| 2008-03-12 16:08:49 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | 1.DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR |
| | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS |
| | FS471. |
| | |
| | 2.THE ENGINEER M. PHIL MCCONAGHEY, PE STATES IN HIS |
| | LETTER DATED 2/21/08 THAT THIS IS A CONCRETE DECK, WITH |
| | REFERENCE TO A MIAMIDADE NOA WHICH IS FOR A WOOD DECK. |
| | PLANS SHOW A WOOD DECK.PLEASE CORRELATE. |
| | |
| | 3.ROOFING SYSTEM DESIGN RECOMMENDATIONS ARE BASED ON |
| | ASCE7-98, SEE FBC CHAPTER 35, SHOULD USE ASCE7-02. |
| | |
| | 4.THE FORM HVHZ SECTION C INFORMATION PROVIDED BY |
| | CONTRACTOR CONFLICTS WITH THE OTHER INFORMATION |
| | PROVIDED.SECTION C STATES THAT THIS IS A RECOVER, |
| | OVER EXISTING BUR.THIS FORM IS NOT REQUIRED AS THE |
| | ENGINEERING (WHICH IS REQUIRED BY GENERAL LIMITATION #7 |
| | OF THE NOA) PROVIDES ALL REQUIRED INFORMATION. |
| | HOWEVER, CONTRACTOR IS TO CONFIRM SCOPE OF WORK.IF |
| | THIS IS A RECOVER RATHER THAN A REROOF, PROVIDE THE |
| | APPROPRIATE PRODUCT APPROVAL AND REVISE THE PERMIT |
| | APPLICATION AND ENGINEERING.A PREINSPECT WILL BE |
| | REQUIRED FOR A ROOF RECOVER. |
| | |