Plan Review Details - Permit 08020675
Plan Review Stops For Permit 08020675
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-03-19 Cont ID  
Sent By rmcdouga Date 2008-03-19 Time 08:25 Rev Time 0.00
Received By rmcdouga Date 2008-03-19 Time 08:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-03-07 Cont ID  
Sent By rmcdouga Date 2008-03-07 Time 11:11 Rev Time 0.00
Received By rmcdouga Date 2008-03-07 Time 11:11 Sent To  
Notes
2008-03-07 11:13:262004 FBC W/2007 REVISIONS
 LEVEL 2 ALTERATION
  
 DENIED
  
 1)PROVIDE BUCK FASTENING DETAILS. SPECIFY THE SPACING
 AND EMBED DEPTH OF THE TAPCONS THAT WILL BE USED TO
 ATTACH THE 2X WOOD BUCKS.
  
 2) SUBMIT (2) TWO COPIES OF PRODUCT APPROVALS FOR STORM
 PANELS THAT ARE REQUIRED FOR THE NEW FRENCH DOORS. FAC
 RULE 9B-72 AND R301.2.1.2.
  
 3) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 NEW FRENCH DOORS REQUIRE THE DOORS TO HAVE IMPACT
 PROTECTION. SUBMIT (2) COPIES OF PRODUCT APPROVALS FOR
 THE STORM PANELS THAT WILL BE INSTALLED. SPECIFY THE
 MOUNT TYPE, FASTENER TYPE AND SPACING BY CIRCLING THE
 ONES THAT WILL BE USED ON THE PRODUCT APPROVAL.
  
 4)THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN IS REQUIRED ON THE DRAWINGS. FBC
 106.1.3* CITY AMENDMENTS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-02-29 Cont ID  
Sent By rmcdouga Date 2008-02-29 Time 11:04 Rev Time 0.00
Received By rmcdouga Date 2008-02-29 Time 11:04 Sent To  
Notes
2008-02-29 13:05:272004 FBC W/2007 REVISIONS
 LEVEL 2 ALTERATION
  
 DENIED
  
 1) THE SCOPE OF WORK ON THE APPLICATION STATES THAT THE
 EXISTING BEDROOM WINDOW IS BEING REPLACED BY FRENCH
 DOORS. SUBMIT STRUCTURAL DETAILS FOR THE OPENING.
 SPECIFY THE EXISTING OPENING SIZE AND THE NEW OPENING
 SIZE. IF CBS CONSTRUCTION SHOW LOCATION AND SIZE OF
 STEEL REINFORCING, BLOCK LINTEL AND TIE BEAM. IF WOOD
 FRAME SHOW HEADER SIZE, FRAMING DETAILS, HURRICANE
 STRAPPING.
  
 2)PROVIDE BUCK FASTENING DETAILS.
  
 3) SUBMIT PRODUCT APPROVALS FOR STORM PANELS THAT ARE
 REQUIRED FOR THE NEW FRENCH DOORS. FAC RULE 9B-72 AND
 R301.2.1.2.
  
 4) THE VALUE OF THE WORK ($200) IS TOO LOW. THE VALUE
 IS TO INCLUDE THE COST OF MATERIALS AND LABOR AS WOULD
 BE CHARGED BY A CONTRACTOR.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2008-03-06 Cont ID  
Sent By adarroug Date 2008-03-06 Time 12:21 Rev Time 0.00
Received By adarroug Date 2008-03-06 Time 12:21 Sent To B
Notes
2008-03-06 12:21:24TO "RMCDOUGAL" DESK/RESUB


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved