Plan Review Details - Permit 08030053
Plan Review Stops For Permit 08030053
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-04-29 Cont ID  
Sent By shill Date 2008-04-29 Time 14:53 Rev Time 0.00
Received By shill Date 2008-04-29 Time 14:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-04-15 Cont ID  
Sent By shill Date 2008-04-15 Time 10:02 Rev Time 0.00
Received By shill Date 2008-04-15 Time 10:02 Sent To  
Notes
2008-04-15 12:15:18****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1.PLEASE INCORPORATE POOL SAFETY REQUIREMENTS INTO
 THE PLAN, FBC R4101.17.
  
 THE ENGINEER SUBMITTED WHAT IS EFFECTIVELY AN AFFIDAVIT
 STATING THAT THE HOMEOWNER AGREES TO COMPLY WITH
 FBC4101.THE COMMENT REQUESTED THAT THE DESIGN
 CRITERIA BE INCORPORATED.CODE SECTIONS CANNOT BE
 CITED IN LIEU OF PROVIDING DESIGN CRITERIA; PLANS ONLY
 SAY "BARRIER" BUT BARRIER REQUIREMENTS ARE NOT STATED.
 PLEASE STATE DESIGN CRITERIA, EITHER AS OPTIONS OR
 SPECIFIC TO THIS JOB.
  
 NEW COMMENT:
  
 2.SEE OTHER REVIEWERS' COMMENTS REGARDING THE
 SIGNATURES ON PLANS.PLEASE NOTE THAT, WHEN PLANS ARE
 SUBMITTED WITH SUCH OBVIOUSLY DIFFERENT SIGNATURES, WE
 ARE OBLIGATED TO CONFIRM THAT ALL PLANS WERE INDEED
 SIGNED AND SEALED BY THE ENGINEER FOR THE PROTECTION OF
 THE OWNER AND THE ENGINEER.IF THE ENGINEER MAKES A
 HABIT OF USING DIFFERENT SIGNATURES ROUTINELY, PERHAPS
 HE MIGHT CONSIDER INCLUDING A COVER LETTER ADDRESSING
 THIS ISSUE WITH EXAMPLES.ALTERNATIVELY, PLEASE
 PROVIDE SOME CONSISTENCY, ESPECIALLY WITHIN A PERMIT
 PACKAGE (ALL DOCUMENTS WITHIN ONE PERMIT APPLICATION
 SHOULD HAVE SIGNATURES WHICH ARE SIMILAR TO EACH
 OTHER).

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-03-10 Cont ID  
Sent By shill Date 2008-03-10 Time 11:57 Rev Time 0.00
Received By shill Date 2008-03-10 Time 11:57 Sent To  
Notes
2008-03-10 12:14:12****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.PLEASE INCORPORATE POOL SAFETY REQUIREMENTS INTO
 THE PLAN, FBC R4101.17.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-04-23 Cont ID  
Sent By btrobaug Date 2008-04-23 Time 10:48 Rev Time 0.00
Received By btrobaug Date 2008-04-23 Time 10:37 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-04-10 Cont ID  
Sent By btrobaug Date 2008-04-10 Time 11:40 Rev Time 0.00
Received By btrobaug Date 2008-04-10 Time 11:05 Sent To P
Notes
2008-04-10 11:40:04 
  
  
 NONCOMPLIANT
  
 THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK MUST
 SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 FAC.
 THERE ARE TWO DIFFERENT SIGNATURES ON THE ENGINEERS
 SEAL ON DIFFERENT SHEETS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2008-03-06 Cont ID  
Sent By btrobaug Date 2008-03-06 Time 13:55 Rev Time 0.00
Received By btrobaug Date 2008-03-06 Time 13:49 Sent To P
Notes
2008-03-06 14:01:16 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
 1} PROVIDE A LIST OF THE EQUIPMENT INTENDED TO BE
 INSTALLED UNDER THIS PERMIT.
  
 2} SUPPLY THE SPECIFICATIONS FOR SAME.
  
 3} REMOVE ALL "OPTIONAL" EQUIPMENT NOT INTENDED TO BE
 INSTALLED UNDER THIS PERMIT , FROM THE PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2008-04-11 Cont ID  
Sent By mperson Date 2008-04-11 Time 14:55 Rev Time 0.00
Received By mperson Date 2008-04-11 Time 14:55 Sent To B
Notes
2008-04-11 14:56:08NOTE: THERE IS NO POOL HEATER GAS OR ELECTRIC.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2008-03-07 Cont ID  
Sent By mperson Date 2008-03-07 Time 13:26 Rev Time 0.00
Received By mperson Date 2008-03-07 Time 13:26 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-10-03 Cont ID  
Sent By mperson Date 2008-10-03 Time 10:10 Rev Time 0.00
Received By mperson Date 2008-10-01 Time 10:09 Sent To PC
Notes
2008-10-03 10:09:52PLBG/REV #2 TO "P" BOX.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-06-11 Cont ID  
Sent By adarroug Date 2008-06-11 Time 11:19 Rev Time 0.00
Received By adarroug Date 2008-06-11 Time 11:19 Sent To P
Notes
2008-06-11 11:19:32TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-04-22 Cont ID  
Sent By adarroug Date 2008-04-22 Time 12:01 Rev Time 0.00
Received By adarroug Date 2008-04-22 Time 12:01 Sent To E
Notes
2008-04-22 12:01:32TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-04-03 Cont ID  
Sent By adarroug Date 2008-04-03 Time 09:26 Rev Time 0.00
Received By adarroug Date 2008-04-03 Time 09:26 Sent To E
Notes
2008-04-03 09:26:34TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-03-04 Cont ID  
Sent By adarroug Date 2008-03-04 Time 14:49 Rev Time 0.00
Received By shill Date 2008-03-04 Time 14:49 Sent To Z
Notes
2008-03-04 14:49:28TO "Z" BOX

Review Stop P PLUMBING
Rev No 5 Status P Date 2008-10-03 Cont ID  
Sent By mperson Date 2008-10-03 Time 09:58 Rev Time 0.00
Received By mperson Date 2008-10-03 Time 09:58 Sent To I
Notes
2008-10-03 10:07:57REVISION #2: "OK" ADDED AUTOMATIC POOL FILLER AND
 BACKFLOW PREVENTER. VALUE INCREASED $300.00 NOT ON
 ORIGINAL PLANS. *MRPERSON.
  
 ****************PROVISO****************
 PER FLORIDA STATUTES 489.105 (3)(M) PLUMBING
 CONTRACTOR: THE BACKFLOW PREVENTER FOR THE POTABLE
 WATER SUPPLY TO THE AUTOMATIC POOL FILLER SYSTEM SHALL
 BE INSTALLED BY A LICENSED PLUMBING CONTRACTOR. PLEASE
 KNOW THAT THE WILKINS 975XL IS APPROVED FOR THE
 AUTOMATIC POOL FILLER, HOWEVER A WATTS N36 VACUUM
 RELIEF VALVE WOULD ALSO WORK. PER PHONE CONVERSTION
 WITH POOL CONTRACTOR NINO TOZZI A 3/4" WILKINS 975XL
 BACKFLOW PREVENTER HAS BEED INSTALLED. SEPERATE PERMIT
 REQUIRED.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-06-16 Cont ID  
Sent By mperson Date 2008-06-16 Time 09:15 Rev Time 0.00
Received By mperson Date 2008-06-16 Time 09:15 Sent To PC
Notes
2008-06-16 09:19:56REVISION: "OK" MAIN DRAIN DETAIL FOR 3" FUTURE
 WATERFALL PIPE.
  
 ****************PROVISO****************
 MAIN DRAINS TO BE SEPERATED MINIMUM 36 INCHES AND VENT
 TEE SHALL BE MAXIMUM 12 INCHCES AS PER PREVIOUS DETAIL.

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-04-25 Cont ID  
Sent By mperson Date 2008-04-25 Time 08:37 Rev Time 0.00
Received By mperson Date 2008-04-25 Time 08:37 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-04-11 Cont ID  
Sent By mperson Date 2008-04-11 Time 14:49 Rev Time 0.00
Received By mperson Date 2008-04-11 Time 14:49 Sent To G
Notes
2008-04-11 14:54:52PLUMBING PLAN REVIEW:
 DENIED 2ND TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. THERE ARE TWO DIFFERENT SIGNATURES ON THE ENGINEER
 SEAL ON DIFFERENT SHEETS. THE ENGINEER WHOSE NAME
 APPEARS ON THE TITLE BLOCK MUST SIGN, DATE AND SEAL THE
 DOCUMENTS. PER 61G15-230..2 FAC.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-03-07 Cont ID  
Sent By mperson Date 2008-03-07 Time 11:44 Rev Time 0.00
Received By mperson Date 2008-03-07 Time 11:44 Sent To G
Notes
2008-03-07 13:26:41PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 PLUMBING PLAN REVIEW:
 DENIED:
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. CORRELATE THE PIPING ISOMETRIC WITH THE POOL PLAN:
 THE POOL PLAN IS INDICATING ONE SKIMMER PIPED 1-1/2",
 TWO RETURNS FROM AN 1-1/2" PIPE,AND A 2" MAIN DRAIN.
 THE PIPING ISOMETRIC IS INDICATING SIX PIPES EXTRA.
 THE PIPING ISOMETRIC SHALL CLEARLY REFLECT THE POOL
 PLAN AND ANY EXTRA PIPING SHALL BE DELETED TO ADVOID
 CONFUSION. PER CITY OF WPB AMENDMENTS TO CHAPTER 1,
 SECTION 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. PIPING ISOMETRIC IS INDICATING A HEAT PUMP HOWEVER
 THE ELECTRICAL RISER IS INDICATING HEAT PUMP OPTIONAL.
 PROVIDE POOL SPECIFICATIONS THAT CLEARLY INDICATES
 EXACTLY WHAT EQUIPMENT IS BEING INSTALLED. SEE POOL
 SECIFICATIONS "EXAMPLE ONLY" ATTACHED TO THESE COMMENTS
 FOR REFERENCE.
 NOTE: IF THERE IS A HEAT PUMP OR GAS HEATER BEING USED
 PLEASE PROVIDE THE FOLLOWING.
  
 A) FBC-2004 SEC. 424.2.14.1, OR
 FBCR-2004 SEC. R4101.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. (MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
  
 B) FBC-2004 SEC. 424.2.14.2, OR
 FBCR-2004 SEC. R4101.14.2 WATER
 RETENTION, PROVIDE A POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN PUMP
 IS SHUT OFF.(MANUFACTURE SHEETS
 REQUIRED, PLEASE SUBMIT)
  
 3. PLANS HAVE HAND WRITTEN CHANGES WITH NO INDICATION
 THEY WERE DONE BY THE DESIGN PROFESSIONAL OF RECORD
 MORRIS A. SHASHOUA PE NO 19554. PER CHAPTER 471,
 FLORIDA STATUTES ANY CHANGES TO THE PLANS SHALL BE BY
 THE DESIGN PROFESSIONAL OF RECORD.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION
 AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2008-03-06 Cont ID  
Sent By choops Date 2008-03-06 Time 09:23 Rev Time 0.00
Received By choops Date 2008-03-06 Time 09:23 Sent To E
Notes
2008-03-06 09:26:01***APPROVED***
  
 PROVISOS:
 1)PROPOSED POOL EQUIPMENT MAY NOT PROJECT MORE THAN 4
 FEET INTO A REQUIRED SETBACK AS PER SECTION
 94-305(B)(4) OF THE ZLDRS.
 2)FENCE ENCLOSURE SHALL CONFORM TO THE MINIMUM
 STANDARDS PROVIDED BELOW.
  
 PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B)+(C):
 B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE
 OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT
 ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF
 THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL
 SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH
 WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT
 SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.