Plan Review Details - Permit 08020735
| Plan Review Stops For Permit 08020735 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-12 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-12 |
Time |
12:49 |
Sent To |
M |
|
| Notes |
| 2008-03-12 12:50:27 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-03 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-02-29 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2008-02-29 16:04:40 | TO "M" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-13 |
Time |
10:00 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-03-13 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-03 |
Time |
15:26 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-03-03 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2008-03-03 15:51:23 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLEASE ADD AN A/C EQUIPMENT SCHEDULE WITH MAKE, | | | MODEL NUMBERS, ETC, TO MECHANICAL PLAN, PER 2004 WPB | | | AMEND. 106.3.5.4 (10). | | | | | | 2) SEE YELLOW HIGH LIGHT ON MECH. PLAN SHOWING SUPPLY | | | AIR DUCTS (FLEX) THAT NEED TO SIZED, PLEASE CORRECT PER | | | 2004 WPB AMEND. 106.3.5.4 (10). | | | | | | 3) SEE YELLOW HIGH LIGHT ON MECH. PLAN SHOWING SUPPLY | | | AIR GRILL WITH NO DUCK (FLEX), PLEASE CORRECT PER 2004 | | | WPB AMEND. 106.3.5.4 (10). | | | | | | 4) SEE YELLOW HIGH LIGHT AT RETURN AIR GRILL NEAR AIR | | | HANDLER NEEDS THE COMPLETE SIZE, IT IS ONLY SHOWING 24 | | | X __, PLEASE CORRECT. | | | | | | 5) PLEASE SHOW THE LOCATION OF THE TWO GAS TANKLESS | | | WATER HEATERS ON THE MECHANICAL PLAN, SEE 2004 FBC/FG | | | 304.1 AND 304.5.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
|