Plan Review Details - Permit 08030288
Plan Review Stops For Permit 08030288
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-03-20 Cont ID  
Sent By shill Date 2008-03-20 Time 17:57 Rev Time 0.00
Received By shill Date 2008-03-20 Time 17:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-03-13 Cont ID  
Sent By shill Date 2008-03-13 Time 14:25 Rev Time 0.00
Received By shill Date 2008-03-13 Time 14:25 Sent To  
Notes
2008-03-13 14:27:16****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER BARRIER
 REQUIRED FS553.844(5)(A). PROVIDE INFORMATION
 (PRODUCT APPROVAL OR SPECIFICATIONS) TO SHOW HOW YOU
 WILL COMPLY WITH THIS REQUIREMENT.INFORMATION IS
 AVAILABLE AT WWW.BOAF.NET, HURRICANE MITIGATION.
  
 SEE MITIGATION MANUAL:
  
 201.2 ROOF SECONDARY WATER BARRIER FOR SITE-BUILT
 SINGLE FAMILY RESIDENTIAL STRUCTURES. A SECONDARY WATER
 BARRIER SHALL BE INSTALLED USING ONE OF THE FOLLOWING
 METHODS WHEN ROOFING REPLACEMENT WHEN REROOFING.
 A) ALL JOINTS IN ROOF SHEATHING OR DECKING SHALL BE
 COVERED WITH A MINIMUM 4 IN. WIDE STRIP OF
 SELF-ADHERING POLYMER MODIFIED BITUMEN TAPE APPLIED
 DIRECTLY TO THE SHEATHING OR DECKING. THE DECK AND SELF
 ADHERING POLYMER MODIFIED BITUMEN TAPE SHALL BE COVERED
 WITH ONE OF THE UNDERLAYMENT SYSTEMS APPROVED FOR THE
 PARTICULAR ROOF COVERING TO BE APPLIED TO THE ROOF.
 B) THE ENTIRE ROOF DECK SHALL BE COVERED WITH AN
 APPROVED SELF-ADHERING POLYMER MODIFIED BITUMEN CAP
 SHEET. NO ADDITIONAL UNDERLAYMENT SHALL BE REQUIRED ON
 TOP OF THIS CAP SHEET FOR NEW INSTALLATIONS.
  
 EXCEPTIONS:
 1. AN ASPHALT IMPREGNATED 30# FELT UNDERLAYMENT
 INSTALLED WITH NAILS AND TIN-TABS AS REQUIRED FOR THE
 HVHZ AND COVERED WITH EITHER AN APPROVED SELF-ADHERING
 POLYMER MODIFIED BITUMEN CAP SHEET OR AN APPROVED CAP
 SHEET APPLIED USING AN APPROVED HOT-MOP APPLICATION
 SHALL BE DEEMED TO MEET THE REQUIREMENTS FOR THE
 SECONDARY WATER BARRIER.
  
 PLEASE SHOW HOW THE CARLISLE WIP100 IS COMPLIANT WITH
 THE MANUAL.ACCORDING TO THE NOA PROVIDED, IT IS
 ASPHALT, NOT MODIFIED, AND IS AN UNDERLAYMENT, NOT AN
 APPROVED CAP SHEET.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved