REVISION AS REVISION
 #4 OR ABOVE AND SHOW THE PREVIOUS REVISION #3 IN
 REVISION INDEX.
  
 2. SHT P-1 SANITARY RISER DIAGRAM, THE FOUR SINKS IN
 THE EXAM ROOM ARE NOT VENTED. SECTION 901.2.1. (AN AAV
 ON ONE SINK AT EACH SUMP WILL MEET THIS REQUIREMENT).
  
 3. SHT P-1 THE FOUR SINKS SHALL DRAIN INTO THE SUMP NOT
 THE DISCHARGE LINE ON THE SANITARY RISER DIAGRAM.
 SECTION 712.1. SHOW THE SINKS DRAINING TO THE SUMP.
  
 4. SHT P-1 SANITARY RISER DIAGRAM SHOWS SHUT OFF VALVES
 ON THE DISCHARGE SIDE OF THE CHECK VALVES. SECTION
 712.2 REQUIRES A FULL OPEN VALVE. PLEASE INDICATE ON
 RISER DIAGRAM.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-08-06 Cont ID  
Sent By kstevens Date 2008-07-28 Time 07:51 Rev Time 0.00
Received By kstevens Date 2008-07-28 Time 15:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-05-28 Cont ID  
Sent By kstevens Date 2008-05-28 Time 16:06 Rev Time 0.00
Received By kstevens Date 2008-05-28 Time 16:06 Sent To  
Notes
2008-05-28 16:10:24DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FLORIDA STATUTES
  
 ****FROM PREVIOUS REVIEW: (2ND REVIEW)
  
 1. OK
  
 2. SHT P-1 SANITARY RISER DIAGRAM THE SINKS IN ROOMS
 109 & 110 SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL
 WET VENT PER SECTION 909.1.
 ****RESPONSE NOTED, BUT THE SINKS STILL DRAIN THRU THE
 HORIZONTAL WET VENT FOR THE TOILET ROOM. THE LAV IS THE
 VENT FOR THE WATER CLOSET ONLY. (SEE RED LINE
 CORRECTION ON ONE SET OF PLANS).
  
 3. OK
 4. OK
 5. OK
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-04-11 Cont ID  
Sent By kstevens Date 2008-04-11 Time 17:07 Rev Time 0.00
Received By kstevens Date 2008-04-11 Time 17:07 Sent To  
Notes
2008-04-11 17:25:55DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FLORIDA STATUTES
  
 1. SHT P-1 SANITARY RISER DIAGRAM INDICATES THE PIPE
 SIZE AS 2" CONNECTING TO THE STACK AND UP TO THE TOILET
 ROOM. MINIMUM 3" REQUIRED TO THE W/C PER TABLE 709.1.
  
 2. SHT P-1 SANITARY RISER DIAGRAM THE SINKS IN ROOMS
 109 & 110 SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL
 WET VENT PER SECTION 909.1.
  
 3. SHT P-1WATER RISER DIAGRAM SHALL SHOW ALL PIPE
 SIZES, AND INDICATE THE LOCATION OF THE CONNECTION TO
 THE WATER MAIN. SECTIONS 106.1.2, 601.1 &604.
  
 4. SHT P-1 THE HUB DRAIN FOR THE P/T AND PAN DRAIN FOR
 THE WATER HEATER SHALL HAVE A TRAP PRIMER. SECTION
 1002.4.
  
 5. DESIGN SHALL BE PER FBC-2004 W/2007 AMENDMENTS.
 PLEASE INDICATE ON PLANS. SECTION 106.1.2 & FS
 533.73(1)(A).
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]