|
 |
 |
 |
 |
 |
Plan Review Details - Permit 08030139
| Plan Review Stops For Permit 08030139 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2008-04-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-04-02 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-04-02 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2008-04-02 16:24:28 | LEFT MESSAGE FOR CONTRACTOR / NEED STORM PANEL | | | INSTALLATION INFORMATION AND NOC. | | | | | | 4/3/08 CONTRACTOR CALLED AND PROVIDED STORM PANEL | | | INSTALLATION INFORMATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-03-12 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-03-11 |
Time |
12:32 |
Sent To |
E |
|
| Notes |
| 2008-03-12 07:40:28 | 2004 FBC W/2007 REVISIONS | | | LEVEL 2 ALTERATIONS | | | | | | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT WILL | | | BE REQUIRED. | | | | | | 2) THE PLANS WITH THE ENGINEER'S TITLE BLOCK IS | | | REQUIRED TO BE SIGNED SEALED AND DATED BY THE ENGINEER. | | | FS 471 AND FBC 106.1* CITY AMENDMENTS | | | | | | 3) PROVIDE STRUCTURAL DETAILS FOR THE NEW DOOR OPENING | | | AT THE EXISTING WINDOW. PROVIDE BUCK DETAILS.FBC | | | 106.1.1* CITY AMENDMENTS | | | | | | 4) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR THE | | | NEW DOOR AND NEW WINDOWS THAT WERE MISSED. FBC TABLE R | | | 301.2(2) | | | | | | 5) SPECIFY WHICH WINDOWS ARE SINGLE HUNG AND CASEMENT. | | | FBC 106.1.1* CITY AMENDMENTS | | | | | | 6) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL WINDOW | | | MULLIONS AS REQUIRED BY RULE 9B-72 F.A.C. | | | | | | 7) SUBMIT TWO (2) COPIES OF A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY THE CONNECTION | | | TYPE, FASTENER TYPE AND SPACING, EDGE DISTANCE, SPANS, | | | ETC. SEE SAMPLE SCHEDULE ATTACHED. | | | | | | 8) SHOW COMPLIANCE WITH R311.6.3 HANDRAILS REQUIRED. | | | HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF ALL | | | RAMPS EXCEEDING A SLOPE OF ONE UNIT VERTICAL IN 12 | | | UNITS HORIZONTAL (8.33-PERCENT SLOPE). | | | | | | 9) SHOW COMPLIANCE WITH R 311.6.3.2 HANDRAIL GRIP SIZE | | | AND R311.6.3.3 CONTINUITY. | | | | | | 10) AN EXTERIOR LIGHT FIXTURE WITH A SWITCH IS REQUIRED | | | AT THE NEW EXTERIOR DOOR PER THE 2005 NEC SECTION | | | 210.70(2)(B). | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-03-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-27 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-27 |
Time |
11:18 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-13 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-13 |
Time |
13:27 |
Sent To |
I |
|
| Notes |
| 2008-03-13 13:36:49 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | | CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | | FOLLOWING: | | | | | | 1} 210.70(A) (2) (B) FOR DWELLING UNITS, ATTACHED | | | GARAGES, AND DETACHED GARAGES WITH ELECTRIC POWER, AT | | | LEAST ONE WALL SWITCH?CONTROLLED LIGHTING OUTLET SHALL | | | BE INSTALLED TO PROVIDE ILLUMINATION ON THE EXTERIOR | | | SIDE OF OUTDOOR ENTRANCES OR EXITS WITH GRADE LEVEL | | | ACCESS. A VEHICLE DOOR IN A GARAGE SHALL NOT BE | | | CONSIDERED AS AN OUTDOOR ENTRANCE OR EXIT. SHOW | | | COMPLIANCE AT THE NEW DOOR LOCATION. | | | | | | 2} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK | | | MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 | | | FAC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-25 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-25 |
Time |
13:12 |
Sent To |
Z |
|
| Notes |
| 2008-03-25 13:13:25 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-13 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-07 |
Time |
11:19 |
Sent To |
PC |
|
| Notes |
| 2008-03-07 11:19:57 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-03-27 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-27 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-27 |
Time |
08:34 |
Sent To |
E |
|
| Notes |
| 2008-03-27 08:34:36 | ***APPROVED - RESUB #1*** | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-03-11 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-11 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-11 |
Time |
09:21 |
Sent To |
B |
|
| Notes |
| 2008-03-11 09:25:13 | ***FAILED*** | | | | | | | | | 1)PLANS INCONSISTENT.EXISTING SIDE SETBACKS DO NOT | | | MATCH BETWEEN SURVEY AND SITEPLAN AND DO NOT MAKE SENSE | | | GIVEN THE SIZE OF THE PROPOSED RAMP.PLEASE CLARIFY. | | | ALSO INDICATE THE SETBACK DIMENSION FROM THE PROPOSED | | | RAMP TO THE SIDE PROPERTY LINE.NOTE:MUST MAINTAIN A | | | MINIMUM 2 FOOT SETBACK TO SIDE. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | | | | | | | | | | | | | SENT TO "B" - MISC. 2 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |