| Plan Review Stops For Permit 08030365 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-10-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-10-24 |
Time |
13:57 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-10-24 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2008-10-24 13:57:49 | REVISION# 3 A-1, A-2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-06 |
Time |
09:26 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-08-06 |
Time |
09:26 |
Sent To |
PC |
|
| Notes |
| 2008-08-06 09:27:11 | ISSUE PLANS WITH REVISON2& 3. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-06-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-04 |
Time |
09:57 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2008-06-04 |
Time |
09:57 |
Sent To |
FIRE |
|
| Notes |
| 2008-06-04 09:58:25 | 2ND REVIEW BUILDING OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-11 |
Time |
08:21 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2008-04-11 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2008-04-11 10:26:25 | BUILDING PLAN REVIEW | | | PERMIT: 08030365 | | | ADD: 1411 N FLAGLER 3900 | | | CONT: JP HURBON, INC | | | TEL: (561)685-4358 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1A)INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | 1B) INFORMATIONAL: PLEASE SUBMIT 2 OF ALL SURVEYS, | | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | | SUBMITTALS FOR REVIEW FOR PERMIT. IF YOUR PROJECT WILL | | | REQUIRE A RESIDENT INSPECTOR OR IF YOUR PROJECT IS A | | | THRESHOLD BUILDING REQUIRING A THRESHOLD INSPECTOR THEN | | | (3) THREE SETS OF ALL SAID DOCUMENTS WILL BE REQUIRED | | | FOR PERMIT ISSUANCE. 106.1* /2004 SUBMITTAL DOCUMENTS | | | WEST PALM BEACH ADMINISTRATIVE CODE. | | | | | | 1C)INFORMATIONAL106.1.1* W.P.B. ADMINISTRATIVE | | | CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE | | | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR | | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 1D ) INFORMATIONAL FL S S 713.13NOTICE OF | | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 1E): PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE2007 SUPPLEMENTS NOT THE 2006 AS | | | STATED ON THE PLANS | | | PLEASE CORRECT. | | | | | | 1F) PLANS FAIL TO IDENTIFY THE 2004 EXISTING BUILDING | | | CODE/ W 2007 SUPPLEMENTS AND TO WHAT LEVEL OF | | | ALTERATION IS TO BE COMPLETED UNDER THIS PERMIT. | | | | | | 2) SHEET M-1 DOES INDICATE A DUCT THAT PASSES THROUGH | | | 2 (1) HOUR FIRE RATED WALLS BUT NO DAMPERS OR THROUGH | | | PENETRATION PLEASE SHOW COMPLIANCE WITH 712.3.1 THROUGH | | | PENETRATIONS. | | | | | | 3)SHEET A-1 INDICATES A NURES STATION 112, A DETAIL | | | # 5 SHEET A-2 DOES NOT INDICATE THIS STATION BUT A CUR | | | SECTION OF THE WAITING ROOM CEILING AND SOFFIR DETAIL. | | | THIS AREA APPEARS THAT IT MAY BE A BREAK AREA, IF SO | | | SHOW COMPLIANCE WTIH : | | | 11-4.24.2 HEIGHT. SINKS SHALL BE MOUNTED WITH THE | | | COUNTER OR RIM NO HIGHER THAN 34" ABOVE THE FINISH | | | FLOOR. | | | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30" | | | WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS. | | | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT | | | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) | | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR | | | FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE | | | SINK. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-12-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-26 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-24 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2008-12-26 09:00:47 | ** REDLINED PLANS** | | | | | | 1) NOTE: THE TOTAL NUMBER OF FIXTURES ON PLANS FOR | | | RECESSED LIGHTS IS OVER AMOUNT ON TABLE HOWEVER THIS | | | DOES NOT EXCEED OVER ALL ALLOWANCES. | | | THE WALL SCONCE FIXTURES ARE NOT LISTED ON FIXTURE | | | LEGEND AND NEEDS TO BE VERIFIED. | | | THE LED FIXTURES ARE LISTED WITH A TOTAL OF 200W WHICH | | | NEED TO BE VERIFIED. | | | NO ALLOWANCE FOR PENDANT FIXTURE COULD BE LOCATED. A | | | NOTE FOR THIS TYPE OF FIXTURE MENTIONS ONLY ON DURING | | | MEDICAL PROCEDURES HOWEVER THESE ARE ALSO IN THE | | | CONFERENCE ROOM. BASED ON THE MAXIMUM WATTAGE TOTAL OF | | | 300 FOR ALL THREE FIXTURES THIS WOULD NOT BE OVER | | | ALLOWANCES IN TABLE 13-415.2.B AND ADDITIONAL PERMITTED | | | UNDER TABLE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-10-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-31 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-31 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2008-10-31 13:50:35 | ** DENIED REVISION** | | | | | | 1) NOTE: THERE HAVE BEEN SUBSTANTIAL REVISIONS TO FLOOR | | | LAYOUT AND ALSO LIGHTING. PLEASE SEE 13-415.2, | | | 13-415.2.ABC.1.1,.1.2 OF THE FBC TO REVISE LIGHTING | | | PERFORMANCE CALCULATIONS. | | | | | | 2) NOTE: PLEASE BE SURE ALL REVISIONS ARE IN | | | CONSECUTIVE ORDER OF PREVIOUS PLANS. THIS IS ONLY NOTED | | | AS ELECTRICAL REVISIONS AS NOTED ON TITLE BLOCKS ARE | | | OK, HOWEVER MAY AFFECT OTHER TRADES OR CHANGES. | | | | | | 3) NOTE: PLEASE BE SURE TO UPDATE ALL CIRCUITING ON | | | PLANS WITH THE REVISED PANEL SCHEDULE. NOT ALL CIRCUITS | | | SHOWN ON PLANS ARE THE SAME AS THE REVISED PANEL | | | SCHEDULE SUBMITTED. AN EXAMPLE OF THIS IS IN ROOM 103 | | | WHICH INDICATES A RECEPTACLE WITH CIRCUIT L317, 19 YET | | | THE PANEL SCHEDULE FOR CIRCUIT 19 INDICATES A | | | DISHWASHER IN ROOM 105? | | | THIS IS ONE EXAMPLE GIVEN AS A BENEFIT. THERE ARE SOME | | | OTHERS. | | | 408.4 | | | FBC 106.1.1, 106.5 FOR COORDINATION/CLARITY OF RECORD | | | PLANS. | | | | | | | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-28 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-28 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2008-07-28 09:55:46 | PROVISO FROM 6/3/08 WAS DONE. REDLINED PLANS TO REMOVE | | | PROVISO. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-03 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-03 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2008-06-03 16:26:09 | ** NOTE ADDED: | | | AS PLANS WERE REVIEWED AND DENIED BY OTHER TRADES SUCH | | | AS PLUMBING AND MECHANICAL THE 30 DAY PROVISO ISSUED ON | | | ELECTRICAL SHOULD BE ADDRESSED WHEN PLANS ARE | | | RESUBMITTED. | | | THE READINGS SHOULD HAVE ALREADY BE UNDERWAY FROM | | | LETTER DATED MAY 5TH, 2008 FROM ELECTRICAL CONTRACTOR. | | | THE DATE OF THIS ELECTRICAL REVIEW IS 6/3/08 AND THIS | | | 30 DAY WILL MOST CERTAINLY BE DONE BY THE TIME PLANS | | | ARE RE-SUBMITTED. | | | PLANS WILL GO INTO A TEMPORARY FAILED STATUS AS OTHER | | | TRADES HAVE COMMENTS AND PLANS ARE GOING OUT FOR | | | CORRECTIONS. | | | ELECTRICAL PLANS ARE ALREADY STAMPED BUT WILL REMAIN | | | FAILED UNTIL DOCUMENTATION IS SUBMITTED. | | 2008-06-03 16:17:10 | ** PROVISO/TEMP FAILED** | | | | | | | | | 1) NOTE:AS AGREED BY ELECTRICAL CONTRACTOR AND | | | CONVERSATION WITH JOHN LOWEN FROM KNIGHT ELECTRIC, | | | ELECTRICAL LOAD DETERMINATION AS REQUIRED PER 220.87 | | | WILL BE PROVIDED TO THIS OFFICE WITHIN 30DAYS OF THIS | | | REVIEW. | | | THESE SHALL CLEARLY SHOW THE ELECTRICAL LOADS ON | | | EXISTING PANEL *L3* WITH NEW LOADS BEING ADDED. PLANS | | | WILL ALSO NEED TO CLARIFY THE LOCATION OF THE EXISTING | | | PANELS *L3* AND *L3SS*. THESE MAY NOT BE IN OTHER | | | TENANT SPACE. | | | PLEASE UNDERSTAND PERMIT MAY BE REVOKED AS PERMITTED BY | | | THE IN CHAPTER 1 OF THE FLORIDA BUILDING CODE IF | | | PROVISO IS NOT COMPLIED WITH WITHIN TIME FRAME.. | | | | | | THE LETTER SUBMITTED BY THE ELECTRICAL ENGINEER QUOTING | | | THIS ELECTRICAL REVIEWER COMMENTS DO NOT SEEM TO BE | | | QUOTING THE PREVIOUS ELECTRICAL REVIEW FOR THIS | | | PROJECT? | | | THE WORDING OF THE REVIEW, THE CODE SECTIONS ETC WERE | | | NOT ON THE REVIEW OF PERMIT #08030365 DATED 3/20/08IT | | | IS UNCLEAR WHERE THESE NOTES CAME FROM. | | | IF THE PROVISO AS SET-FORTH ABOVE IS NOT ACCEPTABLE TO | | | THE DESIGN TEAM THIS OFFICE NEEDS TO BE NOTIFIED BEFORE | | | PERMIT ISSUANCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-20 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-20 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2008-03-20 17:01:32 | ** DENIEDREVIEW ** | | | | | | | | | 1) NOTE:PLEASE CLARIFY PANELS AND CIRCUITING. PANEL | | | L3 IS SHOWING A NEW FEED TO NEW PANEL L3A HOWEVER IT IS | | | UNCLEAR OF THE LOAD OR SIZE OF THE EXISTING PANEL L3 | | | WITH NEW LOADS BEING ADDED. | | | PLEASE ALSO SEE THE NEW SPACE IS SHOWING SOME CIRCUITS | | | COMING FROM EXISTING PANEL L3SS YET IT IS UNCLEAR IF | | | THE TENANT HAS ACCESS TO THIS PANEL? WHAT DOES THIS | | | PANEL FEED? OTHER TENANTS? IS IT LOCATED IN ANOTHER | | | TENANT SPACE? | | | PLEASE VERIFY LOADS, 220.87 | | | PLEASE VERIFY LOCATIONS OF ALL OVER CURRENT PROTECTION | | | DEVICES REQUIRED FOR TENANT 240.24 | | | | | | 2) NOTE: PLEASE CLARIFY WHAT THE *SD* IS WHICH IS SHOWN | | | IN EXAM ROOMS 5 AND 6. | | | PLEASE VERIFY DEVICES AND THEIR MAXIMUM TIMES. | | | | | | COMMENT #2 COULD HAVE BEEN REDLINED AND TO VIF HOWEVER | | | COMMENT #1 NEEDS TO BE CLARIFIED AND ADDRESSED AT THIS | | | TIME. | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-11-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-11-07 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-11-07 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2008-11-07 14:45:21 | REVISION DATED 9/15/08 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-05 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-08-05 |
Time |
15:14 |
Sent To |
B |
|
| Notes |
| 2008-08-05 15:35:06 | *****APPROVED***** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ACKNOWLEDGED OR ADDRESSED;PLAN SHEETS A-1 AND | | | E-1 WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-05 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-05 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2008-06-05 14:16:16 | ***DENIED*** | | | | | | 1) OK | | | | | | 2) NO INFORMATION PROVIDED OR ACKNOWLEDGMENT | | | | | | 3) NO INFORMATION PROVIDED OR ACKNOWLEDGMENT | | | | | | 4) OK | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-04-15 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-04-15 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2008-04-15 14:50:21 | *****DENIED***** | | | | | | | | | 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 2.PROVIDE A LAYOUT OF THE FIRE SPRINKLER HEADS FOR | | | THE REMODELED SPACE. | | | | | | 3.PROVIDE A LAYOUT OF THE FIRE ALARM DEVICES FOR THE | | | REMODELED SPACE. | | | | | | 4.PROVIDE TRAVEL DISTANCE TO THE EXIT. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE APPROPIATE PLAN SHEET | | | EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-01-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-14 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-14 |
Time |
14:54 |
Sent To |
P |
|
| Notes |
| 2009-01-14 14:55:01 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-12-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-04 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-04 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2008-12-04 11:23:04 | TO "COMM" BD#20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-14 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-14 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2008-10-14 16:50:04 | TO "COMM" BD#30 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-11 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-11 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2008-07-11 09:33:33 | TO "COMM" BD#27 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-05-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-13 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-13 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2008-05-13 10:17:58 | TO "COMM" BD#36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-04-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-04-15 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-03-17 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2008-03-19 13:06:40 | TO "COMM" BD#4 | | 2008-03-17 16:07:37 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2009-03-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-03-24 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-03-24 |
Time |
18:01 |
Sent To |
PC |
|
| Notes |
| 2009-03-24 18:02:02 | REVISED M-1 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-01-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-01-10 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-01-10 |
Time |
18:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2008-11-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-11-02 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-11-02 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2008-11-02 13:18:41 | REVIEW #: REVISION | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | REVISED M-1 SHOWS RETURN AIR TRANSFER DUCTS ELIMINATED | | | AND ALL ABOVE CEILING SPACES USED AS PLENUMS. THIS WILL | | | CREATE A SITUATION WHERE EXHAUST FANS AND THEIR | | | POSITIVELY PRESSURIZED EXHAUST DUCTS WILL BE LOCATED | | | WITHIN THE PLENUM SPACE. EXHAUST DUCTS UNDER POSITIVE | | | PRESSURESHALL NOT EXTEND INTO OR PASS THROUGH DUCTS OR | | | PLENUMS IN ACCORDANCE WITH FBCM 601.3. SHOW HOW THESE | | | EXHAUST DUCTS ARE TO BE ISOLATED FROM THE PLENUM IN | | | ACCORDANCE WITH THIS SECTION. ALSO, SHOW HOW THE NEWLY | | | CREATED PLENUM SPACE WALLS ABOVE THE CEILING ARE TO BE | | | FINISHED IN ACCORDANCE WITH FBCM 603.8 AND FBCM 603.9. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-07-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-24 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-24 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-30 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-30 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2008-05-30 10:51:40 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. OK | | | | | | 2. NOT E ON FAN SCHEDULE SAYS ?PROTECT ALL RATED WALLS | | | WITH FIRE/SMOKE AS REQUIRED BY CODE.? THIS NOTE IS NOT | | | IS NOT SUFFICIENT TO DEMONSTRATE CODE COMPLIANCE. THE | | | SPECIFIC LOCATION OF EACH FIRE DAMPER, CEILING DAMPER | | | AND SMOKE DAMPER SHALL BE SHOWN AND PROPERLY IDENTIFIED | | | ON THE BUILDING PLANS BY THE DESIGNER IN ACCORDANCE | | | WITH FBCM 607.8. | | | | | | 3. SIZE OF SOME RETURN AIR FLEX DUCTS STILL MISSING ON | | | PLANS. THE TWO MAIN FLEX RETURN DUCTS FROM THE MAIN | | | RETURN TRUNK LINE TO THE DOUBLE 24X24 GRILLS IN THE | | | HALL DO NOT HAVE A SIZE SHOWN ON PLANS. ALSO, THE | | | RETURN FLEX IN CONFERENCE ROOM 106 NOW HAS TWO SIZES. | | | IN ONE LOCATION IT IS SHOWN AS 12 INCH AND IN ANOTHER | | | IT IS SHOWN AS 8 INCH. WHICH IS CORRECT? PLEASE | | | CLARIFY, SHOWING COMPLIANCE WITH FBCM 601.4. | | | ADDITIONALLY, MOHS LAB 107 HAS A NOTE FOR 150 CFM. DOES | | | THIS APPLY TO THE SUPPLY REGISTER OR THE EXHAUST FAN? | | | THE DUCT SIZE FOR THIS SUPPLY REGISTER IS MISSING FROM | | | PLANS. | | | | | | 4. OK | | | | | | 5. OK | | | | | | 6. IN MOHS LAB 107 THERE IS AN EXHAUST FAN SHOWN IN THE | | | CEILING. IS THIS THE SAME TYPE OF FAN AS EF-1 ON THE | | | FAN SCHEDULE OR IS IT A 150 CFM FAN AS THE NOTE ON THE | | | FLOOR PLAN INDICATES? WHERE IS THE DUCT FOR THIS FAN | | | AND WHAT SIZE IS THE DUCT? SEE COMMENT #2 ABOVE FOR | | | ISSUES RELATED TO EXHAUST FAN DUCTWORK. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-03-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-03-29 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-03-29 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2008-03-29 17:05:32 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. M-1 PLAN STATES THE HVAC DESIGN IS BY ALTMAN | | | BROTHERS, LLC. AN INSTALLING AIR-CONDITIONING | | | CONTRACTOR CERTIFIED UNDER CHAPTER 489, FLORIDA | | | STATUTES MAY DESIGN AN AIR CONDITIONING SYSTEM UNDER 15 | | | TONS ONLY IF THIS SYSTEMS SERVES A BUILDING WITH LESS | | | THAN 100 OCCUPANTS, THE SYSTEMS HAS INDEPENDENT DUCTS | | | AND COSTS LESS THAN $50,000. AS THIS SPACE IS BEING | | | SERVED BY A VAV BOX FED BY A LARGER A/C SYSTEM IN A | | | BUILDING WITH AN OCCUPANT LOAD GREATER THAN 100, THIS | | | SYSTEM IS NOT ELIGIBLE TO BE DESIGNED BY AN AIR | | | CONDITIONING CONTRACTOR. THIS PLAN SHALL BE SIGNED AND | | | SEALED BY A PROFESSIONAL ENGINEER IN ACCORDANCE WITH | | | FBCB 105.3.1.2. | | | | | | 2. M-1: FLOOR PLAN SHOWS 10 INCH ROUND DUCT PENETRATING | | | TWO NEW 1-HOUR RATED CORRIDOR WALLS. SHOW HOW THESE | | | PENETRATIONS ARE TO BE PROTECTED IN ACCORDANCE WITH | | | FBCM 607.5 AND 607.1.1. | | | | | | 3. M-1: PROVIDE SIZE OF RETURN AIR FLEX DUCTS TO SHOW | | | HOW BALANCED RETURN IS BEING ACHIEVED IN ACCORDANCE | | | WITH FBCM 601.4. IF TRANSFER DUCTS ARE NOT DESIGNED TO | | | MEET THE EXCEPTIONS UNDER THIS SECTION, A FIELD TEST | | | WILL BE REQUIRED AT FINAL INSPECTION TO DETERMINE IF | | | PRESSURE DIFFERENTIALS ACROSS CLOSED DOORS ARE AT 0.01 | | | INCHES WC OR LESS. | | | | | | 4. M-1 FIRE DAMPER DETAIL, NOTE #1: FIRE DAMPERS AND | | | SMOKE DAMPERS LOCATED WITHIN AIR DISTRIBUTION AND SMOKE | | | CONTROL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH | | | THE REQUIREMENTS OF THIS SECTION, AND THE | | | MANUFACTURER?S INSTALLATION INSTRUCTIONS AND LISTING | | | REGARDLESS OF THE DETAIL ON THE PLANS AS THESE DAMPERS | | | ARE PART OF A LISTED AND TESTED ASSEMBLY IN ACCORDANCE | | | WITH FBCM 607.2 AND 607.3. | | | | | | 5. THIS WORK IS BEING PROPOSED IN AN EXISTING BUILDING; | | | THEREFORE THE DESIGN PROFESSIONAL MUST ELECT ONE OR A | | | COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THE FLORIDA EXISTING | | | BUILDING CODE IN ACCORDANCE WITH FBCEB 301.5. AS A | | | LEVEL OF ALTERATION HAS NOT BEEN DECLARED, FOR THE | | | PURPOSE OF THIS REVIEW, IT IS BEING ASSUMED THAT THIS | | | IS A LEVEL 2 ALTERATION AS DEFINED IN FBCEB 304.1. | | | | | | 6. M-1: NO INFORMATION WAS PROVIDED REGARDING THE | | | TOILET ROOM EXHAUST FAN OR ANY OTHER ASPECT OF | | | VENTILATION REQUIREMENTS FOR THIS SPACE. ALL | | | RECONFIGURED SPACES INTENDED FOR OCCUPANCY IN ANY WORK | | | AREA SHALL BE PROVIDED WITH NATURAL OR MECHANICAL | | | VENTILATION OR EXHAUST IN ACCORDANCE WITH THE FBCEB | | | 609.1. SHOW VENTILATION AND EXHAUST RATES TO BE IN | | | COMPLIANCE WITH FBCM SECTION 403.3. PROVIDE OUTSIDE AIR | | | CALCULATIONS, INCLUDING OCCUPANCY CLASSIFICATIONS, | | | OCCUPANT LOADS, OUTSIDE AIR REQUIRED AND OUTSIDE AIR | | | PROVIDED FOR EACH SPACE IN ACCORDANCE WITH FBCM TABLE | | | 403.3. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2009-01-20 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2009-01-20 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2009-01-20 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2009-01-20 13:43:57 | REVISION OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2009-01-12 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2009-01-12 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2009-01-12 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2009-01-12 11:10:09 | REVISION OK -SHEET P-1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2008-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-28 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-28 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2008-10-28 10:49:36 | REVISION DENIED | | | REFERENCE: FBC-2004 CHAPTER 1 | | | FBC-2004 PLUMBING | | | | | | 1. SHT P-1 INDICATES REVISION #3 DATED 9-15-2008. OUR | | | FILE SET OF PLANS HAS A REVISION #3 DATED 7-3-2008. THE | | | REVISIONS SHALL BE IN SEQUENCE AND PREVIOUS REVISIONS | | | SHALL NOT BE DELETED FROM THE REVISION INDEX/MATRIX. | | | SECTION 106.1.3. PLEASE SHOW NEW REVISION AS REVISION | | | #4 OR ABOVE AND SHOW THE PREVIOUS REVISION #3 IN | | | REVISION INDEX. | | | | | | 2. SHT P-1 SANITARY RISER DIAGRAM, THE FOUR SINKS IN | | | THE EXAM ROOM ARE NOT VENTED. SECTION 901.2.1. (AN AAV | | | ON ONE SINK AT EACH SUMP WILL MEET THIS REQUIREMENT). | | | | | | 3. SHT P-1 THE FOUR SINKS SHALL DRAIN INTO THE SUMP NOT | | | THE DISCHARGE LINE ON THE SANITARY RISER DIAGRAM. | | | SECTION 712.1. SHOW THE SINKS DRAINING TO THE SUMP. | | | | | | 4. SHT P-1 SANITARY RISER DIAGRAM SHOWS SHUT OFF VALVES | | | ON THE DISCHARGE SIDE OF THE CHECK VALVES. SECTION | | | 712.2 REQUIRES A FULL OPEN VALVE. PLEASE INDICATE ON | | | RISER DIAGRAM. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-28 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-28 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-05-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-28 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-28 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2008-05-28 16:10:24 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: (2ND REVIEW) | | | | | | 1. OK | | | | | | 2. SHT P-1 SANITARY RISER DIAGRAM THE SINKS IN ROOMS | | | 109 & 110 SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT PER SECTION 909.1. | | | ****RESPONSE NOTED, BUT THE SINKS STILL DRAIN THRU THE | | | HORIZONTAL WET VENT FOR THE TOILET ROOM. THE LAV IS THE | | | VENT FOR THE WATER CLOSET ONLY. (SEE RED LINE | | | CORRECTION ON ONE SET OF PLANS). | | | | | | 3. OK | | | 4. OK | | | 5. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-04-11 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-04-11 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2008-04-11 17:25:55 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA STATUTES | | | | | | 1. SHT P-1 SANITARY RISER DIAGRAM INDICATES THE PIPE | | | SIZE AS 2" CONNECTING TO THE STACK AND UP TO THE TOILET | | | ROOM. MINIMUM 3" REQUIRED TO THE W/C PER TABLE 709.1. | | | | | | 2. SHT P-1 SANITARY RISER DIAGRAM THE SINKS IN ROOMS | | | 109 & 110 SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL | | | WET VENT PER SECTION 909.1. | | | | | | 3. SHT P-1WATER RISER DIAGRAM SHALL SHOW ALL PIPE | | | SIZES, AND INDICATE THE LOCATION OF THE CONNECTION TO | | | THE WATER MAIN. SECTIONS 106.1.2, 601.1 &604. | | | | | | 4. SHT P-1 THE HUB DRAIN FOR THE P/T AND PAN DRAIN FOR | | | THE WATER HEATER SHALL HAVE A TRAP PRIMER. SECTION | | | 1002.4. | | | | | | 5. DESIGN SHALL BE PER FBC-2004 W/2007 AMENDMENTS. | | | PLEASE INDICATE ON PLANS. SECTION 106.1.2 & FS | | | 533.73(1)(A). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|